Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic solution for low carbon process heat: A horizontal, compact high temperature gas reactor

In 2018, nuclear energy generated 55% of United States’ and one third of the world’s carbon free electricity, making nuclear energy a key tool in efforts to mitigate climate change before 2050. However, the current nuclear technology, light water reactors (LWRs), is limited to 300°C, so it cannot be used to decarbonize industrial process heat which accounts for 12% of US greenhouse gas emissions. High temperature gas reactors (HTGRs) can meet the high temperature demand with carbon free nuclear heat. The estimated cost of HTGRs, such as the Next Generation Nuclear Plant (NGNP), are even higher than state-of-the-art LWRs. In this paper, we expanded our nuclear cost estimating tool to include HTGRs and find that the NGNP overnight capital costs were 32% higher than an advanced LWR per unit capacity. The higher cost will naturally result in larger risk to cost overrun as recently experienced by larger LWRs in western nations. With a design-to-build mindset to minimize cost and construction risk, we introduce the horizontal, compact HTGR (HC-HTGR). The reactor core and steam generator are mounted horizontally on rails and in-line with one another, decreasing the size of the reactor building relative to the power capacity four times when compared to traditional HTGRs. The HC-HTGR reduced overnight civil structure costs by 42%, indirect costs by 38%, and total capital costs by 20% from NGNP. We discussed the required engineering of new systems for the HC-HTGR including vessel supports, the reactor cavity cooling system, and steam generator design. Finally, we estimated the fuel and operations costs of the HC-HTGR, and a survey of low-carbon industrial process heat technology showed the HC-HTGR can deliver a highly competitive levelized cost of heat in the range of $6.13–12.48/GJ.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles is investigated using a novel transient three-dimensional computational fluid dynamics model. The model couples particle–gas hydrodynamics of solid–gas flows laden with polydisperse particles, radiative heat transfer in non-grey absorbing, emitting and anisotropically-scattering multi-component participating media, conduction heat transfer in the gas phase, and interfacial convection heat transfer. The multiphase particle-in-cell method is used to predict high-fidelity solid–gas flow characteristics, such as the local discrete particle size distribution, with increased computational efficiency by combining the advantages of both Eulerian and Lagrangian methods. The multi-component radiative transfer model is implemented using an advanced collision-based Monte Carlo ray-tracing method. The number of the prescribed discrete particle components is found to be the key parameter affecting the computational accuracy and efficiency, which primarily depends on the size distribution of the particles. For the model particle–gas flow featuring free-falling Gamma-distributed ceramic particles exposed to concentrated solar irradiation, the particle volume fraction, radiative, fluid flow and thermal characteristics appear to converge with the increasing number of the discrete particle components. Five particle components are sufficient to obtain physically meaningful results. A further increase in the number of the particle components only slightly increases the accuracy of the numerical predictions at the expense of a rapidly increasing computational time. For five particle components, the particle vertical velocity at the receiver exit for particles with the diameter of 43.4 μm is 57% of that for the particles with the diameter of 202.8 μm. The temperatures of these two particle components increase from the initial ambient values by factors of 2 and 1.2, respectively, during the simulation time. In conclusion, the model developed allows for increased fidelity of particle–gas flow simulations with significant radiative effects.

97 MATHEMATICS AND COMPUTING↗

Three influential factors on colloidal nanoparticle deposition for heat conduction enhancement in 3D chip stacks

Thermal management is one of the major challenges facing the development of three-dimensional (3D) chip stacks. Recently, experimental studies have shown that neck-based thermal structure (NTS) between chip layers formed by drying of colloidal suspension in cavity filled with micro-size particles can improve the vertical heat conduction threefold. However, a deep understanding of the mechanisms of neck formation and its influence on heat conduction is still lacking. In this paper, we numerically study the effects of three parameters, i.e., initial nanoparticle concentration, drying temperature and chip surface wettability on neck formation between filler particles and on the resulting heat conduction of the NTS. With increasing nanoparticle concentration, the size and number of necks increase, resulting in an increased effective thermal conductivity (ETC) of NTS. The drying temperature is found to have only little influence on the ETC of resultant NTS, while the neck size and spatial distribution become more uniform at higher drying temperature. When reducing the wettability of the top and bottom surfaces of the cavity, the necks shrink in size until completing evacuating at the top and bottom layers, while the size of the necks between filler particles in the middle height of the cavity expands slowly. In consequence, the ETC of NTS drops at an increasing rate. Being able to reveal the underlying multiple mechanisms of two-phase flow, phase change and heat transport, the current numerical study suggests optimal values for the deposition process, with initial nanoparticle concentration over 0.8%, a drying temperature of 60°C and a uniform contact angle of 30° for practical production of NTS.

3D chip stacks↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of pre-cooling as a recommended measure to improve residential buildings’ thermal resilience during heat waves

More intense heat waves are expected to occur more frequently in the twenty-first century. During severe heat waves, cooling capacity shortfall and overheating are likely to occur in residential buildings, and this will adversely affect occupant's thermal comfort and productivity. We propose a strategy of pre-cooling the house during off-peak hours to mitigate overheating during heat waves. Additionally, simulation results of a prototype single-family house show that adopting the rule-based control (RBC) of pre-cooling thermostat setpoint schedule is effective in reducing thermal discomfort, and that the efficacy of pre-cooling depends upon several building characteristics. An optimized control (OC) of the thermostat setpoint schedule was developed based on the simulation of a prototype building. A simplified yet improved RBC (IRBC) pre-cooling schedule was then extracted from the OC schedule for practical implementation at a larger scale. The effects of the RBC schedule and IRBC schedule were evaluated in the King District of Fresno, which contains 814 residential buildings. Results show that both thermostat setpoint schedules can reduce overheating effectively and that IRBC is slightly better than RBC for most buildings. The findings support the California government's recommendation on pre-cooling to mitigate overheating, which can be further improved with an optimized thermostat setpoint schedule broadcast to residents through early alert messages before a heat wave.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The role of building characteristics, demographics, and urban heat islands in shaping residential energy use

This study assesses the effects of residential building structure, socio-demographics, and ambient temperature conditions of a neighborhood to overall energy expenditures of a household. Using annual utility billing data, existing tax-lot records, temperature data, and U.S. Census demographic data, we ask two research questions: (1) What role do differences in neighborhood ambient heat, structural conditions and behavior play in helping to explain residential energy use? And (2) In what ways do energy expenditures spatially cluster in relation to urban heat islands? Using linear regression, spatial regression, and spatial clustering techniques, we evaluated the role of physical location of these households in relation to ambient temperatures. Significant positive relationships among energy expenditures and building size, average household size, White population, and population over 65 were observed; Significant negative relationships among energy expenditures and building density, renter population and population with a bachelor’s degree or higher were also observed. Negative relationships among morning and afternoon measures of heat, suggest that some areas spend less on energy use as a result of the neighborhood scale thermal environment. Spatial analysis of ambient temperature and energy expenditures show that energy use throughout the city is spatially clustered, with more affluent areas using more energy, regardless of whether heat islands are present. The results help to frame the role that increasing ambient temperatures in cities play in the spatial disparity in energy demand.

Residential Buildings, Energy Expenditure, Socio-d↗

Development of a silicon carbide ceramic based counter-flow heat exchanger by binder jetting and liquid silicon infiltration for concentrating solar power

A silicon carbide ceramic counter-flow heat exchanger with integrated headers was printed by binder jetting additive manufacturing process. Multiple phenolic binder infiltration cycles (3 or 5) followed by pyrolysis were conducted to increase the net carbon content of the printed SiC specimens. Subsequently, to attain full densification, silicon melt infiltration was used. The microstructure and mechanical properties were comprehensively characterized on the densified material. The chemical compositions and visual distribution of the various regions in the specimens were determined via scanning electron microscopy, while X-ray diffraction and synchrotron µ-computed tomography were used to provide a quantitative assessment of the volume fractions of the identified phase regions. Microhardness measurements showed dependence on the local microstructure. The fracture strength of the material was correlated with the specimen density and agreed with the reported values in the literature. High-temperature exposure at 750 °C for up to 200h did not degrade the strength for the specimens with three phenolic-binder infiltrations; however, the strengths degraded for ones with five phenolic-binder infiltrations. The associated fracture toughnesses of the specimens were ~3.4 MPam 1/2 at room temperature and 750°C, and the thermal conductivities varied from >150 W/mK at room temperature to ~45 W/mK at 750°C. Hence, this study validated the use of the binder-jetting printed SiC ceramic materials for high-temperature heat exchanges. Lastly, we also present in this work the first successful fabrication of a binder-jetting printed one-piece dense SiC ceramic heat exchanger body with unblocked channels that can be used for the flow of heat transfer fluids.

36 MATERIALS SCIENCE↗

Group additivity values for the heat of formation of C 2 –C 8 alkanes, alkyl hydroperoxides, and their radicals

A set of 58 group additivity values (GAV) for the calculation of the heat of formation is derived from an extensive and accurate database of 192 ab initio heats of formation. The ab initio values are from companion calculations at the CCSD(T)–F12/cc-pVTZ-F12//B2PLYPD3/cc-pVTZ level of theory employing second order connectivity based hierarchy reference reactions with ANL energies for the reference species. This database of 192 species consists of alkanes (RH), alkyl radicals ($\dot{\text {R}}$), alkyl hydroperoxides (RO 2 H), alkyl-peroxy (R$\dot{\text {O}}$ 2 ) radicals, and hydroperoxy-alkyl ($\dot{\text {Q}}$OOH) radicals of all of the isomers of C 2 –C 5 alkane fuels and a select set of C 6 –C 8 isomers. The GAV and ab initio based enthalpies for this dataset show excellent agreement, with an estimated 2σ uncertainty of 0.9 kcal mol –1 . Among the 58 GAV terms, 40 are refinements of previously reported terms, while 18 are newly developed. These new GAV terms are mainly non-next-nearest neighbor interactions (NNI) and β-corrections. The inclusion of these new groups significantly improves the accuracy of the GAV estimates of the heats of formation. Finally, the updated GAVs can be used with increased confidence to estimate the heats of formation of combustion relevant hydrocarbons and oxygenated hydrocarbons and their corresponding radicals, which are important in predicting low-temperature chemistry and are critical in the development of accurate chemical kinetic models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of radiation heat loss on planar and spherical hydrofluorocarbon/air flames

Hydrofluorocarbons (HFC), which are mildly flammable and pose potential fire risks, have received greater attention as a viable low global warming potential alternative to traditional refrigerant and fire-suppressant compounds. Therefore, there is a demand to accurately quantify their flammability and re-activity to establish proper safety metrics. Here, this study investigates the effects of radiation heat loss on slowly-propagating HFC/air laminar flames. Planar 1-D simulations of R-32/air and R-1234yf/air flames show significant reductions in laminar flame speed due to radiative heat losses from the flame zone. Simulations of spherically expanding flames (SEF) revealed that the radiation-induced flow needs to be considered when interpreting data from experiments. To this end, a Spherical-flame RADiation-Induced Flow (SRADIF) model was developed to estimate the burned gas inward flow velocities in constant-pressure SEFs, utilizing the optically thin limit assumption to model radiation heat loss. The model was validated against results from detailed numerical simulations of SEFs, from which radiation-induced inward flow was derived using a new formulation considering both the radiation heat loss and convective flow effects. Results show that SRADIF accurately predicts the inward flow velocity for R-32/air mixtures over a range of conditions and performs significantly better compared to existing analytical models. However, the model was unable to accurately predict flow velocities for R-1234yf/air flames and the reason for this is discussed. (224 words)

42 ENGINEERING↗

A Gaussian Process-Based extended Goldak heat source model for finite element simulation of laser powder bed fusion additive manufacturing process

In this study, laser powder bed fusion (L-PBF) additive manufacturing (AM) is a key enabling technology to manufacture highly complex and integrated metallic structures. In L-PBF AM process, the melting of the metal powders and the layers underneath can be governed by either “conduction mode” or “keyhole mode”, with the keyhole mode reportedly leading to porosity and decreased strength and ductility by many studies. In part scale simulations, finite element (FE) model is often used to study the temperature distribution during printing and to predict the residual stress, where a volumetric heat flux with a Gaussian or a double ellipsoidal (Goldak) distribution is often applied as the laser heat source. However, the above heat source models can only capture the melt pool shape in the conduction mode, and fail to capture the transition to keyhole melting mode when the process parameters change. To overcome this inaccuracy, an extended Goldak heat source model is proposed by introducing a laser penetration term as a function of laser parameters obtained from a Gaussian-Process (GP) model. The model is validated by “2D pad” AlSi10Mg L-PBF experiments under a wide range of laser power, scan speed, and laser focus offset, and the results show the model successfully captures the measured melt pool shape in all conditions.

36 MATERIALS SCIENCE↗

Development of physics-consistent conditional diffusion model to overcome data scarcity in critical heat flux

Deep generative modeling provides a powerful pathway to overcome data scarcity in energy-related applications where experimental data are often limited. By learning the underlying probability distribution of the training dataset, deep generative models, such as the diffusion model, can generate high-fidelity synthetic samples that statistically resemble the training data. Such synthetic data generation can significantly enrich the size and diversity of the available training data, and more importantly, improve the robustness of downstream machine learning models in predictive tasks. The objective of this paper is to investigate the effectiveness of diffusion models for overcoming data scarcity in nuclear energy applications. By leveraging a public dataset on critical heat flux which covers a wide range of commercial nuclear reactor operational conditions, we developed a diffusion model that can generate an arbitrary amount of synthetic samples. Since a vanilla diffusion model can only generate samples randomly, we also developed a conditional diffusion model capable of generating targeted critical heat flux data under user-specified thermal-hydraulic conditions. The performance of the diffusion model was evaluated based on its ability to capture empirical feature distributions and pair-wise correlations, as well as to maintain physical consistency. The results showed that both the diffusion model and conditional diffusion model can successfully generate realistic and physics-consistent critical heat flux data. Furthermore, uncertainty quantification results demonstrate that the conditional diffusion model is highly effective in augmenting critical heat flux data while maintaining acceptable levels of uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Improving energy efficiency while reducing anthropogenic heat from buildings: how retrofits influence the building stock and urban microclimate in Los Angeles

Anthropogenic heat (AH) from buildings contributes to urban overheating, especially during heat waves, yet building retrofit studies usually evaluate energy savings without assessing impacts on AH. This study quantifies how common building retrofit measures affect both building energy use and AH emissions across the City of Los Angeles. Using a bottom-up urban building energy modeling framework coupled with high-resolution local weather from the Weather Research and Forecasting model with Building Effect Parameterization (WRF-BEP), we evaluate eleven retrofit measures and two multi-measure retrofit packages. HVAC and LED lighting retrofits provide the largest city-wide annual site energy savings, while roof coating is most effective for reducing AH. A package optimized for energy savings reduces summer site energy use by about 32% (2.3 TWh), while a package incorporating AH-focused measures reduces the total AH by over 50% (137 PJ) with minimal difference in energy savings. The AH-aware package produces substantially greater urban cooling, reducing mean near-surface air temperature by up to 0.62 ℃ and peak temperature by up to 3.79 ℃. These results show that retrofit strategies selected only for energy savings may overlook major opportunities for urban heat mitigation. The study provides a framework for integrating AH into building retrofit planning and urban heat resilience policy.

Anthropogenic heat↗

Investigation of a thermocapacitive cycle by aqueous supercapacitors for multifunctional heat pump and energy storage

Thermocapacitive cycles are promising thermal and energy storage cycles using supercapacitors, which can achieve thermal efficiencies over 50% of the Carnot limit. There is a lack of work investigating the use of thermocapacitive effects in practical heat pumps. Here, this paper explores the design of thermocapacitive cells with higher temperature changes to be better suited for heat pumping applications. To evaluate the cell designs on temperature changes, pouch type cells are prototyped and modeled, and tested using a micro-calorimeter. A peak adiabatic temperature span of a LiCl aqueous cell is 2.7 °C. By arranging the cells in a cascade manner, the projected adiabatic temperature span can reach up to 12 °C with a heating density of 15 kW m −3 and an energy storage density of 0.83 kWh m −3 . Models predict that this could be increased to 30 °C and 1.65 kWh m −3 through improvements to cell capacitance and thermopower. Incorporating the energy storage capabilities into heating and cooling devices can be beneficial to building thermal management as energy storage becomes increasingly important for energy system integration.

25 ENERGY STORAGE↗

Multi-stage heat release of multi-component fuels: Insights and implications for advanced engine operation

Multi-stage heat release (MSHR) is a unique phenomenon typically seen in lean/diluted and low- to intermediate-temperature combustion. Despite its relevance to advanced engine operation, the MSHR of multi-component fuels has barely been quantified. This study aims to characterize the MSHR of multi-component fuels in a rapid compression machine (RCM) at conditions representative of advanced combustion engines. New experimental data are first reported in the RCM at an equivalence ratio of 0.4, pressure of 60 bar and temperatures from 702 to 795 K for a research grade, multi-component gasoline surrogate, termed PACE-20. Here, experiments confirm the existence of MSHR for PACE-20 at all temperatures, and reveal the strong inhibiting effect of temperature on MSHR, where increasing temperature inhibits MSHR by suppressing first stage heat release and promoting second and third stage heat release. A detailed chemical kinetic model is also adopted to model the experiments, with good agreement observed. The response of MSHR characteristics to changes in different engine operating parameters (i.e., temperature, pressure, equivalence ratio and CO 2 dilution level) and fuel compositions (i.e., mole fraction of n-pentane, n-heptane, isooctane, cyclopentane, 1-hexene, ethanol and aromatics in PACE-20) is further evaluated via statistical analysis coupling quasi-random sampling, extensive computer experiments and high-dimensional model representation. The change in MSHR is characterized through 8 quantities of interest (QOIs), i.e., duration and extent of each heat release stage, and their standard deviations. The analysis highlights the dependence of the QOIs on the individual parameters as well as their interplays, with temperature exhibiting the strongest impact among all parameters. Furthermore, it is demonstrated that if MSHR is to be facilitated and combustion phasing is to be extended to enable engine operation at higher compression ratios, it is recommended to operate the engine at low intake temperatures, boosted intake pressures and high CO 2 dilutions (i.e., high EGR levels) with gasoline fuels containing more n-pentane and less aromatics.

42 ENGINEERING↗