Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coordinated control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controller for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype controller for the ESTAR (electronically scanned thinned array radiometer) instrument has been designed and tested. It manages the operation of the digital data subsystem (DDS) and its communication with the Small Explorer data system (SEDS). Among the data processing tasks that it coordinates are FEM data acquisition, noise removal, phase alignment and correlation. Its control functions include instrument calibration and testing of two critical subsystems, the output data formatter and Walsh function generator. It is implemented in a Xilinx XC3064PC84-100 field programmable gate array (FPGA) and has a maximum clocking frequency of 10 MHz.

Zomberg, Brian G.↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows: Preprint

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 1.6% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Protecting and Defending against Autonomous Control Systems and Digital Twin Cyber Attacks: Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Models in Nuclear Power Plants (Final)

Navigating through the complex tapestry of technological advancements, "Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Model in Nuclear Power Plants" stands at the intersection of cybersecurity and nuclear power plant operations, embarking on a journey through the intricacies of securing digital twins against malicious cyber activities. As nuclear power plants progressively integrate digital twin technology and machine learning models to optimize operations and ensure system reliability, they inadvertently expose themselves to a new spectrum of vulnerabilities, notably in the realm of hyperparameter attacks. Hyperparameters, integral in machine learning model tuning and optimal performance of digital twins, have emerged as a target for adversaries aiming to destabilize the predictive capabilities and therefore, the operational accuracy of these digital entities within critical infrastructures like nuclear plants. This paper, therefore, meticulously threads the needle through the development of a robust response strategy, poised to shield these digital reflections against calculated hyperparameter manipulations, ensuring that the digital twin can effectively and securely function as a reliable proxy for its physical counterpart. The ensuing sections delve into the orchestrated maelstrom of multi-rate time-changing intelligent coordinated hyperparameter attacks and the implementation of event-triggered predictive control, laying down a structured, predictive, and responsive framework that safeguards the nexus where the digital and physical realms of nuclear power plants coalesce. The operational integrity of digital twins in nuclear power plants depends critically on the security of machine learning hyperparameters. This study makes two different contributions. First, a decision-based idea known as a multi-rate time changing intelligent coordinated hyperparameter attack is put forth. In this attack, many hyperparameters are repeatedly changed using both random and intelligent optimal techniques by the attacker. These assaults introduce varied rates at different attack steps, compromise various amounts of hyperparameters, and improve stealth and flexibility. Second, a technique is developed for event triggered predictive control to rapidly respond to potential hyperparameter attacks. This control integrates a sliding window framework, retaining a history of previous data points and employing linear regression to predict the next data point from the current dataset. The control gain K is determined using the Lyapunov-Krasovskii method, and subsequently, an action is developed. Finally, the outcome of the simulation demonstrates the viability of the proposed method for defending nuclear power plant digital twins from hyperparameter attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ligand-coordination effects on the selective hydrogenation of acetylene in single-site Pd-ligand supported catalysts

The selective hydrogenation of acetylene to ethylene is a critical step in the synthesis of polyethylenes. Achieving high conversion to ethylene without over-hydrogenation to ethane is a challenge that requires control of the transition metal site, which we achieve through a ligand-coordinated supported catalyst (LCSC) strategy. Using Pd catalysts coordinated to 1,10-phenanthroline-5,6-dione (PDO) ligands on CeO2 supports, we have discovered that the reaction selectivity depends strongly on the ligand:metal ratio with higher selectivity when more ligand is present in the catalyst. Catalyst structure was examined by extended X-ray absorption fine structure spectroscopy, transmission electron microscopy, and CO adsorption, which indicate single-atom character of the Pd. The ligand:metal ratio is determined by Xray photoelectron spectroscopy measurements and correlated with hydrogenation reactions under steady-state flow conditions to examine trends in hydrogenation activity and selectivity. Those trends can be better understood by density functional theory calculations that indicate hydrogen binding on the ligand to guide reaction selectivity toward the desired ethylene hydrogenation product. Here these results demonstrate the importance of considering the dynamic character of LCSCs and inform the design of future single-site heterogeneous catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Approximate Dynamic Programming With Enhanced Off-Policy Learning for Coordinating Distributed Energy Resources

Herein this paper proposes an innovative approximate dynamic programming (ADP) method for distributed energy resource coordination with the loss of life of battery energy storage system (BESS) explicitly modeled. The dispatch policy is designed to account for both calendrical and cyclical aging effects on BESS, explicitly modeling the impacts of ambient temperature on BESS lifespan. The proposed ADP employs an adaptive critic method and enhanced off-policy deterministic policy gradient (DPG) strategy, addressing the limitations of the on-policy gradient-based ADP approaches, including inadequate exploration, low data usage, and computational complexity. In particular, a customized policy is proposed to guide the algorithm to explore some promising decisions and thereby improve exploration capability and learning efficiency compared to conventional DPG-based learning approaches, which may struggle to find a global optimum due to random noisy action-based exploration or require expert demonstration with extra effort. The proposed method is illustrated using the IEEE 123-node system and compared with the existing ADP methods to prove solution accuracy and demonstrate the effects of incorporating degradation models into control design. Case studies showed that the proposed ADP effectively coordinates DERs with a 10 times smaller optimization gap compared to existing methods, and the incorporation of the BESS life loss model ensures the expected lifespan and results in significant cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal estimation and attitude control of a solar electric propulsion spacecraft

Established procedures of linear, quadratic, Gaussian optimal estimation and control are developed and interpreted for their application to the problem of attitude control of spacecraft with dynamically significant elastic appendages. Results are presented both in general terms and for specific application to a solar electric spacecraft. Comparisons are made between alternative coordinate systems, and a realistic range of design parameters is considered. For single axis control, system evaluation is accomplished by simulation of a fifteenth-order spacecraft plant with alternative second-order, fourth-order, and sixth-order constant gain estimators. Results point out the importance of modeling errors.

Larson, V.↗

Configuration control of redundant manipulators - Theory and implementation

A simple approach for controlling the manipulator configuration over the entire motion is presented, based on augmentation of the manipulator forward kinematics. User-defined kinematic functions and the end-effector Cartesian coordinates are combined to form a set of task-related configuration variables as generalized coordinates for the manipulator. A task-based adaptive scheme is then utilized to control the configuration variables and achieve tracking of the desired reference trajectories. This achieves the desired end-effector motion while utilizing redundancy to achieve any additional task. Simulation results for a direct-drive two-link arm are given to illustrate the proposed control scheme. The scheme has also been implemented for real-time control of three links of a PUMA 560 industrial robot. The simulation and experimental results validate the configuration control scheme and demonstrate its capabilities for performing various realistic tasks.

Seraji, Homayoun↗

Model-Based Detection of Coordinated Attacks (DCA) in Distribution Systems

The fast-paced growth in digitization of smart grid components enhances system observability and remote-control capabilities through efficient communication. However, enhanced connectivity results in heightened system vulnerability towards cybersecurity risks in the cyber-physical power system. Coordinated cyber-attacks (CCA), when undetected, lead to system-wide impact in terms of large disturbances or widespread outages. Detecting CCA in the cyber layer is critical to thwart cyber-attacks in real-time before the attack impacts the physical system. The challenge of locating CCA stems from the complex grid dynamics, making it difficult to distinguish between normal operational variations and cyber-attack impact. CCA often employs multiple attack vectors targeting geographically distributed components, further complicating CCA identification. Existing research in intrusion detection is primarily focused on the transmission network and limited to detecting individual attacks. In this paper, a novel proactive DCA strategy is proposed for early detection of CCA by establishing correlations among distinct attack events through model-based reinforcement learning that utilizes abductive reasoning to conclude the attacker goal. The solution includes understanding the system model, learning the system dynamics, and correlating individual cyber-attacks to extract the attacker’s objective. The developed learning algorithm identifies the most probable attack path to reach the attacker’s objective by predicting the next attack steps. A DNP3-based cyber-physical co-simulation testbed is developed to test the proposed algorithm using the IEEE 13-node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A simulation‐based integrated virtual testbed for dynamic optimization in smart manufacturing systems

Abstract In a manufacturing system, production control‐related decision‐making activities occur at different levels. At the process level, one of the main control activities is to tune the parameters of individual manufacturing equipment. At the system level, the main activity is to coordinate production resources and to route parts to appropriate workstations based on their processing requirement, priority indices, and control policy. At the factory level, the goal is to plan and schedule the processing of parts at different operations for the entire system in order to optimize certain objectives. Note that the results of such activities at different levels are closely coupled and affect the overall performance of the manufacturing system as a whole. Therefore, it is important to systematically integrate these control and optimization activities into one unified platform to ensure the goal of each individual activity is aligned with the overall performance of the system. In this paper, we develop a simulation‐based virtual testbed that implements dynamic optimization, automatic information exchange, and decision‐making from the process‐level, system‐level, and factory‐level of a manufacturing system into an integrated computation environment. This is demonstrated by connecting a Python‐based numerical computation program, discrete‐event simulation software (Simul8), and an optimization solver (CPLEX) via a third‐party master program. The application of this simulation‐based virtual testbed is illustrated by a case study in a machining shop.

Sun, Yuting↗

Term Matrix: a novel Gene Ontology annotation quality control system based on ontology term co-annotation patterns

Biological processes are accomplished by the coordinated action of gene products. Gene products often participate in multiple processes, and can therefore be annotated to multiple Gene Ontology (GO) terms. Nevertheless, processes that are functionally, temporally and/or spatially distant may have few gene products in common, and co-annotation to unrelated processes probably reflects errors in literature curation, ontology structure or automated annotation pipelines. We have developed an annotation quality control workflow that uses rules based on mutually exclusive processes to detect annotation errors, based on and validated by case studies including the three we present here: fission yeast protein-coding gene annotations over time; annotations for cohesin complex subunits in human and model species; and annotations using a selected set of GO biological process terms in human and five model species. For each case study, we reviewed available GO annotations, identified pairs of biological processes which are unlikely to be correctly co-annotated to the same gene products (e.g. amino acid metabolism and cytokinesis), and traced erroneous annotations to their sources. To date we have generated 107 quality control rules, and corrected 289 manual annotations in eukaryotes and over 52 700 automatically propagated annotations across all taxa.

59 BASIC BIOLOGICAL SCIENCES↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Beyond Control Centers

For NASA's Resource Prospector (RP) Lunar Rover Mission, we are moving away from a control center concept, to a fully distributed operation utilizing control nodes, with decision support from anywhere via mobile devices. This operations concept will utilize distributed information systems, notifications, mobile data access, and optimized mobile data display for off-console decision support. We see this concept of operations as a step in the evolution of mission operations from a central control center concept to a mission operations anywhere concept. The RP example is part of a trend, in which mission expertise for design, development and operations is distributed across countries and across the globe. Future spacecraft operations will be most cost efficient and flexible by following this distributed expertise, enabling operations from anywhere. For the RP mission we arrived at the decision to utilize a fully distributed operations team, where everyone operates from their home institution, based on evaluating the following factors: the requirement for physical proximity for near-real time command and control decisions; the cost of distributed control nodes vs. a centralized control center; the impact on training and mission preparation of flying the team to a central location. Physical proximity for operational decisions is seldom required, though certain categories of decisions, such as launch abort, or close coordination for mission or safety-critical near-real-time command and control decisions may benefit from co-location. The cost of facilities and operational infrastructure has not been found to be a driving factor for location in our studies. Mission training and preparation benefit from having all operators train and operate from home institutions.

Operations↗

A new approach to global control of redundant manipulators

A new and simple approach to configuration control of redundant manipulators is presented. In this approach, the redundancy is utilized to control the manipulator configuration directly in task space, where the task will be performed. A number of kinematic functions are defined to reflect the desirable configuration that will be achieved for a given end-effector position. The user-defined kinematic functions and the end-effector Cartesian coordinates are combined to form a set of task-related configuration variables as generalized coordinates for the manipulator. An adaptive scheme is then utilized to globally control the configuration variables so as to achieve tracking of some desired reference trajectories. This accomplishes the basic task of desired end-effector motion, while utilizing the redundancy to achieve any additional task through the desired time variation of the kinematic functions. The control law is simple and computationally very fast, and does not require the complex manipulator dynamic model.

Seraji, Homayoun↗

Controlling Air Conditioners for Frequency Regulation: A Real-World Example

Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. Here, we argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discrete regulation of transfer function of a circuit in experimental data automatic collection and processing systems

A device for discrete control of the circuit transfer function in automatic analog data processing systems is reported that coordinates the dynamic range of the vibration level change with the signal range of the processing device output. Experimental verification of the device demonstrates that its maximum control speed does not exceed 0.5 sec for a frequency nonuniformity of about 10%.

Lyubashevskiy, G. S.↗

A comparison of CMG steering laws for High Energy Astronomy Observatories (HEAOs)

A comparison of six selected control moment gyro steering laws for use on the HEAO spacecraft is reported. Basic equations are developed to project the momentum and torque of four skewed, single gimbal CMGs into vehicle coordinates. In response to the spacecraft attitude error signal, six algorithms are derived for controlling the CMG gimbal movements. HEAO performance data are obtained using each steering law and compared on the basis of such factors as accuracy, complexity, singularities, gyro hang-up and failure adaption. Moreover, each law is simulated with and without a magnetic momentum management system. The performance of any steering law is enhanced by the magnetic system. Without magnetics, the gimbal angles get large and there are significant differences in steering law performances due to cross coupling and nonlinearities. The performance of the pseudo inverse law is recommended for HEAO.

Davis, B. G.↗