Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser directionality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Topographic Change Detection Using Full-Waveform Imaging Lidar

The capability of wide-footprint (i.e. 10m or greater), full-waveform laser altimeters to penetrate beneath dense vegetation to directly measure the sub-canopy topography provides us with a unique capability for sensing topographic change in the presence of vegetation. We evaluate the feasibility of using a geolocated laser altimeter return waveform instead of individual elevation measurements to measure vertical elevation change within a laser footprint. The method, dubbed the return pulse correlation method, maximizes the shape similarity of nea-coincident, vertically- geolocated laser return waveforms from two observation epochs as they are vertically-shifted relative to each other. First, we evaluate the inherent accuracy of the pulse correlation method using models and simulations under "bare-Earth" conditions. We then analyze the effects of vegetation and vegetation growth on the change detection capability. The use of this method, combined with order of magnitude improvements to laser altimeter swath widths (from 1 km to 10 km) and the potential for a future spaceborne imaging lidar, may provide subcentimeter level relative change detection beneath vegetation to complement IFSAR's ability to make similar measurements in low or vegetation-free conditions.

Blair, Bryan↗

Direct observation of ion micromotion in a linear Paul trap

In this paper, the first direct observation of micromotion for multiple ions in a laser-cooled trapped ion crystal is discussed along with a novel measurement technique for micromotion amplitude. Micromotion is directly observed using a time-resolving, single-photon sensitive camera that provides both fluorescence and position data for each ion on the nanosecond time scale. Micromotion amplitude and phase for each ion in the crystal is measured which allows this method to be sensitive to tilts and shifts of the ion chain from the null of the radiofrequency quadrupole potential in the linear trap. Spatial resolution makes this micromotion detection technique suitable for complex ion configurations, including two-dimensional geometries. It does not require any additional equipment or laser beams, and the modulation of the cooling lasers or trap voltages is not necessary for detection, as it is in other methods.

74 ATOMIC AND MOLECULAR PHYSICS↗

Micro-segregation phenomena and related spectroscopic signals in melt-grown β-Ga2O3 single crystals

One of the primary advantages of β-Ga2O3 over incumbent wide bandgap semiconductors is the ability to grow directly from the melt. Melt growth, using Czochralski or similar methods, results in impurities in the crystal which originate from the crucible, such as iridium and other transition metals like chromium. These impurities exhibit optoelectronic signatures useful for their identification and sensitive to the Fermi energy of a given crystal (i.e., signatures vary with the electrical conductivity of the matrix). In this work, we describe how laser Raman systems can be used to map and spatially correlate Cr3+ photoluminescence, electronic-coupled Raman scattering from Ir4+d–d internal transitions, and the Raman line attributed to hydrogenic shallow donors. Laser ablation inductively coupled plasma mass spectrometry directly measured spatially dependent relative metal concentrations and confirmed spectroscopic signals resulting from heterogeneities in impurity concentrations in β-Ga2O3 boules. Mapping of photoluminescence and Raman-related signatures is, thus, demonstrated as an effective and facile method for spatial measurement of chemical heterogeneities in both insulating and conductive melt-grown β-Ga2O3 crystals.

Dutton, Benjamin L. (ORCID:000000031272130X)↗

Airborne 2 color ranging experiment

Horizontal variations in the atmospheric refractivity are a limiting error source for many precise laser and radio space geodetic techniques. This experiment was designed to directly measure horizontal variations in atmospheric refractivity, for the first time, by using 2 color laser ranging measurements to an aircraft. The 2 color laser system at the Goddard Optical Research Facility (GORF) ranged to a cooperative laser target package on a T-39 aircraft. Circular patterns which extended from the southern edge of the Washington D.C. Beltway to the southern edge of Baltimore, MD were flown counter clockwise around Greenbelt, MD. Successful acquisition, tracking, and ranging for 21 circular paths were achieved on three flights in August 1992, resulting in over 20,000 two color ranging measurements.

Millar, Pamela S.↗

Laser Resonator

An optical resonator cavity configuration has a unitary mirror with oppositely directed convex and concave reflective surfaces disposed into one fold and concertedly reversing both ends of a beam propagating from a laser rod disposed between two total internal reflection prisms. The optical components are rigidly positioned with perpendicularly crossed virtual rooflines by a compact optical bed. The rooflines of the internal reflection prisms, are arranged perpendicularly to the axis of the laser beam and to the optical axes of the optical resonator components.

Harper, L. L.↗

Laser-system model for enhanced operational performance and flexibility on OMEGA EP

The development of laser performance models having real-time prediction capability for the OMEGA EP laser system has been essential in meeting requests from its user community for increasingly complex pulse shapes that span a wide range of energies. The laser operations model PSOPS provides rapid and accurate predictions of OMEGA EP laser-system performance in both forward and backward directions, a user-friendly interface and rapid optimization capability between shots. We describe the model’s features and show how PSOPS has allowed real-time optimization of the laser-system configuration in order to satisfy the demands of rapidly evolving experimental campaign needs. We also discuss several enhancements to laser-system performance accuracy and flexibility enabled by PSOPS.

42 ENGINEERING↗

Laser with optically driven Q-switch

An optically driven interactive Q-switch, i.e., a Q-switch that responds to a short pulse of light, for example, from external light-emitting diodes (LEDs) or diode lasers, is provided for producing an output laser pulse from electronic energy stored in a laser medium. Q-switching is thus achieved on demand by electrically pulsing the light source to produce a pulse of light directed onto a Q-switch medium in the laser cavity. Electronic control of the light pulse from the external source will thus provide not only efficient Q-switching frequency but also independent control of output laser pulse width with a fast rise time for each output laser pulse.

Hemmati, Hamid↗

Laser with optically driven Q-switch

An optically driven interactive Q-switch, i.e., a Q-switch that responds to a short pulse of light, for example, from external light-emitting diodes (LED's) or diode lasers, is provided for producing an output laser pulse from electronic energy stored in a laser medium. Q-switching is thus achieved on demand by electrically pulsing the light source to produce a pulse of light directed onto a Q-switch medium in the laser cavity. Electronic control of the light pulse from the external source will thus provide not only efficient Q-switching frequency but also independent control of output laser pulse width with a fast rise time for each output laser pulse.

Hemmati, Hamid↗

Direct evidence of the dominant role of multiphoton permanent-dipole transitions in strong-field dissociation of NO 2 +

We study laser-induced dissociation of a metastable NO 2+ ion-beam target into N + +O + , focusing on the prominent contribution by molecules breaking parallel to the polarization at high peak laser intensity (~10 15 W/cm 2 ). Our experimental results and time-dependent Schrödinger equation calculations show that, contrary to commonly held intuition that electronic transitions always prevail, the dominant process underlying this highly aligned dissociation is a multiphoton permanent-dipole transition involving only the electronic ground state and leading to its vibrational continuum. Strong-field permanent-dipole transitions should thus be considered generally, as they may play a significant role in other heteronuclear molecules. Moreover, their role should only grow in importance for longer wavelengths, a trending direction in ultrafast laser studies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Towards a direct measurement of the quantum-vacuum Lagrangian coupling coefficients using two counterpropagating super-intense laser pulses

In this paper we will show that photon–photon collision experiments using extreme lasers can provide measurable effects giving fundamental information about the essence of QED, its Lagrangian. A possible scenario with two counterpropagating ultra-intense lasers for an experiment to detect scattering between optical photons is analyzed. We discuss the importance of the pulse widths and waists, the best scenario for overlapping the beams and signal detection, as well as ways to distinguish the signal from the noise. This would need a high-precision measurement, with control of temporal jitter and noise. We conclude that such experiment is barely feasible at 10 23 W cm -2 and very promising at 10 24 W cm -2

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental comparison of heterodyne and direct detection for pulsed differential absorption CO2 lidar

A pulsed dual-wavelength dual-CO2-laser differential-absorption lidar (DIAL) system has been developed which permits simultaneous heterodyne and direct detection of the same lidar returns. This system has been used to make an experimental comparison of the SNRs and statistical and temporal characteristics of the DIAL returns from several topographic targets. These results were found to be in general agreement with theory and were used to quantify the relative merits of the two detection techniques. The measured parameter values were applied to an analytical treatment to predict system trade-offs for the remote sensing of atmospheric species, with application to both path-averaged and range-resolved measurements.

Killinger, D. K.↗

Anomalous Retrograde Drifts in Obstructed Magnetron Microdischarges: a Consequence of a Field Reversal in the Anode Sheath?

The goal of this project was to carry out experiments at the Plasma Collaborative Research Facility (Princeton Plasma Physics Laboratory) aimed at confirming or refuting the hypothesis that an electric field reversal occurs in the near-anode region of a strongly obstructed planar magnetron microdischarges. Magnetron discharges are magnetized plasmas with E x B field topologies, and variants of such discharges are widely used in materials processing. The topologies are also similar to that of Hall thrusters used in space propulsion. Understanding the structure of these discharges will aid in developing reliable simulations that are intended to facilitate the further development of such technologies, as the field reversals, presumed to be due to strong axial-driven electron transport, provides further insight into transport properties. The possible existence of such a field reversal is hinted at because of the retrograde-propagating (i.e., negative E x B) spokes or gradient-driven drift instabilities seen in the high speed videos and segmented anode probing of the plasma. The presence of this field reversal should be reflected in the ion dynamics, particularly, in an ion drift towards the anode. The proposed experiments to be conducted at the PCRF are to characterize this anode-directed ion drift using state-of-the-art laser-induced fluorescence velocimetry. In particular, we seek to see if the near-anode ion velocity reverses direction when the external circuit is varied to alter the electron current demand imposed at the anode. Such an ion velocity reversal would confirm the mechanism, which is that the highly obstructed (small gapped) discharge produces strong axial gradients in plasma density, driving more electrons towards the anode then that demanded by the external circuit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance measurements of a diode laser optical communications link with Q = 4 PPM signaling

The theoretical and measured performance characteristics of a direct detection optical communication system are reported. The system consisted of a semiconductor diode laser, silicon avalanche photodiode detector, and used Q = 4 optical pulse position modulation signaling to transmit binary source data at a rate of 25 megabits/sec. Operation at a receiver bit error probability of 10 to the -6th was demonstrated at received signal energies corresponding to an average of 160 detected photons per PPM symbol, or 80 photons per source bit.

Sun, X.↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intracavity Rayleigh/Mie Scattering for Multipoint, Two-Component Velocity Measurement

A simultaneous multi-point two-component Doppler velocimeter is described. The system uses two optical cavities: a Fabry-Perot etalon and an optical cavity for collecting and re-circulating the Rayleigh/Mie scattered light that is collected from the measurement volume in two parallel, but opposite directions. Single-pulse measurements of two orthogonal components of the velocity vector in a supersonic free jet were performed to demonstrate the technique. The re-circulation of the light rejected by the interferometer input mirror also increased the signal intensity by a factor of 3.5. 2005 Optical Society of America Interferometric Rayleigh scattering has previously been used for single-point velocity measurements in unseeded gas flow. However, this past work has generally been limited to probing with continuous-wave lasers resulting in time-averaged measurements of velocity. Multiple velocity components have been measured simultaneously by separate instruments.1,2 It has also been demonstrated that two orthogonal velocity components can be measured simultaneously at one point using one interferometer by reflecting back the probing laser beam, although this approach results in directional ambiguity of the flow velocity vector.3 This measurement ambiguity was removed by prior knowledge of the approximate magnitude and sign of the velocity components. Furthermore, it was shown that multiple points could be measured simultaneously with a Rayleigh scattering interferometric approach, but only one component of velocity was measured.4 Another method of performing multiple component velocity measurements with Rayleigh scattering uses a pair of cameras to image the flow, one of which views the flow through an iodine gas filter. This iodine-filter technique has the advantage of allowing high-resolution velocity imaging, but it generally has a lower dynamic range.

Bivolaru, Daniel↗

High Throughput Coefficient Thermal Expansion Testing Utilizing Digital Image Correlation

Dr. Fitzgerald, a postdoc at Sandia National Laboratories, works in a materials of mechanics group characterizing material properties of ductile materials. Her presentation focuses specifically on increasing throughput of coefficient of thermal expansion (CTE) measurements with the use of optical strain measurements, called digital image correlation (DIC). Currently, the coefficient of thermal expansion is found through a time intensive process called dilatometry. There are multiple types of dilatometers. One type, a double push rod mechanical dilatometer, uses and LVDT to measure the expansion of a specimen in one direction. It uses a reference material with known properties to determine the CTE of the specimen in question. Testing about 500 samples using the double push rod mechanical dilatometer would take about 2 years if testing Monday through Friday, because the reference material needs to be at a constant temperature and heating must done slowly to ensure no thermal gradients across the rod. A second type, scissors type dilatometer, pinches a sample using a “scissor-like” appendage that also uses a LVDT to measure thermal expansion as the sample is heated. Finally, laser dilatometry, was created to provide a non-contact means to measure thermal expansion. This process greatly reduces the time required to setup a measurement but is still only able to measure one sample at a time. The time required to test 500 samples gets reduced to 3.5 weeks. Additionally, to measure expansion in different directions, multiple lasers must be used. Dr. Fitzgerald solved this conundrum by using an optical measurement technique called digital image correlation to create strain maps in multiple orientations as well as measuring multiple samples at once. Using this technique, Dr. Fitzgerald can test 500 samples, conservatively, in 2 days.

36 MATERIALS SCIENCE↗