Techno-Economic Evaluation of a 600MW Pumped Storage Hydropower Plant using the Pumped Storage Hydropower Valuation Tool

This paper presents a techno-economic evaluation of the proposed 600 MW, 8-hour Craig – Hayden pumped storage hydropower project using the U.S. Department of Energy’s Pumped Storage Hydropower Valuation Tool. The analysis integrates plant technical characteristics, regional grid conditions, and market-based operating assumptions to quantify stacked value streams from energy arbitrage, capacity, ancillary services, transmission congestion relief, and reliability. Both price taker and price influencer frameworks are applied to examine the impact of market participation and system interactions on lifecycle economic performance using Benefit - Cost Analysis and Multi - Criteria Decision Analysis. The results show that the price taker approach provides higher revenue estimates based on exogenous price signals, while the price influencer approach captures production cost savings, renewable curtailment reduction, and market price formation, yielding more conservative but system-representative outcomes. The study demonstrates the strategic value of long-duration PSH for enhancing operational flexibility, resource adequacy, and grid reliability in a high-renewable Western Interconnection.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046↗

Enabling Secure Grid Information Sharing through Hash Calendar-based Blockchain Infrastructures

The power grid is becoming increasingly interconnected, as information from grid operations must be accessible to an array of engineers, grid regulators, and market operators. However, there remain challenges ensuring the appropriate integrity and authenticity of the grid information. While traditional cryptographic protocols, like public key infrastructure, provide security for in-transit communication, they come with key exchanges and cost to get public key certificates from a centralized authority. To address these challenges, this paper demonstrates how a hash calendar-based blockchain can be used to provide improved security for communication with the use of distributed ledgers. It demonstrates the security requirements and threats to this communication, and then provides a theoretic definition of the process. Furthermore, it introduces a use-case of the proposed process within the WSU Smart City Testbed DMS with the Guardtime’s Keyless Signature Infrastructure (KSI) architecture.

Kaur, Kudrat J.↗

A Cyber-Resilience Risk Management Architecture for Distributed Wind

Distributed wind is an electric energy resource segment with strong potential to be deployed in many applications, but special consideration of resilience and cybersecurity is needed to address the unique conditions associated with distributed wind. Distributed wind is a strong candidate to help meet renewable energy and carbon-free energy goals. However, care must be taken as more systems are installed to ensure that the systems are reliable, resilient, and secure. The physical and communications requirements for distributed wind mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity risk management for distributed wind systems specifically. This research develops an architecture for the consideration of cyber risks associated with distributed wind systems. The architecture takes into account the configurations, challenges, and standards for distributed wind to create a risk-focused perspective that considers of threats, vulnerabilities, and consequences, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We discuss common distributed wind architectures and how they are interconnected to larger power systems. Because cybersecurity cannot exist independently, the cyber-resilience architecture must consider the system holistically. Finally, we discuss the implementation of a risk assessment process that uses the cyber-resilience framework to address challenges specific to distributed wind.

17 WIND ENERGY↗

What Role Do Aggregators Play in Power System Security and Resilience?

Barriers to the participation of distributed energy resources (DERs) in wholesale electricity markets have limited the use of DERs for power system security and resilience. In September 2020, the Federal Energy Regulatory Commission (FERC) approved an order to reduce these barriers. FERC Order No. 2222 enables the participation of DER aggregators in wholesale electricity markets. DERs include renewable generation and technologies that support the integration of renewable generation by increasing grid flexibility and resilience. Requiring wholesale energy markets to allow DER aggregator participation provides a path for DERs to become competitive in these markets. As the contribution from aggregated DERs continues to increase, the aggregator's role in supporting grid security and resilience will become more critical. This paper reviews work that demonstrates how DER aggregators can provide resilience support through technical capabilities, operational strategies, and secure communication architectures. Socioeconomic influences and impacts of aggregators, including implications for social resilience, are presented. In surveying the current state-of-the-art across different but interconnected topics, we illustrate how aggregators can be power system participants that enhance grid security. There is no one-size-fits-all approach to enhancing resilience in a power grid that includes a growing cohort of DER aggregators, but there are many options for aggregators to contribute to a more resilient and secure power grid.

aggregator↗

Transmission Data-Driven User-Defined Model for Inverter-based and Conventional Power Plants

Recent events in Odessa [1], [2] have shed light on the complexities of integrating large Inverter-Based Resource (IBR) plants with the transmission system, prompting NERC to stress continuous performance monitoring by transmission operators. Challenges such as plant control updates, IBR model revisions, Phase-locked loop loss of synchronism, and protection events have been identified, underscoring the need for enhanced monitoring protocols by regulatory bodies. The recent FERC 901 order underscores the importance of accurate data exchange regarding IBRs for reliability studies. However, limited access to IBR plant-related data hampers effective decision-making for transmission operators (TOP). This paper proposes a method for constructing data-driven User-Defined dynamic Models (UDM) for power plants for validating multiple-event data using field measurements from interconnection bus locations. The problem is formulated as a power plant model identification problem and a multi-task learning approach under partial input observability assumptions is proposed in this work. This approach aims to predict aggregated responses of conventional and IBR power plants during various dynamic physical events which is useful for planning studies under diverse disturbance conditions. Ultimately, this methodology emphasizes the importance of plant visibility to operators in addressing power system challenges, facilitating improved planning and operational studies.

Mahapatra, Kaveri [BATTELLE (PACIFIC NW LAB)]↗

MDLoader: A Hybrid Model-Driven Data Loader for Distributed Graph Neural Network Training

Scalable data management is essential for processing large scientific dataset on HPC platforms for distributed deep learning. In-memory distributed storage is preferred for its speed, enabling rapid, random, and frequent data access required by stochastic optimizers. Processes use one-sided or collective communication to fetch remote data, with optimal performance depending on (i) dataset characteristics, (ii) training scale, and (iii) interconnection network. Empirical analysis shows collective communication excels with larger mini-batch sizes and/or fewer processes, whereas one-sided communication outperforms at larger scales. We propose MDLoader, a hybrid in-memory data loader for distributed graph neural network training. MDLoader features a model-driven performance estimator that dynamically selects between one-sided and collective communication at the beginning of training using Tree of Parzen Estimators (TPE). Evaluations on NERSC Perlmutter and OLCF Summit show MDLoader outperforms single-backend loaders by up to 2.83 × and predicts the suitable communication method with 96.3% (Perlmutter) and 94.3% (Summit) success rate.

Bae, Jonghyun↗

Destabilizing a Social Network Model via Intrinsic Feedback Vulnerabilities

Social influence plays a significant role in shaping individual sentiments and actions, particularly in a world of ubiquitous digital interconnection. The rapid development of generative artificial intelligence (AI) has given rise to well-founded concerns regarding the potential implementation of radicalization techniques in social media. Motivated by these developments, we present a case study investigating the effects of small but intentional perturbations on a simple social network. We employ Taylor's classic model of social influence and tools from robust control theory (most notably the Dynamical Structure Function (DSF)), to identify perturbations that qualitatively alter the system's behavior while remaining as unobtrusive as possible. We examine two such scenarios: perturbations to an existing link and perturbations that introduce a new link to the network. In each case, we identify destabilizing perturbations of minimal norm and simulate their effects. Remarkably, we find that small but targeted alterations to network structure may lead to the radicalization of all agents, exhibiting the potential for large-scale shifts in collective behavior to be triggered by comparatively minuscule adjustments in social influence. Given that this method of identifying perturbations that are innocuous yet destabilizing applies to any suitable dynamical system, our findings emphasize a need for similar analyses to be carried out on real systems (e.g., real social networks), to identify the places where such dynamics may already exist.

Rogers, Lane [ORNL]↗

Incentivizing Distributed Energy Resource Participation in Grid Services

The bulk power system is experiencing a dramatic shift as renewable generation growth continues to accelerate. Large-scale renewables adoption will help societies transition to a low-carbon, low-cost, and environmentally friendly electrical power system. However, the transition from a paradigm of generation following load to one where load follows generation will require large-scale interconnection and coordinated operation of Distributed Energy Resources (DERs), supported by open communication protocols. In this future grid scenario, DER aggregations will provide critical grid services that enable high penetration levels of renewable generation. This position paper presents an Energy Service Interface (ESI) that defines scope for ensuring secure, trustworthy information exchange between grid service providers and DERs. The goal of the ESI is to encourage large-scale participation of DERs in order to provide grid services through dispatch of DER aggregations. This position paper also presents an open smart energy communications protocol that allows DERs to advertise their characteristics and participate in grid services, within constraints established by the ESI. The paper presents several monetization incentives that grid service providers could use to encourage large-scale DER participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emulation Framework for Distributed Large-Scale Systems Integration

Recent trends in systems engineering include integration of very large-scale systems, which entails significant challenges when they are geographically dispersed. In these scenarios, intelligent integration of distributed large-scale systems requires significant coordination among hardware elements as well as all software components. The approach of integrated systems (both computing platform and experimental equipment) for end-to-end orchestration is called federation. Virtual frameworks can aid in the testing, assessment, and implementation of a functional system of interconnected resources. We present an emulation framework that replicates the software environments of multi-site federations of computing systems and instruments. Our emulation framework allows systems engineers to reduce developmentcost and avoid disruptions to production infrastructure. Our framework was effectively used to develop and test software modules for various tasks including container orchestration and instrument access. For performance assessment, however, the emulated framework is severely limited in providing accurate network and IO measurements at 10 Gbps and higher data rates. The data transfer performance profiles estimated using these emulated measurements are usually inaccurate for high bandwidth and high latency connections, since emulation does not accurately reflect the critical network transport dynamics.We utilize measurements from a physical testbed with hardware network emulators to obtain data transfer profiles that closely match the expected profiles for the emulated federations. We show the effectiveness of our approach by an illustrative example of integrated (federated) multi-site ultra large-scale systems that are connected via high speed wide area networks.

Imam, Neena↗

SuperCIC: Enhanced Winding Current Density for Hybrid Windings of Tokamaks

The design is presented for a new approach to cable-in-conduit (SuperCIC) for use in the high-field windings of tokamaks. Two layers of high-field superconductor wires are cabled onto a thin-wall perforated center tube. An overwrap is applied and the cable is inserted as a loose fit into a sheath tube. The sheath tube is drawn down onto the cable to compress the wires onto the center tube and immobilize them. The SuperCIC is then co-wound with a high-strength armor extrusion, which is kerf-cut so that the co-winding onto a coil mandrel can be made without deformation within the armor or the CIC. SuperCIC facilitates hybrid windings, in which subwindings of NbTi are used where B < 7 T, Nb 3 Sn where B < 14 T, and Bi-2212where B > 14 T to minimize superconductor cost. Demount-able splices are used to interconnect layers. A conceptual design has been prepared for a tokamak with aspect ratio A ~ 2.0, magnetic field of 17.4Tat the inner windings and 6.7 T at the plasma,and winding current density ~140 A/mm 2 -sufficient for optimizing the fusion power density in a compact spherical tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Guest Editorial: Special section on Resilient Control of Cyber-Physical Power and Energy Systems

Our power and energy systems are becoming more and more integrated and interconnected. The increasing integration of edge devices and dependence on cyber infrastructure provides both the potential for benefits and risks. The integration enables more dynamic and flexible control paradigms while at the same time increasing the cyberattack surface and uncertainty of behavior. Control methodology in this new world must be designed for resilience and must have the ability to withstand, react, and respond to both physical faults and cyber-induced threats. Finally, understanding system resilience under adverse conditions requires studying control performance and how cyber infrastructure can integrate with and support the overall resilience of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Integration Study of Converter-Interfaced Combined Heat and Power Plants

Combined Heat and Power (CHP) systems, as a proven technology, provide numerous benefits to the plant owner by saving electricity bill, reducing carbon dioxide emissions, and improving electricity service reliability. However, their integration into the distribution grid faces many barriers including the complexity of grid code requirements and the lack of technical expertise in commercial and small industrial plants to interface with the utility and accelerate the interconnection process. To solve these issues, this study proposes a converter-interfaced solution for CHP integration. Simulations including various fault scenarios and load flow under different grid conditions are carried out to compare technical performances of the proposed solution with directly-coupled CHP. Results show that the generator size of converter-interfaced CHP can be reduced by approximately 25% and it also provides advantageous features such as reduced stress level under fault conditions and a better dynamic stability margin. In addition, a power factor controller is designed and reactive power from CHP is dispatched in such a way that the CHP plant is compliant with power factor requirements from utilities under all operating conditions.

Converter, Combined heat and power, Distributed en↗

Dynamic Frequency Regulation Improvement in Hydropower-Hybrid System using Variational Mode Decomposition

Providing frequency response, especially fast frequency response such as Red D in the Pennsylvania-New Jersey-Maryland Interconnection (PJM) market, is challenging for many generation plants to deliver on their own. If they have adequate flexibility, hydropower plants are typically able to provide slower regulation support (e.g., Reg A in PJM), but do not respond fast enough to provide Reg D. The ability to provide Reg D would improve their revenue because this service is typically more valuable. This work presents a control approach to use hydropower, battery, and ultracapacitor systems to provide fast regulation in a way that uses the response contribution of each asset. In particular, the proposed control architecture applies a variational mode decomposition (VMD) technique on the incoming Reg D signal to extract multiple dynamic-regulation components with non-overlapping frequencies. With the response-speed dependent alignment, these regulation components are fed to the hydrogenator and hybrid energy storage system (HESS). The paper evaluates the proposed approach on a direct-current (DC)-coupled active system by computing several performance measures and analyzing sensitivity based on HESS component proportional capacities. The results reveal that the proposed VMD-based signal conditioning performs well and that optimizing the sizing of the battery and ultracapacitor components further enhances performance.

13 HYDRO ENERGY↗

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

Understanding Regional Inertia Dynamics in CAISO from Real Grid Disturbances

The shift from synchronous generators to inverter-based resources has caused power system inertia to be unevenly distributed across power grids. As a result, certain grid regions are more vulnerable to high rate-of-change of frequency (RoCoF) during disturbances. This paper presents a measurement-based framework for estimating grid inertia in CAISO (California Independent System Operator) region using real disturbance-driven frequency data from the Frequency Monitoring Network (FNET/GridEye). By analyzing confirmed disturbances from 2013 to 2024, we identify trends in regional inertia and frequency dynamics, highlighting their relationship with renewable generation and the evolving duck curve. Regional RoCoF values were up to six times higher than interconnection-wide values, coinciding with declining inertia. Recent recovery in inertia is attributed to the increased deployment of battery energy storage systems with synthetic inertia capabilities. These findings underscore the importance of regional inertia monitoring, strategic resource planning, and adaptive operational practices to ensure grid reliability amid growing renewable integration.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Real-Time Multiregional Market-to-Market Congestion Management Through Exchange of Relief Cost Curve

This paper introduces a novel method for multiregional market-to-market (M2M) coordinated congestion management. It identifies shortcomings in existing M2M approaches, where Regional Transmission Organizations (RTOs) exchange shadow prices and relief requests to optimize congestion relief allocations across interconnected regions. Two methods are proposed to enhance flow and price convergence. The first method proposes that both Regional Transmission Organizations (RTOs) use state-estimator flows directly to determine relief requirements, eliminating delays and potential oscillations caused by using market flows calculated from the prior period under existing M2M approach. The second method involves exchanging transmission relief cost curves, enabling each RTOs to integrate other RTOs' relief costs curve into its real-time security-constrained economic dispatch (SCED). This method can effectively extend the coordination to multiple transmission lines and across more than two RTOs. The alternating direction method of multipliers (ADMM) is also applied to the M2M coordination problem and compared with the proposed methods. Case studies on small and large-scale systems demonstrate the effectiveness of these approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗