At least 1,117 records · Page 62

Uniformly decaying subspaces for error-mitigated quantum computation

Here, we present a general condition to obtain subspaces that decay uniformly in a system governed by the Lindblad master equation and use them to perform error-mitigated quantum computation. The expectation values of dynamics encoded in such subspaces are unbiased estimators of noise-free expectation values. In analogy to the decoherence free subspaces which are left invariant by the action of Lindblad operators, we show that the uniformly decaying subspaces are left invariant (up to orthogonal terms) by the action of the dissipative part of the Lindblad equation. We apply our theory to a system of qubits and qudits undergoing relaxation with varying decay rates and show that such subspaces can be used to eliminate bias up to first-order variations in the decay rates without requiring full knowledge of noise. Since such a bias cannot be corrected through standard symmetry verification, our method can improve error mitigation in dual-rail qubits and, given partial knowledge of noise, can perform better than probabilistic error cancellation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of new depletion capabilities and ENDF/B-VII data libraries in Scale

New isotopic depletion capabilities and ENDF/B-VII data libraries have been implemented in the recent release 6.1 of Scale, a comprehensive modeling and simulation suite for nuclear safety analysis and design developed and maintained by Oak Ridge National Laboratory. An assessment of the effect of these developments on the code performance is the subject of this paper. The analysis is focused on evaluating the code performance in predicting isotopic compositions in spent nuclear fuel by using an extensive, measured isotopic assay database. The analysis results obtained using the latest ENDF/B-VII cross-section data and different resonance processing methods in Scale are compared to the results of previous validation studies that used ENDF/B-V data. The performance of Scale depletion capabilities with respect to other computational systems is assessed based on recent published results that were obtained using ENDF/B-VII libraries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Asynchronous-many-task systems: Challenges and opportunities - Scaling an AMR astrophysics code on exascale machines using Kokkos and HPX

Dynamic and adaptive mesh refinement is pivotal in high-resolution, multi-physics, multi-model simulations, necessitating precise physics resolution in localized areas across expansive domains. Today’s supercomputers’ extreme heterogeneity presents a significant challenge for dynamically adaptive codes, highlighting the importance of achieving performance portability at scale. Our research focuses on astrophysical simulations, particularly stellar mergers, to elucidate early universe dynamics. Here, we present Octo-Tiger, leveraging Kokkos, HPX, and SIMD for portable performance at scale in complex, massively parallel adaptive multi-physics simulations. Octo-Tiger supports diverse processors, accelerators, and network backends. Experiments demonstrate exceptional scalability across several heterogeneous supercomputers including Perlmutter, Frontier, and Fugaku, encompassing major GPU architectures and x86, ARM, and RISC-V CPUs. Parallel efficiency of 47.59% (110,080 cores and 6880 hybrid A100 GPUs) on a full-system run on Perlmutter (26% HPCG peak performance) and 51.37% (using 32,768 cores and 2048 MI250X) on Frontier are achieved.

97 MATHEMATICS AND COMPUTING↗

Supporting the Global Arrays PGAS Model Using MPI One-Sided Communication

The industry-standard Message Passing Interface (MPI) provides one-sided communication functionality and is available on virtually every parallel computing system. However, it is believed that MPI’s one-sided model is not rich enough to support higher-level global address space parallel programming models. We present the first successful application of MPI one-sided communication as a runtime system for a PGAS model, Global Arrays (GA). This work has an immediate impact on users of GA applications, such as NWChem, who often must wait several months to a year or more before GA becomes available on a new architecture. We explore challenges present in the application of MPI-2 to PGAS models and motivate new features in the upcoming MPI-3 standard. The performance of our system is evaluated on several popular high-performance computing architectures through communication benchmarking and application benchmarking using the NWChem computational chemistry suite.

ARMCI↗

Constructing Surrogate Models of Complex Systems with Enhanced Sparsity: Quantifying the influence of conformational uncertainty in biomolecular solvation

Biomolecules exhibit conformational fluctuations near equilibrium states, inducing uncertainty in various biological properties in a dynamic way. We have developed a general method to quantify the uncertainty of target properties induced by conformational fluctuations. Using a generalized polynomial chaos (gPC) expansion, we construct a surrogate model of the target property with respect to varying conformational states. We also propose a method to increase the sparsity of the gPC expansion by defining a set of conformational “active space” random variables. With the increased sparsity, we employ the compressive sensing method to accurately construct the surrogate model. We demonstrate the performance of the surrogate model by evaluating fluctuation-induced uncertainty in solvent-accessible surface area for the bovine trypsin inhibitor protein system and show that the new approach offers more accurate statistical information than standard Monte Carlo approaches. Further more, the constructed surrogate model also enables us to directly evaluate the target property under various conformational states, yielding a more accurate response surface than standard sparse grid collocation methods. In particular, the new method provides higher accuracy in high-dimensional systems, such as biomolecules, where sparse grid performance is limited by the accuracy of the computed quantity of interest. Our new framework is generalizable and can be used to investigate the uncertainty of a wide variety of target properties in biomolecular systems.

coarse graining↗

Automated Patient Identification and Localization Error Detection Using 2-Dimensional to 3-Dimensional Registration of Kilovoltage X-Ray Setup Images

Purpose: To determine whether kilovoltage x-ray projection radiation therapy setup images could be used to perform patient identification and detect gross errors in patient setup using a computer algorithm. Methods and Materials: Three patient cohorts treated using a commercially available image guided radiation therapy (IGRT) system that uses 2-dimensional to 3-dimensional (2D-3D) image registration were retrospectively analyzed: a group of 100 cranial radiation therapy patients, a group of 100 prostate cancer patients, and a group of 83 patients treated for spinal lesions. The setup images were acquired using fixed in-room kilovoltage imaging systems. In the prostate and cranial patient groups, localizations using image registration were performed between computed tomography (CT) simulation images from radiation therapy planning and setup x-ray images corresponding both to the same patient and to different patients. For the spinal patients, localizations were performed to the correct vertebral body, and to an adjacent vertebral body, using planning CTs and setup x-ray images from the same patient. An image similarity measure used by the IGRT system image registration algorithm was extracted from the IGRT system log files and evaluated as a discriminant for error detection. Results: A threshold value of the similarity measure could be chosen to separate correct and incorrect patient matches and correct and incorrect vertebral body localizations with excellent accuracy for these patient cohorts. A 10-fold cross-validation using linear discriminant analysis yielded misclassification probabilities of 0.000, 0.0045, and 0.014 for the cranial, prostate, and spinal cases, respectively. Conclusions: An automated measure of the image similarity between x-ray setup images and corresponding planning CT images could be used to perform automated patient identification and detection of localization errors in radiation therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AHEAD: A Tool for Projecting Next-Generation Hardware Enhancements on GPU-Accelerated Systems

Starting with the Titan supercomputer (at the Oak Ridge Leadership Computing Facility, OLCF) in 2012, top supercomputers have Increasingly leveraged the performance of GPUs to support large-scale computational science. The current No. 1 machine, the 200 petaflop Summit system at OLCF, is a GPU-based machine. Accelerator-based architectures, however, add additional complexity due to node heterogeneity. To inform procurement decisions, supercomputing centers need the tools to quickly model the impact of changes of the node architectures on application performance. We present AHEAD, a profiling and modeling tool to quantify the impact of intra-node communication mechanism (e.g., PCI or NVLink) on application performance. Our experiments show average weighted relative errors of ~19% and ~23% for five CORAL-2 (a collaboration between multiple US Department of Energy, DOE, labs to procure Exascale systems) and 12 Rodinia benchmarks respectively, without running the applications on the target future node.

Abdelhafez, Hazem A.↗

Stochastic self-tuning hybrid algorithm for reaction-diffusion systems

Many biochemical phenomena involve reactants with vastly different concentrations, some of which are amenable to continuum-level descriptions, while the others are not. We present a hybrid self-tuning algorithm to model such systems. The method combines microscopic (Brownian) dynamics for diffusion with mesoscopic (Gillespie-type) methods for reactions and remains efficient in a wide range of regimes and scenarios with large variations of concentrations. Furthermore, its accuracy, robustness, and versatility are balanced by redefining propensities and optimizing the mesh size and time step. We use a bimolecular reaction to demonstrate the potential of our method in a broad spectrum of scenarios: from almost completely reaction-dominated systems to cases where reactions rarely occur or take place very slowly. The simulation results show that the number of particles present in the system does not degrade the performance of our method. This makes it an accurate and computationally efficient tool to model complex multireaction systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-BRD-03: Development of a Real-Time Optical Tracking Goggle System (OTGS) for Intracranial Stereotactic Radiotherapy

Purpose: Optical tracking systems (OTS) are an acceptable alternative to frame-based stereotactic radiotherapy (SRT). However, current surface-based OTS lack the ability to target exclusively rigid/bony anatomical features. We propose a novel marker-based optical tracking goggle system (OTGS) that provides real-time guidance based on the nose/facial bony anatomy. This ongoing study involves the development and characterization of the OTGS for clinical implementation in intracranial stereotactic radiotherapy. Methods: The OTGS consists of eye goggles, a custom thermoplastic nosepiece, and 6 infrared markers pre-attached to the goggles. A phantom and four healthy volunteers were used to evaluate the calibration/registration accuracy, intrafraction accuracy, interfraction reproducibility, and end-to-end accuracy of the OTGS. The performance of the OTGS was compared with that of the frameless SonArray system and cone-beam computed tomography (CBCT) for volunteer and phantom cases, respectively. The performance of the OTGS with commercial immobilization devices and under treatment conditions (i.e., couch rotation and translation range) was also evaluated. Results: The difference in the calibration/registration accuracy of 24 translations or rotation combinations between CBCT and in-house OTS software was within 0.5 mm/0.4°. The mean intrafraction and interfraction accuracy among the volunteers was 0.004+/−0.4mm with −0.09+/−0.5° (n=6,170) and −0.26+/−0.8mm with 0.15+/0.8° (n=11), respectively. The difference in end-to-end accuracy between the OTGS and CBCT was within 1.3 mm/1.1°. The predetermined marker pattern (1) minimized marker occlusions, (2) allowed for continuous tracking for couch angles +/− 90°, (3) and eliminated individual marker misplacement. The device was feasible with open and half masks for immobilization. Conclusion: Bony anatomical localization eliminated potential errors due to facial hair changes and/or soft tissue deformation. The OTGS offers a workflow-friendly, patient-friendly solution for intracranial SRT, while being comparable to other real-time options. The minimum rotation uncertainty of the OTGS can be combined with CBCT to ensure maximum accuracy for high-precision SRT.

60 APPLIED LIFE SCIENCES↗

NEAMS Update: Quarterly Report for October - December 2011

The Advanced Modeling and Simulation Office within the DOE Office of Nuclear Energy (NE) has been charged with revolutionizing the design tools used to build nuclear power plants during the next 10 years. To accomplish this, the DOE has brought together the national laboratories, U.S. universities, and the nuclear energy industry to establish the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program. The mission of NEAMS is to modernize computer modeling of nuclear energy systems and improve the fidelity and validity of modeling results using contemporary software environments and high-performance computers. NEAMS will create a set of engineering-level codes aimed at designing and analyzing the performance and safety of nuclear power plants and reactor fuels. The truly predictive nature of these codes will be achieved by modeling the governing phenomena at the spatial and temporal scales that dominate the behavior. These codes will be executed within a simulation environment that orchestrates code integration with respect to spatial meshing, computational resources, and execution to give the user a common 'look and feel' for setting up problems and displaying results. NEAMS is building upon a suite of existing simulation tools, including those developed by the federal Scientific Discovery through Advanced Computing and Advanced Simulation and Computing programs. NEAMS also draws upon existing simulation tools for materials and nuclear systems, although many of these are limited in terms of scale, applicability, and portability (their ability to be integrated into contemporary software and hardware architectures). NEAMS investments have directly and indirectly supported additional NE research and development programs, including those devoted to waste repositories, safeguarded separations systems, and long-term storage of used nuclear fuel. NEAMS is organized into two broad efforts, each comprising four elements. The quarterly highlights October-December 2011 are: (1) Version 1.0 of AMP, the fuel assembly performance code, was tested on the JAGUAR supercomputer and released on November 1, 2011, a detailed discussion of this new simulation tool is given; (2) A coolant sub-channel model and a preliminary UO{sub 2} smeared-cracking model were implemented in BISON, the single-pin fuel code, more information on how these models were developed and benchmarked is given; (3) The Object Kinetic Monte Carlo model was implemented to account for nucleation events in meso-scale simulations and a discussion of the significance of this advance is given; (4) The SHARP neutronics module, PROTEUS, was expanded to be applicable to all types of reactors, and a discussion of the importance of PROTEUS is given; (5) A plan has been finalized for integrating the high-fidelity, three-dimensional reactor code SHARP with both the systems-level code RELAP7 and the fuel assembly code AMP. This is a new initiative; (6) Work began to evaluate the applicability of AMP to the problem of dry storage of used fuel and to define a relevant problem to test the applicability; (7) A code to obtain phonon spectra from the force-constant matrix for a crystalline lattice has been completed. This important bridge between subcontinuum and continuum phenomena is discussed; (8) Benchmarking was begun on the meso-scale, finite-element fuels code MARMOT to validate its new variable splitting algorithm; (9) A very computationally demanding simulation of diffusion-driven nucleation of new microstructural features has been completed. An explanation of the difficulty of this simulation is given; (10) Experiments were conducted with deformed steel to validate a crystal plasticity finite-element code for bodycentered cubic iron; (11) The Capability Transfer Roadmap was completed and published as an internal laboratory technical report; (12) The AMP fuel assembly code input generator was integrated into the NEAMS Integrated Computational Environment (NiCE). More details on the planned NEAMS computing environment is given; and (13) The NEAMS program website (neams.energy.gov) is nearly ready to launch.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cross-Layer Self-Adaptive/Self-Aware System Software for Exascale Systems

The extreme level of parallelism coupled with the limited available power budget expected in the exascale era brings unprecedented challenges that demand optimization of performance, power and resiliency in unison. Scalability on such systems is of paramount importance, while power and reliability issues may change the execution environment in which a parallel application runs. To solve these challenges exascale systems will require an introspective system software that combines system and application observations across all system stack layers with online feedback and adaptation mechanisms. In this paper we propose the design of a novel self-aware, self-adaptive system software in which a kernel-level Monitor, which continuously inspects the evolution of the target system through observation of Sensors, is combined with a user-level Controller, which reacts to changes in the execution environment, explores opportunities to increase performance, save power and adapts applications to new execution scenarios. We show that the monitoring system accurately monitors the evolution of parallel applications with a runtime overhead below 1-2%. As a test case, we design and implement a user-runtime system that aims at optimizing application’s performance and system power consumption on complex hierarchical architectures. Our results show that our adaptive system reaches 98% of performance efficiency of manually-tuned applications.

High Performance computing, Self-aware/self-adapti↗

SU-F-J-47: Inherent Uncertainty in the Positional Shifts Determined by a Volumetric Cone Beam Imaging System

Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeated 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.

60 APPLIED LIFE SCIENCES↗

Experimental validation of different modeling approaches for solid particle receivers.

Solid particle receivers have the potential to provide high-temperature heat for advanced power cycles, thermochemical processes, and thermal storage via direct particle absorption of concentrated solar energy. This paper presents two different models to evaluate the performance of these systems. One model is a detailed computational fluid dynamics model using FLUENT that includes irradiation from the concentrated solar flux, two-band re-radiation and emission within the cavity, discrete-phase particle transport and heat transfer, gas-phase convection, wall conduction, and radiative and convective heat losses. The second model is an easy-to-use and fast simulation code using Matlab that includes solar and thermal radiation exchange between the particle curtain, cavity walls, and aperture, but neglects convection. Both models were compared to unheated particle flow tests and to on-sun heating tests. Comparisons between measured and simulated particle velocities, opacity, particle volume fractions, particle temperatures, and thermal efficiencies were found to be in good agreement. Sensitivity studies were also performed with the models to identify parameters and modifications to improve the performance of the solid particle receiver.

14 SOLAR ENERGY↗

High fidelity nuclear energy system optimization towards an environmentally benign, sustainable, and secure energy source.

A new high-fidelity integrated system method and analysis approach was developed and implemented for consistent and comprehensive evaluations of advanced fuel cycles leading to minimized Transuranic (TRU) inventories. The method has been implemented in a developed code system integrating capabilities of Monte Carlo N - Particle Extended (MCNPX) for high-fidelity fuel cycle component simulations. In this report, a Nuclear Energy System (NES) configuration was developed to take advantage of used fuel recycling and transmutation capabilities in waste management scenarios leading to minimized TRU waste inventories, long-term activities, and radiotoxicities. The reactor systems and fuel cycle components that make up the NES were selected for their ability to perform in tandem to produce clean, safe, and dependable energy in an environmentally conscious manner. The diversity in performance and spectral characteristics were used to enhance TRU waste elimination while efficiently utilizing uranium resources and providing an abundant energy source. A computational modeling approach was developed for integrating the individual models of the NES. A general approach was utilized allowing for the Integrated System Model (ISM) to be modified in order to provide simulation for other systems with similar attributes. By utilizing this approach, the ISM is capable of performing system evaluations under many different design parameter options. Additionally, the predictive capabilities of the ISM and its computational time efficiency allow for system sensitivity/uncertainty analysis and the implementation of optimization techniques.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantum computing for nuclear physics

Future quantum computers are anticipated to be able to perform simulations of quantum many-body systems and quantum field theories that lie beyond the capabilities of classical computation. This will lead to new insights and predictions for systems ranging from dense non-equilibrium matter, to low-energy nuclear structure and reactions, to high-energy collisions. I present an overview of digital quantum simulations in nuclear physics, with select examples relevant for studies of quark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Fidelity Calibration and Characterization of Hyperspectral Computed Tomography System

This document archives the results developed by the Lab Directed Research and Development (LDRD) project sponsored by Sandia National Laboratories (SNL). In this work, a numerical study was performed to show the feasibility of approximating the non-linear operator of SNL's unique high-energy hyperspectral computed tomography system as a sequence of linear operators. The four main results gained from this work include the development of a simulation test-bed using a particle-transport Monte Carlo approach; the demonstration to assemble a linear operator of almost-arbitrary resolution for a given narrow energy window, developing a compression approach to dramatically reduce the size of the linear operator via a spline approach, and the demonstration of using the linear operator to perform processing of x-ray data; in this case, the development of an iterative reconstruction method. This numerical study has indicated that if these results can be replicated on the SNL system, the improved performance could be revolutionary as the method to approximate the nonlinear operator for a hyperspectral CT system is not feasible to perform on a traditional CT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SimCCS: An open-source tool for optimizing CO 2 capture, transport, and storage infrastructure

Commercial-scale carbon capture and storage (CCS) technology will involve deploying infrastructure on a massive and costly scale. This effort will require careful and comprehensive planning to ensure that capture locations, storage sites, and the dedicated CO 2 distribution pipelines are selected in a robust and cost-effective manner. Presented in 2009, SimCCS is an optimization model for integrated system design that enables researchers, stakeholders, and policy makers to design CCS infrastructure networks. SimCCS 2.0 is a complete, ground-up redesign that is now a portable software package, useable and shareable by the CCS research, industrial, policy, and public communities. SimCCS 2.0 integrates multiple new capabilities including a refined optimization model, novel candidate network generation techniques, and optional integration with high-performance computing platforms. Accessing user-provided CO 2 source, sink, and transportation data, SimCCS 2.0 creates candidate transportation routes and formalizes an optimization problem that determines the most cost-effective CCS system design. This optimization problem is further solved either through a high-performance computing interface, or through third-party software on a local desktop computing platform. Finally, SimCCS 2.0 employs an open-access geographic information system framework to enable analysis and visualization capabilities. SimCCS 2.0 is written in Java and is publicly available via GitHub to encourage collaboration, modification, and community development.

42 ENGINEERING↗

Verification of the PERSENT Software

Ongoing commercial design activities require a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system and substantial work has been done to verify its accuracy on several identified commercial needs. This manuscript details the verification work done on PERSENT which relies upon the DIF3D code for its forward and adjoint flux solution. Previous work identified the PERSENT features required to be verified to support commercial design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying PERSENT’s ability to correctly calculate four key quantities: perturbation worth distributions, kinetics parameters, sensitivity coefficients, and cross section uncertainty quantification. This manuscript provides the verification tasks and their results with respect to these quantities needed for commercial design activities. For the perturbation worth distributions, hand calculations are deployed to verify the PERSENT calculated results. Similarly, hand calculation of the PERSENT computed kinetics parameters is also used to verify the PERSENT results. In both of these, the input to PERSENT is manipulated to ensure the hand calculation exactly matches the equations PERSENT is calculating. The sensitivity coefficients involve calculating the derivatives of a parameter (such as reactivity worth), with respect to the cross section data. Direct finite difference calculations with DIF3D are used to verify the PERSENT calculated results. For the uncertainty quantification, manufactured input to PERSENT is used to allow an exact hand calculation to reproduce the PERSENT calculated results. The work detailed in this report verified that significant issues were identified for earlier versions of PERSENT for sensitivity coefficients which were corrected in this work and thus version 12.1.0 of PERSENT must be used to reproduce all of the verified work in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗