Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

BATSE Observations and Orbit Determination of the Be/X-Ray Transient EXO 2030+375

The Be/X-ray binary transient pulsar EXO 2030+375 (P(sub s) approx equal 42 s) has been observed with the large area detectors (LADs) of the Burst and Transient Source Experiment (BATSE) on the Compton Gamma-Ray Observatory (CGRO). Beginning in May 1991, twenty-two outbursts were observed over four years. Thirteen outbursts between February 1992 and August 1993 occurred consecutively at intervals of approx equal 46 days, close to the orbital period determined by Parmar et al. (1989) using EXOSAT data. The pulse profiles from the BATSE data are double-peaked and show no significant energy or luminosity dependence, unlike the EXOSAT observations of May-August 1985. An exponential model was used to fit the observed hard X-ray energy spectra from the thirteen consecutive outbursts. When EXOSAT discovered this pulsar during a giant outburst in May 1985, the X-ray luminosity peaked at L(sub x) = 1.0 x 10(esp 38) erg/ s (1-20 keV), assuming a 5 kpc distance to the source. The BATSE outbursts are found to be weaker 0.3 x 10(exp 37) less than or equal to L(sub x)(I-20 keV) less than or equal to 3.0 x 10(exp 37) erg/ s after extrapolating the observed flux (20-50 keV) to the EXOSAT energy band. Pulse phases derived from the thirteen outbursts were fit to two different models to determine a binary orbit. The new orbit is used to estimate 95% confidence limits for the mean peak spin frequency change during the out- bursts observed with BATSE. This, and the mean peak flux, are compared to the spin-up rates and fluxes determined by EXOSAT from the 1985 giant outburst, where disk accretion was thought to have occurred. It is unclear if these normal outbursts were driven by wind or disk accretion.

Strollberg, Mark T.↗

Exploring the Extreme Universe with GLAST

The Gamma-ray Large Area Space Telescope, GLAST, is a satellite-based experiment under development to measure the cosmic gamma-ray flux in the energy range 20 MeV to > 300 GeV. With a sensitivity that is more than a factor 30 greater than that of the EGRET detector on GRO, GLAST will open a new and important window on a wide variety of high energy phenomena, including supermassive black holes and active galactic nuclei, gamma-ray bursts, supernova remnants, and searches for new phenomena such as supersymmetric dark matter annihilations and big bang particle relics. The launch is planned for 2005. This talk will include a discussion of the physics, the scientific capabilities, the novel collaboration of particle physicists and high energy astrophysicists, and the mission status.

Ritz, Steven↗

The GLAST Burst Monitor

The GLAST Burst Monitor (GBM) comprises an array of NaI and BGO scintillation detectors designed to enhance the scientific return from GLAST in the study of gamma-ray bursts (GRBs). By observing in the 10 keV to 30 MeV energy range, GBM extends the spectral coverage of GRBs more than 3 decades below the LAT energy threshold. GBM computes burst locations on-board, allowing repointing of the GLAST Observatory to place strong bursts within the LAT field-of-view to observe delayed high-energy emission.

Meegan, Charles↗

Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

Radiation Simulation using Wi-Fi Signal Strength and Frequency

For routine radiological operations, lost radioactive sources, decommissioning and cleanup of nuclear facilities, and radiological terrorist events such as Radioactive Dispersive Devices (RDDs) or Radiological Exposure Devices (REDs), individuals are tasked with accurately locating both point and distributed sources of radiation. Radiation workers must often practice these tasks, whether part of initial training or periodically as part of formal or informal exercises or drills. In such circumstances, it is desirable to have an accurate recreation of a radioactive source, including a method of detecting it, which does not include dangerous amounts of radiation. The goal of this research was to develop a radiation simulation technology that uses IEEE 802.11x W-LAN protocol, i.e. Wi-Fi sources and detectors for these, as an inexpensive, precise and accurate method of replicating sources of gamma radiation. For this work, existing 802.11x sources were used. Software was developed for use with an Android smartphone to detect the presence of these sources. The measurements followed the expected behavior as a function of distance from the sources, mimicking that of gamma radiation, thus demonstrating the fundamental principle of operation. The ultimate system will be used in an outreach program to interest students in the radiation protection field.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of PIPS detectors for measurement of radioxenon

The International Monitoring System arm of the Comprehensive Nuclear-Test-Ban Treaty Organization utilizes sampling of atmospheric radioxenon to scan the world for nuclear testing events. Current designs utilized in the field involve plastic scintillator cells run in coincidence with Sodium Iodide (NaI) or High Purity Germanium (HPGe) detectors. The use of plastic scintillators as electron detectors exhibit some issues in comparison to other materials. Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution and lowered memory effect. A radioxenon detection setup was created with the intent of measuring radioxenon samples using coincidence counting between silicon and NaI detectors as well as silicon and HPGe. Finally, the absolute efficiency of both setups is calculated and compared.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

First Search for Neutral Current Coherent Single-Photon Production in MicroBooNE

This article presents the first search for neutrino-induced neutral current coherent single-photon production (NC coherent 1$\gamma$). The search makes use of data from the MicroBooNE 85-tonne active volume liquid argon time projection chamber detector, situated in the Fermilab Booster Neutrino Beam (BNB), with an average neutrino energy of $\langle E_{\nu}\rangle \sim 0.8$ GeV. A targeted selection of candidate neutrino interactions with a single photon-like electromagnetic shower in the final state and no visible vertex activity was developed to search for the NC coherent 1$\gamma$ process, along with two auxiliary selections used to constrain the dominant background from NC$\pi^0$ production. With an integrated exposure of $6.87 \times 10^{20}$ protons on target delivered by the BNB, we set the world's first limit for this rare process, corresponding to an upper limit on the flux-averaged cross section of $\sigma<1.49 \times 10^{-41}\text{cm}^2$ at 90% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the Advanced Energetic Pair Telescope (AdEPT) for Medium-Energy Gamma-Ray Astronomy

Progress in high-energy gamma-ray science has been dramatic since the launch of INTEGRAL, AGILE and FERMI. These instruments, however, are not optimized for observations in the medium-energy (approx.0.3< E(sub gamma)< approx.200 MeV) regime where many astrophysical objects exhibit unique, transitory behavior, such as spectral breaks, bursts, and flares. We outline some of the major science goals of a medium-energy mission. These science goals are best achieved with a combination of two telescopes, a Compton telescope and a pair telescope, optimized to provide significant improvements in angular resolution and sensitivity. In this paper we describe the design of the Advanced Energetic Pair Telescope (AdEPT) based on the Three-Dimensional Track Imager (3-DTI) detector. This technology achieves excellent, medium-energy sensitivity, angular resolution near the kinematic limit, and gamma-ray polarization sensitivity, by high resolution 3-D electron tracking. We describe the performance of a 30x30x30 cm3 prototype of the AdEPT instrument.

Hunter, Stanley D.↗

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scientific objectives of solar gamma-ray observations

Solar flare neutrons and gamma rays are produced by nuclear interactions of flare accelerated ions in the solar atmosphere. A rich variety of such gamma ray and neutron observations have been made by the Solar Maximum Mission (SSM), other satellite, balloon and ground based detectors, and they have provided a wealth of unique information on the nature of particle acceleration in flares and on the flare process itself. What we have learned from these observations is briefly reviewed, and what we can hope to learn from more sensitive new observations to be made with the Gamma Ray Observatory (GRO), the Max '91 balloon program, and the Nuclear Astrophysics Explorer is outlined.

Lingenfelter, R. E.↗

Performance Analysis and Radiation Damage Estimation of the Stopping Target Monitor Detectors in Mu2e

The Mu2e experiment aims to search for the charged lepton flavour violating (CLFV) process of a coherent, neutrinoless, conversion of a muon into an electron within the proximity of an aluminium nucleus. Mu2e seeks to measure the ratio (R μe ) of the rate of this conversion process, relative to that of ordinary muon capture. Mu2e will achieve world-leading sensitivity, improving the current limit of Rμe < 7 ×10 -13 (90% C.L.),set by the SINDRUM-II experiment, by an order of 104. This corresponds to a single-event sensitivity of Rμe < 2.87 × 10 -17 (90% C.L.). Many beyond Standard Model (BSM) theories require CLFV to occur at a rate accessible by Mu2e. Any observation of CLFV at Mu2e would have profound implications on particle physics. The Stopping Target Monitor (STM) will be comprised of both a HPGe and a LaBr3 detector which will monitor the signals of photons produced in stopped-muon processes to a required accuracy of 10%. To achieve the desired sensitivity, it is imperative that the detectors perform at their optimal level. The STM detectors are placed within a harsh radiation environment in the form of a high energy ‘flash’ of gamma radiation as well as a flux of fast neutrons. Estimations of radiation damage to HPGe in literature is limited. This thesis reports an approach which utilizes the Kinetic-Energy Released in Matter (KERMA) parameter that considers the energy dependence of the incident flux and the cross-section information for the incident particle. Resampling schemes have been adopted to give a realistic rate over the experiment run time. The results have then been normalized to the radiation damage caused by a 252 Cf source. The estimated time before annealing of the detector is necessary is found to be 75 and 78 months in the case of neutron damage and τ ~ 24 years, 11 months in the case of electron/positron induced damage. This shows significant improvement on the previous estimations.

36 MATERIALS SCIENCE↗

Some requirements of a colliding comet source of gamma ray bursts

Colliding comets in the Solar System may be an important source of gamma ray bursts. The spherical gamma ray comet cloud required by the results of the Venera Satellites (Mazets and Golenetskii, 1987) and the Burst and Transient Source Experiment (BATSE) detector on the Compton Satellite (Meegan et al., 1992a, b) is neither the Oort Cloud nor the Kuiper Belt. To satisfy observations of N(greater than P(sub max)) vs P(sub max) for the maximum gamma ray fluxes, P(sub max) greater than 10(exp -5) ergs/sq cm/ s (about 30 bursts/yr), the comet density, n, should increase as n approximately a(exp 1) from about 40 to 100 AU where a is the comet heliocentric distance. The turnover above 100 AU requires n approximately a(exp -1/2) to 200 AU to fit the Venera results and n approximately a(exp 1/4) to 400 AU to fit the BATSE data. Then the masses of comets in the 3 regions are from: 40-100 AU, about 9 earth masses, m(sub E); 100-200 AU about 25 m(sub E); and 100-400 AU, about 900 m(sub E). The flux of 10(exp -5) ergs/sq cm/s corresponds to a luminosity at 100 AU of 3 x 10(exp 26) ergs/s. Two colliding spherical comets at a distance of 100 AU, each with nucleus of radius R of 5 km, density of 0.5 g/cu cm and Keplerian velocity 3 km/s have a combined kinetic energy of 3 x 10(exp 28) erg, a factor of about 100 greater tha required by the burst maximum fluxes that last for one second.

White, R. Stephen↗

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2022 Report

In the first two quarters of FY22, data acquisition continued at ORNL and LLNL using uranium sources of known enrichments. This was an FY21 task which could not be completed in FY21 because of problems encountered with the ORNL M400 CZT in Q4 of FY21, and the subsequent repairs. The detector was received back from H3D in the first of September 2021 , and the measurements resumed . Measurements using the repaired detector were completed in Q1 of FY22. The spectra were distributed by ORNL to the analyzing labs. Analysis results were received in Q2 of FY2022. The results from the various codes were intercompared and an ANOVA analysis was performed. Random and systematic uncertainties were established for each code. The ANOVA results and discussions were included in a revised version of FY21Annual Report issued in March 2022. A paper was presented at the INMM 2022Annual Conference, with the analysis results from the various isotopic codes, and the ANOVA table with random and systematic uncertainties. The Project Work Plan (PWP) for FY22 included a task to perform field testing of the M400 CZT and the analysis codes using UF 6 cylinder measurements at the Framatome Fuel Fabrication Facility in Richland, WA. PNNL was the lead for the field testing task. PNNL drafted a Field Test Plan, and refined it based on comments received from the team. PNNL coordinated with Framatome facility, the logistics of carrying out the field testing . A collimator and shield made out of TFlex (tungsten impregnated polymer) was designed and professionally manufactured. The collimators were used in the field test measurements. The measurements at Framatome were completed on April 21, 2022. A total of 34 Type 30B cylinders were measured using three M400 detectors (PNNL, LLNL, and ORNL detectors). Measurements using M400 were taken at two locations on the side of each cylinder and from the end-on bottom location. Additionally, HPGe measurements were taken at the end-on location to establish ground truth. Cylinder wall thickness measurements were also made at all three locations. To gain a better understanding of the effect of background from surrounding cylinders, the same five cylinders measured individually in low background locations were measured again in the cylinder storage yards. Due to inclement weather, manufacturer delays, shipping delays, and equipment failure, the measurement campaign spanned twice as long compared to the original timeline. Gamma-ray spectra from M400 and HPGe detectors, along with the cylinder data and photographs were organized and shared with the collaborators for further analysis. Spectra were analyzed by the participating laboratories. FY22 PWP also consists of tasks related to plutonium source measurements, adapting the codes to analyze plutonium spectra, and inter-comparison of the results from various codes. Plutonium spectra are being acquired at LANL, ORNL, and LLNL. LANL, SNL and LLNL are in the process of modifying FRAM, GADRAS, and CZTU, respectively. The plutonium related tasks will be completed in Q2 of FY23.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an ultra-fast BaF₂-based detector

BaF₂ is one of the fastest known scintillators, emitting at 220 nm with sub-nanosecond decay constant; Excellent for timing applications. 4.88 g/cm³ → High detection efficiency; At 15 cm thick, nearly 100% efficient for gammas up to 10 MeV. Problem: ~80% of the total light output consists of slower (600 ns decay constant) emission peaked at 310 nm; High count rate → pile up. Goal: develop a BaF₂-based detector that leverages the fast emission component for optimal timing characteristics; Suppression of slow component.

47 OTHER INSTRUMENTATION↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗

The Moon Burst Energetics All-sky Monitor (MoonBEAM)

MoonBEAM is a SmallSat concept placed in cislunar orbit developed to study the progenitors and multimessenger/multiwavelength signals of transient relativistic jets and outflows and determine the conditions that lead to the launching of a transient relativistic jet. The distinguishing advantage of MoonBEAM is the instantaneous all-sky coverage, maximizing the gamma-ray transients observations and providing upper limits for nondetections. Gamma-ray observatories in low Earth orbit are not able to survey the entire sky at a given time due to Earth blockage as well as detector downtime from the high particle activity in the South Atlantic Anomaly region. The long baseline provided from a cislunar orbit, allows MoonBEAM to constrain the localization annulus when combined with a gamma-ray instrument in low Earth orbit utilizing the timing triangulation technique. Improving the localization precision of a gamma-ray burst aids the gravitational wave follow-up community in reducing the region needed to be searched to locate and identify the afterglow and kilanova emission. Furthermore, by providing a different vantage point for a gamma-ray detection, MoonBEAM can help extend the gravitational wave detection horizon by increasing the confidence of a simultaneous marginal gravitational wave signal. Through the all-sky coverage, MoonBEAM will also provide insight into the conditions that lead to a successful relativistic jet, instead of a shock breakout event, or a completely failed jet in the case of core collapse supernovae.

Gamma-ray Bursts↗

Anti-Coincidence Detector for GLAST

The Anti-Coincidence Detector (ACD) is the outermost detector layer in the GLAST Large Area Telescope (LAT), surrounding the top and sides of the tracker. The purpose of the ACD is to detect and veto incident cosmic ray charged particles, which outnumber cosmic gamma rays by 3-5 orders of magnitude. The challenge in ACD design is that it has to have high (0.9997) detection efficiency for relativistic charged particles, but must have low sensitivity to backsplash photons. These are products of high energy interactions in the LAT calorimeter, and can cause a veto signal in the ACD resulting in degradation of the LAT efficiency for high energy (>10 GeV) gamma-rays. The ACD requirement is that backsplash shall not reduce the LAT sensitivity by more than 20% for gamma rays of 300 GeV. To solve this problem, the ACD is divided into 89 scintillating tiles, with wave-length shifting fiber readout. The detector design and its characteristics are given in this paper.

Moiseev, Alexander A.↗

Monitoring of inventory in enclosed turbulent liquid tanks using floating gamma-ray sources

An accurate and simple technique utilizing a low-intensity gamma-ray source floating in a vertical tube, whose configuration is tank geometry and size dependent, is shown to eliminate the disturbing effects of turbulent fluid on enclosed tank liquid inventory measurement. The vertical tube aligns the source with detectors positioned outside of the tank, and collapses the turbulent liquid surface to a true average level. The exit attenuation of the information carrying high energy gamma rays is insensitive to liquid surface tubulence, and sensing probe penetrations are not necessary. It is found that for a half-full tank, 1.0 percent statistical error, and 1-s measuring times, that a 220 C Ce-137 source is required for an 8-ft high tank. Consistent experimental results are found for the dual detector method, and results indicate that the accuracy of the scanning side detector method is dependent on the quality of the collimator and degree of lower level energy discrimination.

Klein, R. M.↗