Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Flavor-violating ALPs, electron g − 2 , and the Electron-Ion Collider

We revisit the possibility that light axionlike particles (ALPs) with lepton-flavor-violating couplings could give significant contributions to the electron’s anomalous magnetic moment g e − 2 . Unlike flavor diagonal lepton-ALP couplings, which are exclusively axial, lepton-flavor-violating couplings can have arbitrary chirality. Focusing on the e − τ ALP coupling, we find that the size of the contribution to g e − 2 depends strongly on the chirality of the coupling. A significant part of the parameter space for which such a coupling can explain experimental anomalies in g e − 2 can be probed at the Electron-Ion Collider, which is uniquely sensitive to the chirality of the coupling using the polarization of the electron beam. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma Mirrors For High Power Lasers: A new approach for high repetition rates combined with realistic PIC simulations

We describe a research program to develop high quality plasma mirrors for use with high repetition rate, high power laser facilities to greatly facilitate experiments in high energy density physics, particularly when using solid density targets. A system delivering ultrathin, free standing liquid crystal films that could handle PW class laser pulses was developed that preserved the laser beam image quality and improved pulse contrast by over two orders of magnitude. The pulse contrast improvement was measured using a high dynamic range cross-correlation. The system operated at a repetition rate of several PMs formed in situ per minute. Extension to 1 Hz repetition rates should be possible. As a practical application, a PM system was used to separate laser accelerated electrons from the ultrashort pulse drive laser so that the electron beam emittance could be directly measured. The 20 nm thick PMs did not contribute significantly to emittance degradation. It was also demonstrated that the films could operate in the difficult plasma and laser environment present for GeV laser based electron acceleration. PM operation is still not well understood and much work with PMs is done empirically. Accordingly, we also demonstrated a particle-in-cell based simulation technique that would model PM operation, tracking the PM operation from cold, neutral atoms to a hot dense plasma by accounting for multiphoton ionization, plasma collisionality, and the dynamically changing index of refraction. Simulations in 3D were compared to a 2D based approach that was comparable. Finally, we developed a simpler model that can predict the intensity at which a plasma mirror will have its peak reflectivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in Hybrid Plasma Wakefield Acceleration

Plasma wakefield accelerators can be driven either by intense laser pulses (LWFA) or by intense particle beams (PWFA). A third approach that combines the complementary advantages of both types of plasma wakefield accelerator has been established with increasing success over the last decade and is called hybrid LWFA→PWFA. Essentially, a compact LWFA is exploited to produce an energetic, high-current electron beam as a driver for a subsequent PWFA stage, which, in turn, is exploited for phase-constant, inherently laser-synchronized, quasi-static acceleration over extended acceleration lengths. The sum is greater than its parts: the approach not only provides a compact, cost-effective alternative to linac-driven PWFA for exploitation of PWFA and its advantages for acceleration and high-brightness beam generation, but extends the parameter range accessible for PWFA and, through the added benefit of co-location of inherently synchronized laser pulses, enables high-precision pump/probing, injection, seeding and unique experimental constellations, e.g., for beam coordination and collision experiments. We report on the accelerating progress of the approach achieved in a series of collaborative experiments and discuss future prospects and potential impact.

43 PARTICLE ACCELERATORS↗

Controlling beam trajectory and transport in a tapered helical undulator

In this paper we present a detailed discussion of the helical undulator system developed for high extraction efficiency experiments in the tapered-enhanced stimulated superradiant amplification regime. The design is based on permanent magnet technology and comprises two Halbach arrays orthogonally oriented and shifted by 90° with respect to each other. When used in low energy beamlines for THz generation, the electron beam trajectory and transport are particularly sensitive to the undulator off-axis fields so that it becomes important to complement on-axis field measurements with analysis and tuning of the higher-order field components. Here we describe how the pulsed wire measurement technique can be effectively used to retrieve on- and off-axis magnetic field characteristics of the undulator. A simple two-dipole model is developed to guide the final adjustments to the permanent magnet positions along the array to tune the quadrupole and sextupole components of the field.

free-electron lasers↗

Polarization-Dependent Self-Injection by Above Threshold Ionization Heating in a Laser Wakefield Accelerator

Here, we report on the experimental observation of a decreased self-injection threshold by using laser pulses with circular polarization in laser wakefield acceleration experiments in a nonpreformed plasma, compared to the usually employed linear polarization. A significantly higher electron beam charge was also observed for circular polarization compared to linear polarization over a wide range of parameters. Theoretical analysis and quasi-3D particle-in-cell simulations reveal that the self-injection and hence the laser wakefield acceleration is polarization dependent and indicate a different injection mechanism for circularly polarized laser pulses, originating from larger momentum gain by electrons during above threshold ionization. This enables electrons to meet the trapping condition more easily, and the resulting higher plasma temperature was confirmed via spectroscopy of the XUV plasma emission.

43 PARTICLE ACCELERATORS↗

LDMX -- The Light Dark Matter eXperiment

LDMX, The Light Dark Matter eXperiment, is a missing momentum search for hidden sector dark matter in the MeV to GeV range. It will be located at SLAC in End Station A, and will employ an 8 GeV electron beam parasitically derived from the SLAC LCLS-II accelerator. LDMX promises to expand the experimental sensitivity of these searches by between one and two orders of magnitude depending on the model. It also has sensitivity in visible ALP searches as well as providing unique data on electron-nucleon interactions.

Appert, Stephen [Caltech]↗

Study of electron-induced chemical transformations in polymers

In extreme ultraviolet (EUV) photoresist exposure, the primary and secondary electrons drive chemistry rather than the EUV photons themselves. These electrons have a wide range of energies below approximately 80 eV, which are capable of complex network of reactions during exposure. To better understand the ability of electrons of different energies within the EUV primary and secondary electron range, we want to characterize and compare the chemistry induced in pure polymer films by direct exposure to electrons. Thin films of poly(tert-butyl methacrylate), poly(methyl methacrylate), and poly(4-hydroxystyrene) were exposed to a 20 to 80 eV electron beam. Outgassing during exposure was characterized in-situ using a quadrupole residual gas analyzer. The thickness changes were measured using ellipsometry and chemical bond structure data were collected using Fourier-transform infrared spectroscopy (FTIR) after exposure to compare different exposure conditions. Poly(4-hydroxystyrene) demonstrated stability during electron exposures. Exposures of the other two materials led to outgassing of protecting groups, the intensity of which decayed in time. Outgassing, FTIR, and thickness loss data exhibited approximately linear relationships to each other.

Mueller, Maximillian↗

Measurements of the L-shell X-ray emission of fluorine-like europium

Measurements of the L-shell X-ray emission of fluorine-like europium ions (Eu 54+ ) were made under controlled laboratory conditions on the EBIT-I electron beam ion trap at Livermore using an X-ray calorimeter, extending such measurements to the middle of the rare earth elements. Comparing the calorimeter spectra with atomic data from the flexible atomic code, we have identified and analyzed several prominent n = 3 → n = 2 transitions, including one two-electron, one-photon core changing transition and one electric quadrupole transition. We find that the measured energies are typically up to several eV higher than predicted.

74 ATOMIC AND MOLECULAR PHYSICS↗

NO$\nu$A Far Detector $\nu_e$ Sideband Study Technical Note

Till now the NO$\nu$A experiment has used the Far Detector (FD) electron neutrino (anti-neutrino) events in the energy range 1 < $E_ν$ < 4 GeV in 3-favor neutrino oscillation analysis, to constraint the neutrino oscillation parameters. In this study, we have used the high-energy neutrino (sideband) sample with 4 < $E_ν$ < 12 GeV, dominated heavily by the beam electron neutrino/anti-neutrino background events to constrain the neutrino oscillation parameters. This was done to figure out if an additional power can be obtained in constraining the oscillation parameters by adding this sample to the analysis. This technote discusses the modifications done in the existing framework to add the sideband sample to the standard FD $\nu_e$ predictions and its impact on the neutrino oscillation parameters sensitivity of the NO$\nu$A experiment. Results from the statistics only study and the study including all the existing systematic shifts are reported separately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Niowave Neutron Source Converter: Lead-Bismuth-Eutectic (LBE) Windowless Target Design and Evaluation

Los Alamos National Laboratory (LANL) is working with Niowave on the design and evaluation of their lead-bismuth-eutectic (LBE) windowless target (i.e., neutron source converter). Niowave plans to use 200 kW electron beam at 40 MeV beam energy to produce neutrons by photonuclear reaction with LBE. Then, the neutrons undergo fission at the surrounding uranium target assembly (UTA) to produce Molybdenum 99 (Mo-99) as a fission product, which eventually decays to Technetium-99 (Tc-99m). Tc-99m is one of important radioisotopes that is used for medical diagnostics. LANL conducted 3D multiphysics analysis for the Niowave neutron converter design and provided design assessment in thermohydraulic aspects. LANL conducted radiation transport calculations using Monte-Carlo N-Particle (MCNP) code with unstructured meshing scheme. The 3D volumetric heating profiles in the LBE and Stainless-Steel (SS) housing were imported into multiphase computational fluid dynamics (CFD) to obtain 3D temperature profiles of LBE and SS through conjugate heat transfer (CHT) analysis. The key findings are: LBE film thickness at the center of the beam is approximately 1.6 cm with a maximum LBE velocity of approximately 1.8 m/s, which is below a 2 m/s limit to avoid erosion issues on supporting structures; Heat deposition in the LBE peaks at ~1 cm depth from the LBE free-surface because of the forward interactions of electron, photon, and neutron with LBE; LBE maximum temperature is ~360 °C, which is below LBE evaporation initiative temperature, ~450 °C; LBE-SS interface temperature is ~350 °C, which is below the safety thermal limit to prevent severe corrosion on SS. The results indicate that Niowave’s neutron converter design satisfies both hydraulic and thermal criteria for safe operation. By virtue of such computational analysis, Niowave can move toward establishing an experimental setup to experimentally test their LBE neutron converter. The following sections describe the detailed work done by LANL.

43 PARTICLE ACCELERATORS↗

A High Precision Measurement of the Proton Charge Radius at JLab

The elastic electron-proton (e-p) scattering and the spectroscopy of hydrogen atoms are the two traditional methods to determine the proton charge radius (r p ). In 2010, a new method using muonic hydrogen (µH) 1 spectroscopy reported a r p result that was nearly ten times more precise but significantly smaller than the values from the compilation of all previous r p measurements. This discrepancy is often referred to as the "proton charge radius puzzle". In order to investigate the puzzle, the PRad experiment (E12-11-106) was first proposed in 2011 and performed in 2016 in Hall B at the Thomas Jefferson National Accelerator Facility, with both 1.1 and 2.2 GeV electron beams. The experiment measured the e-p elastic scattering cross sections in an unprecedented low values of momentum transfer squared region (Q 2 = 2.1× 10 -4 -0.06 (GeV/c) 2 ), with a sub-percent precision. The PRad experiment utilized a calorimetric method that was magnetic-spectrometer-free. Its detector setup included a large acceptance and high resolution calorimeter (HyCal), and two large-area, high spatial-resolution Gas Electron Multiplier (GEM) detectors. To have a better control over the systematic uncertainties, the absolute e-p elastic scattering cross section was normalized to that of the well-known Møller scattering process, which was measured simultaneously during the experiment. For each beam energy, all data with different Q 2 were collected simultaneously with the same detector setup, therefore sharing the same integrated luminosity. The windowless H 2 gas-flow target utilized in the experiment largely removed a typical background source, the target cell windows. The proton charge radius was determined as r p = 0.831±0.007 stat. ±0.012 p fm, which is smaller than the average r p from previous e-p elastic scattering experiments, but in agreement with the µH spectroscopic results within the experimental uncertainties.

Source record↗

Probing individual single atom electrocatalyst sites by advanced analytical scanning transmission electron microscopy

Single atom electrocatalysts (SAEs) are promising next-generation materials for promoting a variety of important reactions, such as the oxygen reduction, nitrogen reduction, and CO 2 reduction reactions. While bulk characterization techniques such as X-ray absorption spectroscopy and Mössbauer spectroscopy have significantly enhanced our understanding of these catalysts, direct probing of individual single metal atom sites at the atomic scale is necessary to understand local variations in the properties of these sites and accelerate design and synthesis of improved SAEs. Aberration-corrected scanning transmission electron microscopy (STEM) has become a powerful tool for providing this type of atomic-scale information about SAE metal sites. These sites are typically unstable under the electron beam, however, which, in combination with conventional acquisition methods and detectors, has limited the type and quantity of information obtainable by spectroscopic STEM techniques. Here, we map multiple individual SAE metal sites in a nitrogen-doped carbon containing atomically dispersed Fe and Re (FeReNC) at the atomic scale by direct electron detection electron energy-loss spectroscopy (EELS). Direct electron detection provides an improved signal-to-noise ratio over conventional scintillator-based detectors and enables detection and real space localization of weak signals. In addition, we demonstrate an automated method for identification of metal atom positions, placement of the probe on these sites, and simultaneous EELS and energy dispersive X-ray spectroscopic (EDS) signal acquisition. This simultaneous acquisition of EELS and EDS provides access to the composition and bonding of a wide range of SAE metal sites. In this study, focusing the probe directly on the metal sites also increases the relevant data acquisition rate by more than an order of magnitude over two-dimensional mapping, enabling improved statistical measurements of site properties. The versatility, sensitivity, and speed that these techniques provide enhances our ability to probe the local elemental and chemical environment of a large number of individual SAE metal site structures at the atomic scale, enabling an improved understanding of the variations in the local properties of these electrocatalysts to be gained. As a result, significantly increased information about individual metal sites will be available to future electrochemical studies through these techniques, accelerating the development of advanced SAEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

Assessment of Additive Manufacturing of Particle Accelerator [Slides]

Metal additive manufacturing of copper components has been commercialized on multiple printing modalities; including Bound Metal Deposition (BMD), Laser Powder Bed Fusion (LPBF), and Electron Beam Melting (EBM). BMD was selected at the primary printing modality for this TED because of the availability of the Markforged Metal X machine within the LANL E-2 AM research lab. Linear accelerator (LINAC) structures are similarly demonstrated technology. Accelerator structures are typically made of high purity oxygen-free electronic copper owing to the material’s high electrical and thermal conductivity. Conventionally machined and brazed, welded, or bolted designs are difficult to manufacture and require long lead times.

36 MATERIALS SCIENCE↗

Tapering-enhanced high-efficiency THz waveguide oscillator

Using a waveguide in a THz FEL has been shown to maximize the coupling and enable efficient extraction of relativistic electron beam energy from a single passage through a tapered helical undulator. An oscillator configuration can further boost energy extraction above the single-pass limits and open the door toward very high average power THz sources. Embedding the undulator in an oscillator cavity is particularly useful in combination with high repetition rate electron sources, even if at reduced peak brightness, since recycling a fraction of the radiation as an intense seed can compensate for lower single-pass gain. In this paper, we investigate the efficiency scaling of a tapering-enhanced waveguide oscillator, showcasing its capability for frequency-tuning operation and high-efficiency operation at different wavelengths. Using a thermionic-driven beamline equipped with compression elements, numerical start-to-end simulation results indicate a 16% efficiency at 200 GHz and a 2.1% efficiency at 1.5 THz, resulting in kW-level average power out-coupled in radiation pulses with few hundred μ J energy and tens of MW peak power. Published by the American Physical Society 2024

Yang, Y. N. (ORCID:0009000849540151)↗

A New MCNP6 Electron-Photon Transport Validation Test: The Lockwood Energy Deposition Experiment (V.1.0)

This memo announces the availability of a new validation test for quantifying the accuracy of the MCNP6 electron-photon transport algorithm for use in energy-deposition calculations. Specifically, energy-deposition results are compared with the Lockwood energy-deposition experiment. The comparison includes energy-deposition profiles in a variety of different single-element materials including beryllium, aluminum, carbon, copper, iron, molybdenum, tantalum, and uranium for pencil beam electron sources with energies including 0.05-, 0.1-, 0.3-, 0.5, and 1-MeV and angles of incidence including normal, 30°, and 60° off-normal. The purpose of this memo is to discuss the contents of the Lockwood validation directory and to outline the procedure for generating the input files, running the tests, processing the results, and comparing results to the experimental and numerical benchmark. Each step is mostly automated by a makefile that executes the necessary perl script.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multipulse Optical-Rectification-Based THz Source for Accelerator Applications

THz sources offer the potential for higher frequencies and higher breakdown thresholds in accelerating structures in comparison with conventional RF sources. They also benefit from larger field strengths, field gradients, better beam synchronization and compactness. In this work, we first present the development of a 49μJ single-cycle THz source centered at 0.6 THz that provides fields over 30 MV/m. With further modifications, multicycle pulses were produced, narrowing the bandwidth of the source and potentially easing the coupling of THz radiation to relativistic electron beams and increasing the usability in other areas of research.

Lenz, Maximilian (ORCID:0009000579693042)↗

Relativistic plasma physics in supercritical fields

Since the invention of chirped pulse amplification, which was recognized by a Nobel Prize in physics in 2018, there has been a continuing increase in available laser intensity. Combined with advances in our understanding of the kinetics of relativistic plasma, studies of laser-plasma interactions are entering a new regime where the physics of relativistic plasmas is strongly affected by strong-field quantum electrodynamics (QED) processes, including hard photon emission and electron-positron (e⁻-e⁺) pair production. Additionally, this coupling of quantum emission processes and relativistic collective particle dynamics can result in dramatically new plasma physics phenomena, such as the generation of dense e⁻-e⁺ pair plasma from near vacuum, complete laser energy absorption by QED processes, or the stopping of an ultra-relativistic electron beam, which could penetrate a cm of lead, by a hair's breadth of laser light. In addition to being of fundamental interest, it is crucial to study this new regime to understand the next generation of ultra-high intensity laser-matter experiments and their resulting applications, such as high energy ion, electron, positron, and photon sources for fundamental physics studies, medical radiotherapy, and next generation radiography for homeland security and industry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗