Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Analysis of an astrometric Fizeau interferometer for GAIA

The concepts related to the operation and design of the global astrometric interferometer for astrophysics (GAIA) bring together solutions chosen for the astrometry satellite and interferometric techniques. Like the Hipparcos satellite, GAIA is a continuously scanning instrument for which the integration time on any observed object is limited by the field of view of the detector. If a final astrometric accuracy of 10 microarcsec is aimed at, a field of 1 deg in diameter is needed. A design is presented for the proposed 2.6 m baseline Fizeau interferometer with two 40 cm apertures and overall dimensions compatible with the size of the Ariane 5 payload shroud. It has a 0.9 deg diffraction limited field of view. The response of the optical system to small perturbations on each optical element is given in terms of the fringe visibility, which is shown to be dependent on the sub-aperture spot separation. The robustness of the design to thermal, mechanical and manufacturing errors is discussed. The unavoidable distortion present in wide field optical systems is analyzed in terms of displacement of the interference fringes.

Loiseau, Sacha↗

NASA Tech Briefs, September 2013

Topics include: ISS Ammonia Leak Detection Through X-Ray Fluorescence; A System for Measuring the Sway of the Vehicle Assembly Building; Fast, High-Precision Readout Circuit for Detector Arrays; Victim Simulator for Victim Detection Radar; Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot; Quasi-Linear Circuit; High-Speed, High-Resolution Time-to-Digital Conversion; Li-Ion Battery and Supercapacitor Hybrid Design for Long Extravehicular Activities; Ultrasonic Low-Friction Containment Plate for Thermal and Ultrasonic Stir Weld Processes; High-Powered, Ultrasonically Assisted Thermal Stir Welding; Next-Generation MKIII Lightweight HUT/Hatch Assembly; Centrifugal Sieve for Gravity-Level-Independent Size; Segregation of Granular Materials; Ion Exchange Technology Development in Support of the Urine Processor Assembly; Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material; UltraSail CubeSat Solar Sail Flight Experiment; Mechanism for Deploying a Long, Thin-Film Antenna From a Rover; Counterflow Regolith Heat Exchanger; Acquisition and Retaining Granular Samples via a Rotating Coring Bit; Very-Low-Cost, Rugged Vacuum System; Medicine Delivery Device With Integrated Sterilization and Detection; FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D; Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs; Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer; Complementary Barrier Infrared Detector (CBIRD) Contact Methods; Autonomous Control of Space Nuclear Reactors; High-Power, High-Speed Electro-Optic Pockels Cell Modulator; Covariance Analysis Tool (G-CAT) for Computing Ascent, Descent, and Landing Errors; Enigma Version 12; Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program; Spitzer Telemetry Processing System; Planetary Protection Bioburden Analysis Program; Wing Leading Edge RCC Rapid Response Damage Prediction Tool (IMPACT2); ISSM: Ice Sheet System Model; Automated Loads Analysis System (ATLAS); Integrated Main Propulsion System Performance Reconstruction Process/Models. Phoenix Telemetry Processor; Contact Graph Routing Enhancements Developed in ION for DTN; GFEChutes Lo-Fi; Advanced Strategic and Tactical Relay Request Management for the Mars Relay Operations Service; Software for Generating Troposphere Corrections for InSAR Using GPS and Weather Model Data; Ionospheric Specifications for SAR Interferometry (ISSI); Implementation of a Wavefront-Sensing Algorithm; Sally Ride EarthKAM - Automated Image Geo-Referencing Using Google Earth Web Plug-In; Trade Space Specification Tool (TSST) for Rapid Mission Architecture (Version 1.2); Acoustic Emission Analysis Applet (AEAA) Software; Memory-Efficient Onboard Rock Segmentation; Advanced Multimission Operations System (ATMO); Robot Sequencing and Visualization Program (RSVP); Automating Hyperspectral Data for Rapid Response in Volcanic Emergencies; Raster-Based Approach to Solar Pressure Modeling; Space Images for NASA JPL Android Version; Kinect Engineering with Learning (KEWL); Spacecraft 3D Augmented Reality Mobile App; MPST Software: grl_pef_check; Real-Time Multimission Event Notification System for Mars Relay; SIM_EXPLORE: Software for Directed Exploration of Complex Systems; Mobile Timekeeping Application Built on Reverse-Engineered JPL Infrastructure; Advanced Query and Data Mining Capabilities for MaROS; Jettison Engineering Trajectory Tool; MPST Software: grl_suppdoc; PredGuid+A: Orion Entry Guidance Modified for Aerocapture; Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl; and Space Place Prime.

Source record↗

Research Investigation on Dense Scintillation Glass for Use in Total Absorption Nuclear Cascade Detectors

Three approaches to the development of a high density scintillation glass were investigated: They include the increase of density of glass systems containing cerium - the only systems which were known to show scintillation, the testing of a novel silicate glass system containing significant concentrations of silver produced by ion exchange and never tested previously, and the hot pressing of a diphasic compact of low density scintillation glass with high density passive glass. In first two cases, while ultraviolet excited fluorescence was maintained in the glasses showing high density, scintillation response to high energy particles was not retained in the case of the cerium containing glasses or developed in the case of the silver containing glasses. In the case of the compacts, the extremely long path length caused by the multiple internal reflections which occur in such a body resulted in attenuation even with glasses of high specific transmission. It is not clear why the scintillation efficiency is not maintained in the higher density cerium containing glasses.

Hensler, J. R.↗

Advances in solar and cosmic X-ray astronomy - A survey of experimental techniques and observational results.

The current status of X-ray astronomy is surveyed by reviewing observational results and theoretical conclusions gained within the past two years in areas dealing with the quiet-sun, slowly-varying, and burst components of solar X-radiation and with the features of cosmic X-ray sources. Thermal and nonthermal processes responsible for a wide variety of X-ray emission mechanisms in nature are explained, and characteristics of X radiation from specific solar structures are described. Attention is given to the effects of interstellar and intergalactic matter on cosmic X-rays; the properties of galactic and extragalactic X-ray sources; and the specifications of such instruments as gas-filled ionization detectors, proportional counters, Geiger counters, scintillation detectors, photoelectric detectors, polarimeters, collimators, spectrometers, and imaging systems.

Hoover, R. B.↗

Characterization of gigahertz (GHz) bandwidth photomultipliers

The average impulse response, root-mean-square times jitter as a function of signal level, single photoelectron distribution, and multiphotoelectron dark-count distribution have been measured for two static crossed-field and five electrostatic photomultipliers. The optical signal source for the first three of these tests was a 30 picosecond mode-locked laser pulse at 0.53 micron. The static crossed-field detectors had 2-photoelectron resolution, less than 200 ps rise times, and rms time jitters of 30 ps at the single photoelectron level. The electrostatic photomultipliers had rise times from 1 to 2.5 nanoseconds, and rms time jitters from 160 to 650 ps at the same signal level. The two static crossed-field photomultipliers had ion-feedback-generated dark pulses to the 50-photoelectron level, whereas one electrostatic photomultiplier had dark pulses to the 30-photoelectron level.

Abshire, J. B.↗

Prediction and monitoring of clear air turbulence: An evaluation of the applicability of the rawinsonde system

The applicability of rawinsonde data for either detection or prediction of clear air turbulence is discussed. The mechanism currently believed responsible for the development of CAT is reviewed. Since previous studies determined that the most significant factor for the existence of turbulent layers is the magnitude of the vertical shear, certain theoretically derived shear criteria was applied to statistical and diagnostic comparisons of rawinsonde and Jimsphere/Jimsonde conjunctive vertical profiles. It is determined that the Rawinsonde system cannot reliably be used as a CAT detector in a single-station sense.

Keller, J. L.↗

A search for diffuse band profile variations in the rho Ophiuchi cloud

High signal-to-noise profiles of the broad diffuse interstellar band at 4430 A were obtained on the 2.2-m telescope at the Mauna Kea Observatory, using the newly-developed pulse-counting multi-anode microchannel array detector system in an effort to determine whether the band profile varies with mean grain size as expected if the band is produced by absorbers embedded in grain lattices. The lack of profile variability over several lines of sight where independent evidence indicates that the mean grain size varies shows that lambda 4430 is probably not formed by the same grains that are responsible for interstellar extinction at visible wavelengths. The possibility that this band is created by a population of very small ( approximately 100 A) grains is still viable, as is the hypothesis that it has a molecular origin.

Snow, T. P.↗

The abundances of major elements in Cas A and Tycho supernova remnants

The objective of this program was to map the abundances of major elements such as O, Si, S, and Fe in the supernova remnants, Tycho and Cas A. The approach was based upon using archival cosmic X-ray data from several space missions, notably, the Einstein Observatory, EXOSAT, ROSAT, BBSRT, and ASCA. Two of the missions, Einstein and ROSAT, had high resolution telescopes that provided excellent images, but no spectral information. Two missions with much poorer resolution telescopes, BBXRT and ASCA, gave good spectral information through pulse height of signals in their cooled solid state detector, but rather crude spatial information. Our goal was to extract spectral information from the combined analysis of the Einstein and ROSAT images of Cas A and Tycho and to verify or refine the spectral map by checking its agreement with the BBSRT or ASCA spectra results for larger regions. In particular, we note that the Einstein and ROSAT telescopes have different spectral responses. The Einstein bandwidth includes the 2-4 keV region which is absent from ROSAT. Hence, by forming linear combinations of the Einstein and ROSAT images, we are able to resolve the contributions of the 0.5-2 keV band from the 2-4 keV band. The former contains lines of O and Fe while the latter is dominated by Si and S. We correct for the expansion that has taken place in the remnants during the ten-year interval between the Einstein and ROSAT measurements, but we must assume that no significant spectral changes have occurred during that time. The analysis of the Tycho SNR was completed and the results have been published. A copy of the paper is included. The analysis of Cas A has proved to be more complicated. It is continuing with support from another program. Part of the problem may be due to difficulties in the aspect information which is needed to precisely register the ROSAT and Einstein images.

Gorenstein, P.↗

(abstract) Radiometric Calibration of the Multi-angle Imaging Spectro-Radiometer

The EOS/MISR instrument has completed preflight calibration and characterization of its nine cameras. The radiometric calibration requirements includes absolute radiometric accuracy to 3 percent. To meet this challenging requirement MISR has employed detector based calibration methodology. The source, a 1.65 m integrating sphere, is spatially and spectrally featureless. Thus, when viewing scenes that are likewise homogeneous, the sensor incident radiance is easily retrieved to high accuracy. To enhance the radiance product for arbitrary scene types, however, MISR is planning to incorporate spectral out-of-band, point-spread function deconvolution, and pixel nonuniformity of response corrections. A summary of the preflight calibration is presented in this paper, as well as the error uncertainties for specific scene types with and without these processing corrections.

radiometric calibration EOS MISR↗

Broadband Lidar Technique for Precision CO2 Measurement

Presented are preliminary experimental results, sensitivity measurements and discuss our new CO2 lidar system under development. The system is employing an erbium-doped fiber amplifier (EDFA), superluminescent light emitting diode (SLED) as a source and our previously developed Fabry-Perot interferometer subsystem as a detector part. Global measurement of carbon dioxide column with the aim of discovering and quantifying unknown sources and sinks has been a high priority for the last decade. The goal of Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission is to significantly enhance the understanding of the role of CO2 in the global carbon cycle. The National Academy of Sciences recommended in its decadal survey that NASA put in orbit a CO2 lidar to satisfy this long standing need. Existing passive sensors suffer from two shortcomings. Their measurement precision can be compromised by the path length uncertainties arising from scattering within the atmosphere. Also passive sensors using sunlight cannot observe the column at night. Both of these difficulties can be ameliorated by lidar techniques. Lidar systems present their own set of problems however. Temperature changes in the atmosphere alter the cross section for individual CO2 absorption features while the different atmospheric pressures encountered passing through the atmosphere broaden the absorption lines. Currently proposed lidars require multiple lasers operating at multiple wavelengths simultaneously in order to untangle these effects. The current goal is to develop an ultra precise, inexpensive new lidar system for precise column measurements of CO2 changes in the lower atmosphere that uses a Fabry-Perot interferometer based system as the detector portion of the instrument and replaces the narrow band laser commonly used in lidars with the newly available high power SLED as the source. This approach reduces the number of individual lasers used in the system from three or more to one - considerably reducing the risk of failure. It also tremendously reduces the requirement for wavelength stability in the source putting this responsibility instead on the Fabry-Perot subsystem.

Heaps, William S.↗

Measurement of optical modulation functions in sparsely sampled mosaic focal plane arrays

It is pointed out that the measurement of optical modulation functions for detectors in focal plane arrays may be somewhat more difficult under 'full-up' systems conditions as compared to ideal laboratory conditions. An idealized optical modulation test arrangement is considered along with a full-up scanned system involving an earth mapper in polar orbit. In testing the system in full-up condition, a problem arises with respect to the acquisition of knife edge response data. In order to overcome this problem, a preferred method is developed for obtaining KER data on a single scan. A special 'phased edge' reticle is developed for use in the test set-up. Attention is given to aspects of knife edge reconstruction.

Young, J. B.↗

Fire Safety in the Low-Gravity Spacecraft Environment

Research in microgravity (low-gravity) combustion promises innovations and improvements in fire prevention and response for human-crew spacecraft. Findings indicate that material flammability and fire spread in microgravity are significantly affected by atmospheric flow rate, oxygen concentration, and diluent composition. This information can lead to modifications and correlations to standard material-assessment tests for prediction of fire resistance in space. Research on smoke-particle changes in microgravity promises future improvements and increased sensitivity of smoke detectors in spacecraft. Research on fire suppression by extinguishing agents and venting can yield new information on effective control of the rare, but serious fire events in spacecraft.

Friedman, Robert↗

Passive dosimetry aboard the Mir Orbital Station: internal measurements

Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent. c2002 Elsevier Science Ltd. All rights reserved.

NASA Experiment Number 9401620↗

Evaluation of an Interferometric Sensor for In-Space Detection of Gas Leaks

Space mission planning often involves long-term storage of volatile liquids or high-pressure gases. These may include cryogenic fuels and oxidizers, high-pressure gases, and life-support-critical consumables. The risk associated with the storage of fluids and gases in space systems has long been an issue and the ability to retain these fluids is often tied to mission success. A leak in the storage or distribution system can cause many different problems, including a simple, but mission endangering, loss of inventory or, in severe cases, unbalanced thrust loads on a flight vehicle. Cryogenic propellants are especially difficult to store, especially over a long duration. The propellant can boil off and be lost through the insulating walls of the tank or simple thermal cycling of the fittings, valves, and propellant feed lines may unseat seals allowing the fluid to escape. Current NASA missions call for long-duration in-space storage of propellants, oxidizers, and life support supplies. Leaks of a scale detectable through a pressure drop in the storage tank are often catastrophic and have long been the focus of ground-based mitigation efforts where redundant systems are often employed. However, there is presently no technology available for detecting and monitoring low-level, but still mission-endangering, gas leaks in space. Standard in-space gas detection methods either have a very limited pressure range over which they operate effectively or are limited to certain gases. Mass spectrometer systems are able to perform the detection tasks, but their size, mass and use of high voltage, which could potentially lead to an arc that ignites a combustible propellent, severely limit their usefulness in a space system. In this paper, we present results from testing of the light-based interferometric gas monitoring and leak detection sensor shown in Fig. 1. The output of the sensor is an interference fringe pattern that is a function of the gas density, and commensurate index of refraction, in the sample region. Changes in the density of gas cause the interference fringes to move across a photodiode detector, providing a temporal history of the leak. The sensor is fiber coupled and constructed from solid optics, allowing for placement almost anywhere on the spacecraft. It is also advantageous in that it consumes very little power and does not introduce an ignition source. Data are presented demonstrating the capability of the sensor to measure density variations in different gas species. In addition, the transient response of the sensor in vacuum is demonstrated. These data extend and improve upon the results previously presented by the authors in Ref. [1].

Polzin, Kurt A.↗

Anisotropies of galactic cosmic rays outside the orbit of earth measured on Pioneer 10

Preliminary results of observations of the directional distribution of cosmic rays being conducted by the University of Chicago experiment on the Pioneer 10 spacecraft are presented. The unusual geometry of the directional scan is described and some features of the response of a bidirectional coincidence telescope are discussed. Selected periods free from the presence of low-energy solar particles exhibit transient deviations from uniform directional distributions for the bidirectional flux of nuclei greater than 67 MeV/nucleon. These deviations are typically 2 to 4 (plus or minus 1) percent and are oriented very roughly in a N-S direction. Such nonuniformities observed with a bidirectional detector can only be due to even order terms in the angular distribution function.

Lentz, G. A.↗

High dynamic range infrared radiometry and imaging

The use is described of cryogenically cooled, extrinsic silicon infrared detectors in an unconventional mode of operation which offers an unusually large dynamic range. The system performs intensity-to-frequency conversion at the focal plane via simple circuits with very low power consumption. The incident IR intensity controls the repetition rate of short duration output pulses over a pulse rate dynamic range of about 10(6). Theory indicates the possibility of monotonic and approx. linear response over the full dynamic range. A comparison between the theoretical and the experimental results shows that the model provides a reasonably good description of experimental data. Some measurements of survivability with a very intense IR source were made on these devices and found to be very encouraging. Evidence continues to indicate that some variations in interpulse time intervals are deterministic rather than probabilistic.

Coon, Darryl D.↗

256 x 256 PACE-1 PV HgCdTe focal plane arrays for medium and short wavelength infrared applications

The development of two 256 by 256 hybrid HgCdTe focal plane array (FPA) families is described, and their performance is discussed. The hybrid FPAs employ a PV HgCdTe detector array and custom Si CMOS readouts. The PACE-1 process was used to fabricate the detectors, whereby the liquid phase epitaxial growth of HgCdTe occurs on sapphire substrates buffered by a layer of CdTe. The performance characteristics of the detector arrays are given. A tactical 256 by 256 CMOS readout is tested, in which a high functional yield was achieved. Updated test results are given for a 256 by 256 readout circuit developed for use in an orbital replacement instrument for the Hubble Space Telescope. The characterizations of several MWIR and SWIR FPAs were thorough and shown to be reliable. The pixel yield, maximum FPA responsivity nonuniformity, and SWIR FPA read noise for the tests are given. The high contrast and insignificant fixed pattern noise of the imagery from the MWIR 256 by 256 FPA are emphasized. These qualities were obtained when the device was operating at 80 k and utilizing f/2 optics with an 8-in. focal length and a 4.4 micron high pass filter.

Kozlowski, L. J.↗

Tunnel effect measuring systems and particle detectors

Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

Kaiser, William J.↗