Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Efficient Anomaly Detection Driven By Different Machine Learning Architectures And Models

The rapid growth and ubiquitous adoption of the internet and cyber-physical systems (CPS) have fundamentally transformed modern communication, work, and human-system interactions. While networks now form the backbone of critical digital ecosystems, enabling seamless data transmission across diverse, interconnected systems, this increased connectivity also expands the attack surface, making real-time detection of network intrusions and anomalies a pressing challenge. Detecting unusual activities within network infrastructure requires advanced data traffic analysis to differentiate between legitimate and malicious interactions. Traditional approaches to network anomaly detectionâ??such as rule-based and signature-based systemsâ??often depend on predefined patterns to identify known anomalies, limiting their effectiveness against emerging, stealthy, or previously unseen threats. These conventional methods suffer from high false alarm rates and fail to adapt to the ever-evolving nature of network traffic, particularly in large-scale, decentralized environments where data volume, velocity, and variety are constantly increasing. This dissertation presents artificial intelligence (AI)-driven approaches to anomaly detection that leverage graphics processing unit (GPU)-enabled high-performance computing (HPC) platforms for processing massive network traffic data and monitoring the components of cyber-physical systems (CPS) for potentially hazardous conditions. The research advances several key contributions: (1) Designing efficient machine learning techniques for CPS condition monitoring and anomaly detection; (2) enabling federated learning (FL) frameworks that enable distributed detection while preserving data privacy and system resilience; (3) exploring graph-based methodologies combining graph neural networks (GNN) and graph machine learning (ML) approaches for the Internet of Things (IoT) and automotive network security, and (4) performing distributed edge computing optimizations that integrate FL with scalable technologies for reduced communication overhead. Through extensive experiments, these methodologies demonstrate that complex anomaly detection and condition monitoring tasks can be achieved while balancing computational efficiency and detection accuracy through fine-grained network information processing. The frameworks developed in this research establish a robust foundation for network anomaly detection, providing scalable, adaptive, and privacy-preserving solutions for safeguarding CPS and IoT networks in an increasingly interconnected digital landscape. The practical implications of these research findings are significant, as they can inform the development of next-generation network security systems and contribute to the protection of critical infrastructure against sophisticated cyber attacks.

Marfo, William↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architectural scaling tradeoffs in modular 3D bosonic quantum processors

We propose a modular three-dimensional bosonic quantum processor built from repeatable coupled-cavity modules linked by configurable interconnect networks. Using hardware-motivated graph-theoretic measures, we compare nearest-neighbor, hub-based, and hybrid architectures in terms of interconnect count, communication distance, resource concentration, and implementation complexity. Rather than identifying a universally optimal topology, our analysis shows how these architectures redistribute the costs of scaling, including wiring and port requirements, nonlocal communication distance, exposure to shared resources, routing bottlenecks, and scheduling overhead. Case studies of a \(3\times3\) processor and a larger hierarchical architecture further distinguish finite-size performance from asymptotic scaling. The resulting framework provides a systematic basis for evaluating modular three-dimensional bosonic processors and for identifying the device-level parameters required for quantitative hardware design.

Zhu, Shaojiang [Fermilab] (ORCID:0000000293180092)↗

Utility-Scale Solar, 2021 Edition

Berkeley Labs "Utility-Scale Solar", 2021 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2020, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, and interconnection queue data.

2021↗

Benefit Analysis of Long-Duration Energy Storage in Power Systems with High Renewable Energy Shares

The integration of high shares of variable renewable energy raises challenges for the reliability and cost-effectiveness of power systems. The value of long-duration energy storage, which helps address variability in renewable energy supply across days and seasons, is poised to grow significantly as power systems shift to larger shares of variable generation such as wind and solar. This study explores the system-level services and associated benefits of long-duration energy storage on the 2050 Western Interconnection (WI). The operation of the future WI system with 85% renewable penetration is simulated using a two-stage production cost model. The impact of long duration energy storage on systemwide operations is examined for the 2050 WI system, using a range of round-trip efficiencies corresponding to four different energy storage technologies. The analysis projects the energy storage dispatch profile, system-wide production cost savings (from both diurnal and seasonal operation), and impacts on generation mix, and change in renewable generation curtailment.

25 ENERGY STORAGE↗

Dynamic Behavior of Spatially Confined Sn Clusters and Its Application in Highly Efficient Sodium Storage with High Initial Coulombic Efficiency

Advanced battery electrodes require a cautious design of microscale particles with built-in nanoscale features to exploit the advantages of both micro- and nano-particles relative to their performance attributes. Herein, the dynamic behavior of nanosized Sn clusters and their host pores in carbon nanofiber) during sodiation and desodiation is revealed using a state-of-the-art 3D electron microscopic reconstruction technique. For the first time, the anomalous expansion of Sn clusters after desodiation is observed owing to the aggregation of clusters/single atoms. Pore connectivity is retained despite the anomalous expansion, suggesting inhibition of solid electrolyte interface formation in the sub-2-nm pores. Taking advantage of the built-in nanoconfinement feature, the CNF film with nanometer-sized interconnected pores hosting Sn clusters (≈2 nm) enables high utilization (95% at a high rate of 1 A g –1 ) of Sn active sites while maintaining an improved initial Coulombic efficiency of 87%. Finally, the findings provide insights into electrochemical reactions in a confined space and a guiding principle in electrode design for battery applications.

36 MATERIALS SCIENCE↗

Conductive spinels derived from Co–Mn based alloy precursor for SOFC cathode-side contact application

The utilization of gas-atomized Co–Mn based alloy precursor is a promising approach to lowering the sintering temperature of the spinel contact layer and enhancing its performance. In this work, simulated interconnect/contact/cathode cells are employed to investigate the effects of different metallic precursors (i.e., three Co–Mn based alloy powders and a mixture of Co + MnO 2 powders) on the microstructure and performance of the reactively-sintered MnCo 2 O 4 -based contact layer. While excellent overall electrical performance is observed for all the cells with the four contact precursors during 1000-h testing at 800 °C in air, the cell with the Ce-doped alloy contact precursor shows the lowest cell area specific resistance (ASR) and ASR degradation rate. Cross-sectional observation of the tested cells is conducted to assess the compatibility of the contact layer with adjacent components as well as its effectiveness in reducing the Cr 2 O 3 scale growth and blocking Cr migration from the interconnect to the cathode.

08 HYDROGEN↗

An investigation of the failure modes in U-10Mo monolithic fuel irradiated to high burnup

Here, this study investigated possible failure mode sequences in U-10Mo monolithic fuel irradiated to very-high-burnup. The U-Mo fuel plate used in this study was characterized using scanning electron microscopy (SEM), wavelength dispersive spectroscopy (WDS), and image analysis techniques to investigate how microstructural features may initiate crack formation and propagation through the microstructure, potentially leading to blistering. Distinctly large fission gas pores (FGPs) were observed to preferentially align 5-15µm away from the U-10Mo/Zr interface, parallel to the Zr diffusion barrier. Preferential growth, alignment, and interconnection of FGP could initiate blistering in the fuel plate by creating a fission gas channel, parallel to the U-Mo/Zr interface. FGP alignment in the fuel phase near the U-Mo/Zr interface is believed to be one of the precursors to crack and Type 2 blister formation in monolithic U-Mo fuels. The chemical maps revealed differences in fission product behavior near the U-Mo/Zr interface such that Nd remains in the fuel matrix at the FGP sites. On the other hand, other fission products like Xe and Cs can get trapped in FGPs by Nd in the fuel phase and/or diffuse toward the Zr diffusion barrier.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mix and match light absorbers

Here, perovskite and organic semiconductors can be combined to make tandem solar cells but, to date, their efficiency has hovered around 20%. Now, researchers demonstrate a 23.6% tandem by reducing interfacial defects to improve the perovskite cell's voltage and developing an ultrathin interconnection layer.

14 SOLAR ENERGY↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Frontier (HPE Cray EX) Exascale Supercomputer at the Oak Ridge Leadership Computing Facility

Frontier is the HPE Cray EX exascale supercomputer deployed and operated by the Oak Ridge Leadership Computing Facility (OLCF) at Oak Ridge National Laboratory (ORNL). Frontier is designed for large-scale modeling, simulation, and AI workloads and is built from HPE Cray EX system architecture with AMD CPUs and AMD Instinct GPU accelerators connected by the HPE Slingshot interconnect. System composition (representative production configuration): Frontier is composed of approximately 74 cabinets with 128 compute nodes per cabinet (~9,400 compute nodes total). Each compute node contains one 64-core AMD EPYC CPU and four AMD Instinct MI250X GPUs. Nodes are connected using HPE Slingshot (Slingshot-200 class) networking with multiple NIC ports per node providing high injection bandwidth. Frontier is connected to the Orion parallel file system (multi-tier Lustre) providing a large, center-wide high-performance storage namespace. Operational context: Frontier entered public prominence as the first system to reach No. 1 on the TOP500 list in May 2022 (HPL benchmark), establishing the first widely recognized exascale-era performance milestone. The system supports DOE Office of Science mission workloads and enables leadership-class computational science and AI for open science users.

AMD EPYC↗

Clause-by-Clause Summary of Requirements in IEEE Standard 1547-2018

The revised IEEE 1547 standard (IEEE Std 1547-2018) contains eleven chapters (clauses) and eight annexes that comprise 136 pages. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of distributed energy resources to the electric power system. Implementation of the requirements needs a careful study of the underlying technical concept and also needs the appropriate information that may be required to calculate various settings and configurations. This document aims to provide an introductory text to assist users of IEEE Std 1547-2018 in identifying the following questions: what is the primary audience of the clause/subclause? What knowledge is required to understand the technical subject matter? What information is required to apply/implement the requirements specified? What level of fluency with the subject matter is required to apply/implement the requirements?

24 POWER TRANSMISSION AND DISTRIBUTION↗

Minnesota Solar Pathways: Illuminating Pathways to 10% Solar (Final Technical Report)

The Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, was a three-year project designed to explore least-risk, best-value strategies for meeting the State of Minnesota’s solar goals. As part of this aim, the Pathways Team modeled renewable generation costs, examined ways to streamline interconnection, and evaluated technologies that can increase solar hosting capacity on the distribution grid. Midway through the project period, the Pathways Team expanded the scope of study using the same modeling framework from the Minnesota Solar Potential Analysis to estimate and compare generation costs for high renewables penetration scenarios across the Midcontinent Independent System Operator (MISO) region. The analysis concludes that it can be cheaper to overbuild solar + wind and curtail surplus than to store all generation. In addition, the analysis of individual MISO subregions compared with the whole region highlights the opportunities of enabling market potential compared with impact of ongoing transmission constraints. Beyond the analysis of future scenarios, the partnerships initiated and supported through this project underscored the ongoing need for work with stakeholders to address key issues, particularly around siting, and leverage symbiotic strategies to meet state goals.

14 SOLAR ENERGY↗

Key Considerations for Adoption of Technical Codes and Standards for Battery Energy Storage Systems in Thailand

Battery storage is “technology that enables power system operators and utilities to store energy for later use. A battery energy storage system (BESS) is an electrochemical device that charges (or collects energy) from the grid or a power plant and then discharges that energy at a later time to provide electricity or other grid services when needed”. As countries in Asia consider the inclusion of BESS in their power systems to meet policy objectives, renewable energy goals, increase resilience, and expand energy access, there is an opportunity to learn from the experiences of other regions and jurisdictions that have developed more advanced storage markets and deployment methodologies. This report presents global best practices of codes, standards, and interconnection procedures developed to support the safe and reliable deployment of BESS. Several relevant case studies highlight current efforts to ensure safe operation of BESS and showcase potential pathways for adoption of relevant codes and standards. Specifically, this report is intended to support the Thailand Office of Energy Regulatory Commission (OERC) and other stakeholders in their efforts to develop technical codes and standards to govern the installation and operation of BESS; it may also be utilized as a guide for other countries as interest in the deployment of BESS technologies continues to grow.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ribbons Affect Movement of Cracked Solar Cells [Poster]

Cracking of crystalline silicon photovoltaic cells remains a challenging topic in accurately assessing the long-term reliability and performance of affected modules. Cells can be damaged in every stage throughout the lifetime of a photovoltaic module, ranging from manufacturing, transportation, and installation to operation. Initially, the metallization can be able to bridge the gap of fractured cells and keep individual cell fragments electrically connected. However, photovoltaic modules and cells experience thermo-mechanical stresses during operation from temperature changes and pressure cycles of wind and snow loads. This causes the cell fragments to move, which, in turn, can lead to the wear out of the metallization and, consequently, to power loss or a safety hazard. The rate at which this degradation mechanism proceeds is currently unknown. Hence, in this work, we quantify the cell fragment movement of polycrystalline and monocrystalline mini-modules. By using digital image correlation, we were able to extract the normal crack opening and tangential sliding distances of adjacent cell fragments during heating of the mini-modules. Those distances are essential to develop wear-out models for the metallization and determine the rate of the degradation mechanism. We found that the interconnect technology has a significant impact on the direction and quantity of the cell fragment movements.

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗