Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Testing the Solar Probe Cup, an Instrument Designed to Touch the Sun

Solar Probe Plus will be the first, fastest, and closest mission to the sun, providing the first direct sampling of the sub-Alfvenic corona. The Solar Probe Cup (SPC) is a unique re-imagining of the traditional Faraday Cup design and materials for immersion in this high temperature environment. Sending an instrument of this type into a never-seen particle environment requires extensive characterization prior to launch to establish sufficient measurement accuracy and instrument response. To reach this end, a slew of tests for allowing SPC to see ranges of appropriate ions and electrons, as well as a facility that reproduces solar photon spectra and fluxes for this mission. Having already tested the SPC at flight like temperatures with no significant modification of the noise floor, we recently completed a round of particle testing to see if the deviations in Faraday Cup design fundamentally change the operation of the instrument. Results and implications from these tests will be presented, as well as performance comparisons to cousin instruments such as those on the WIND spacecraft.

Whittlesey, Phyllis L.↗

Mitigating Green's function Monte Carlo signal-to-noise problems using contour deformations

The Green's function Monte Carlo (GFMC) method provides accurate solutions to the nuclear many-body problem and predicts properties of light nuclei starting from realistic two- and three-body interactions. Controlling the GFMC fermion-sign problem is crucial, as the signal-to-noise ratio decreases exponentially with Euclidean time, requiring significant computing resources. Inspired by similar scenarios in lattice quantum field theory and spin systems, in this work, we employ integration contour deformations to improve the GFMC signal-to-noise ratio. Machine learning techniques are used to select optimal contours with minimal variance from parameterized families of deformations. As a proof of principle, we consider the deuteron binding energies and Euclidean density response functions. We only observe mild signal-to-noise improvement for the binding energy case. On the other hand, we achieve an order of magnitude reduction of the variance for Euclidean density response functions, paving the way for computing electron- and neutrino-nucleus cross-sections of larger nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron Density Power Spectrum in the Local Interstellar Medium

Interstellar scintillation (ISS), fluctuations in the amplitude and phase of radio waves caused by scattering in the interstellar medium, is important as a diagnostic of interstellar plasma turbulence. ISS is also of interest because it is noise for other radio astronomical observations.

interstellar↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Overcoming Variability: A Reproducible Approach to SERS Detection of Nanodiamonds

Detonation nanodiamonds (DNDs) are formed at specific pressures and temperatures during explosions. Different explosives produce varied yields of DNDs within their detonation soot, with Composition B producing the highest yield. Raman spectroscopy (RS) is often used for the characterization of sp 2 - and sp 3 -hybridized carbon allotropes in carbonaceous materials because of distinct disorder and graphitic bands. Bulk diamond also gives a distinct Raman peak at 1332 cm –1 . Furthermore, as bulk diamond decreases in size to nanometer-sized species, the peak red-shifts and broadens, becoming increasingly difficult to detect with RS using visible excitations. Therefore, surface-enhanced Raman spectroscopy (SERS) was used to enhance the diamond peak of DNDs, enabling better detection and faster examination of DNDs within detonation soot. Previous literature of the SERS of DNDs delivered inconsistent results in spectral signatures and SERS substrates. Herein, refining of the methodology for the acquisition of SERS spectra of DNDs was achieved. Before any SERS experiments, the DNDs were first characterized with normal Raman (NR) and scanning electron microscopy. Two routes for SERS enhancement were evaluated: colloidal noble metal nanoparticles and evaporated silver films. Silver films produced the best signal enhancement of DNDs with the best signal-to-noise and peak enhancements observed at 20–30 nm thick silver films at 5% (∼300 μW) laser power. Consistent, reproducible SERS spectra were acquired of small aggregates of DNDs down to ∼500 nm. NR and SERS mapping analysis of DNDs before and after evaporation of silver films revealed the improvements in the detection capabilities of SERS compared with NR.

Carbon↗

CryoTEN: efficiently enhancing cryo-EM density maps using transformers

Abstract Motivation Cryogenic electron microscopy (cryo-EM) is a core experimental technique used to determine the structure of macromolecules such as proteins. However, the effectiveness of cryo-EM is often hindered by the noise and missing density values in cryo-EM density maps caused by experimental conditions such as low contrast and conformational heterogeneity. Although various global and local map-sharpening techniques are widely employed to improve cryo-EM density maps, it is still challenging to efficiently improve their quality for building better protein structures from them. Results In this study, we introduce CryoTEN—a 3D UNETR++ style transformer to improve cryo-EM maps effectively. CryoTEN is trained using a diverse set of 1295 cryo-EM maps as inputs and their corresponding simulated maps generated from known protein structures as targets. An independent test set containing 150 maps is used to evaluate CryoTEN, and the results demonstrate that it can robustly enhance the quality of cryo-EM density maps. In addition, automatic de novo protein structure modeling shows that protein structures built from the density maps processed by CryoTEN have substantially better quality than those built from the original maps. Compared to the existing state-of-the-art deep learning methods for enhancing cryo-EM density maps, CryoTEN ranks second in improving the quality of density maps, while running >10 times faster and requiring much less GPU memory than them. Availability and implementation The source code and data are freely available at https://github.com/jianlin-cheng/cryoten.

Biochemistry & Molecular Biology↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗

Exploring New Diamond Surfaces with Precision Chemistry and Quantum Spectroscopy

Point defects in diamond known as color centers are a promising platform for quantum sensing. As atom-like systems, they can exhibit excellent spin coherence and can be manipulated with light. As solid-state defects, they can be produced at high densities and be incorporated into scalable devices. Diamond is a uniquely excellent host; it has a large band gap, can be synthesized with sub-ppb impurity concentrations, and can be isotopically purified to eliminate magnetic noise from nuclear spins. Specifically, the nitrogen vacancy (NV) center has been demonstrated to be a highly sensitive, non-invasive magnetic probe capable of resolving the magnetic field of a single electron spin with nanometer spatial resolution. However, the development of NV centers and other color centers in diamond as a quantum platform crucially relies on developing methods to functionalize and process diamond surfaces. Diamond is the hardest material, making polishing and processing challenging, and diamond surfaces are inert and sterically hindered, making them notoriously difficult to chemically terminate and functionalize. Our approach is to discover new surface chemistries for diamond by combining multimodal surface spectroscopy with NV-based quantum spectroscopy to carefully characterize the diamond surface. We have developed a suite of techniques for characterizing the diamond surface using rapid tools for reaction screening and detailed surface spectroscopy tools for definitive identification of the surface bonding.

36 MATERIALS SCIENCE↗

Compact carbon monoxide sensor utilizing a confocal optical cavity.

The carbon monoxide sensor discussed in this paper utilizes a unique confocal cavity which allows the complete system to be packaged in a small volume suitable for hand-held use. The optical system is the heart of the instrument with equal emphasis placed on the electronics support circuitry, consisting essentially of a thermal infrared pyroelectric detector and lock-in amplifier. The pyroelectric detector offers a major advantage over other thermal detectors, providing a signal-to-noise ratio and detectivity that remain nearly constant over the frequency range from dc to 2000 Hz. Since bias voltage is not required, low frequency noise is not generated in the detector.

Scott, B.↗

A new radio emission at 3 kHz in the outer heliosphere

Evidence of a radio source in the outer heliosphere based on observations made by the plasma wave receivers on Voyagers 1 and 2 at heliocentric radial distances ranging from 13 to 20 AU is given. The radio emission is observed in the frequency range 2 to 3 kHz, and is above the local electron plasma frequency whenever supporting plasma density data are available. The maximum spectral density of the emission is 10 to the minus 14 th power V sq/m/Hz. The bandwidth of the radio noise is 1 kHz. One possible source for the emission is radiation at the second harmonic of the plasma frequency at the heliopause.

Kurth, W. S.↗

Spatial compression of Seasat SAR imagery

The results of a study of techniques for spatial compression of synthetic-aperture-radar (SAR) imagery are summarized. Emphasis is on image-data volume reduction for archive and online storage applications while preserving the image resolution and radiometric fidelity. A quantitative analysis of various techniques, including vector quantization (VQ) and adaptive discrete cosine transform (ADCT), is presented. Various factors such as compression ratio, algorithm complexity, and image quality are considered in determining the optimal algorithm. The compression system requirements are established for electronic access of an online archive system based on the results of a survey of the science community. The various algorithms are presented and their results evaluated considering the effects of speckle noise and the wide dynamic range inherent in SAR imagery. The conclusion is that although the ADCT produces the best signal-to-distortion-noise ratio for a given compression ratio, the two-level tree-searched VQ technique is preferred due to its simplicity of decoding and near-optimal performance.

Chang, C. Y.↗

Vector Quantization With Emergent Codebook Structure

Proposed scheme under development for transmission of vector-quantized digital video images, vector quantizer codebook updated to adapt quantizer to changing signal statistics. Intended to be realized with electronic neural network. Codebook, which consists of patterns constituting video images, will undergo training during operation and scheme will develop codebooks ordered during training. System enables coding more compact, more immune to noise, and supports variable rate compression.

Ahalt, Stanley C.↗

A radiation-hard, low-background multiplexer design for spacecraft imager applications

A possible multiplexer design for the focal plane for the Cassini Visible and Infrared Mapping Spectrometer (VIMS) is reviewed. The instrument's requirements for the multiplexed array are summarized. The VIMS instrument has a modest radiation-hardness requirement due to the trajectory and planetary environments in which the instrument will be required to operate. The total ionizing dose hardness requirement is a few tens of kilorads. A thin-gate oxide of a few hundred angstroms thickness is to be used. Field hardness is to be achieved by guard bands or hardened dielectric isolation. The design is argued to meet the low-noise and radiation-hardness required for imaging at Saturn. The design is versatile enough to provide double-correlated and double-uncorrelated sampling, which is accomplished in the signal processing electronics outside the focal plane.

Staller, Craig↗

Evolution of a localized Langmuir packet in the solar wind and on auroral field lines

Langmuir emissions in space are reported to be clumpy and intermittent. The high-frequency wave power appears concentrated in spatial packets, whether amidst the solar wind or on auroral field lines. Due to the plasma motion relative to the spacecraft, determining the source for the wave free energy in the three-dimensional electron distribution function has always been difficult, since the unstable features pass by the detector in presumably too short time to be measured. The range of unstable phase velocities and growth rates have generally been estimated rather than determined by unequivocal measurements. The analysis of wave-particle interactions in a space environment has taken recently a new turn with the development of wave correlators on board rockets and satellites. Such instruments seek to identify correlations between the phase of the wave-field and the fluxes of energetic particles. The data interpretation is complex, however, it must be backed by a detailed theoretical understanding of the wave-particle interaction, including the phase relation for inhomogeneous packets. To this end Langmuir packets interacting with fast electrons can be studied in the appropriate regime by means of particle-in-cell simulations, provided that one succeeds in reducing the level of the fluctuations, enhancing the signal-to-noise ratio, and incorporating the appropriate boundary conditions. The first results of such simulations are presented here as a test and expansion of previous analysis.

Roth, I.↗

Opto-Electronic Oscillator Using Suppressed Phase Modulation

A proposed opto-electronic oscillator (OEO) would generate a microwave signal having degrees of frequency stability and spectral purity greater than those achieved in prior OEOs. The design of this system provides for reduction of noise levels (including the level of phase noise in the final output microwave signal) to below some of the fundamental limits of the prior OEOs while retaining the advantages of photonic generation of microwaves.

Dick, G. John↗

GX 3+1: The Stability of Spectral Index as a Function of Mass Accretion Rate

We present an analysis of the spectral and timing properties observed in X-rays from neutron star (NS) binary GX 3+1 (4U 1744-26) during long-term transitions between the faint and bright phases superimposed on short-term transitions between lower banana (LB) and upper banana (UB) branches in terms of its color-color diagram, We analyze all observations of this source obtained with the Rossi X-ray Timing Explorer and BeppoSAX satellites, We find that the X-ray broadband energy spectra during these spectral transitions can be adequately reproduced by a composition of a low-temperature blackbody component, a Comptonized component (COMPTB), and Gaussian component We argue that the electron temperature kTe of the Compton cloud monotonically increases from 2.3 keY to 4.5 keY, when GX 3+1 makes a transition from UB to LB. We also detect an evolution of noise components (a very low frequency noise and a high-frequency noise) during these LB-UB transitions. Using a disk seed photon normalization of COMPTB, which is proportional to the mass accretion rate, we find that the photon power-law index Gamma is almost constant (Gamma = 2.00 +/- 0.02) when mass accretion rate changes by factor four. In addition, we find that the emergent spectrum is dominated by the strong Comptonized component We interpret this quasi-stability of the index Gamma and a particular form of the spectrum in the framework of a model in which the energy release in the transition layer located between the accretion disk and NS surface dominates that in the disk. Moreover, this index stability effect now established for GX 3+ I was previously found in the atoll source 4U 1728-34 and suggested for a number of other low-mass X-ray NS binaries. This intrinsic behavior of NSs, in particular for atoll sources, is fundamentally different from that seen in black hole binary sources where the index monotonically increases during spectral transition from the low state to the high state and then finally saturates at high values of mass accretion rate.

Seifana, Elena↗

Testing the Solar Probe Cup, An Instrument Designed to Touch The Sun

Abstract: Solar Probe Plus will be the first, fastest, and closest mission to the Sun, providing the first direct sampling of the sub-Alfvénic corona. The Solar Probe Cup (SPC) is a unique re-imagining of the traditional Faraday Cup design and materials for immersion in this high temperature environment. Sending an instrument of this type into a never-seen particle environment requires extensive characterization prior to launch to establish sufficient measurement accuracy and instrument response. To reach this end, a slew of tests are created for allowing SPC to see ranges of appropriate ions and electrons, as well as a facility that reproduces solar photon spectra and fluxes for this mission. Having already tested the SPC at flight-like temperatures with no significant modification of the noise floor, we recently completed a round of particle testing to see if the deviations in Faraday Cup design fundamentally change the operation of the instrument. Results and implications from these tests will be presented, as well as performance comparisons to cousin instruments such as those on the WIND spacecraft.

solar physics↗