Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Whole Foods Market Retrofits Multiple Building Systems for Big Savings

Whole Foods Market partnered with U.S. the Department of Energy (DOE) to develop and implement solutions to reduce annual energy consumption in existing stores by at least 30% versus pre-retrofit energy use at its store in Edgewater, New Jersey, as part of DOE’s Commercial Building Partnership (CBP) program.

eem↗

Existing Whole-House Solutions Case Study: Community-Scale Energy Modeling - Southeastern United States

Community-scale energy modeling and testing are useful for determining energy conservation measures that will effectively reduce energy use. To that end, IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following ASHRAE Guideline 14 normalization procedures, electricity consumption of 1,166 all-electric, production-built homes was modeled. The homes were in two communities: one built in the 1970s and the other in the mid-2000s.

ASHRAE GUIDELINE 14↗

Existing Whole-House Solutions Case Study: Cascade Apartments - Deep Energy Multifamily Retrofit

In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington, which resulted in annual energy cost savings of 22%, improved comfort and air quality for residents, and increased durability of the units. This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary Building America research questions: 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio of the retrofit package after considering utility window incentives and KCHA capital improvement funding.

BA-PIRC↗

Existing Whole-House Solutions Case Study: National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island

Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects, and was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

airtightness↗

2016 Renewable Energy Grid Integration Data Book

The 2016 Renewable Energy Grid Integration Data Book identifies the status, key trends, challenges, and solutions of renewable energy grid integration in a highly visual format.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2016 Renewable Energy Grid Integration Data Book

The 2016 Renewable Energy Grid Integration Data Book identifies the status, key trends, challenges, and solutions of renewable energy grid integration in a highly visual format. This data book provides an overview of selected key grid integration metrics that represent complex interactions among generation characteristics, market rules, and environmental and safety factors, which may vary by geography, season, and time of day; and presents metrics that either indicate how much variable renewable energy (VRE) is currently being integrated onto the grid, or measure factors that may increase or decrease the challenges associated with integrating VRE generation onto the grid.

variable, renewable, grid, integration, wind, sola↗

2018 Renewable Energy Grid Integration Data Book

The 2018 Renewable Energy Grid Integration Data Book identifies the status, key trends, challenges, and solutions of renewable energy grid integration in a highly visual format. It provides an overview of selected key grid integration metrics that represent complex interactions among generation characteristics, market rules, and environmental and safety factors, which may vary by geography, season, and time of day; and the data book presents metrics that either indicate how much variable renewable energy (VRE) is currently being integrated onto the grid or measure factors that may increase or decrease the challenges associated with integrating VRE generation onto the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Alloying effects on low-energy recoil events in concentrated solid-solution alloys

Alloying elements at low-concentrations into pure metals is usually adopted to improve their mechanical properties and irradiation performance. Recently developed single-phase concentrated solid-solution alloys (CSAs) comprised of two or more elements, all at high concentrations, have demonstrated good radiation resistance. CSAs are characterized by their extreme disordered states that arise from the random arrangement of different elements and accompanied random local lattice distortions. In this work, we investigate low-energy recoil events in Ni 0.5 X 0.5 (X = Fe and Co) CSAs and Ni 0.8 X 0.2 (X = Fe, Co, Cr, and Pd) CSAs using ab initio molecular dynamics simulations to understand the effects of different disorder on defect production in CSAs. The threshold displacement energies are determined along three high-symmetric directions by randomly choosing independent primary knock-on atoms in each direction. As expected, the threshold energies in Ni and its CSAs are anisotropic, with the highest values found in the [111] direction. The calculated threshold energies of Fe in NiFe are smaller than those in NiCo and Ni, especially along the [111] direction. An inspection of the atomic trajectories inside the collision cascade reveals that the effect of chemical disorder outweighs the site-to-site lattice distortions in determining the threshold energies. Especially, different interaction properties between elements due to their different electronic structures are responsible for the observed different threshold energies. Finally, the local environment dependence of threshold energies suggests that local elemental arrangement can be used to understand and predict threshold energies in disordered alloys.

36 MATERIALS SCIENCE↗

Innovative Utility Offerings at the Distribution Edge: Case Studies from Around the Globe

The global evolution of the electricity sector - from deregulation, to higher penetrations of DERs, to digitization and changing consumer preferences - has delivered the utility industry to an inflection point. The vertically integrated, regulated model that persisted over most of the 20th century is undergoing a transformation, and utilities worldwide are responding with new approaches to the provision of products and services. This report catalogs several of these innovative approaches to incorporate new technologies such as electric vehicles, meet societal goals for a cleaner, more efficient electricity system, and empower consumers to make smarter energy choices and provide system benefits. The report comprises a series of 10 case studies across six continents, and features solutions touching on energy supply, energy efficiency, lighting, transport, data, heating and cooling, and rural/off-grid solutions. The diversity of products, programs, and markets documented illustrates the extent of the shift underway. Ultimately, the report demonstrates that utilities will continue to serve as critical partners in a global energy transition, and have been actively engaged in securing their position as such.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of stacking fault energy on damage microstructure in ion-irradiated CoCrFeNiMn concentrated solid solution alloys

In order to understand the effect of stacking fault energy on microstructural evolution in concentrated solid solution alloys, Kr 2+ ion irradiation was performed for FCC-type CoCrFeNiMnx alloys. During Kr 2+ ion irradiation at 500 degrees C the formation of black dots, self-interstitial atom faulted loops and perfect loops were observed, but no observable voids were found in all the alloys. The comparison of microstructural evolution among CoCrFeNiMn x (x = 0.7, 1, 1.3) alloys revealed less faulted loop number density and size in CoCrFeNiMn 1.3 . The stacking fault energy of each alloy was investigated using the deformed CoCrFeNiMn x alloys, and it was revealed that CoCrFeNiMn 1.3 had the highest stacking fault energy, which is higher value than that of 316SS. From these results, it is suggested that FeCrNiMn-based concentrated solid solution alloys could be well-designed by controlling the stacking fault energy with optimized Mn concentration as one of high radiation resistance structure materials. (C) 2020 Elsevier B.V. All rights reserved.

36 MATERIALS SCIENCE↗

ON THE VERTICAL EQUILIBRIUM OF THE LOCAL GALACTIC DISK AND THE SEARCH FOR DISK DARK MATTER

Estimates of the dynamical surface mass density at the solar Galactocentric distance are commonly derived assuming that the disk is in vertical equilibrium with the Galactic potential. This assumption has recently been called into question, based on the claim that the ratio between the kinetic and the gravitational energy in such solutions is a factor of three larger than required if virial equilibrium is to hold. Here we show that this ratio between energies was overestimated and that the disk solutions are likely to be in virial equilibrium after all. We additionally demonstrate, using one-dimensional numerical simulations, that the disks are indeed in equilibrium. Hence, given the uncertainties, we find no reason to cast doubt on the steady-state solutions which are traditionally used to measure the matter density of the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

An Analytic Benchmark for Neutron Boltzmann Transport with Downscattering—Part I: Flux and Eigenvalue Solutions

Computing in the energy dimension is one of the greatest challenges confronting present-day deterministic neutron transport solvers. Accurately resolving the neutron flux as neutrons downscatter across resonances in the nuclear cross sections currently requires considerable computing power and suffers from approximation errors. Flux uncertainty resulting from the uncertainty of the resonance structure is the single-largest cause of reactivity uncertainty. Any additional reference solution for the critical neutron downscattering problem with resonance phenomena would be a boon to verification and validation of neutronics codes. This paper establishes a benchmark to verify the accuracy of neutron transport criticality solvers along the energy dimension. For the first time, the analytic solution of the flux amplitude is derived in the particular case of an infinite homogeneous medium with isotropic scattering in the center of mass and an arbitrary number of no-threshold, neutral particle reaction resonances (e.g., radiative capture, fission, and resonance scattering). Furthermore, original analytic expressions are established to quantify the discrepancy between the ψ k (E) and ψ α (E) flux amplitudes, respective solutions of the multiplication factor k, or the exponential time-evolution frequency α eigenproblems. The physical study of these relations led to analysis of their first-order relative difference near the criticality condition α=0. Finally, numerical solutions are provided to a benchmark problem constituted of the first resonance of 239 Pu, the 6.67-eV resonance of 238 U, and a scattering isotope with a flat cross section, allowing for the computational verification of the energy resolution of current neutron transport criticality codes. Through these novel results, this analytic benchmark can serve as a reference to verify the energy resolution and sensitivity analysis of neutron transport criticality calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the grand-canonical partition function using expanded Wang-Landau simulations. III. Impact of combining rules on mixtures properties

Combining rules, such as the Lorentz-Berthelot rules, are routinely used to calculate the thermodynamic properties of mixtures using molecular simulations. Here we extend the expanded Wang-Landau simulation approach to determine the impact of the combining rules on the value of the partition function of binary systems, and, in turn, on the phase coexistence and thermodynamics of these mixtures. We study various types of mixtures, ranging from systems of rare gases to biologically and technologically relevant mixtures, such as water-urea and water-carbon dioxide. Comparing the simulation results to the experimental data on mixtures of rare gases allows us to rank the performance of combining rules. We find that the widely used Lorentz-Berthelot rules exhibit the largest deviations from the experimental data, both for the bulk and at coexistence, while the Kong and Waldman-Hagler provide much better alternatives. In particular, in the case of aqueous solutions of urea, we show that the use of the Lorentz-Berthelot rules has a strong impact on the Gibbs free energy of the solute, overshooting the value predicted by the Waldman-Hagler rules by 7%. This result emphasizes the importance of the combining rule for the determination of hydration free energies using molecular simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum mechanics/molecular mechanics minimum free-energy path for accurate reaction energetics in solution and enzymes: Sequential sampling and optimization on the potential of mean force surface

To accurately determine the reaction path and its energetics for enzymatic and solution-phase reactions, we present a sequential sampling and optimization approach that greatly enhances the efficiency of the ab initio quantum mechanics/molecular mechanics minimum free-energy path (QM/MM-MFEP) method. In the QM/MM-MFEP method, the thermodynamics of a complex reaction system is described by the potential of mean force (PMF) surface of the quantum mechanical (QM) subsystem with a small number of degrees of freedom, somewhat like describing a reaction process in the gas phase. The main computational cost of the QM/MM-MFEP method comes from the statistical sampling of conformations of the molecular mechanical (MM) subsystem required for the calculation of the QM PMF and its gradient. In our new sequential sampling and optimization approach, we aim to reduce the amount of MM sampling while still retaining the accuracy of the results by first carrying out MM phase-space sampling and then optimizing the QM subsystem in the fixed-size ensemble of MM conformations. The resulting QM optimized structures are then used to obtain more accurate sampling of the MM subsystem. This process of sequential MM sampling and QM optimization is iterated until convergence. The use of a fixed-size, finite MM conformational ensemble enables the precise evaluation of the QM potential of mean force and its gradient within the ensemble, thus circumventing the challenges associated with statistical averaging and significantly speeding up the convergence of the optimization process. To further improve the accuracy of the QM/MM-MFEP method, the reaction path potential method developed by Lu and Yang [Z. Lu and W. Yang, J. Chem. Phys. 121, 89 (2004)] is employed to describe the QM/MM electrostatic interactions in an approximate yet accurate way with a computational cost that is comparable to classical MM simulations. The new method was successfully applied to two example reaction processes, the classical S{sub N}2 reaction of Cl{sup -}+CH{sub 3}Cl in solution and the second proton transfer step of the reaction catalyzed by the enzyme 4-oxalocrotonate tautomerase. The activation free energies calculated with this new sequential sampling and optimization approach to the QM/MM-MFEP method agree well with results from other simulation approaches such as the umbrella sampling technique with direct QM/MM dynamics sampling, demonstrating the accuracy of the iterative QM/MM-MFEP method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative evaluation of solar, fission, fusion, and fossil energy resources, part 3

The role of nuclear fission reactors in becoming an important power source in the world is discussed. The supply of fissile nuclear fuel will be severely depleted by the year 2000. With breeder reactors the world supply of uranium could last thousands of years. However, breeder reactors have problems of a large radioactive inventory and an accident potential which could present an unacceptable hazard. Although breeder reactors afford a possible solution to the energy shortage, their ultimate role will depend on demonstrated safety and acceptable risks and environmental effects. Fusion power would also be a long range, essentially permanent, solution to the world's energy problem. Fusion appears to compare favorably with breeders in safety and environmental effects. Research comparing a controlled fusion reactor with the breeder reactor in solving our long range energy needs is discussed.

Clement, J. D.↗