At least 1,117 records · Page 62

Laboratory molecular spectroscopy

The precision required in making spectroscopic measurements is discussed. Remarks are directed specifically to vibration-rotation spectra rather than continuum absorptions. The ultimate precision that is required for line positions is related to the width of the lines which may be no narrower than the Doppler width. The spectroscopic methods considered are those which are of the most general value to the astronomers; those which acquire and can handle large volumes of spectra in digital form, or in a form which is compatible with computer analysis, and in a form which is at least internally consistent. The use of dye laser, grating instruments, and the most versatile instrument for laboratory spectroscopy, the Fourier transform spectrometer is discussed.

Margolis, J.↗

Atmospheric infrared emission of ClONO2 observed by a balloon-borne Fourier spectrometer

ClONO2 was observed in high-resolution infrared emission spectra obtained on Nov. 6, 1984, by a balloon-borne Fourier spectrometer. The observations took place near 0300 LT at a latitude of 35 N. Spectral simulations are used to determine the mixing ratios of ClONO2. This analysis incorporates line by line calculations and new ClONO2 cross sections measured in the laboratory at 223 K. The inferred mixing ratios of ClONO2 are 1.3 + or - 0.45 ppb and 0.98 + or - 0.35 ppb at 14 and 34 mbar. One-dimensional photochemical model predictions are compared to the observations. The ClONO2 mixing ratio at 34 mbar appears to be larger than theory, while there is agreement at 14 mbar.

Massie, S. T.↗

Maynooth Optical Aeronomical Facility

Ground-based measurements of upper atmospheric parameters, such as temperature and wind velocity, can be made by observing airglow emissions that have a well-defined altitude profile and that are known to be representative of the emitting region. We describe the optical observatory at Maynooth (53.23 deg N, 6.4 deg W) at which two instruments, a Fabry-Perot interferometer and a Fourier transform spectrometer, are used to record atmospheric airglow emissions in Ireland at visible and near-infrared wavelengths, respectively. Descriptions of the instruments, data acquisition, and analysis procedures are provided, together with some sample results.

Mulligan, Francis J.↗

Capture and Decomposition of the Nerve Agent Simulant, DMCP, Using the Zeolitic Imidazolate Framework (ZIF-8)

Understanding mechanisms of decontamination of chemical warfare agents (CWA) is an area of intense research aimed at developing new filtration materials to protect soldiers and civilians in case of state-sponsored or terrorist attack. In this study, we employed complementary structural, chemical, and dynamic probes and in situ data collection, to elucidate the complex chemistry, capture, and decomposition of the CWA simulant, dimethyl chlorophosphonate (DMCP). Our work reveals key details of the reactive adsorption of DMCP and demonstrates the versatility of zeolitic imidazolate framework (ZIF-8) as a plausible material for CWA capture and decomposition. Here, the in situ synchrotron-based powder X-ray diffraction (PXRD) and pair distribution function (PDF) studies, combined with Fourier transform infrared (FT-IR) spectroscopy, X-ray photoelectron spectroscopy (XPS), zinc K-edge X-ray absorption near edge structure (XANES), and Raman spectroscopies, showed that the unique structure, chemical state, and topology of ZIF-8 enable accessibility, adsorption, and hydrolysis of DMCP into the pores and revealed the importance of linker chemistry and Zn 2+ sites for nerve agent decomposition. DMCP decontamination and decomposition product(s) formation were observed by thermogravimetric analysis, FT-IR spectroscopy, and phosphorus (P) K-edge XANES studies. Differential PDF analysis indicated that the average structure of ZIF-8 (at the 30 Å scale) remains unchanged after DMCP dosing and provided information on the dynamics of interactions of DMCP with the ZIF-8 framework. Using in situ PXRD and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), we showed that nearly 90% regeneration of the ZIF-8 structure and complete liberation of DMCP and decomposition products occur upon heating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Kariya ( Hildegardia barteri (Mast.) Kosterm) Seed Oil Fatty Acid Methyl Ester Prepared from Basic Catalytic Transesterification

The rising global energy demand, alongside concerns regarding environmental deterioration due to the use of fossil fuels, has spurred extensive investigation into renewable energy alternatives. Biomass-derived biodiesel, especially from lesser-known oil sources, emerges as a promising option. This research focuses on analyzing the fatty acid methyl esters (FAMEs) derived from Kariya (Hildegardia barteri (Mast.) Kosterm) seed oil through basic catalytic transesterification using gas chromatography–flame ionization detector (GC–FID) analysis, assessing its potential as a biodiesel feedstock. Oil extraction from Kariya seeds was carried out using three solvents (n-hexane, ethanol, and a 1:1 blend of hexane and ethanol), followed by transesterification with methanol. Gas chromatography–mass spectrometry (GC–MS) and GC–FID analyses were utilized to identify and quantify FAMEs in the resulting biodiesel. The results revealed various FAMEs, including methyl myristate, methyl palmitate, methyl stearate, methyl oleate, methyl linoleate, and methyl linolenate. Significant differences in FAME composition were observed among the samples, with hexane–ethanol Kariya oil biodiesel (HE-KOB) showing the highest FAME content (76.1%). This combination of solvents exhibited synergistic effects on the composition of HE-KOB, suggesting potential optimization strategies for biodiesel production. Fourier transform infrared spectroscopy (FTIR) provided additional insights into the molecular composition of the biodiesel samples, confirming their biodiesel nature through the identified functional groups such as methyl, methylene, hydrocarbon, ester, aldehyde, and alkene. Thermogravimetric analysis (TGA) for thermal decomposition also gave an insight into FAME composition and its contribution to the degree of conversion of biodiesel to energy. These findings highlight the feasibility of utilizing Kariya seed oil as a biodiesel feedstock, emphasizing the importance of solvent selection and transesterification conditions in optimizing FAME yield and composition. This research contributes to the exploration of underutilized oil sources for sustainable biodiesel production, aligning with the global shift towards cleaner and renewable energy sources.

09 BIOMASS FUELS↗

Evaluation of the use of a singularity element in finite element analysis of center-cracked plates

Two different methods are applied to the analyses of finite width linear elastic plates with central cracks. Both methods give displacements as a primary part of the solution. One method makes use of Fourier transforms. The second method employs a coarse mesh of triangular second-order finite elements in conjunction with a single singularity element subjected to appropriate additional constraints. The displacements obtained by these two methods are in very good agreement. The results suggest considerable potential for the use of a cracked element for related crack problems, particularly in connection with the extension to nonlinear material behavior.

Mendelson, A.↗

Shaped reflector antenna analysis using the Jacobi-Bessel series

A vector radiation integral is derived for an offset shaped reflector illuminated by an arbitrarily located and oriented source. A procedure for expressing the integral in terms of a series of the Fourier transforms of an effective aperture distribution is discussed. The Jacobi-Bessel series is used to evaluate the Fourier transforms. Numerical results are presented for different reflector configurations and source locations.

Rahmat-Samii, Y.↗

Spectral analysis of wave motion in plane solids with boundaries

A spectral formulation is employed whereby in-plane stress waves are synthesized from the superposition of components at discrete frequencies and wavenumbers. The summations are performed using the fast Fourier transform and the Fourier series, respectively. Because the components are discrete, the solution to problems (over the entire field) with completely arbitrary loading, both in time and space, is made tractable. Waves generated from a line load acting on an infinite and semiinfinite plane are first considered. A cascade approach is then adopted for the treatment of these waves incident on a free, fixed, and elastic boundary. At each stage, the results are compared with those obtained from the available classical solutions and/or finite element results. These studies will form the basis for the investigation of in-plane stress waves in multiply layered media.

Rizzi, S. A.↗

Translation and rotation equivariant normalizing flow (TRENF) for optimal cosmological analysis

ABSTRACT Our Universe is homogeneous and isotropic, and its perturbations obey translation and rotation symmetry. In this work, we develop translation and rotation equivariant normalizing flow (TRENF), a generative normalizing flow (NF) model which explicitly incorporates these symmetries, defining the data likelihood via a sequence of Fourier space-based convolutions and pixel-wise non-linear transforms. TRENF gives direct access to the high dimensional data likelihood p(x|y) as a function of the labels y, such as cosmological parameters. In contrast to traditional analyses based on summary statistics, the NF approach has no loss of information since it preserves the full dimensionality of the data. On Gaussian random fields, the TRENF likelihood agrees well with the analytical expression and saturates the Fisher information content in the labels y. On non-linear cosmological overdensity fields from N-body simulations, TRENF leads to significant improvements in constraining power over the standard power spectrum summary statistic. TRENF is also a generative model of the data, and we show that TRENF samples agree well with the N-body simulations it trained on, and that the inverse mapping of the data agrees well with a Gaussian white noise both visually and on various summary statistics: when this is perfectly achieved the resulting p(x|y) likelihood analysis becomes optimal. Finally, we develop a generalization of this model that can handle effects that break the symmetry of the data, such as the survey mask, which enables likelihood analysis on data without periodic boundaries.

79 ASTRONOMY AND ASTROPHYSICS↗

HRMA calibration handbook: EKC gravity compensated XRCF models

This document, consisting of hardcopy printout of explanatory text, figures, and tables, represents one incarnation of the AXAF high resolution mirror assembly (HRMA) Calibration Handbook. However, as we have envisioned it, the handbook also consists of electronic versions of this hardcopy printout (in the form of postscript files), the individual scripts which produced the various figures and the associated input data, the model raytrace files, and all scripts, parameter files, and input data necessary to generate the raytraces. These data are all available electronically as either ASCII or FITS files. The handbook is intended to be a living document and will be updated as new information and/or fabrication data on the HRMA are obtained, or when the need for additional results are indicated. The SAO Mission Support Team (MST) is developing a high fidelity HRMA model, consisting of analytical and numerical calculations, computer software, and databases of fundamental physical constants, laboratory measurements, configuration data, finite element models, AXAF assembly data, and so on. This model serves as the basis for the simulations presented in the handbook. The 'core' of the model is the raytrace package OSAC, which we have substantially modified and now refer to as SAOsac. One major structural modification to the software has been to utilize the UNIX binary pipe data transport mechanism for passing rays between program modules. This change has made it possible to simulate rays which are distributed randomly over the entrance aperture of the telescope. It has also resulted in a highly efficient system for tracing large numbers of rays. In one application to date (the analysis of VETA-I ring focus data) we have employed 2 x 10(exp 7) rays, a substantial improvement over the limit of 1 x 10(exp 4) rays in the original OSAC module. A second major modification is the manner in which SAOsac incorporates low spatial frequency surface errors into the geometric raytrace. The original OSAC included the ability to use Legendre-Fourier polynomials to describe deviations from the basic optical prescription. To this we have added bicubic splines to address a deficiency in the handling of the sharper deformations in the areas of mirror support pads. SAO has developed software (TRANS-FIT) to translate the most common finite element analysis models into these forms for incorporation into the raytrace program.

Tananbaum, H. D.↗

Investigating the impacts of solid phase extraction on dissolved organic matter optical signatures and the pairing with high‐resolution mass spectrometry data across a freshwater stream network

Abstract Advancing our understanding of dissolved organic matter (DOM) chemistry in aquatic systems necessitates the integration of data streams from multiple analytical platforms. Some measurements require pretreatment with solid phase extraction (SPE), while others are performed directly on whole water samples. Evidence has suggested that SPE will be biased against select DOM fractions, leading to concerns over the ability to establish data linkages across platforms with variable needs for SPE pretreatment, such as those from optical measurements and those that provide high‐resolution molecular information. Here, we directly addressed this concern by assessing the impact of SPE on DOM optical properties through excitation–emission matrices with parallel factor analysis (PARAFAC) for 47 samples across a stream network within a single watershed reflective of variable DOM sources. PARAFAC data was further paired with molecular information obtained by Fourier transform ion cyclotron resonance mass spectrometry (FTICR‐MS). A comparison of PARAFAC models first revealed no systematic qualitative differences in major components between whole water DOM and DOM isolated by SPE (SPE‐DOM); however, quantitative biases against select components were observed. Further linkages with FTICR‐MS data revealed that the molecular fingerprint associated with each PARAFAC component was consistent between the whole water DOM and SPE‐DOM. Our results suggest that bulk scale linkages across these analytical platforms could be inferred irrespective of the observed quantitative biases resulting from SPE for samples within this example watershed. This work represents a key step toward the systematic evaluation of linkages between optical and high‐resolution mass spectrometry datasets in freshwater lotic environments.

59 BASIC BIOLOGICAL SCIENCES↗

Multimodal imaging of hemorrhagic transformation biomarkers in an ischemic stroke model.

Abstract Hemorrhagic transformation of ischemic stroke has devastating consequences, with high mortality and poor functional outcomes. Animal models of ischemic stroke also demonstrate the potential for hemorrhagic transformation, which complicates biochemical characterization, treatment studies, and hinders poststroke functional outcomes in affected subjects. The incidence of hemorrhagic transformation of ischemic stroke in animal model research is not commonly reported. The postmortem brain of such cases presents a complex milieu of biomarkers due to the presence of healthy cells, regions of varying degrees of ischemia, dead and dying cells, dysregulated metabolites, and blood components (especially reactive Fe species released from lysed erythrocytes). To improve the characterization of hemorrhage biomarkers on an ischemic stroke background, we have employed a combination of histology, X-ray fluorescence imaging (XFI), and Fourier transform infrared (FTIR) spectroscopic imaging to assess 122 photothrombotic (ischemic) stroke brains. Rapid freezing preserves brain biomarkers in situ and minimizes metabolic artifacts due to postmortem ischemia. Analysis revealed that 25% of the photothrombotic models had clear signs of hemorrhagic transformation. The XFI and FTIR metabolites provided a quantitative method to differentiate key metabolic regions in these models. Across all hemorrhage cases, it was possible to consistently differentiate otherwise healthy tissue from other metabolically distinct regions, including the ischemic infarct, the ischemic penumbra, blood vessels, sites of hemorrhage, and a region surrounding the hemorrhage core that contained elevated lipid oxidation. Chemical speciation of deposited Fe demonstrates the presence of heme-Fe and accumulation of ferritin.

Pushie, M. J. (ORCID:0000000174945427)↗

Frequency and intensity analysis of the nu3, nu4, and nu6 bands of formaldehyde

The infrared spectra of the nu3, nu4, and nu6 bands of formaldehyde in the region from 890/cm to 1580/cm have been obtained at high resolution using tunable diode laser and Fourier transform-infrared spectroscopy. The transition frequencies have been analyzed using a Hamiltonian including terms through sextic in centrifugal distortion and including five interstate vibration-rotation coupling terms. Excited-state pure rotational transitions are also included in the data, and their frequencies are reproduced well. Individual measured line intensities are used to determine dipole derivatives and band strengths using the fully coupled, asymmetric top eigenvectors.

Reuter, D. C.↗

Water in the deep atmosphere of Venus from high-resolution spectra of the night side

High-resolution, near-infrared (1.09 to 2.5 micrometers) spectra of the night side of Venus have been obtained in 1990 and 1991 using the Fourier Transform Spectrometer at the 3.6-m Canada-France-Hawaii telescope. Absorptions due to H2O were detected in spectral windows near 2.3, 1.74, and 1.18 micrometers. Our analysis of these absorptions constrains the abundance of water vapor in three different altitude ranges located between the clouds and the surface: 30-40 km, 15-25 km and 0-15 km. A constant water vapor mixing ratio of 30 +/- 15 ppm below the clouds can fit the observations. These values are consistent with recent near-infrared studies of the night side of Venus at lower spectral resolution. The atmosphere of Venus appears to be dryer than originally suggested by the in-situ measurements made by the Pioneer Venus and Venera mass-spectrometers and gas-chromatographs.

De Bergh, C.↗

Analytical Tools for Cloudscope Ice Measurement

The cloudscope is a ground or aircraft instrument for viewing ice crystals impacted on a sapphire window. It is essentially a simple optical microscope with an attached compact CCD video camera whose output is recorded on a Hi-8 mm video cassette recorder equipped with digital time and date recording capability. In aircraft operation the window is at a stagnation point of the flow so adiabatic compression heats the window to sublimate the ice crystals so that later impacting crystals can be imaged as well. A film heater is used for ground based operation to provide sublimation, and it can also be used to provide extra heat for aircraft operation. The compact video camera can be focused manually by the operator, and a beam splitter - miniature bulb combination provide illumination for night operation. Several shutter speeds are available to accommodate daytime illumination conditions by direct sunlight. The video images can be directly used to qualitatively assess the crystal content of cirrus clouds and contrails. Quantitative size spectra are obtained with the tools described in this report. Selected portions of the video images are digitized using a PCI bus frame grabber to form a short movie segment or stack using NIH (National Institute of Health) Image software with custom macros developed at DRI. The stack can be Fourier transform filtered with custom, easy to design filters to reduce most objectionable video artifacts. Particle quantification of each slice of the stack is performed using digital image analysis. Data recorded for each particle include particle number and centroid, frame number in the stack, particle area, perimeter, equivalent ellipse maximum and minimum radii, ellipse angle, and pixel number. Each valid particle in the stack is stamped with a unique number. This output can be used to obtain a semiquantitative appreciation of the crystal content. The particle information becomes the raw input for a subsequent program (FORTRAN) that synthesizes each slice and separates the new from the sublimating particles. The new particle information is used to generate quantitative particle concentration, area, and mass size spectra along with total concentration, solar extinction coefficient, and ice water content. This program directly creates output in html format for viewing with a web browser.

Arnott, W. Patrick↗

The Fundamental Quadrupole Band of (14)N2: Line Positions from High-Resolution Stratospheric Solar Absorption Spectra

The purpose of this note is to report accurate measurements of the positions of O- and S-branch lines of the (1-0) vibration-rotation quadrupole band of molecular nitrogen ((14)N2) and improved Dunham coefficients derived from a simultaneous least-squares analysis of these measurements and selected infrared and far infrared data taken from the literature. The new measurements have been derived from stratospheric solar occultation spectra recorded with Fourier transform spectrometer (FTS) instruments operated at unapodized spectral resolutions of 0.002 and 0.01 /cm. The motivation for the present investigation is the need for improved N2 line parameters for use in IR atmospheric remote sensing investigations. The S branch of the N2 (1-0) quadrupole band is ideal for calibrating the line-of-sight airmasses of atmospheric spectra since the strongest lines are well placed in an atmospheric window, their absorption is relatively insensitive to temperature and is moderately strong (typical line center depths of 10 to 50% in high-resolution ground-based solar spectra and in lower stratospheric solar occultation spectra), and the volume mixing ratio of nitrogen is constant in the atmosphere and well known. However, a recent investigation has'shown the need to improve the accuracies of the N2 fine positions, intensities, air-broadened half-widths, and their temperature dependences to fully exploit this calibration capability (1). The present investigation addresses the problem of improving the accuracy of the N2 line positions.

Rinsland, C. P.↗

A Gravity-Responsive Time-Keeping Protein of the Plant and Animal Cell Surface

The hypothesis under investigation was that a ubiquinol (NADH) oxidase protein of the cell surface with protein disulfide-thiol interchange activity (= NOX protein) is a plant and animal time-keeping ultradian (period of less than 24 h) driver of both cell enlargement and the biological clock that responds to gravity. Despite considerable work in a large number of laboratories spanning several decades, this is, to my knowledge, our work is the first demonstration of a time-keeping biochemical reaction that is both gravity-responsive and growth-related and that has been shown to determine circadian periodicity. As such, the NOX protein may represent both the long-sought biological gravity receptor and the core oscillator of the cellular biological clock. Completed studies have resulted in 12 publications and two issued NASA-owned patents of the clock activity. The gravity response and autoentrainment were characterized in cultured mammalian cells and in two plant systems together with entrainment by light and small molecules (melatonin). The molecular basis of the oscillatory behavior was investigated using spectroscopic methods (Fourier transform infrared and circular dichroism) and high resolution electron microscopy. We have also applied these findings to an understanding of the response to hypergravity. Statistical methods for analysis of time series phenomena were developed (Foster et al., 2003).

Morre, D. James↗

Teflon FEP Analyzed After Retrieval From the Hubble Space Telescope

During the Hubble Space Telescope (HST) Second Servicing Mission, 6.8 years after the telescope was deployed in low Earth orbit, degradation of unsupported Teflon FEP (DuPont; fluorinated ethylene propylene), used as the outer layer of the multilayer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer (see the photograph) was retrieved during the second servicing mission and returned to Earth for ground testing and evaluation. Also retrieved was a Teflon FEP radiator surface from a cryogen vent cover that was exposed to the space environment on the aft bulkhead of the HST. NASA Goddard Space Flight Center directed the efforts of the Hubble Space Telescope MLI Failure Review Board, whose goals included determining the FEP degradation mechanisms. As part of the investigations into the degradation mechanisms, specimens retrieved from the first and second HST servicing missions, 3.6 and 6.8 years after launch, respectively, were characterized through exhaustive mechanical, optical, and chemical testing. Testing led by Goddard included scanning electron microscopy, optical microscopy, tensile testing, solar absorptance measurements, time-of-flight secondary ion mass spectroscopy (TOF-SIMS), Fourier transform infrared microscopy (m-FTIR), attenuated total reflectance infrared microscopy (ATR/FTIR), and x-ray diffraction (XRD). The NASA Lewis Research Center contributed significantly to the analysis of the retrieved HST materials by leading efforts and providing results of bend testing, surface microhardness measurements, x-ray photoelectron spectroscopy, solid-state nuclear magnetic resonance spectroscopy, and density measurements. Other testing was conducted by Nano Instruments, Inc., and the University of Akron.

Dever, Joyce A.↗