Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Determining Utility System Value of Demand Flexibility From Grid-interactive Efficient Buildings

This report focuses on ways current methods and practices that establish the value to electric utility systems of distributed energy resource (DER) investments can be enhanced to determine the value of demand flexibility in grid-interactive efficient buildings that can provide grid services. The report introduces key valuation concepts that are applicable to demand flexibility that these buildings can provide and links to other documents that describe these concepts and their implementation in more detail.The scope of this report is limited to the valuation of economic benefits to the utility system. These are the foundational values on which other benefits (and costs) can be built. Establishing the economic value to the grid of demand flexibility provides the information needed to design programs, market rules, and rates that align the economic interest of utility customers with building owners and occupants. By nature, DERs directly impact customers and provide societal benefits external to the utility system. Jurisdictions can use utility system benefits and costs as the foundation of their economic analysis but align their primary cost-effectiveness metric with all applicable policy objectives, which may include customer and societal (non-utility system) impacts.This report suggests enhancements to current methods and practices that state and local policymakers, public utility commissions, state energy offices, utilities, state utility consumer representatives, and other stakeholders might support. These enhancements can improve the consistency and robustness of economic valuation of demand flexibility for grid services. The report concludes with a discussion of considerations for prioritizing implementation of these improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable Thermal Energy Systems: Systemic Challenges and Transformational Policies (Report 2)

Two important challenges for RTES are the need for significant further innovation and deployment, particularly in the United States. In the face of continued success of other renewable energy technologies, such as solar photovoltaics (PV) and land-based wind energy for electricity, it is worthwhile to evaluate the current state of select RTES technologies in the context of technology innovation systems and energy transitions. This report marks a departure from the existing body of research we are aware of and have contributed to relating to RTES applications for industrial process heat in the United States. Our objectives for this report are fourfold: 1) Begin considering the challenges of RTES deployment in the United States through application of socio-technical and transitions frameworks; 2) Begin applying the theory of RTES as configurational technology innovation systems in the United States and for industrial process heat specifically; 3) Review RTES innovation, policies, and market formation activities in the contexts of Objectives 1 and 2; 4) Identify future paths for RTES research. Ultimately, the challenges associated with scaling the deployment of RTES in the United States are related to the need to develop a well-functioning innovation system that can overcome resistance from a highly stable socio-technical regime within a shrinking window of time to address the climate crisis, U.S. industrial competitiveness, and volatile energy commodity price shocks. Current efforts toward scaling for RTES applications in industry and buildings emphasize the need for further cost reductions, but not for interventions that support actors and their interactions and that increase the legitimacy of the technologies. As a result, there are significant opportunities to analyze the social contexts of RTES that can then be used to inform the design of effective, transformational policy portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Dawn of Geostationary Air Quality Monitoring: Case Studies from Seoul and Los Angeles

With the near-future launch of geostationary pollution monitoring satellite instruments over North America, East Asia, and Europe, the air quality community is preparing for an integrated global atmospheric composition observing system at unprecedented spatial and temporal resolutions. One of the ways that NASA has supported this community preparation is through demonstration of future space-borne capabilities using the Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) airborne instrument. This paper integrates repeated high-resolution maps from GeoTASO, ground-based Pandora spectrometers, and low Earth orbit measurements from the Ozone Mapping and Profiler Suite (OMPS), for case studies over two metropolitan areas: Seoul, South Korea on June 9, 2016 and Los Angeles, California on June 27, 2017. This dataset provides a unique opportunity to illustrate how geostationary air quality monitoring platforms and ground-based remote sensing networks will close the current spatiotemporal observation gap. GeoTASO observes large differences in diurnal behavior between these urban areas, with NO2 accumulating within the Seoul Metropolitan Area through the day but NO2 peaking in the morning and decreasing throughout the afternoon in the Los Angeles Basin. In both areas, the earliest morning maps exhibit spatial patterns similar to emission source areas (e.g., urbanized valleys, roadways, major airports). These spatial patterns change later in the day due to boundary layer dynamics, horizontal transport, and chemistry. The nominal resolution of GeoTASO is finer than will be obtained from geostationary platforms, but when NO2 data over Los Angeles are up-scaled to the expected resolution of TEMPO, spatial features discussed are conserved. Pandora instruments installed in both metropolitan areas capture the diurnal patterns observed by GeoTASO, continuously and over longer time periods, and will play a critical role in validation of the next generation of satellite measurement. These case studies demonstrate that different regions can have diverse diurnal patterns and that day-to-day variability due to meteorology or anthropogenic patterns such as weekday/weekend variations in emissions is large. Low Earth orbit measurements, despite their inability to capture the diurnal patterns at fine spatial resolution, will be essential for intercalibrating the geostationary radiances and cross-validating the geostationary retrievals in an integrated global observing system.

Geostationary↗

Using Calibrated Water Data for Preliminary Validation of the SRT Code for Advanced Reactors

Recent interest and corresponding progress worldwide regarding advanced nuclear reactors has renewed focus on their performance and related safety assessments. Specifically, the U.S. Nuclear Regulatory Commission has emphasized the importance of mechanistic approaches to source term analysis for advanced reactor licensing applications, which attempt to realistically account radionuclide transport and retention phenomena. Further model development is required due to the numerous and complex physical and chemical phenomena associated with mechanistic source term analyses. Reflecting the need for modeling advancement, Argonne National Laboratory developed a mechanistic source term analysis tool for sodium fast reactors. The Simplified Radionuclide Transport (SRT) code describes fuel pin failure (for simulating the initial condition at the point of fuel pin breach), bubble scrubbing, deposition, leakage and following environmental impact. In the current work, a validation study of the SRT bubble scrubbing model is performed using a water-loop experiment performed at the University of Wisconsin-Madison. Through the analysis, the approach and fundamental bubble scrubbing models in SRT, which examine the removal of aerosols within the bubble as it is transported through a pool, have been widely evaluated. The results of the assessment demonstrate a high level of agreement in the regions of greater aerosol size. In the parameter range of minimal aerosol removal, the simulation slightly underpredicts the experiment results; however, considering the scale of plots and huge uncertainties inherently included, the deviation can be judged to be minor and would produce a conservative result. In addition, uncertainty analysis has been further refined to reflect the experimental distribution of parameters including aerosol sizes, which induces a span of performance for each representative aerosol size. Based upon the initial validation results along with uncertainty effects, SRT is expected to provide meaningful insights for the analysis of bubble scrubbing. Future sodium-loop tests will provide further validation basis.

Kam, Dong Hoon↗

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preprocessing for Unintended Conducted Emissions Classification with ResNet

Characterization of Unintended Conducted Emissions (UCE) from electronic devices is important when diagnosing electromagnetic interference, performing nonintrusive load monitoring (NILM) of power systems, and monitoring electronic device health, among other applications. Prior work has demonstrated that UCE analysis can serve as a diagnostic tool for energy efficiency investigations and detailed load analysis. While explaining the feature selection of deep networks with certainty is often not fully comprehensive, or in other applications, quite lacking, additional tools/methods for further corroboration and confirmation can help further the understanding of the researcher. This is true especially in the subject application of the study in this paper. Often the focus of such efforts is the selected features themselves, and there is not as much understanding gained about the noise in the collected data. If selected feature and noise characteristics are known, it can be used to further shape the design of the deep network or associated preprocessing. This is additionally difficult when the available data are limited, as in the case which the authors investigated in this study. Here, the authors present a novel work (which is a proposed complementary portion of the overall solution to the deep network classification explainability problem for this application) by applying a systematic progression of preprocessing and a deep neural network (ResNet architecture) to classify UCE data obtained via current transformers. By using a methodical application of preprocessing techniques prior to a deep classifier, hypotheses can be produced concerning what features the deep network deems important relative to what it perceives as noise. For instance, it is hypothesized in this particular study as a result of execution of the proposed method and periodic inspection of the classifier output that the UCE spectral features are relatively close to each other or to the interferers, as systematically reducing the beta parameter of the Kaiser window produced progressively better classification performance, but only to a point, as going below the Beta of eight produced decreased classifier performance, as well as the hypothesis that further spectral feature resolution was not as important to the classifier as rejection of the leakage from a spectrally distant interference. This can be very important in unpredictable low-FNR applications, where knowing the difference between features and noise is difficult. As a side-benefit, much was learned regarding the best preprocessing to use with the selected deep network for the UCE collected from these low power consumer devices obtained via current transformers. Baseline rectangular windowed FFT preprocessing provided a 62% classification increase versus using raw samples. After performing a more optimal preprocessing, more than 90% classification accuracy was achieved across 18 low-power consumer devices for scenarios in which the in-band features-to-noise ratio (FNR) was very poor.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Potential for Improved Lubricants to Reduce Wind O&M Costs

Lubrication is a key aspect of maintaining a wind turbine in operational condition. In this study, we quantify the potential for increasing energy production and reducing maintenance costs across the current and future U.S. fleet of wind turbines as a result of improvements in lubrication performance. The modeled improvements reduce the median levelized cost of energy by 1-2% across the U.S. fleet. Extending the lubricant replacement interval has a larger impact on total cost and energy production than reducing lubricant cost.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Architecture of Pseudomonas aeruginosa glutamyl-tRNA synthetase defines a subfamily of dimeric class Ib aminoacyl-tRNA synthetases

The aminoacyl-tRNA synthetases (AaRSs) are an ancient family of structurally diverse enzymes that are divided into two major classes. The functionalities of most AaRSs are inextricably linked to their oligomeric states. While GluRSs were previously classified as monomers, the current investigation reveals that the form expressed in Pseudomonas aeruginosa is a rotationally pseudosymmetrical homodimer featuring intersubunit tRNA binding sites. Both subunits display a highly bent, "pipe strap" conformation, with the anticodon binding domain directed toward the active site. The tRNA binding sites are similar in shape to those of the monomeric GluRSs, but are formed through an approximately 180-degree rotation of the anticodon binding domains and dimerization via the anticodon and D-arm binding domains. As a result, each anticodon binding domain is poised to recognize the anticodon loop of a tRNA bound to the adjacent protomer. Additionally, the anticodon binding domain has an α-helical C-terminal extension containing a conserved lysine-rich consensus motif positioned near the predicted location of the acceptor arm, suggesting dual functions in tRNA recognition. The unique architecture of PaGluRS broadens the structural diversity of the GluRS family, and member synthetases of all bacterial AaRS subclasses have now been identified that exhibit oligomerization.

Fenwick, Michael K↗

Current and Future Developments in Air Traffic Control

Current and future energy demands, end uses, and cost used to characterize typical applications services in the industrial sector of the United States are examined. A review and evaluation of existing industrial energy data bases was undertaken to assess their potential for supporting SERI research market suitability analysis; (2) market development; (3) end use matching; (4) industrial application studies; and (5) identification of cost and performance goals for solar systems and typical information requirements for industrial energy end use. The focus was on fuels and electric energy used for heat and power purchased by the manufacturing subsector and listed by 2, 3, and 4 digit SIC, primary fuel. The effects of federal and state industrial energy conservation programs on future industrial sector demands were assessed.

Jackson, Joseph↗

Circulating miRNA Signature Predicts Health Risks Associated with Cancer and Spaceflight

Biological risks associated with space radiation and microgravity are major concerns for long-term space travel. Through a Systems Biology approach, our previous NASA work has shown both TGF signaling pathways and miRNAs have a critical impact on defining health risks with and without space irradiation. We hypothesize that circulating microRNA (miRNA) signatures are driving microvascular disease and muscle degeneration associated with accelerating aging and will be enhanced by exposure to the space environment (radiation and microgravity). We are investigating this hypothesis with both in vivo and in vitro models to test novel antagonist therapies to these miRNA signatures as countermeasures to reduce space radiation-induced health risks. A comprehensive Systems Biology approach is utilized to examine the influence by high atomic number by high (H) atomic number (Z) and energy (E) (HZE) irradiation. To simulate low-dose exposure due to galactic cosmic rays (GCR), we used ions, energy, and doses determined by a NASA consensus formula of 7 different ions to represent GCR (referred to as GCR sim model). To similate high-dose radiation exposure due to solar particle events (SPE), we used a solar particle event (SPE) sim model which gave a total dose of 1Gy protons with energy ranges from 50MeV to 150MeV. C57BL/6 wild-type female mice were utilized for the irradiations with our established simulated microgravity model (hindlimb suspension model) and an in vitro 3D microvasculature tissue model under simulated microgravity (clinostat) conditions was also irradiated. To expand on the circulating miRNA signature determined from our preliminary data, we determined a group of conserved miRNAs which are commonly being regulated in the majority of the organs and tissues throughout the host using our established techniques. MiRNA-sequencing was done on serum (at time of sacrifice), liver, heart, and muscle (soleus muscle) tissue for all radiation groups. Additional validation of the key miRNAs was performed by droplet digital PCR (ddPCR). This revealed a key circulating miRNA signature (consisting of multiple miRNAs) impacting cardiovascular and muscular disease risk. Further in vitro experiments with CRISPR/Cas9 system to knockout the key miRNA signatures, novel self-delivering antagomirs, overexpression of the miRNAs test the functional impact of the miRNA signatures on both microvascular disease and muscle degeneration due to space irradiation. The current work has started to allow the possible development of a novel minimally invasive miRNA based radioprotector to be used as a countermeasure for space radiation. Collectively, understanding of how whole body space radiation impacts microvascular and tissue degeneration through circulating miRNAs will greatly enhance health risk prognostication and provide possible new mechanisms for protection against space radiation. This work is supported by the Translational Research Institute through NASA Cooperative Agreement NNX16AO69A (T-0404) awarded to AB.

Beheshti, Afshin↗

Commuter preferences for a first-mile/last-mile microtransit service in the United States

Transportation system models rely heavily upon value of time (VOT) estimates to predict customer behavior. Accurate VOT estimates are particularly vital for planning new services such as on-demand ride hailing or microtransit because customers’ sensitivity to wait time, walk time, and route detour time affects their likelihood of selecting these modes. If an incorrect VOT is assumed during service planning, then ridership will be depressed because of a mismatch between their preferences and how the system is designed. In this paper, we report on the measurement of VOT for microtransit, a shared first-mile/last-mile mobility service, obtained using stated preference microdata from four U.S. cities. Here, we found a median in-vehicle VOT for microtransit of $\$$18.63 (95% CI: $\$$13.39–$\$$24.46) and an access VOT of $\$$75.38 (95% CI: $\$$59.22–$\$$94.96). The former is practically equal to the VOT we found for respondents’ current modes ($\$$20.24, 95% CI: $\$$13.71–$\$$26.94). We also found that men, younger riders, the highly educated, and transit riders are more likely to be interested in microtransit. Since the disutility of time spent on microtransit is not higher than that of other modes, we believe this new service has the potential to attract riders, and particularly if the system is designed with low waiting and walking times.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

1994 Cleveland Area Home Interview Travel Survey

The Greater Cleveland Regional Transit Authority and the Northeast Ohio Areawide Coordinating Agency conducted a home-interview travel survey to update information on current travel patterns and trip characteristics in the northeast Ohio area. The survey was administered during the spring of 1994 to 1,651 households, and 17,101 trips were recorded. The survey included 1,056 households from Cuyahoga County. Participants were assigned a travel day (Monday through Friday only) and mailed a household survey form and travel diaries for each household member five years old or older.

1Hz data↗

Smart Building Start (SBS) (CRADA 480)

The idea of Smart Building Start (SBS) is to manage the on/off scheduling of HVAC equipment in buildings in an optimal way in order to achieve comfort conditions at the designated times with the minimal use of energy. This concept is also known as Optimal Start and it has typically been used in buildings to start up equipment based on predictions made for a representative (or average) zone in a building. This means that zones that could have waited longer to receive conditioned air are activated too early leading to unnecessary energy loss. The approach proposed in this project is to develop and implement a distributed version of optimal start that will consider the individual requirements of all treated zones. The developed control strategy will enable smart start of the central plant as well as further localized control over each individual zone by means of setpoint adjustment so that zones are not conditioned too early thereby reducing energy use compared to the current state of the art. This project is a collaboration between PNNL and Verdicity with the goal being to bring the research concept of SBS to commercialization. The SBS algorithm(s) will be implemented and hosted on the PNNL-developed open-platform VOLTTRON which will accelerate bringing the research to practice. It is anticipated that this project will lead to new IP surrounding the algorithm and its decentralized deployment. The project will also further demonstrate the success of VOLTRON as a flexible platform for implementation of innovative algorithms for improving energy efficiency in buildings. Previous studies on smart building start carried out by PNNL have indicated potential energy savings on the order of 10-15% for multi-zone buildings compared to conventional strategies. Verdicity currently has a number of customers who can benefit from the use of this technology. PNNL will work with Verdicity to identify any key gaps in the integrated software and jointly work to enhance and customize it for Verdicity and to integrate it with their existing products for use at their customers’ sites. The proposed work will help previously funded Federal research and development technology investments find their way into a viable commercial market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Distinctive Evolution of orfX Clostridium parabotulinum Strains and Their Botulinum Neurotoxin Type A and F Gene Clusters Is Influenced by Environmental Factors and Gene Interactions via Mobile Genetic Elements

Of the seven currently known botulinum neurotoxin-producing species of Clostridium, C. parabotulinum, or C. botulinum Group I, is the species associated with the majority of human botulism cases worldwide. Phylogenetic analysis of these bacteria reveals a diverse species with multiple genomic clades. The neurotoxins they produce are also diverse, with over 20 subtypes currently represented. The existence of different bont genes within very similar genomes and of the same bont genes/gene clusters within different bacterial variants/species indicates that they have evolved independently. The neurotoxin genes are associated with one of two toxin gene cluster types containing either hemagglutinin (ha) genes or orfX genes. These genes may be located within the chromosome or extrachromosomal elements such as large plasmids. Although BoNT-producing C parabotulinum bacteria are distributed globally, they are more ubiquitous in certain specific geographic regions. Notably, northern hemisphere strains primarily contain ha gene clusters while southern hemisphere strains have a preponderance of orfX gene clusters. OrfX C. parabotulinum strains constitute a subset of this species that contain highly conserved bont gene clusters having a diverse range of bont genes. While much has been written about strains with ha gene clusters, less attention has been devoted to those with orfX gene clusters. The recent sequencing of 28 orfX C. parabotulinum strains and the availability of an additional 91 strains for analysis provides an opportunity to compare genomic relationships and identify unique toxin gene cluster characteristics and locations within this species subset in depth. The mechanisms behind the independent processes of bacteria evolution and generation of toxin diversity are explored through the examination of bacterial relationships relating to source locations and evidence of horizontal transfer of genetic material among different bacterial variants, particularly concerning bont gene clusters. Analysis of the content and locations of the bont gene clusters offers insights into common mechanisms of genetic transfer, chromosomal integration, and development of diversity among these genes.

59 BASIC BIOLOGICAL SCIENCES↗

Synchronous clock stopper for microprocessor

A synchronous clock stopper circuit for inhibiting clock pulses to a microprocessor in response to a stop request signal, and for reinstating the clock pulses in response to a start request signal thereby to conserve power consumption of the microprocessor when used in an environment of limited power. The stopping and starting of the microprocessor is synchronized, by a phase tracker, with the occurrences of a predetermined phase in the instruction cycle of the microprocessor in which the I/O data and address lines of the microprocessor are of high impedance so that a shared memory connected to the I/O lines may be accessed by other peripheral devices. The starting and stopping occur when the microprocessor initiates and completes, respectively, an instruction, as well as before and after transferring data with a memory. Also, the phase tracker transmits phase information signals over a bus to other peripheral devices which signals identify the current operational phase of the microprocessor.

Kitchin, David A.↗

Multifunctional Cooling Garment for Space Suit Environmental Control

Future manned space exploration missions will require space suits with capabilities beyond the current state of the art. Portable Life Support Systems for these future space suits face daunting challenges, since they must maintain healthy and comfortable conditions inside the suit for longduration missions while minimizing weight and water venting. We have demonstrated the feasibility of an innovative, multipurpose garment for thermal and humidity control inside a space suit pressure garment that is simple, rugged, compact, and lightweight. The garment is a based on a conventional liquid cooling and ventilation garment (LCVG) that has been modified to directly absorb latent heat as well as sensible heat. This hybrid garment will prevent buildup of condensation inside the pressure garment, prevent loss of water by absorption in regenerable CO2 removal beds, and conserve water through use of advanced lithium chloride absorber/radiator (LCAR) technology for nonventing heat rejection. We have shown the feasibility of this approach by sizing the critical components for the hybrid garment, developing fabrication methods, building and testing a proof-of-concept system, and demonstrating by test that its performance is suitable for use in space suit life support systems.

Izenson, Michael G.↗

Runtime Assurance Protection for Advanced Turbofan Engine Control

This paper describes technical progress made in the application of run time assurance (RTA) methods to turbofan engines with advanced propulsion control algorithms that are employed to improve engine performance. It is assumed that the advanced algorithms cannot be fully certified using current verification and validation approaches and therefore need to be continually monitored by an RTA system that ensures safe operation. However, current turbofan engine control systems utilize engine protection logic for safe combustion dynamics and stable airflow through the engine. It was determined that the engine protection logic should continue to be used to provide system safety and should be considered as a part of the overall RTA system. The additional function that an RTA system provides is to perform diagnostics on anomalous conditions to determine if these conditions are being caused by errors in the advanced controller. If this is the case, the RTA system switches operation to a trusted reversionary controller. Initial studies were performed to demonstrate this benefit. The other focus was to improve the performance of the engine protection logic, which was deemed too conservative and reduced engine performance during transient operations. It was determined that the conservative response was due to poor tuning of one of the controller channels within the protection logic. An automatic tuning algorithm was implemented to optimize the protection logic control gains based on minimizing tracking error. Improved tracking responses were observed with no change to the existing protection logic control architecture.

runtime monitoring↗