Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

A Broadband X-Ray Imaging Spectroscopy with High-Angular Resolution: the FORCE Mission

We are proposing FORCE (Focusing On Relativistic universe and Cosmic Evolution) as a future Japan-lead X-ray observatory to be launched in the mid 2020s. Hitomi (ASTRO-H) possesses a suite of sensitive instruments enabling the highest energy-resolution spectroscopy in soft X-ray band, a broadband X-ray imaging spectroscopy in soft and hard X-ray bands, and further high energy coverage up to soft gamma-ray band. FORCE is the direct successor to the broadband X-ray imaging spectroscopy aspect of Hitomi (ASTRO-H) with significantly higher angular resolution. The current design of FORCE defines energy band pass of 1-80 keV with angular resolution of <15" in half-power diameter, achieving a 10 times higher sensitivity above 10 keV compared to any previous missions with simultaneous soft X-ray coverage. Our primary scientific objective is to trace the cosmic formation history by searching for "missing black holes" in various mass-scales: "buried supermassive black holes (SMBHs)" (> 10(exp 4) Stellar Mass) residing in the center of galaxies in a cosmological distance, "intermediate-mass black holes" (10(exp 2)-(10(exp 4) Stellar Mass) acting as the possible seeds from which SMBHs grow, and "orphan stellar-mass black holes" (< 10(exp 2) Stellar Mass) without companion in our Galaxy. In addition to these missing BHs, hunting for the nature of relativistic particles at various astrophysical shocks is also in our scope, utilizing the broadband X-ray coverage with high angular-resolution. FORCE are going to open a new era in these fields. The satellite is proposed to be launched with the Epsilon vehicle that is a Japanese current solid-fuel rocket. FORCE carries three identical pairs of Super-mirror and wide-band X-ray detector. The focal length is currently planned to be 10 m. The silicon mirror with multi-layer coating is our primary choice to achieve lightweight, good angular optics. The detector is a descendant of hard X-ray imager onboard Hitomi (ASTRO-H) replacing its silicon strip detector with SOI-CMOS silicon pixel detector, allowing an extension of the low energy threshold down to 1 keV or even less.

Hard X-ray↗

Multispectral imaging and analysis system

Arrays of charge coupled devices or linear detector arrays simultaneously obtain spectral reflectance data of different wavelengths for a target area. Several accommodating a particular bandwidth, are individually associated with each array. Data from the arrays are read out in parallel and applied to a computer or microprocessor for processing. The microprocessor serves to analyze the data in real time and if possible, in accordance with hard-wired algorithms. The data are then displayed as an image on an appropriate display unit and also recorded for further use. The display system may be operationally connected to receive a terrain image such that the target area and the analyzed spectral reflectance data are superimposed and simultaneously displayed.

Goetz, A. F. H.↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

MegaMIR: The Megapixel Mid-Infrared Instrument for the Large Binocular Telescope Interferometer

The Megapixel Mid-infrared Instrument (MegaMIR) is a proposed Fizeau-mode camera for the Large Binocular Telescope operating at wavelengths between 5 and 28 micrometers. The camera will be used in conjunction with the Large Binocular Telescope Interferometer (LBTI), a cryogenic optical system that combines the beams from twin 8.4-m telescopes in a phase coherent manner. Unlike other interferometric systems, the co-mounted telescopes on the LBT satisfy the sine condition, providing diffraction-limited resolution over the 40" field of view of the camera. With a 22.8-m baseline, MegaMIR will yield 0.1" angular resolution, making it the highest resolution wide field imager in the thermal infrared for at least the next decade. MegaMIR will utilize a newly developed 1024 x 1024 pixel Si:As detector array that has been optimized for use at high backgrounds. This new detector is a derivative of the Wide-field Infrared Survey Explorer (WISE) low-background detector. The combination of high angular resolution and wide field imaging will be a unique scientific capability for astronomy. Key benefits will be realized in planetary science, galactic, and extra-galactic astronomy. High angular resolution is essential to disentangle highly complex sources, particularly in star formation regions and external galaxies, and MegaMIR provides this performance over a full field of view. Because of the great impact being made by space observatories like the Spitzer Space Telescope, the number of available targets for study has greatly increased in recent years, and MegaMIR will allow efficient follow up science.

ultraluminous galaxies↗

LBNF/DUNE Cryostats and Cryogenics Infrastructure for the DUNE Far Detector (Design Report)

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on both a near detector and a cryogenic far detector. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines many tens-of-kilotons of fiducial mass with sub-centimeter spatial resolution to collect neutrino events and image them with high precision. Given its size, this detector will be implemented as a set of up to four modules, each of which will require its own cryostat that will contain approximately 17.5 metric kilotons of ultra-pure liquid argon (LAr). The cryogenics infrastructure to support the detector modules includes systems to receive, transfer, store, purify, and maintain the LAr. This design report describes the cryostats and the cryogenics infrastructure required for the first two detector modules; this infrastructure is designed to support expansion to up to four far detector modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Format Arrays for Far Infrared and Millimeter Astronomy

Some of the most compelling questions in modem astronomy are best addressed with submillimeter and millimeter observations. The question of the role of inflation in the early evolution of the universe is best addressed with large sensitive arrays of millimeter polarimeters. The study of the first generations of galaxies requires sensitive submillimeter imaging, which can help us to understand the history of energy release and nucleosynthesis in the universe. Our ability to address these questions is dramatically increasing, driven by dramatic steps in the sensitivity and size of available detector arrays. While the MIPS instrument on the SIRTF mission will revolutionize far infrared astronomy with its 1024 element array of photoconductors, thermal detectors remain the dominant technology for submillimeter and millimeter imaging and polarimetry. The last decade has seen the deployment of increasingly large arrays of bolometers, ranging from the 48 element arrays deployed on the KAO in the late 198Os, to the SHARC and SCUBA arrays in the 1990s. The past years have seen the deployment of a new generation of larger detector arrays in SHARC II (384 channels) and Bolocam (144 channels). These detectors are in operation and are beginning to make significant impacts on the field. Arrays of sensitive submillimeter bolometers on the SPIRE instrument on Herschel will allow the first large areas surveys of the sky, providing important insight into the evolution of galaxies. The next generation of detectors, led by SCUBA II, will increase the focal scale of these instruments by an order of magnitude. Two major missions are being planned by NASA for which further development of long wavelength detectors is essential, The SAFlR mission, a 10-m class telescope with large arrays of background limited detectors, will extend our reach into the epoch of initial galaxy formation. A major goal of modem cosmology is to test the inflationary paradigm in the early evolution of the universe. To this end, a mission is planned to detect the imprint of inflation on the CMB by precision measurement of its polarization. This work requires very large arrays of sensitive detectors which can provide unprecedented control of a wide range of systematic errors, given the small amplitude of the signal of interest. We will describe the current state of large format detector arrays, the performance requirements set by the new missions, and the different approaches being developed in the community to meet these requirements. We are confident that within a decade, these developments will lead to dramatic advances in our understanding of the evolution of the universe.

Moseley, Harvey↗

Efficient photoconductive terahertz detection through photon trapping in plasmonic nanocavities

We present a photoconductive terahertz detector that employs a plasmonic nanocavity to offer high-sensitivity and broadband operation when used in a terahertz time-domain spectroscopy system even at very low optical pump power levels. By employing a plasmonic nanocavity, all of the photocarriers are generated within a 100 nm distance from the photoconductor contact electrodes, enabling a short transport time for almost all of the photogenerated carriers. As a result, the photoconductive detector maintains high quantum efficiency and ultrafast operation simultaneously, enabling high-sensitivity and broadband operation at very low optical pump power levels. We utilize a photoconductive detector based on a plasmonic nanocavity optimized for operation at a 770 nm optical wavelength in a terahertz time-domain spectroscopy system and demonstrate a 100 dB signal-to-noise ratio and a 0.1–6 THz noise-equivalent bandwidth at a record-low average optical pump power of 0.1 mW, compared to the state-of-the-art photoconductive terahertz detectors. The extremely low optical power budget of the demonstrated photoconductive detector makes this detector attractive for multi-pixel terahertz imaging systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Search for very-short-baseline oscillations of reactor antineutrinos with the SoLid detector

In this paper we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, polyvinyl toluene (PVT) and Li 6 F : ZnS ( Ag ) , to measure antineutrinos via their inverse- β -decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12 800 voxels and operates over a very short 6.3–8.9 m baseline from the reactor core. The detector segmentation and its three-dimensional imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilized for signal-background discrimination. We present a result obtained from 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data taking. A total of 29 479 ± 603 (stat) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Highly efficient visible and near-IR photon pair generation with thin-film lithium niobate

Efficient on-chip entangled photon pair generation at telecom wavelengths is an integral aspect of emerging quantum optical technologies, particularly for quantum communication and computing. However, moving to shorter wavelengths enables the use of more accessible silicon detector technology, and opens up applications in imaging and spectroscopy. Here, we present high brightness ((1.6 ± 0.3) × 10 9 pairs/s/mW/nm) visible–near-IR photon pair generation in a periodically poled lithium niobate nanophotonic waveguide. The degenerate spectrum of the photon pairs is centered at 811 nm with a bandwidth of 117 nm when pumped with a spectrally multimode laser diode. The measured on-chip source efficiency of (2.3 ± 0.5) × 10 11 pairs/s/mW is on par with source efficiencies at telecom wavelengths and is also orders of magnitude higher than the efficiencies of other visible sources implemented in bulk crystal or diffused waveguide-based technologies. Further improvements in the brightness and efficiencies are possible by pumping the device with a single-frequency laser, which would also shrink the pair bandwidth. These results represent the shortest wavelength of photon pairs generated in a nanophotonic waveguide reported to date by nearly an octave.

42 ENGINEERING↗

NUMI Flux Systematic Uncertainties

The Imaging Cosmic And Rare Underground Signals (ICARUS) detector is a 476 t active liquid argon time projection chamber neutrino detector at Fermilab. ICARUS lies 795 m downstream and 5.75◦ off-axis from the Neutrinos at the Main Injector (NuMI) beam. To create a neutrino beam NuMI directs pulsed beam of 120 GeV protons onto a graphite target to create hadrons, which are then focused by magnetic horns and allowed to decay into neutrinos. At the ICARUS off-axis angle the neutrino flux originates from the decays of unfocused/antifocused pions decays and from high-transverse momentum kaon decays. These contributions allow ICARUS to observe a significant flux of (anti-)electron and (anti-)muon neutrinos in a kinematic region relevant to the upcoming DUNE experiment. These factors also introduce various model uncertainties that have not been studied in detail by existing on-axis experiments. This poster will explore the systematic uncertainties in the NuMI flux at ICARUS that arise from uncertainties on hadron interaction cross sections and beamline operation conditions.

Alrahman, Fatima Abd [Houston U.]↗

The Roman View of Strong Gravitational Lenses

Galaxy–galaxy strong gravitational lenses can constrain dark matter models and the Lambda cold dark matter cosmological paradigm at subgalactic scales. Currently, there is a dearth of images of these rare systems with high signal-to-noise ratio (SNR) and angular resolution. The Nancy Grace Roman Space Telescope (hereafter Roman), scheduled for launch in late 2026, will play a transformative role in strong-lensing science with its planned wide-field surveys. With its remarkable 0.281 square degree field of view and diffraction-limited angular resolution of ~0$^{''}_.$1, Roman is uniquely suited to characterizing dark matter substructure from a robust population of strong lenses. We present a yield simulation of detectable strong lenses in Roman’s planned High Latitude Wide Area Survey (HLWAS). We simulate a population of galaxy–galaxy strong lenses across cosmic time with cold dark matter subhalo populations, select those detectable in the HLWAS, and generate simulated images accounting for realistic Wide Field Instrument detector effects. For a fiducial case of single 146 s exposures, we predict around 160,000 detectable strong lenses in the HLWAS, of which about 500 will have sufficient SNR to be amenable to detailed substructure characterization. We investigate the effect of variation of the point-spread function across Roman’s field of view on detecting individual subhalos and the suppression of the subhalo mass function at low masses. Our simulation products are available to support strong-lens science with Roman, such as training neural networks and validating dark matter substructure analysis pipelines.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical infrared sky survey instrumentation

An unusual, highly modified, Baker reflector-corrector class telescope has been adapted for wide field survey photography in the near infrared. This optical system uses a full field corrector plate and a field flattening lens to provide a flat field subtending about 4.5 deg on the sky. The small aperture telescope (20 inch primary) has been modified for use in the Newtonian focus configuration while preserving the optical elements of the Prime focus configuration. The telescope has been further modified to accept a very large format (146mm diameter photocathode) image intensifier camera to serve as a detector. The camera output is recorded photographically on film rather than glass plates. This unique instrument system is used in a program of sky survey photography in the optical infrared (8000-9000A bandpass) supplemented by visual bandpass photography. The photographs obtained with this system are of value not only for the extreme redness of the band but also because of their high resolution and their freedom from hydrogen emission.

Craine, E. R.↗

Pioneer: First to Jupiter, Saturn, and beyond. Bibliography

The reference citatons are grouped by experiment. Experiments include: the charged particle instrument experiment; the ultraviolet photometer experiment; imaging experiments; and magnetometer experiments. The asteroid detector experiment and the plasma analyser experiment are also included.

Source record↗

A concept for a future ground control data set for image correction

Strips of ground control can be established with current and future satellite sensors. These can provide precise and reliable geometric references for locating and correcting satellite image data and to support temporal image registration. This paper briefly describes the concept and approach for implementing this data base called a Ground Control Strip, and recommends additional work. The advent of new solid state imaging systems, in particular the linear array detectors (pushbroom sensors), make this new concept particularly attractive and practical.

Bernstein, R.↗

Aligning the transmitter and receiver telescopes of an infrared lidar A novel method

A method for aligning the transmitter and receiver telescopes of a lidar is proposed which involves the use of a small high-quality corner tube reflector placed immediately in front of the transmitter in such a way that a small fraction of the transmitted radiation is reflected to the receiver. The reflected radiation is brought to a focus in a focal plane where it appears as a small red dot and is superimposed on the image of the distant scene. The dot and the target appear in the same plane and may be brought to coincidence by moving the transmitter-receiver pair together until the image of the target falls on the red dot. The alignment is concluded by imaging the red dot onto an IR detector.

Oppenheim, U. P.↗