Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.

60 APPLIED LIFE SCIENCES↗

Feasibility study of a synchronized-moving-grid (SMOG) system to improve image quality in cone-beam computed tomography (CBCT)

Purpose: To evaluate the feasibility of a synchronized moving grid (SMOG) system to remove scatter artifacts, improve the contrast-to-noise ratio (CNR), and reduce image lag artifacts in cone-beam CT (CBCT). Methods: The SMOG system proposed here uses a rapidly oscillating, synchronized moving grid attached to the kV source. Multiple partial projections are taken at different grid positions to form a complete projection in each gantry position, before the gantry moves to the next position during a scan. The grid has a low transmission factor, and it is used for both scatter reduction and scatter measurement for postscan scatter correction. Experimental studies using a static grid and an enlarged CATphan phantom were performed to evaluate the potential CNR enhancement for different SMOG exposure numbers (1, 2, and 4). Simulation studies were performed to evaluate the image lag correction for different exposure numbers (2, 3, and 4) and grid interspace widths in SMOG using the data from an anthropomorphic pelvis phantom scan. Imaging dose of SMOG was also estimated by measuring the imaging dose in a CIRS CT dose phantom using a static grid. Results: SMOG can enhance the CNR by 16% and 13% when increasing exposure number from 1 to 2 and from 2 to 4, respectively. This enhancement was more dramatic for larger phantoms and smaller initial exposure numbers. Simulation results indicated that SMOG could reduce the lag to less than 4.3% for 2-exposure mode and to less than 0.8% for 3-exposure mode when the grid interspace width was 1.4 cm. Increasing the number of exposures in SMOG dramatically reduced the residual lag in the image. Reducing the grid interspace width somewhat reduced the residual lag. Skin line artifacts were removed entirely in SMOG. Point dose measurement showed that imaging dose of SMOG at isocenter was similar as that of a conventional CBCT. Conclusions: Compared to our previously developed static-grid dual-rotation method, the proposed SMOG technique has the advantages of enhancing the CNR, correcting the image lag, and reducing the delivery time. Once implemented, SMOG has the potential to remove scatter and image lag artifacts, and significantly enhance CNR for CBCT using the same scanning time as conventional CBCT.

60 APPLIED LIFE SCIENCES↗

Investigation of practical initial attenuation image estimates in TOF-MLAA reconstruction for PET/MR

Purpose: Time-of-flight joint attenuation and activity positron emission tomography reconstruction requires additional calibration (scale factors) or constraints during or post-reconstruction to produce a quantitative μ-map. In this work, the impact of various initializations of the joint reconstruction was investigated, and the initial average mu-value (IAM) method was introduced such that the forward-projection of the initial μ-map is already very close to that of the reference μ-map, thus reducing/minimizing the offset (scale factor) during the early iterations of the joint reconstruction. Consequently, the accuracy and efficiency of unconstrained joint reconstruction such as time-of-flight maximum likelihood estimation of attenuation and activity (TOF-MLAA) can be improved by the proposed IAM method. Methods: 2D simulations of brain and chest were used to evaluate TOF-MLAA with various initial estimates which include the object filled with water uniformly (conventional initial estimate), bone uniformly, the average μ-value uniformly (IAM magnitude initialization method), and the perfect spatial μ-distribution but with a wrong magnitude (initialization in terms of distribution). 3D GATE simulation was also performed for the chest phantom under a typical clinical scanning condition, and the simulated data were reconstructed with a fully corrected list-mode TOF-MLAA algorithm with various initial estimates. The accuracy of the average μ-values within the brain, chest, and abdomen regions obtained from the MR derived μ-maps was also evaluated using computed tomography μ-maps as the gold-standard. Results: The estimated μ-map with the initialization in terms of magnitude (i.e., average μ-value) was observed to reach the reference more quickly and naturally as compared to all other cases. Both 2D and 3D GATE simulations produced similar results, and it was observed that the proposed IAM approach can produce quantitative μ-map/emission when the corrections for physical effects such as scatter and randoms were included. The average μ-value obtained from MR derived μ-map was accurate within 5% with corrections for bone, fat, and uniform lungs. Conclusions: The proposed IAM-TOF-MLAA can produce quantitative μ-map without any calibration provided that there are sufficient counts in the measured data. For low count data, noise reduction and additional regularization/rescaling techniques need to be applied and investigated. The average μ-value within the object is prior information which can be extracted from MR and patient database, and it is feasible to obtain accurate average μ-value using MR derived μ-map with corrections as demonstrated in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Harmonic analysis for the characterization and correction of geometric distortion in MRI

Purpose: Magnetic resonance imaging (MRI) is gaining widespread use in radiation therapy planning, patient setup verification, and real-time guidance of radiation delivery. Successful implementation of these technologies relies on the development of simple and efficient methods to characterize and monitor the geometric distortions arising due to system imperfections and gradient nonlinearities. To this end, the authors present the theory and validation of a novel harmonic approach to the quantification of system-related distortions in MRI. Methods: The theory of spatial encoding in MRI is applied to demonstrate that the 3D distortion vector field (DVF) is given by the solution of a second-order boundary value problem (BVP). This BVP is comprised of Laplace’s equation and a limited measurement of the distortion on the boundary of a specified region of interest (ROI). An analytical series expansion solving this BVP within a spherical ROI is obtained, and a statistical uncertainty analysis is performed to determine how random errors in the boundary measurements propagate to the ROI interior. This series expansion is then evaluated to obtain volumetric DVF mappings that are compared to reference data obtained on a 3 T full-body scanner. This validation is performed within two spheres of 20 cm diameter (one centered at the scanner origin and the other offset +3 cm along each of the transverse directions). Initially, a high-order mapping requiring measurements at 5810 boundary points is used. Then, after exploring the impact of the boundary sampling density and the effect of series truncation, a reduced-order mapping requiring measurements at 302 boundary points is evaluated. Results: The volumetric DVF mappings obtained from the harmonic analysis are in good agreement with the reference data. Following distortion correction using the high-order mapping, the authors estimate a reduction in the mean distortion magnitude from 0.86 to 0.42 mm and from 0.93 to 0.39 mm within the central and offset ROIs, respectively. In addition, the fraction of points with a distortion magnitude greater than 1 mm is reduced from 35.6% to 2.8% and from 40.4% to 1.5%, respectively. Similarly, following correction using the reduced-order mapping, the mean distortion magnitude reduces to 0.45–0.42 mm within the central and offset ROIs, and the fraction of points with a distortion magnitude greater than 1 mm is reduced to 2.8% and 1.5%, respectively. Conclusions: A novel harmonic approach to the characterization of system-related distortions in MRI is presented. This method permits a complete and accurate mapping of the DVF within a specified ROI using a limited measurement of the distortion on the ROI boundary. This technique eliminates the requirement to exhaustively sample the DVF at a dense 3D array of points, thereby permitting the design of simple, inexpensive phantoms that may incorporate additional modules for auxiliary quality assurance objectives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Presentation of the MERC work-flow for the computation of a 2D radial reflector in a PWR

This paper presents a work-flow for computing an equivalent 2D radial reflector in a pressurized water reactor (PWR) core, in adequacy with a reference power distribution, computed with the method of characteristics (MOC) of the lattice code APOLLO2. The Multi-modelling Equivalent Reflector Computation (MERC) work-flow is a coherent association of the lattice code APOLLO2 and the core code COCAGNE, structured around the ADAO (Assimilation de Donnees et Aide a l'Optimisation) module of the SALOME platform, based on the data assimilation theory. This study leads to the computation of equivalent few-groups reflectors, that can be spatially heterogeneous, which have been compared to those obtained with the OPTEX similar methodology developed with the core code DONJON, as a first validation step. Subsequently, the MERC work-flow is used to compute the most accurate reflector in consistency with all the R and D choices made at Electricite de France (EDF) for the core modelling, in terms of number of energy groups and simplified transport solvers. We observe important reductions of the power discrepancies distribution over the core when using equivalent reflectors obtained with the MERC work-flow. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fast and accurate reduced-order modeling of a MOOSE-based additive manufacturing model with operator learning

One predominant challenge in additive manufacturing (AM) is to achieve specific material properties by manipulating manufacturing process parameters during the runtime. Such manipulation tends to increase the computational load imposed on existing simulation tools employed in AM. The goal of the present work is to construct a fast and accurate reduced-order model (ROM) for an AM model developed within the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, ultimately reducing the time/cost of AM control and optimization processes. Our adoption of the operator learning (OL) approach enabled us to learn a family of differential equations produced by altering process variables in the laser’s Gaussian point heat source. More specifically, we used the Fourier neural operator (FNO) and deep operator network (DeepONet) to develop ROMs for time-dependent responses. Furthermore, we benchmarked the performance of these OL methods against a conventional deep neural network (DNN)-based ROM. Ultimately, we found that OL methods offer comparable performance and, in terms of accuracy and generalizability, even outperform DNN at predicting scalar model responses. The DNN-based ROM afforded the fastest training time. Furthermore, all the ROMs were faster than the original MOOSE model yet still provided accurate predictions. FNO had a smaller mean prediction error than DeepONet, with a larger variance for time-dependent responses. Unlike DNN, both FNO and DeepONet were able to simulate time series data without the need for dimensionality reduction techniques. Finally, the present work can help facilitate the AM optimization process by enabling faster execution of simulation tools while still preserving evaluation accuracy.

36 MATERIALS SCIENCE↗

Mapping structural heterogeneity at the nanoscale with scanning nano-structure electron microscopy (SNEM)

Here, in this work, we explore the use of scanning electron diffraction (also known as 4D-STEM) coupled with electron atomic pair distribution function analysis (ePDF) to understand the local order (structure and chemistry) as a function of position in a complex multicomponent system, a hot rolled, Ni-encapsulated, Zr 65 Cu 17.5 Ni 10 Al 7.5 bulk metallic glass (BMG), with a spatial resolution of 3 nm. We show that it is possible to gain insight into the chemistry and chemical clustering/ordering tendency in different regions of the sample, including in the vicinity of nano-scale crystallites that are identified from virtual dark field images and in heavily deformed regions at the edge of the BMG. In addition to simpler analysis, unsupervised machine learning was used to extract partial PDFs from the material, modeled as a quasi-binary alloy, and map them in space. These maps allowed key insights not only into the local average composition, as validated by EELS, but also a unique insight into chemical short-range ordering tendencies in different regions of the sample during formation. The experiments are straightforward and rapid and, unlike spectroscopic measurements, don’t require energy filters on the instrument. We spatially map different quantities of interest (QoI’s), defined as scalars that can be computed directly from positions and widths of ePDF peaks or parameters refined from fits to the patterns. We developed a flexible and rapid data reduction and analysis software framework that allows experimenters to rapidly explore images of the sample on the basis of different QoI’s. The power and flexibility of this approach are explored and described in detail. Because of the fact that we are getting spatially resolved images of the nanoscale structure obtained from ePDFs we call this approach scanning nano-structure electron microscopy (SNEM), and we believe that it will be powerful and useful extension of current 4D-STEM methods.

36 MATERIALS SCIENCE↗

Data-driven models of nonautonomous systems

Nonautonomous dynamical systems are characterized by time-dependent inputs, which complicates the discovery of predictive models describing the spatiotemporal evolution of the state variables of quantities of interest from their temporal snapshots. When dynamic mode decomposition (DMD) is used to infer a linear model, this difficulty manifests itself in the need to approximate the time-dependent Koopman operators. Our approach is to approximate the original nonautonomous system with a modified system derived via a local parameterization of the time-dependent inputs. The modified system comprises a sequence of local parametric systems, which are subsequently approximated by a parametric surrogate model using the DRIPS (dimension reduction and interpolation in parameter space) framework. The offline step of DRIPS relies on DMD to build a linear surrogate model, endowed with reduced-order bases for the observables mapped from training data. The online step interpolates on suitable manifolds to construct a sequence of iterative parametric surrogate models; the target/test parameter points on these manifolds are specified by a local parameterization of the test time-dependent inputs. Here, we use numerical experimentation to demonstrate the robustness of our method and compare its performance with that of deep neural networks.

97 MATHEMATICS AND COMPUTING↗

Improving Thermal Model Prediction Through Statistical Analysis of Irradiation and Post-Irradiation Data from AGR Experiments

As part of the High Temperature Reactors (HTR) R&D program, a series of irradiation tests, designated as Advanced Gas-cooled Reactor (AGR), have been defined to support development and qualification of fuel design, fabrication process, and fuel performance under normal operation and accident conditions. The AGR tests employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule and instrumented with thermocouples (TC) embedded in graphite blocks enabling temperature control. While not possible to obtain by direct measurements in the tests, crucial fuel conditions (e.g., temperature, neutron fast fluence, and burnup) are calculated using core physics and thermal modeling codes. This paper is focused on AGR test fuel temperature predicted by the ABAQUS code's finite element-based thermal models. The work follows up on a previous study, in which several statistical analysis methods were adapted, implemented in the NGNP Data Management and Analysis System (NDMAS), and applied for qualification of AGR-1 thermocouple data. Abnormal trends in measured data revealed by the statistical analysis are traced to either measuring instrument deterioration or physical mechanisms in capsules that may have shifted the system thermal response. The main thrust of this work is to exploit the variety of data obtained in irradiation and post-irradiation examination (PIE) for assessment of modeling assumptions. As an example, the uneven reduction of the control gas gap in Capsule 5 found in the capsule metrology measurements in PIE helps identify mechanisms other than TC drift causing the decrease in TC readings. This suggests a more physics-based modification of the thermal model that leads to a better fit with experimental data, thus reducing model uncertainty and increasing confidence in the calculated fuel temperatures of the AGR-1 test.

99 GENERAL AND MISCELLANEOUS↗

TU-EF-204-10: A Preliminary Study Evaluating Calculation Variations of Local Noise Power Spectra for CT Simulation in Radiation Therapy

Purpose: Local noise power spectrum (NPS) properties are significantly affected by calculation variables and CT acquisition and reconstruction parameters, but a thoughtful analysis of these effects is absent. In this study, we performed a complete analysis of the effects of calculation and imaging parameters on the NPS. Methods: The uniformity module of a Catphan phantom was scanned with a Philips Brilliance 64-slice CT simulator using various scanning protocols. Images were reconstructed using both FBP and iDose4 reconstruction algorithms. From these images, local NPS were calculated for regions of interest (ROI) of varying locations and sizes, using four image background removal methods. Additionally, using a predetermined ground truth, NPS calculation accuracy for various calculation parameters was compared for computer simulated ROIs. A complete analysis of the effects of calculation, acquisition, and reconstruction parameters on the NPS was conducted. Results: The local NPS varied with ROI size and image background removal method, particularly at low spatial frequencies. The image subtraction method was the most accurate according to the computer simulation study, and was also the most effective at removing low frequency background components in the acquired data. However, first-order polynomial fitting using residual sum of squares and principle component analysis provided comparable accuracy under certain situations. Similar general trends were observed when comparing the NPS for FBP to that of iDose4 while varying other calculation and scanning parameters. However, while iDose4 reduces the noise magnitude compared to FBP, this reduction is spatial-frequency dependent, further affecting NPS variations at low spatial frequencies. Conclusion: The local NPS varies significantly depending on calculation parameters, image acquisition parameters, and reconstruction techniques. Appropriate local NPS calculation should be performed to capture spatial variations of noise; calculation methodology should be selected with consideration of image reconstruction effects and the desired purpose of CT simulation for radiotherapy tasks.

60 APPLIED LIFE SCIENCES↗

SU-C-207B-05: Tissue Segmentation of Computed Tomography Images Using a Random Forest Algorithm: A Feasibility Study

Purpose: Develop an automated Random Forest algorithm for tissue segmentation of CT examinations. Methods: Seven materials were classified for segmentation: background, lung/internal gas, fat, muscle, solid organ parenchyma, blood/contrast, and bone using Matlab and the Trainable Weka Segmentation (TWS) plugin of FIJI. The following classifier feature filters of TWS were investigated: minimum, maximum, mean, and variance each evaluated over a pixel radius of 2n, (n = 0–4). Also noise reduction and edge preserving filters, Gaussian, bilateral, Kuwahara, and anisotropic diffusion, were evaluated. The algorithm used 200 trees with 2 features per node. A training data set was established using an anonymized patient’s (male, 20 yr, 72 kg) chest-abdomen-pelvis CT examination. To establish segmentation ground truth, the training data were manually segmented using Eclipse planning software, and an intra-observer reproducibility test was conducted. Six additional patient data sets were segmented based on classifier data generated from the training data. Accuracy of segmentation was determined by calculating the Dice similarity coefficient (DSC) between manual and auto segmented images. Results: The optimized autosegmentation algorithm resulted in 16 features calculated using maximum, mean, variance, and Gaussian blur filters with kernel radii of 1, 2, and 4 pixels, in addition to the original CT number, and Kuwahara filter (linear kernel of 19 pixels). Ground truth had a DSC of 0.94 (range: 0.90–0.99) for adult and 0.92 (range: 0.85–0.99) for pediatric data sets across all seven segmentation classes. The automated algorithm produced segmentation with an average DSC of 0.85 ± 0.04 (range: 0.81–1.00) for the adult patients, and 0.86 ± 0.03 (range: 0.80–0.99) for the pediatric patients. Conclusion: The TWS Random Forest auto-segmentation algorithm was optimized for CT environment, and able to segment seven material classes over a range of body habitus and CT protocol parameters with an average DSC of 0.86 ± 0.04 (range: 0.80–0.99).

60 APPLIED LIFE SCIENCES↗

Estimation of Mass-Transport Overpotentials During Long-Term PEMFC Operation

A comprehensive method for separating cathode catalyst-layer and GDL mass-transport overpotentials was derived utilizing kinetic and Ohmic analysis of high-humidified H2/O2 and low-humidified H2/air polarization data. A hybridized method was applied accounting for electrochemical surface area (ECSA), hydrogen crossover, and exchange current density. This method delineates separate cathode GDL and electrode mass-transport overpotentials as a function of current density and operating time. The methodology is systematic and generalized and can be applied to polarization data from any type of durability test. The derivation was applied to periodic polarization data from a steady-state 1050-hour durability test and is shown to provide an accurate breakdown of the sources of performance losses. Increases in mass-transport overpotential for the cathode GDL and oxygen reduction reaction (ORR) overpotential were predominantly offset by improvements in the mass-transport overpotential of the cathode catalyst layer and reductions in the high-frequency resistance (HFR). Little increase in GDL mass-transport overpotential was observed during the first ~500 hour period, but a substantial increase was seen during the second ~500 hour period. The mass-transport overpotential of the cathode catalyst-layer was almost negligible at the end of ~1000 hours of operation, suggesting little O2 diffusion resistance through the ionomer and adjacent void volume.

08 HYDROGEN↗

Optimal Traffic Signal Control Using Priority Metric Based on Real-Time Measured Traffic Information

Optimizing traffic control systems at traffic intersections can reduce network-wide fuel consumption as well as improve traffic flow. While traffic signals have conventionally been controlled based on predetermined schedules, various adaptive control systems have been developed recently using advanced sensors such as cameras, radars, and LiDARs. By utilizing rich traffic information enabled by the advanced sensors, more efficient or optimal traffic signal control is possible in response to varying traffic conditions. This paper proposes an optimal traffic signal control method to minimize network-wide fuel consumption utilizing real-time traffic information provided by advanced sensors. This new method employs a priority metric calculated by a weighted sum of various factors, including the total number of vehicles, total vehicle speed, vehicle waiting time, and road preference. Genetic Algorithm (GA) is used as a global optimization method to determine the optimal weights in the priority metric. In order to evaluate the effectiveness of the proposed method, a traffic simulation model is developed in a high-fidelity traffic simulation environment called SUMO, based on a real-world traffic network. The traffic flow within this model is simulated using actual measured traffic data from the traffic network, enabling a comprehensive assessment of the novel optimal traffic signal control method in realistic conditions. The simulation results show that the proposed priority metric-based real-time traffic signal control algorithm can significantly reduce network-wide fuel consumption compared to the conventional fixed-time control and coordinated actuated control methods that are currently used in the modeled network. Additionally, incorporating truck priority in the priority metric leads to further improvements in fuel consumption reduction.

47 OTHER INSTRUMENTATION↗

SU-E-I-92: Is Photon Starvation Preventing Metal Artifact Reduction Algorithm From Working in KVCT?

Purpose: High density/high atomic number metallic objects create shading and streaking metal artifacts in the CT image that can cause inaccurate delineation of anatomical structures or inaccurate radiation dose calculation. A modified iterative maximum-likelihood polychromatic algorithm for CT (mIMPACT) that models the energy response of detectors, photon interaction processes and beam polychromaticity has successfully reduced metal artifacts in MVCT. Our extension of mIMPACT in kVCT did not significantly reduce metal artifacts for high density metal like steel. We hypothesize that photon starvation may result in the measured data in a commercial kVCT imaging beam. Methods: We measured attenuation of a range of steel plate thicknesses, sandwiched between two 12cm thick solid water blocks, using a Phillips Big Bore CTTM scanner in scout acquisition mode with 120kVp and 200mAs. The transmitted signal (y) was normalized to the air scan signal (y{sub 0}) to get attenuation [i.e., ln(y/y{sub 0})] data for a detector. Results: Below steel plate thickness of 13.4mm, the variations in measured attenuation as a function of view number are characterized by a quantum noise and show increased attenuation with metal thickness. On or above this thickness the attenuation shows discrete levels in addition to the quantum noise. Some views have saturated attenuation value. The histograms of the measured attenuation for up to 36.7mm of steel show this trend. The detector signal is so small that the quantization levels in the analog to digital (A-to-D) converter are visible, a clear indication of photon starvation. Conclusion: Photons reaching the kVCT detector after passing through a thick metal plate are either so low in number that the signal measured has large quantum noise, or are completely absorbed inside the plate creating photon starvation. This is un-interpretable by the mIMPACT algorithm and cannot reduce metal artifacts in kVCT for certain realistic thicknesses of steel hip implants. Moti Raj Paudel is supported by the Vanier Canada Graduate Scholarship, the Endowed Graduate Scholarship in Oncology and the Dissertation Fellowship at the University of Alberta. The authors acknowledge the CIHR operating grant number MOP 53254.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of high throughput screening methods to study dual-functional crosslinkable latexes

Herein, structure-formulation-property relationships for crosslinkable core-shell latexes were studied initially using high throughput screening methods and then using conventional experimental methods to determine optimum coating formulations. Two approaches that are used within coatings technology to improve sustainability are reduction in volatile organic compounds (VOC) and reduction in energy needed to cure coatings. Hybrid crosslinkable core-shell latexes have shown potential in meeting these challenges where film properties provided by particle coalescence are not sufficient and chemical crosslinking is needed. However, with numerous parameters involved such as latex particle architecture, nature and amount of crosslinker, and curing conditions, the screening of formulations via conventional coating testing methods becomes laborious and time-consuming. The results from high-throughput dye extraction and puncture testing were compared to data from conventional testing methods such as chemical resistance (MEK double rubs), pendulum hardness, and tensile testing to identify correlations. The dye extraction results have shown a strong correlation to solvent resistance and pendulum hardness data whereas toughness from puncture testing data correlated to tensile testing. Both high throughput dye extraction and puncture testing methods can be used for the accelerated screening of crosslinkable coating formulations to optimize curing parameters to achieve the best coating performance.

36 MATERIALS SCIENCE↗

Intelligent Computer Vision System for Automated Classification

In this paper we investigate an Intelligent Computer Vision System applied for recognition and classification of commercially available cork tiles. The system is capable of acquiring and processing gray images using several feature generation and analysis techniques. Its functionality includes image acquisition, feature extraction and preprocessing, and feature classification with neural networks (NN). We also discuss system test and validation results from the recognition and classification tasks. The system investigation also includes statistical feature processing (features number and dimensionality reduction techniques) and classifier design (NN architecture, target coding, learning complexity and performance, and training with our own metaheuristic optimization method). The NNs trained with our genetic low-discrepancy search method (GLPtauS) for global optimisation demonstrated very good generalisation abilities. In our view, the reported testing success rate of up to 95% is due to several factors: combination of feature generation techniques; application of Analysis of Variance (ANOVA) and Principal Component Analysis (PCA), which appeared to be very efficient for preprocessing the data; and use of suitable NN design and learning method.

97 MATHEMATICS AND COMPUTING↗

Time-of-flight neutron total scattering with applied electric fields: Ex situ and in situ studies of ferroelectric materials

Characterizing the structural response of functional materials (e.g., piezoelectrics and ferroelectrics) to electric fields is key for the creation of structure-property relationships. Here in this paper, we present a new sample environment and data reduction routines which allow the measurement of time-of-flight neutron total scattering during the in situ or ex situ application of high voltage (<10 kV) to a sample. Instead of utilizing the entire detector space of the diffractometer, only selected regions of detector pixels with scattering at the desired angle to the sample electric field are interrogated, which allows the generation of orientation-dependent reciprocal space patterns and real-space pair distribution functions (PDFs). We demonstrate the method using the relaxor ferroelectric Na 1/2 Bi 1/2 TiO 3 and observe lattice expansion parallel and contraction perpendicular to the electric field for both in situ or ex situ experiments, revealing the irreversible nature of the local scale structural changes to this composition. Additionally, changes in the distributions of nearest neighbor metal-oxygen bond lengths are observed, which have been difficult to observe in previously measured analogous orientation-dependent X-ray PDFs. Lastly, considerations related to sample positioning and background subtraction are discussed, and future research directions are suggested.

36 MATERIALS SCIENCE↗

Robust error calibration for serial crystallography

Serial crystallography is an important technique with unique abilities to resolve enzymatic transition states, minimize radiation damage to sensitive metalloenzymes and perform de novo structure determination from micrometre-sized crystals. This technique requires the merging of data from thousands of crystals, making manual identification of errant crystals unfeasible. cctbx.xfel.merge uses filtering to remove problematic data. However, this process is imperfect, and data reduction must be robust to outliers. We add robustness to cctbx.xfel.merge at the step of uncertainty determination for reflection intensities. This step is a critical point for robustness because it is the first step where the data sets are considered as a whole, as opposed to individual lattices. Robustness is conferred by reformulating the error-calibration procedure to have fewer and less stringent statistical assumptions and incorporating the ability to down-weight low-quality lattices. We then apply this method to five macromolecular XFEL data sets and observe the improvements to each. The appropriateness of the intensity uncertainties is demonstrated through internal consistency. This is performed through theoretical CC 1/2 and I /σ relationships and by weighted second moments, which use Wilson's prior to connect intensity uncertainties with their expected distribution. This work presents new mathematical tools to analyze intensity statistics and demonstrates their effectiveness through the often underappreciated process of uncertainty analysis.

Mittan-Moreau, David W.↗