Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Corrective Action Investigation Plan for Corrective Action Unit 414: Clean Slate III Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 1

Corrective Action Unit (CAU) 414 is located on the Tonopah Test Range, which is approximately 130 miles northwest of Las Vegas, Nevada, and approximately 40 miles southeast of Tonopah, Nevada. The CAU 414 site consists of the release of radionuclides to the surface and shallow subsurface from the conduct of the Clean Slate III (CSIII) storage–transportation test conducted on June 9, 1963. CAU 414 includes one corrective action site (CAS), TA-23-03CS (Pu Contaminated Soil). The known releases at CAU 414 are the result of the atmospheric dispersal of contamination from the 1963 CSIII test. The CSIII test was a nonnuclear detonation of a nuclear device located inside a reinforced concrete bunker covered with 8 feet of soil. This test dispersed radionuclides, primarily uranium and plutonium, on the ground surface. The presence and nature of contamination at CAU 414 will be evaluated based on information collected from a corrective action investigation (CAI). The investigation is based on the data quality objectives (DQOs) developed on June 7, 2016, by representatives of the Nevada Division of Environmental Protection; the U.S. Air Force; and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective action alternatives for CAU 414.

54 ENVIRONMENTAL SCIENCES↗

Avoiding erroneous analysis of MIM diode current-voltage characteristics through exponential fitting

Accurate fitting of measured current-voltage [$I$ ($V$) ] data is crucial to the correct analysis and understanding of metal-insulator–metal (MIM) diodes, especially for optical rectennas. With the commonly used polynomial fitting of the $I$$(V)$ data, the order of the fit can drastically affect the diode performance metrics such as resistance, responsivity, and asymmetry. Additionally, the resulting fitting coefficients provide no useful parameters. An exponential-based equation can fit the $I$$(V)$ data well, can avoid artifacts from the choice of order of the polynomial, and allows for the accurate calculation of diode performance metrics directly from the fitting coefficients. Finally, connecting the performance metrics to fitting coefficients shows a correspondence between zero-bias responsivity and asymmetry at any given voltage.

42 ENGINEERING↗

SU-E-T-226: Correction of a Standard Model-Based Dose Calculator Using Measurement Data

Purpose: To propose a hybrid method that combines advantages of the model-based and measurement-based method for independent dose calculation. Modeled-based dose calculation, such as collapsed-cone-convolution/superposition (CCCS) or the Monte-Carlo method, models dose deposition in the patient body accurately; however, due to lack of detail knowledge about the linear accelerator (LINAC) head, commissioning for an arbitrary machine is tedious and challenging in case of hardware changes. On the contrary, the measurement-based method characterizes the beam property accurately but lacks the capability of dose disposition modeling in heterogeneous media. Methods: We used a standard CCCS calculator, which is commissioned by published data, as the standard model calculator. For a given machine, water phantom measurements were acquired. A set of dose distributions were also calculated using the CCCS for the same setup. The difference between the measurements and the CCCS results were tabulated and used as the commissioning data for a measurement based calculator. Here we used a direct-ray-tracing calculator (ΔDRT). The proposed independent dose calculation consists of the following steps: 1. calculate D-model using CCCS. 2. calculate D-ΔDRT using ΔDRT. 3. combine Results: D=D-model+D-ΔDRT. Results: The hybrid dose calculation was tested on digital phantoms and patient CT data for standard fields and IMRT plan. The results were compared to dose calculated by the treatment planning system (TPS). The agreement of the hybrid and the TPS was within 3%, 3 mm for over 98% of the volume for phantom studies and lung patients. Conclusion: The proposed hybrid method uses the same commissioning data as those for the measurement-based method and can be easily extended to any non-standard LINAC. The results met the accuracy, independence, and simple commissioning criteria for an independent dose calculator.

60 APPLIED LIFE SCIENCES↗

Complete Monte Carlo Simulation of Neutron Scattering Experiments

In the far past, it was not possible to accurately correct for the finite geometry and the finite sample size of a neutron scattering set-up. The limited calculation power of the ancient computers as well as the lack of powerful Monte Carlo codes and the limitation in the data base available then prevented a complete simulation of the actual experiment. Using e.g. the Monte Carlo neutron transport code MCNPX [1], neutron scattering experiments can be simulated almost completely with a high degree of precision using a modern PC, which has a computing power that is ten thousand times that of a super computer of the early 1970s. Thus, (better) corrections can also be obtained easily for previous published data provided that these experiments are sufficiently well documented. Better knowledge of reference data (e.g. atomic mass, relativistic correction, and monitor cross sections) further contributes to data improvement. Elastic neutron scattering experiments from liquid samples of the helium isotopes performed around 1970 at LANL happen to be very well documented. Considering that the cryogenic targets are expensive and complicated, it is certainly worthwhile to improve these data by correcting them using this comparatively straightforward method. As two thirds of all differential scattering cross section data of {sup 3}He(n,n){sup 3}He are connected to the LANL data, it became necessary to correct the dependent data measured in Karlsruhe, Germany, as well. A thorough simulation of both the LANL experiments and the Karlsruhe experiment is presented, starting from the neutron production, followed by the interaction in the air, the interaction with the cryostat structure, and finally the scattering medium itself. In addition, scattering from the hydrogen reference sample was simulated. For the LANL data, the multiple scattering corrections are smaller by a factor of five at least, making this work relevant. Even more important are the corrections to the Karlsruhe data due to the inclusion of the missing outgoing self-attenuation that amounts to up to 15%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System and method for generating motion corrected tomographic images

A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.

47 OTHER INSTRUMENTATION↗

Toward an understanding of foreground emission in the BICEP2 region

BICEP2 has reported the detection of a degree-scale B-mode polarization pattern in the Cosmic Microwave Background (CMB) and has interpreted the measurement as evidence for primordial gravitational waves. Motivated by the profound importance of the discovery of gravitational waves from the early Universe, we examine to what extent a combination of Galactic foregrounds and lensed E-modes could be responsible for the signal. We reanalyze the BICEP2 results and show that the 100 ×150 GHz and 150 ×150 GHz data are consistent with a cosmology with r=0.2 and negligible foregrounds, but also with a cosmology with r=0 and a significant dust polarization signal. We give independent estimates of the dust polarization signal in the BICEP2 region using a number of different approaches: (1) data-driven models based on Planck 353 GHz intensity, polarization fractions inferred from the same Planck data used by the BICEP2 team but corrected for CMB and CIB contributions, and polarization angles from starlight polarization data or the Planck sky model; (2) the same set of pre-Planck models used by the BICEP2 team but taking into account the higher polarization fractions observed in the CMB- and CIB-corrected map; (3) a measurement of neutral hydrogen gas column density N{sub HI} in the BICEP2 region combined with an extrapolation of a relation between HI column density and dust polarization derived by Planck; and (4) a dust polarization map based on digitized Planck data, which we only use as a final cross-check. While these approaches are consistent with each other, the expected amplitude of the dust polarization power spectrum remains uncertain by about a factor of three. The lower end of the prediction leaves room for a primordial contribution, but at the higher end the dust in combination with the standard CMB lensing signal could account for the BICEP2 observations, without requiring the existence of primordial gravitational waves. By measuring the cross-correlations between the pre-Planck templates used in the BICEP2 analysis and between different versions of a data-based template, we emphasize that cross-correlations between models are very sensitive to noise in the polarization angles and that measured cross-correlations are likely underestimates of the contribution of foregrounds to the map. These results suggest that BICEP1 and BICEP2 data alone cannot distinguish between foregrounds and a primordial gravitational wave signal, and that future Keck Array observations at 100 GHz and Planck observations at higher frequencies will be crucial to determine whether the signal is of primordial origin.

79 ASTRONOMY AND ASTROPHYSICS↗

6 GeV Parity Violating Deep Inelastic Scattering at Jefferson Laboratory

The 6 GeV Parity Violating Deep Inelastic Scattering (PVDIS) experiment has measured a 10{sup -4} level asymmetry through polarized electron scattering off a liquid deuterium target with a beam energy of 6 GeV. This experiment has a goal of measuring a combination of the product of the weak neutral couplings of the electron and the quark with a factor of six improvement in precision over world data. Precise data for the couplings are essential to search for physics beyond the Standard Model. The experiment took place in Hall A at Thomas Jefferson National Accelerator Facility (Jefferson Laboratory) and data collection was completed in the end of 2009. A highly specialized counting data acquisition system with an inherent particle identification was developed and utilized. We have taken data at two Q{sup 2} points in order to possibly address the hadronic correction due to higher twist effects. An overview of the experiment will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimating Subhourly Inverter Clipping Loss From Satellite-Derived Irradiance Data

Photovoltaic system production simulations are conventionally run using hourly weather datasets. Hourly simulations are sufficiently accurate to predict the majority of long-term system behavior but cannot resolve high-frequency effects like inverter clipping caused by short-duration irradiance variability. Direct modeling of this subhourly clipping error is only possible for the few locations with high-resolution irradiance datasets. This paper describes a method of predicting the magnitude of this error using a machine learning regressor ensemble model, comprised of a random forest and an XGBoost model, and 30-minute satellite irradiance data. The method predicts a correction for each 30-minute interval with the potential to roll up into 60-minute corrections to match an hourly energy model. The model is trained and validated at locations where the error can be directly simulated from 1-minute ground data. The validation shows low bias at most ground station locations. The model is also applied to gridded satellite irradiance to produce a heatmap of the estimated clipping error across the United States. Finally, the relative importance of each predictor satellite variable is retrieved from the model and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Coda Spectral Peaking for Nevada Nuclear Test Site Explosions

We have applied the regional S-wave coda calibration technique of Mayeda et al. (2003) to earthquake data in and around the Nevada Test Site (NTS) using 4 regional broadband stations from the LLNL seismic network. We applied the same path and site corrections to tamped nuclear explosion data and averaged the source spectra over the four stations. Narrowband coda amplitudes from the spectra were then regressed against inferred yield based on the regional m{sub b}(Pn) magnitude of Denny et al. (1987), along with the yield formulation of Vergino and Mensing (1990). We find the following: (1) The coda-derived spectra show a peak which is dependent upon emplacement depth, not event size; (2) Source size estimates are stable for the coda and show a dependence upon the near-source strength and gas porosity; (3) For explosions with the same m{sub b}(Pn) or inferred yield, those in weaker material have lower coda amplitudes at 1-3 Hz.

58 GEOSCIENCES↗

Estimating Subhourly Inverter Clipping Loss From Satellite-Derived Irradiance Data: Preprint

Photovoltaic system production simulations are conventionally run using hourly weather datasets. Hourly simulations are sufficiently accurate to predict the majority of long-term system behavior but cannot resolve high-frequency effects like inverter clipping caused by short-duration irradiance variability. Direct modeling of this subhourly clipping error is only possible for the few locations with high-resolution irradiance datasets. This paper describes a method of predicting the magnitude of this error using a machine learning model and 30-minute satellite irradiance data. The method predicts a correction for each 30-minute interval with the potential to roll up into 60-minute corrections to match an hourly energy model. The model is trained and validated at locations where the error can be directly simulated from 1-minute ground data. The validation shows low bias at most ground station locations. The model is also applied to gridded satellite irradiance to produce a heatmap of the estimated clipping error across the United States. Finally, the relative importance of each predictor satellite variable is retrieved from the model and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Towards operational atmospheric correction of airborne hyperspectral imaging spectroscopy: Algorithm evaluation, key parameter analysis, and machine learning emulators

Atmospheric correction of airborne hyperspectral imaging spectroscopy (AHIS) to obtain high-quality surface reflectance is the prerequisite for remote sensing applications. Over the last decades, different atmospheric correction methods have been developed based on radiative transfer models (RTMs), however, the relative performances of different algorithms are unclear. Automated operational atmospheric correction methods to process large-volume AHIS data in a high-accurate and high-throughput manner are still lacking. Therefore, this study proposed an operational atmospheric correction pipeline for deriving surface reflectance from AHIS data. To ensure the accuracy and efficiency of the pipeline, we focused on three specific aspects: (1) selecting a suitable RTM for the development of atmospheric lookup tables (LUTs) by comparing the commercial MODerate resolution atmospheric TRANsmission (MODTRAN) and open-sourced Library for Radiative TRANsfer (LibRadTRAN) models, where the widely-used software, Atmospheric/Topographic Correction for Airborne Imagery (ATCOR), was used as benchmarks; (2) identifying key atmospheric correction parameters and determining suitable sources for parameter retrievals including AHIS, Moderate Resolution Imaging Spectroradiometer (MODIS), and AErosol RObotic NETwork (AERONET); and (3) testing the performance of using machine learning emulators to speed up the RTM-based atmospheric correction. Results indicate that (1) atmospheric correction based on MODTRAN LUTs can produce surface reflectance accurately with mean absolute errors < 0.05 and cosine similarities > 0.98 compared to field measurements, which is comparable to the software ATCOR and slightly outperforms the LibRadTRAN LUTs; (2) sobol global sensitivity analysis demonstrates that in the atmospheric correction, visibility and water vapor are two key parameters that can be accurately derived from AHIS in contrast to MODIS or AERONET data; and (3) Random Forest emulators can produce accurate estimations of surface reflectance with mean absolute errors < 0.03 and cosine similarities > 0.98 for higher processing efficiency and determine a suitable set of wavelengths for retrieving atmospheric visibility and water vapor. In conclusion, the proposed atmospheric correction pipeline also improved the four-stream radiative transfer theory for airborne applications by considering adjacent effects from airborne surrounding pixels and can also be applied for atmospheric correction of hyperspectral data from spaceborne missions.

47 OTHER INSTRUMENTATION↗

Erratum to: Measurement of the inclusive jet cross-section in proton-proton collisions at $ \sqrt{s}=7 $ TeV using 4.5 fb -1 of data with the ATLAS detector

It was found that the non-perturbative corrections calculated using Pythia with the Perugia 2011 tune did not include the effect of the underlying event. The affected correction factors were recomputed using the Pythia 6.427 generator. These corrections are applied as baseline to the NLO pQCD calculations and thus the central values of the theoretical predictions have changed by a few percent with the new corrections. This has a minor impact on the agreement between the data and the theoretical predictions. Figures 2 and 6 to 13, and all the tables have been updated with the new values. A few sentences in the discussion in sections 5.2 and 9 were altered or removed.[Figure not available: see fulltext.]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Erratum to: Search for supersymmetry in final states with two same-sign or three leptons and jets using 36 fb -1 of $ \sqrt{s} $ = 13 TeV pp collision data with the ATLAS detector

One correction is made to the figure 4e of the paper. The reported cross-sections, both the experimental upper limits and the theoretical prediction, corresponded only to a fiducial region of the phase space with at least two prompt same-sign electrons or muons before detector simulation (p T > 10 GeV, |η| < 2.8). The updated figure 4e instead presents the results without this requirement, i.e. in the full phase space as it should, given the y-axis label of the plot. The reported sensitivity of the analysis, i.e. the ability to exclude top squark masses below 700 GeV in this scenario, is however unchanged since the same requirements were applied to the analysis and to the theory predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermochemical Data Fusion Using Graph Representation Learning

Large databases are required for “Big Data” applications in catalysis and materials science. Thermochemical databases can be created by combining data from various sources and by correcting low-fidelity datasets to higher accuracy with minimal computation. To achieve this “data fusion”, thermochemical quantities of interest, calculated at various levels of density functional theory (DFT), need to be mapped to the same, high levels of theory. In this work, a graph theoretical, statistical framework is proposed for such tasks. Subgraph frequencies are shown to provide a natural representation for learning these fusion maps. The maps are linear and are learnt with automated descriptor selection. Using a dataset of as few as ~1% from the QM9 database of 133,885 molecules, these models can predict multiple thermochemical quantities at a higher level of theory with an accuracy of 1 kcal/mol. Here, the method is explainable, generalizable, and provides a diagnostic tool for outlier identification

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reprocessed MPL data sets

This dataset contains reprocessed micropulse lidar (MPL) data (equivalent to the ARM cloud mask VAP's lidar fields) which were carefully corrected for each site. These reprocessed data were used in Silber et al. (JGR, 2018). The data extend up to a height of 15 km and have vertical and temporal resolutions of 15 m and 30 s, respectively.

54 ENVIRONMENTAL SCIENCES↗

Highly Selective and Stable Multivariable Gas Sensors for Enhanced Robustness and Reliability of SOFC Operation

GE Global Research, in partnership with SUNY Polytechnic Institute (SUNY Poly) and GE–Fuel Cells LLC, designed, built, and tested multi-gas sensor prototypes for in situ monitoring of gases produced during steam reforming in solid oxide fuel cell (SOFC) systems. To be widely adopted and to deliver a lower operating cost for customers, SOFC systems should enhance their operation reliability and improve stack robustness. These needs can be achieved by early diagnostics of potential upsets by using in-situ gas sensors for the real-time monitoring of gas mixture compositions. Thus, this project objective was to achieve selectivity and stability of sensing of gases for SOFC applications by implementing a new generation of gas sensors, known as multivariable sensors. Such sensors are intended to complement the mature traditional analytical instruments based on sensor performance and design characteristics. The key sensor-performance characteristics include accurate detection and quantitation of several gases in their mixtures and stability of operation in unattended applications. The key design characteristics of sensors include their unobtrusive form factor and cost-effectiveness. The duration of the project was 18 months with the project structure that included three technical tasks such as (1) design and laboratory validation of multivariable sensors for selective detection of H 2 and CO gases, (2) laboratory validation of sensor stability over a two-week testing, and (3) field-validation of the developed multivariable sensor system prototype at GE–Fuel Cells factory. Multi-gas detection was achieved with multivariable photonic sensors designed to operate at elevated temperature. The sensor design was based on three-dimensional (3D) bio-inspired photonic nanostructure that was fabricated using materials responsive to gases of interest such as H 2 and CO. The gas discrimination and the rejection of interferences such as CH 4 , H 2 O, and others was performed by optimizing the design parameters of the 3D photonic nanostructures such as their composition and morphology. Planar sol-gel and sputtered sensing films were fabricated as controls. As a result of the fabrication, functionalization, excitation, and performance testing of 3D photonic sensors, we developed initial design rules for high temperature multivariable sensors. These design rules pave the way for the new generation of cost-effective industrial sensors. Stability of sensor operation was tested in the laboratory conditions under variations of the ambient environments. Stability tests were designed in the order of enhanced complexity and realism of sensor operation and included quantitation of a single gas, quantitation of a single gas in the presence of interferences, and quantitation of two and three gases. We have found that conventional machine learning data analysis stools were unable to correct for the sensor drift. Thus, we have developed new methods of machine learning data analysis that provided us with needed performance stability. Such performance improvement in gas sensing was a significant milestone in bringing our multivariable sensors to practical applications. The project culminated with initial field validation of developed multivariable sensor prototypes at GE–Fuel Cells LLC. The in situ data generated by the sensor system in the lab and field conditions provided inputs that advanced our fundamental understanding of gas sensing at high temperatures to enable sensors for SOFC applications and allowed development of the recommendations for further deliverables.

47 OTHER INSTRUMENTATION↗