Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy storage data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Inverted Region in Bimolecular Electron Transfer in Solution Enabled by Delocalization

Rate constants for bimolecular electron transfer (ET) increased with driving force, -ΔG°, reached a plateau, and then decreased in an inverted region. This rate data was described well by electron transfer theory subject to a diffusion-controlled limit. These were for ET from radical anions of polydecylthiophene (P3DT) to a series of acceptors in THF solution. When the donor was the smaller anion of quaterthiophene (T4 •- ) the inverted region was much less prominent, and still less so for when the donor was the anion of bithiophene (T2 •- ). Description of the data using ET theory identifies smaller electronic couplings for the highly-delocalized P3DT anions as enabling the inverted behavior: The presence of a Marcus inverted region is a consequence of delocalized electronic states. The results of this study further imply that electronic couplings smaller than usually found for molecules in contact could boost efficiency of energy storage by electron transfer, and identifies size-mismatch as an important concept in control of electronic couplings.

14 SOLAR ENERGY↗

OVERVIEW OF PARTICLE DEPOSITION MODELS FOR SPENT NUCLEAR FUEL STORAGE SYSTEMS

Deposition models were built to evaluate contaminant deposition on spent nuclear fuel (SNF) canisters. The primary contaminant of concern is chloride, which is dispersed in the atmosphere and then deposits onto the canisters. During dry storage, the primary degradation process is likely to be Chloride Induced Stress Corrosion Cracking (CISCC) at the heat-affected zones of the canister welds. It is known that stainless steel canisters are susceptible to CISCC; however, the rate of chloride deposition onto the canisters is poorly known, based on sparse field data from a small number of sites. The models presented in this study could be useful for determining the rate of deposition on the canisters and the likelihood of CISCC to help with SNF canister ageing management. The deposition models were developed with the commercial computational fluid dynamics (CFD) code STAR-CCM+. Various deposition mechanisms were considered and incorporated into the models, and a sensitivity study was conducted to determine the most important mechanisms for deposition within a SNF storage system. The models included both a vertical and horizontal configuration storage system: NAC International’s Modular, Advanced Generation, Nuclear All-purpose STORage System (MAGNASTOR®) and a NUHOMS® horizontal storage module respectively. The resulting canister deposition on the horizontal canister is visually compared with inspection data taken onsite at the Calvert Cliffs Nuclear Power Plant. These models are preliminary, and development of the models will continue. Future validation exercises are currently being planned, including the Canister Deposition Field Demonstration (CDFD) effort funded by U.S. Department of Energy office of Nuclear Energy office of Spent Fuel Waste Science and Technology. The goal of the modeling presented is to demonstrate a potential modeling technique that could be used to plan and inform SNF canister ageing management programs with predictive models for the timing and occurrence of canister CISCC.

Suffield, Sarah R.↗

CO 2 Storage prospeCtive Resource Estimation Excel aNalysis (CO 2 -SCREEN) User’s Manual: Python_V4.1

This user’s manual guides the use of the National Energy Technology Laboratory’s (NETL) CO 2 Storage prospeCtive Resource Estimation Excel aNalysis (CO 2 -SCREEN) tool, which was developed to aid users in screening geologic formations for prospective CO 2 storage resources. This manual is specific to the CO 2 -SCREEN 4.1 version which is based in Python. The 4.1 version of CO 2 -SCREEN adds in newly updated storage efficiency factors for saline formations. CO 2 -SCREEN applies U.S. Department of Energy (DOE) methods and equations for estimating prospective CO 2 storage resources for saline formations, shale formations, and residual oil zones (ROZ). CO 2 -SCREEN was developed to be substantive and user-friendly and provide a consistent method for calculating prospective CO 2 storage resources. CO 2 -SCREEN uses a Java- based graphical user interface (GUI) for data inputs and uses Python to calculate prospective CO 2 storage resources.

54 ENVIRONMENTAL SCIENCES↗

A computerized aircraft battery servicing facility

The latest upgrade to the Aerospace Energy Systems Laboratory (AESL) is described. The AESL is a distributed digital system consisting of a central system and battery servicing stations connected by a high-speed serial data bus. The entire system is located in two adjoining rooms; the bus length is approximately 100 ft. Each battery station contains a digital processor, data acquisition, floppy diskette data storage, and operator interfaces. The operator initiates a servicing task and thereafter the battery station monitors the progress of the task and terminates it at the appropriate time. The central system provides data archives, manages the data bus, and provides a timeshare interface for multiple users. The system also hosts software production tools for the battery stations and the central system.

Glover, Richard D.↗

Advances in Land Data Assimilation Systems

Assimilation of remotely sensed land surface observations into regional to global scale numerical models have the potential to significantly advance our ability, to assess, understand, and predict surface water, energy, and carbon cycles. This session seeks to assess the state-of-the-art in data assimilation methods for integrating land surface remote sensing and modeling, with a focus on practical applications and techniques. Assimilated land surface variables of interest include (but are not limited to, soil moisture, surface temperature, snowpack, streamflow, vegetation dynamics, and carbon storage. Contributions describing the development of practical land surface data assimilation methods, multivariate land surface data assimilation strategies, evaluation of the required accuracy and resolution of remote sensing observations, the effects of scale, process complexity, and uncertainty on data assimilation, and the optimal treatment of model and observation errors are encouraged.

Houser, Paul R.↗

Baseline Testing of the Club Car Carryall With Asymmetric Ultracapacitors

The NASA John H. Glenn Research Center initiated baseline testing of the Club Car Carryall with asymmetric ultracapacitors as a way to reduce pollution in industrial settings, reduce fossil fuel consumption, and reduce operating costs for transportation systems. The Club Car Carryall provides an inexpensive approach to advance the state of the art in electric vehicle technology in a practical application. The project transfers space technology to terrestrial use via non-traditional partners, and provides power system data valuable for future space applications. The work was done under the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB). The Carryall is a state of the art, ground up, electric utility vehicle. A unique aspect of the project was the use of a state of the art, long life ultracapacitor energy storage system. Innovative features, such as regenerative braking through ultracapacitor energy storage, are planned. Regenerative braking recovers much of the kinetic energy of the vehicle during deceleration. The Carryall was tested with the standard lead acid battery energy storage system, as well as with an asymmetric ultracapacitor energy storage system. The report concludes that the Carryall provides excellent performance, and that the implementation of asymmetric ultracapacitors in the power system can provide significant performance improvements.

Eichenberg, Dennis J.↗

A Systematic Study to Determine 5G Baseline Performance for Scientific Computing

The fifth-generation (5G) cellular networks envisions achieving higher data rates, improved connectivity, reduced latency, and better quality of service (QoS) than the fourthgeneration (4G) cellular networks. Such improved performance can be utilized to address the challenges in applications such as electricity generation in power systems. The traditional power grids responsible for electricity generation suffer from drawbacks such as life-threatening blackout crises, and energy storage proliferation as they are not robust to extreme climatic conditions. A recent study proposed the idea of extending the capabilities of advanced wireless technologies such as the current 5G to develop a robust, energy-efficient, and secure smart grids. However there are two main challenges associated with the integration of power systems and wireless technologies. First, it is imperative to understand the architecture and the enabling technologies of 5G to ensure that the performance requirements of the smart grids are met. Second, an end-to-end testbed is required to determine if the performance requirements are met by estimating the 5G characteristics such as latency, and throughput. Our proposed alleviates the aforementioned concerns in the following manner. To begin with, a systematic study of the 5G architecture including both the StandAlone (SA) and Non-Standalone (NSA) operations is presented. Furthermore, a detailed survey of the possible 5G enabling technologies is elicited. In addition to these, an end-toend testbed that can estimate the 5G characteristics is explained in detail with appropriate preliminary results.

5G, 5G Communication↗

Real-World Evaluation of National Energy Efficiency Potential of Cold Storage Evaporator Technology in the Context of Engine Start-Stop Systems

National concerns over energy consumption and emissions from the transportation sector have prompted regulatory agencies to implement aggressive fuel economy targets for light-duty vehicles through the U.S. National Highway Traffic Safety Administration/Environmental Protection Agency (EPA) Corporate Average Fuel Economy (CAFE) program. Automotive manufacturers have responded by bringing competitive technologies to market that maximize efficiency while meeting or exceeding consumer performance and comfort expectations. In a collaborative effort among Toyota Motor Corporation, Argonne National Laboratory (ANL), and the National Renewable Energy Laboratory (NREL), the real-world savings of one such technology is evaluated. A commercially available Toyota Highlander equipped with two-phase cold storage technology was tested at ANL’s chassis dynamometer testing facility. The cold storage technology maintains the thermal state of air-conditioning evaporators to enable longer and more frequent engine-off operation in vehicles equipped with start-stop functionality. Test results were analyzed and provided to NREL where a novel simulation framework was developed and calibrated to the test data. The vehicle model was then exercised over a large set of real-world drive cycle and ambient condition data to estimate national-level fuel economy benefits. Results indicate that the cold storage evaporator provided national fuel consumption reductions of 0.113% relative to a conventional evaporator in the same vehicle. In addition, when the cold storage evaporator engine stop/start was enabled for any temperature and the baseline was limited to the EPA menu, Start and Stop credit assumption of 27°C, a national fuel savings of 0.497% was found. Fuel savings resulted from a combination of extended engine-off duration during idle events and increased frequency of deceleration fuel cutoff, both enabled by the ability of the cold storage evaporator to maintain thermal state in situations where air conditioning is active.

DIRECT ENERGY CONVERSION↗

Revenue prediction for integrated renewable energy and energy storage system using machine learning techniques

Revenue estimation for integrated renewable energy and energy storage systems is important to support plant owners or operators’ decisions in battery sizing selection that leads to maximized financial performances. A common approach to optimizing revenues of a hybrid hydro and energy storage system is using mixed-integer linear programming (MILP). Although MILP models can provide accurate production cost estimations, they are typically very computationally expensive. To provide a fast yet accurate first-step information to hydropower plant owners or operators who consider integrating energy storage systems, we propose an innovative approach to predicting optimal revenues of an integrated energy generation and storage system. In this study, we examined the performance of two prediction techniques: Generalized Additive Models (GAMs) and machine learning (ML) models developed based on artificial neural networks (ANN). Predictive equations and models are generated based on optimized solutions from a market participation optimization model, the Conventional Hydropower Energy and Environmental Resource System (CHEERS) model. The two predicting techniques reduce the computational time to evaluate annual revenue for one set of battery configurations from 3 h to 1 to 4 min per run while also being implementable with significantly less data. The model validation prediction errors of developed GAMs and ML models are generally below 5%; for model testing predictions, the ML models consistently outperform the regression equations in terms of root mean square errors. This new approach allows plant owners, operators, or potential investors to quickly access multiple battery configurations under different energy generation and market scenarios. This new revenue prediction method will therefore help reduce the barriers, and thereby promoting the deployment of battery hybridization with existing renewable energy sources.

13 HYDRO ENERGY↗

Electrochemical Compression for Ammonia Storage and Refrigeration System (Phase 2)

In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm 2 of active area. We demonstrated the operation of larger cells with 100 cm 2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state.

25 ENERGY STORAGE↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Time-frequency based cyber security defense of wide-area control system for fast frequency reserve

Global power systems are transiting from conventional fossil fuel energy to renewable energies due to their environmental benefits. The increasing penetration of renewable energies presents challenges for power system operation. The efficiency and sufficiency of responsive reserves have become increasingly important for power systems with a high proportion of renewable energies. The Fast Frequency Reserve (FFR), especially the Wide-area Monitoring System (WAMS)-based FFR, is a promising and effective solution to secure and enhance the stability of power systems. However, cyber security has become a new challenge for the WAMS-based FFR system. Cyber attacks on the FFR control system may threaten the safety of power system operation due to the rapid power controllability requirement of FFR. Therefore, to address this problem, a time-frequency based cyber security defense framework is proposed to detect the cyber spoofing of synchrophasor data in WAMS-based FFR control systems. This paper first introduces the Continuous Wavelet Transforms (CWTs) to decompose spoofing signals. Then, the Dual-frequency Scale Convolutional Neural Networks (DSCNN) is proposed to identify the time-frequency domains matrix from two frequency scales. Integrating CWTs and DSCNN, an identification framework called CWTs-DSCNN is further proposed to detect the spoofing attacks in the WAMS-based FFR system. Multiple experiments using the actual data from FNET/GridEye are performed to verify the effectiveness of the framework in securing WAMS-based FFR systems.

25 ENERGY STORAGE↗

Two-Fluid and Discrete Element Modeling of a Parallel Plate Fluidized Bed Heat Exchanger for Concentrating Solar Power

A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.

concentrating solar power↗

Molecular Structure and Electron Affinity of Metal-Solvent Complexes: Insights from Density Functional Theory Simulations

A molecular level understanding of the structure and energetics of the monovalent and divalent metal ion complexes is of great importance for development of next-generation batteries. Here, Density Functional Theory (DFT) simulations at the ωb97xD/6-31 + G(d,p) level of theory are performed to investigate the interaction of metal ions (Li + , Na + , K + , Mg 2+ , Ca 2+ , Zn 2+ ) with 26 organic solvent molecules. The reduction energetics (electron affinity and reduction potential) and structural responses of the solvent molecules and the molecular complexes are discussed. The DFT calculations are carried out to investigate the structure, energetics and electron affinities of chelated complexes of water (H 2 O), tetrahydrofuran (THF) and di-methoxy ethane (DME) solvent molecules. Additionally, ab initio dynamic simulations (AIMD) at 298 K using atom centered density matrix propagation (ADMP) formalism are performed to understand the spontaneous structure formation upon electron attachment of the metal ion-solvent complexes. The ADMP simulations indicate the decomposition of Mg + -(DME) 3 complex via cleavage of C–O bond of one of the three DME molecules indicating irreversible decomposition of DME in the presence of the Mg + radical. We believe that the data collected as part of this investigation serves as a library of fundamental knowledge towards a deeper understanding of the electrode-electrolyte interfacial reactions.

25 ENERGY STORAGE↗

SunLine Transit Agency Fuel Cell Electric Bus Progress Report (Data Period Focus Jan-Jun 2020) [Slides]

This report presents early results from a deployment of fuel cell electric buses (FCEBs) operated by SunLine Transit Agency in the Coachella Valley area of California. The five FCEBs, produced by New Flyer, feature an electric drive propulsion system powered by a Ballard fuel cell system. The project team is collaborating with the U.S. Department of Energy (DOE) and DOE's National Renewable Energy Laboratory (NREL) to evaluate the buses in revenue service. The goal of this evaluation is to compare the FCEB performance to that of conventional technology and to track progress over time toward meeting the technical targets set by DOE and the Department of Transportation (DOT). The FCEBs were delivered beginning in mid-2019. The data period covers January 2020 through July 2020. NREL collects data on five 2019 model year compressed natural gas (CNG) buses as a baseline comparison at SunLine. These new CNG buses were phased into service beginning in April 2020.

25 ENERGY STORAGE↗

Coordinated Thermal Safety Attack and Defense on EV Battery Management Systems

Battery temperature sensor and battery current sensor data which are key sensing inputs to the Battery Management Controllers in electric vehicles, are vulnerable to possible cyber/ physical manipulation due to known vulnerabilities inherited from CAN bus technology that is used for in-vehicle communications between electronic control units that transfer sensing and control data. In this paper, we first create a simulation that enables us to evaluate impact of cyber physical attacks on electric vehicle battery management system in a controlled environment that violates thermal safety. Specifically, we emulate a Level 3 - DC fast charging system with SAE J1772/CCS, integrated with standard charging controls and thermal safety controls on EVs, and various sensing data flows. Second, we propose a coordinated current and battery temperature attack that has crippling economic, and safety impacts. Third, we quantify the usability, economic and safety impacts of such attacks as a function of the extent of data manipulation. Finally, we propose a physics model driven detection technique to detect presence of such attacks.

25 ENERGY STORAGE↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems [Slides]

The study performed two related analyses using data from a new-construction residential community equipped with rooftop solar and storage (S+S) in Arizona. The study analyzed the factors that determine customer electricity cost savings from S+S adoption. The research compared the Arizona case study data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, NREL explored ways to improve such models and, conversely, use modeled results to suggest improvements to S+S dispatches.

14 SOLAR ENERGY↗