National Energy Audit Tool for Multifamily Buildings — Development Plan

The U.S. Department of Energy's (DOE's) Weatherization Assistance Program (WAP) enables low-income families to reduce their energy costs by providing funds to make their homes more energy efficient. In addition, the program funds Weatherization Training and Technical Assistance (T and TA) activities to support a range of program operations. These activities include measuring and documenting performance, monitoring programs, promoting advanced techniques and collaborations to further improve program effectiveness, and training, including developing tools and information resources. The T and TA plan outlines the tasks, activities, and milestones to support the weatherization network with the program implementation ramp up efforts. Weatherization of multifamily buildings has been recognized as an effective way to ramp up weatherization efforts. To support this effort, the 2009 National Weatherization T and TA plan includes the task of expanding the functionality of the Weatherization Assistant, a DOE-sponsored family of energy audit computer programs, to perform audits for large and small multifamily buildings This report describes the planning effort for a new multifamily energy audit tool for DOE's WAP. The functionality of the Weatherization Assistant is being expanded to also perform energy audits of small multifamily and large multifamily buildings. The process covers an assessment of needs that includes input from national experts during two national Web conferences. The assessment of needs is then translated into capability and performance descriptions for the proposed new multifamily energy audit, with some description of what might or should be provided in the new tool. The assessment of needs is combined with our best judgment to lay out a strategy for development of the multifamily tool that proceeds in stages, with features of an initial tool (version 1) and a more capable version 2 handled with currently available resources. Additional development in the future is expected to be needed if more capabilities are to be added. A rough schedule for development of the version 1 tool is presented. The components and capabilities described in this plan will serve as the starting point for development of the proposed new multifamily energy audit tool for WAP.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Northwest Energy Efficient Manufactured Housing Program Specification Development

The DOE research team Building America Partnership for Improved Residential Construction (BA-PIRC), Bonneville Power Administration (BPA), and Northwest Energy Works (NEW), the current Northwest Energy Efficient Manufactured Home Program (NEEM) program administrator, collaborated to research a new specification that would reduce the energy requirements of a NEEM home.This research identified and developed combinations of cost-effective high performance building assemblies and mechanical systems that can readily can be deployed in the manufacturing setting that reduce energy used for space conditioning, water heating and lighting by 50% over the present NEEM specifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

03 NATURAL GAS↗

Residential Facade Retrofits Modeling: Results and Documentation

Utilizing NREL's ResStock analysis tool and datasets, we performed an economic analysis for various facade upgrade combinations and strategies. This analysis considers the combined life-cycle cost of re-siding and window and insulation upgrades including both home value impacts and recurring bill savings estimates from a ResStock analysis, for varying years of home ownership.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data (Revised)

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high-performance water heaters difficult to justify economically. However, recent advancements in high-performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high-efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands.

Building America↗

Excavationless Exterior Foundation Insulation Field Study - Minnesota

The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. Two houses were originally selected for this field study. One was not ready for retrofit at the time of study and had to be eliminated. The collaborative nature of the one field installation, however, enabled the team to advance the methodology as the work progressed. Improvements to the method of installation and reduction of costs were developed on site. This is a repository for all "excavationless" foundation insulation retrofit projects performed by the NorthernSTAR research team. Minneapolis, MN 55411 - Test house for first NorthernSTAR excavationless foundation insulation retrofit.

Array↗

Development of a Roof Savings Calculator

A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned and can provide annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof types at arbitrary inclinations. There are options for above sheathing ventilation, radiant barriers and low-emittance surfaces. The tool also accommodates HVAC ducts either in the conditioned space or in the attic with custom air leakage rates. Multiple layers of thermal mass, ceiling insulation and other parameters can be compared side-by-side to generate energy/cost savings between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft Irwin, CA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light as a Reactive Countermeasure to Sleep Inertia: Translating Laboratory Findings to the Field

Sleep inertia describes the brief period of impaired alertness, mood, and cognitive performance experienced after waking. Under laboratory settings, light exposure upon waking during a habitual sleep period has been shown to improve sleep inertia symptoms. We investigated whether a field-deployable light-emitting device would help to mitigate sleep inertia in a real-world setting. Thirty-six participants (18 female; 26.6 years ± 6.1) completed an at-home, within-subject, randomized crossover study. Participants followed their habitual sleep-wake schedule for five nights before an adaptation and experimental night. Forty-five minutes after bedtime on the experimental night, participants received a phone call and were instructed to wear light-emitting glasses with the light either on (light condition) or off (control). A 5-minute psychomotor vigilance task (PVT), the Karolinska Sleepiness Scale (KSS), visual analog scales of mood (VASmood), and a 3-minute descending subtraction task (DST) were performed starting at +2, +12, +22, and +32 minutes after the call. Participants then went back to sleep and were called 45 minutes after lights out for the opposite condition. A series of mixed-effects models were performed with fixed effects of test bout, condition, test bout × condition, and a random effect of participant. Covariates included pre-sleep baseline scores, randomization order, sex, and sleep history. Participants rated themselves as more alert and energetic in the light condition compared to the control condition (VASalert-sleepy p = .01; VASlethargic-energetic p = .001). There was no effect of condition for DST outcomes, but there was a significant improvement in DST total responses in the light condition in a subset of participants waking from N3 (p = .03). There was a significant effect of condition for PVT outcomes, with faster responses (p < .001) and fewer lapses (p < .001) in the control condition. Our results under naturalistic at-home settings suggest that, similar to the in-laboratory study findings, the light intervention improved subjective alertness and mood, while working memory improved after waking from N3. Future studies of light interventions should include measures of visual acuity and comfort to assess the full feasibility and efficacy of interventions in real-world environments.

sleep inertia↗

Light as a Reactive Countermeasure to Sleep Inertia: Translating Laboratory Findings to the Field

Sleep inertia describes the brief period of impaired alertness, mood, and cognitive performance experienced after waking. Under laboratory settings, light exposure upon waking during a habitual sleep period has been shown to improve sleep inertia symptoms. We investigated whether a field-deployable light-emitting device would help to mitigate sleep inertia in a real-world setting.\ Thirty-six participants (18 female; 26.6 years ± 6.1) completed an at-home, within-subject, randomized crossover study. Participants followed their habitual sleep-wake schedule for five nights before an adaptation and experimental night. Forty-five minutes after bedtime on the experimental night, participants received a phone call and were instructed to wear light-emitting glasses with the light either on (light condition) or off (control). A 5-minute psychomotor vigilance task (PVT), the Karolinska Sleepiness Scale (KSS), visual analog scales of mood (VASmood), and a 3-minute descending subtraction task (DST) were performed starting at +2, +12, +22, and +32 minutes after the call. Participants then went back to sleep and were called 45 minutes after lights out for the opposite condition. A series of mixed-effects models were performed with fixed effects of test bout, condition, test bout × condition, and a random effect of participant. Covariates included pre-sleep baseline scores, randomization order, sex, and sleep history. Participants rated themselves as more alert and energetic in the light condition compared to the control condition (VASalert-sleepy p = .01; VASlethargic-energetic p = .001). There was no effect of condition for DST outcomes, but there was a significant improvement in DST total responses in the light condition in a subset of participants waking from N3 (p = .03). There was a significant effect of condition for PVT outcomes, with faster responses (p < .001) and fewer lapses (p < .001) in the control condition. Our results under naturalistic at-home settings suggest that, similar to the in-laboratory study findings, the light intervention improved subjective alertness and mood, while working memory improved after waking from N3. Future studies of light interventions should include measures of visual acuity and comfort to assess the full feasibility and efficacy of interventions in real-world environments.

sleep inertia↗

Light as a Reactive Countermeasure to Sleep Inertia: Translating Laboratory Findings to the Field

Sleep inertia describes the brief period of impaired alertness, mood, and cognitive performance experienced after waking. Under laboratory settings, light exposure upon waking during a habitual sleep period has been shown to improve sleep inertia symptoms. We investigated whether a field-deployable light-emitting device would help to mitigate sleep inertia in a real-world setting. Thirty-six participants (18 female; 26.6 years ± 6.1) completed an at-home, within-subject, randomized crossover study. Participants followed their habitual sleep-wake schedule for five nights before an adaptation and experimental night. Forty-five minutes after bedtime on the experimental night, participants received a phone call and were instructed to wear light-emitting glasses with the light either on (light condition) or off (control). A 5-minute psychomotor vigilance task (PVT), the Karolinska Sleepiness Scale (KSS), visual analog scales of mood (VASmood), and a 3-minute descending subtraction task (DST) were performed starting at +2, +12, +22, and +32 minutes after the call. Participants then went back to sleep and were called 45 minutes after lights out for the opposite condition. A series of mixed-effects models were performed with fixed effects of test bout, condition, test bout × condition, and a random effect of participant. Covariates included pre-sleep baseline scores, randomization order, sex, and sleep history. Participants rated themselves as more alert and energetic in the light condition compared to the control condition (VASalert-sleepy p = .01; VASlethargic-energetic p = .001). There was no effect of condition for DST outcomes, but there was a significant improvement in DST total responses in the light condition in a subset of participants waking from N3 (p = .03). There was a significant effect of condition for PVT outcomes, with faster responses (p < .001) and fewer lapses (p < .001) in the control condition. Our results under naturalistic at-home settings suggest that, similar to the in-laboratory study findings, the light intervention improved subjective alertness and mood, while working memory improved after waking from N3. Future studies of light interventions should include measures of visual acuity and comfort to assess the full feasibility and efficacy of interventions in real-world environments.

sleep inertia↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DiskDetective.org: Finding Homes for Exoplanets Through Citizen Science

The Disk Detective project is scouring the data archive from the WISE all-sky survey to find new debris disks and protoplanetary disks-the dusty dens where exoplanets form and dwell. Volunteers on this citizen science website have already performed 1.6 million classifications, searching a catalog 8x the size of any published WISE survey. We follow up candidates using ground based telescopes in California, Arizona, Chile, Hawaii, and Argentina. We ultimately expect to increase the pool of known debris disks by approx. 400 and triple the solid angle in clusters of young stars examined with WISE, providing a unique new catalog of isolated disk stars, key planet-search targets, and candidate advanced extraterrestrial civilizations. Come to this talk to hear the news about our latest dusty discoveries and the trials and the ecstasy of launching a new citizen science project. Please bring your laptop or smartphone if you like!

debris disks↗

Performance Benefits Associated with Context-Dependent Arm Pointing Adaptation

Our previous work has demonstrated that head orientation can be used as a contextual cue to switch between mUltiple adaptive states. Subjects were assigned to one of three groups: the head orientation group tilted the head towards the right shoulder when drawing under a 0.5 gain of display and towards the left shoulder when drawing under a 1.5 gain of display; the target orientation group had the home & target positions rotated counterclockwise when drawing under the 0.5 gain and clockwise for the l.5 gain; the arm posture group changed the elbow angle of the arm they were not drawing with from full flexion to full extension with 0.5 and l.5 gain display changes. The head orientation cue was effectively associated with the multiple gains, in comparison to the control conditions. The purpose of the current investigation was to determine whether this context-dependent adaptation results in any savings in terms of performance measures such as movement duration and movement smoothness when subjects switch between multiple adaptive states. Subjects in the head adaptation group demonstrated reduced movement duration and increased movement smoothness (measured via normalized j erk scores) in comparison to the two control groups when switching between the 0.5 and 1.5 gain. of display. This work has demonstrated not only that subjects can acquire context-dependent adaptation, but also that it results in a significant savings of performance upon transfer between adaptive states

Seidler, R. D.↗