Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coding standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

An XML-hierarchical data structure for ENSDF

A data structure based on an eXtensible Markup Language (XML) hierarchy according to experimental nuclear structure data in the Evaluated Nuclear Structure Data File (ENSDF) is presented. A Python-coded translator has been developed to interpret the standard one-card records of the ENSDF datasets, together with their associated quantities defined according to field position, and generate corresponding representative XML output. The quantities belonging to this mixed-record format are described in the ENSDF manual. Of the 16 ENSDF records in total, XML output has been successfully generated for 15 records. An XML-translation for the Comment Record is yet to be implemented; this will be considered in a separate phase of the overall translation effort. Continuation records, not yet implemented, will also be treated in a future phase of this work. Several examples are presented in this document to illustrate the XML schema and methods for handling the various ENSDF data types. However, the proposed nomenclature for the XML elements and attributes need not necessarily be considered as a fixed set of constructs. Indeed, better conventions may be suggested and a consensus can be achieved amongst the various groups of people interested in this project. The main purpose here is to present an initial phase of the translation effort to demonstrate the feasibility of interpreting ENSDF datasets and creating a representative XML-structured hierarchy for data storage.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary SAM Assessment

The System Analysis Module (SAM) is a modern system analysis tool being developed at Argonne National Laboratory (Argonne) for advanced non-LWR safety analysis. To assist NRC to assess SAM capabilities for advanced reactor safety analysis and licensing at the NRC, a series of verification and other standard tests (OSTs) are modeled in SAM and code simulation results are compared with available analytical results. This report documents the preliminary SAM assessment using a matrix of six test problems. Each test problem is further examined with different boundary conditions, system configurations, or modeling options. Although relatively simple, these tests cover the basic equation models, basic component models, and basic system level processes and phenomena that must be modeled for advanced reactor safety analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effluent Management Facility Stack Monitor Qualification: Assessment with Surrogate Stacks

Sampling and monitoring at the Waste Treatment and Immobilization Plant (WTP) Effluent Management Facility (EMF) exhaust is required to meet the regulatory criteria that governs stacks that may exceed the 0.1-millirem per year threshold limit given in Title 40 of the Code of Federal Regulations, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standard for Emissions of Radionuclides other than Radon from Department of Energy Facilities. As a result, the flow conditions and probe location must be within certain bounds as prescribed by the American National Standards Institute/Health Physics Society (ANSI/HPS) standard N13.1-1999. Compliance with the standard may be demonstrated by tests on the stack itself, or with a surrogate stack (i.e., a scale model or other geometrically similar stack). Pacific Northwest National Laboratory (PNNL) has performed scale model stack tests for 11 of the 20 emission points that are planned for the WTP. Additionally, PNNL has full scale stack results from Idaho National Laboratory and PNNL facility stacks to use as references. One or more WTP scale model stack results were expected to be appropriate as a surrogate stack to the EMF. This report describes the EMF stack monitoring location as well as an assessment of existing surrogate stacks used to qualify the EMF stack sampling location.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crack Growth Rate and Large Plate Demonstration of Chloride-induced Stress Corrosion Cracking in Spent Nuclear Fuel Storage Canisters

This report describes the body of work involving testing and analyses performed in FY18 and FY19 at the Savannah River National Laboratory and at Korea University to determine chloride-induced stress corrosion crack (CISCC) growth rates in weldments of austenitic stainless steel plate material. The primary work involved: several separate crack growth rate test campaigns with new testing setups using laboratory-scale corrosion specimens; analyses to estimate the stress intensity factors for flaws postulated to be present in the residual stress fields of axial and circumferential weldments in a prototypic dry storage canister; and establishment of a “large plate” (approximately 51×46 cm with thickness 16 mm and weight about 30 kg) CISCC test that uses a plate with a circumferential weldment harvested from the Sandia National Laboratories’ full-size mockup dry storage canister. The tests for crack growth rate were conducted on ASTM E1861 bolt-load compact tension specimens in a setup designed to allow initially dried salt deposits to deliquesce and infuse the brine to the crack front under conditions relevant to the canister storage environments (e.g., temperature and humidity). The crack growth rate test results matched previous experimental data in the open literature. These literature data had been compiled by SNL and EPRI to develop a temperature-dependent (K-insensitive) crack growth rate model to support flaw disposition in the ASME Boiler and Pressure Vessel Section XI Code Case N-860, “Examination Requirements and Acceptance Standards for Spent Nuclear Fuel Storage and Transportation Containment Systems.” The knowledge of the salt, temperature, humidity conditions for CISCC including the threshold stress intensity factor, $K_{ISCC}$, were used to setup the large plate test in which a set of partthrough- wall and through-wall electrical discharge machined (EDM) defects were positioned in the weld residual stress field of the welded plate material from the mockup canister. A salt solution was applied to this plate specimen with an air-brush spray, then dried, and then exposed to a constant 75% RH condition at an ambient room temperature of 22 °C. The salt loading and environmental condition is expected to be aggressive to cause CISCC. The visual results at the surface of the plate show corrosion product staining (brown rust appearance) but with no CISCC emanating from the machined notches after approximately 5 months exposure to date. The plate test will continue in FY20 and phased-array ultrasonic testing and other NDE techniques will be applied to identify and characterize CISCC that may emanate from the machined defects. The notches and any CISCC from them will be sectioned at the conclusion of the test to verify NDE characterization, and to develop effective through-wall crack growth rates from cracks that would likely be branched.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Discharge Permit-1845 Quarterly Status Report October 2019

Trichloroethene (TCE) and nitrate have been identified as constituents of concern in groundwater at the Sandia National Laboratories, New Mexico (SNL/NM) Technical Area (TA)-V Groundwater (TAVG) Area of Concern (AOC) based on detections above the U.S. Environmental Protection Agency (EPA) maximum contaminant levels in samples collected from monitoring wells. The maximum contaminant levels and the State of New Mexico drinking water standards, as specified in 20.6.2.3103 New Mexico Administrative Code (NMAC) for TCE and nitrate (as nitrogen) are 5 micrograms per liter (p,g/L) and 10 milligrams per liter (mg/L), respectively.

54 ENVIRONMENTAL SCIENCES↗

INL Environmental Monitoring Plan (DOE/ID-11088 Rev. 5)

This plan provides a high-level summary of environmental monitoring performed by various organizations within and around the Idaho National Laboratory (INL) Site as required by U.S. Department of Energy (DOE) Order 435.1, Radioactive Waste Management, and DOE Order 458.1, Radiation Protection of the Public and the Environment, Guide DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance, and in accordance with 40 Code of Federal Regulations (CFR) 61, National Emission Standards for Hazardous Air Pollutants. The purpose of these orders is to 1) implement sound stewardship practices that protect the air, water, land, and other natural and cultural resources that may be impacted by DOE operations, and 2) to establish standards and requirements for the operations of DOE and DOE contractors with respect to protection of the environment and members of the public against undue risk from radiation. This plan describes the organizations responsible for conducting environmental monitoring across the INL Site, the rationale for monitoring, the types of media being monitored, where the monitoring is conducted, and where monitoring results can be obtained. Detailed monitoring procedures, program plans, or other governing documents used by contractors or agencies to implement requirements are referenced in this plan. This plan covers all planned monitoring and environmental surveillance. Non-routine activities such as special research studies and characterization of individual sites for environmental restoration are outside the scope of this plan.

54 ENVIRONMENTAL SCIENCES↗

Investigation of Frozen Chemistry for Molten Salt Reactors (MSRs)

Understanding accident progression and the potential/conditions for fission product release from fuel is necessary to evaluate safety for any nuclear reactor system. Molten Salt Reactors (MSRs) under development need such analysis to support safety evaluations. Fission product chemistry specific to MSR concepts is a critical area that introduces distinct considerations relative to the current state-of-knowledge in reactor safety, primarily developed for water-moderated nuclear reactor systems. In Light Water Reactor (LWR) systems, it is necessary to capture the chemical interaction of fission products with the reactor evironment, containment and confinement systems. The overall effects at this point are relatively well understood for the purposes of performing safety evaluations. A key insight from LWR studies is that fission product chemical behavior can be reasonably captured by modeling approaches where the chemistry is "frozen". These modeling approaches assume that radionuclide reaction and speciation can be represented by chemical classes, each with characteristic transport behavior that is invariant under a broad range of thermochemical conditions. However, radionuclides can exhibit a range of behavior in the liquid salt-melt phase of the coolant used in MSRs. Radionuclides, salt, and the metal containment surfaces (i.e. pipes) can co-exist in dynamic equilibrium that could evolve with small system mass changes. A detailed investigation to the degree the equilibrium state can dynamically evolve with changes in the conditions of the molten salt mixture has not been previously conducted. It is currently not well understood where frozen chemistry assumptions are valid. Expanding the state-of-knowledge in this regard is relevant to better assessing the range of chemical effects that should be incorporated as part of MSR safety assessments. This investigation used the Oak Ridge Isotope GENeration (ORIGEN) module of the Standardized Computer-Analysis for Licensing Evaluation (SCALE) code to generate simulated radionuclide inventories for the MSR Experiment (MSRE) and then modeled reactor chemical speciation using the Molten Salt Thermodynamic Database – Thermochemical (MSTDB-TC) coupled with Thermochimica. The effect of composition variation during decay of fission product inventory in a molten salt over a period of 500 days prolonged post- at multiple temperatures was studied. Mass fractions for fluorine and berilium were varied in order to probe the effects of free fluorine control. Finally, speciation of fluoride reactors were showed by comparing MSRE readionuclide inventories with a FLiBe based molten salt breeder reactor (MSBR). The results showed that fission product mass change has little effect on phase mass changes and vapor pressures for fluoride species, but differ with varying carrier and fuel salt compositions. However, iodine species were found to have a vapor pressure not only dependent on temperature, but also the free fluorine potential, releasing iodine when the free fluorine potential is equal to the iodine inventory. This observation, however, arose under free fluorine potentials that are very unlikely to be realized in typical molten salt mixtures. Despite this observation, temperature was found to be the dominant parameter that drove phase change and fission product species vapor pressure. The results indicate that the current frozen chemistry approach is adequate for MSR analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Tracking System for Performance Monitoring

Benchmarking is essential for high-performance software development, particularly for monitoring performance across code iterations. This project focused on enhancing the benchmarking process for Lamellar, an asynchronous runtime for High-Performance Computing (HPC) systems developed at Pacific Northwest National Laboratory. Prior to this work, benchmark results were difficult to track and compare across code versions, presenting significant challenges in identifying performance regressions and long-term trends. The primary objective was to establish a systematic, reproducible approach for measuring performance and detecting regressions following code commits. Our methodology involved three key components: standardizing benchmark outputs, implementing data versioning, and developing analysis tools. We standardized the benchmark output format to JSON Line records containing specific fields (execution time, hardware specifications, and environmental variables). To address data management challenges, we evaluated several options and eventually chose a git repository dedicated to benchmark data. We developed a suite of Python tools that processed benchmark results, enriched them with metadata, and facilitated search in the repository. The resulting system enables more efficient filtering and comparison of performance metrics across commit histories, hardware configurations, and benchmark variants through a unified query interface. Our implementation reduces computational overhead by first checking for existing results through configuration matching before initiating new benchmark runs, thereby conserving resources. The system has been validated by Lamellar developers. It organizes results by benchmark type and build configurations for efficient retrieval. Future developments include a planned Large Language Model interface for predicting benchmark performance, incorporating the criterion package for statistical analysis, which will enable automated detection of statistically significant performance changes, and integration with continuous integration pipelines. Despite these enhancements being reserved for future work, this project has successfully provided the Lamellar development team with a framework for maintaining consistent performance standards and identifying optimization opportunities across workloads and hardware environments.

97 MATHEMATICS AND COMPUTING↗

Integrated Lift- and Wall-Force Closures in Computational Fluid Dynamics (CMFD)

In this report, we provide the necessary background to put this work in context and for a more detailed background, the reader is referred to CASL 2013 report. Central constraints on the design of LWRs are thermal-structural limits, e.g., maximum fuel pin temperature and maximum allowable working pressure in a pressure vessel. In both of these cases, the knowledge of the spatially and temporally varying two-phase flow is required to make accurate predictions as the distribution of both the phases have an impact on heat extraction as well as neutron moderation. Engineered two-phase flow systems have complex geometry and often high Reynolds numbers which increase the computational cost of an analysis, and generally make direct numerical simulations of the flow field impossible even on the fastest computers today. Consequently, a number of models which seek to reduce this computational cost have been created over the years. One of these called the two-fluid model has become the standard in three dimensional CFD (Computational Fluid Dynamics) codes and is and is also referred to as CMFD (Computational Multiphase Fluid Dynamics). The two-fluid model splits each conserved quantity into two fields, one for each phase that is treated as interspersed continua. Splitting one field into two requires additional interfacial closure relationships. In the two-fluid model, the momentum flux between the phases is governed by a number of these closure relationships. Generally, the net force on the dispersed phase is decomposed into inertial, added mass, buoyancy, drag, lift, and wall forces. In addition, there is a time-dependent Basset force, as well as turbulent dispersion effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2009

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada Test Site (NTS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the NLVF, an NTS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from sources such as medically or commercially used radionuclides. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration of each detected radionuclide at each of these locations is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2. At any one location, if multiple radionuclides are detected, then compliance with NESHAP is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2009, the potential dose from radiological emissions to air, resulting from both current and past NTS activities, at onsite compliance monitoring stations was a maximum of 1.69 mrem/yr, well below the 10 mrem/yr dose limit. Air sampling data collected at all six critical receptor stations had average concentrations of radioactivity that were a fraction of the CL values listed in Table 2 in Appendix E of 40 CFR 61. Concentrations ranged from less than 1 percent to a maximum of 17 percent of the allowed NESHAP limit. Because the nearest member of the public resides approximately 20 kilometers from potential release points on the NTS, concentrations at this location would be only a small fraction of that measured on the NTS. The potential dose to the public from NLVF emissions was also very low at 0.000044 mrem/yr, 230,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Genomic profiles of four novel cyanobacteria MAGs from Lake Vanda, Antarctica: insights into photosynthesis, cold tolerance, and the circadian clock

Cyanobacteria in polar environments face environmental challenges, including cold temperatures and extreme light seasonality with small diurnal variation, which has implications for polar circadian clocks. However, polar cyanobacteria remain underrepresented in available genomic data, and there are limited opportunities to study their genetic adaptations to these challenges. This paper presents four new Antarctic cyanobacteria metagenome-assembled genomes (MAGs) from microbial mats in Lake Vanda in the McMurdo Dry Valleys in Antarctica. The four MAGs were classified as Leptolyngbya sp. BulkMat.35, Pseudanabaenaceae cyanobacterium MP8IB2.15, Microcoleus sp. MP8IB2.171, and Leptolyngbyaceae cyanobacterium MP9P1.79. The MAGs contain 2.76 Mbp – 6.07 Mbp, and the bin completion ranges from 74.2–92.57%. Furthermore, the four cyanobacteria MAGs have average nucleotide identities (ANIs) under 90% with each other and under 77% with six existing polar cyanobacteria MAGs and genomes. This suggests that they are novel cyanobacteria and demonstrates that polar cyanobacteria genomes are underrepresented in reference databases and there is continued need for genome sequencing of polar cyanobacteria. Analyses of the four novel and six existing polar cyanobacteria MAGs and genomes demonstrate they have genes coding for various cold tolerance mechanisms and most standard circadian rhythm genes with the Leptolyngbya sp. BulkMat.35 and Leptolyngbyaceae cyanobacterium MP9P1.79 contained kaiB3, a divergent homolog of kaiB.

59 BASIC BIOLOGICAL SCIENCES↗

Multiphysics and Multiscale Modeling of Coupled Transport of Chloride Ions in Concrete

Chloride ions (Cl−)-induced corrosion is one of the main degradation mechanisms in reinforced concrete (RC) structures. In most situations, the degradation initiates with the transport of Cl− from the surface of the concrete towards the reinforcing steel. The accumulation of Cl− at the steel-concrete interface could initiate reinforcement corrosion once a threshold Cl− concentration is achieved. An accurate numerical model of the Cl− transport in concrete is required to predict the corrosion initiation in RC structures. However, existing numerical models lack a representation of the heterogenous concrete microstructure resulting from the varying environmental conditions and the indirect effect of time dependent temperature and relative humidity (RH) on the water adsorption and Cl− binding isotherms. In this study, a numerical model is developed to study the coupled transport of Cl− with heat, RH and oxygen (O2) into the concrete. The modeling of the concrete microstructure is performed using the Virtual Cement and Concrete Testing Laboratory (VCCTL) code developed by the U.S. National Institute of Standards and Technology (NIST). The concept of equivalent maturation time is utilized to eliminate the limitation of simulating concrete microstructure using VCCTL in specific environmental conditions such as adiabatic. Thus, a time-dependent concrete microstructure, which depends on the hydration reactions coupled with the temperature and RH of the environment, is achieved to study the Cl− transport. Additionally, Cl− binding isotherms, which are a function of the pH of the concrete pore solution, Cl− concentration, and weight fraction of mono-sulfate aluminate (AFm) and calcium-silicate-hydrate (C-S-H), obtained from an experimental study by the same authors are utilized to account for the Cl− binding of cement hydration products. The temperature dependent RH diffusion was considered to account for the transport of Cl− with moisture transport. The temperature and RH diffusion in the concrete domain, composite theory, and Cl− binding and water adsorption isotherms are used in combination, to estimate the ensuing Cl− diffusion field within the concrete. The coupled transport process of heat, RH, Cl−, and O2 is implemented in the Multiphysics Object-Oriented Simulation Environment (MOOSE) developed by the U.S. Idaho National Laboratory (INL). The model was verified and validated using data from multiple experimental studies with different concrete mixture proportions, curing durations, and environmental conditions. Additionally, a sensitivity analysis was performed to identify that the water-to-cement (w/c) ratio, the exposure duration, the boundary conditions: temperature, RH, surface Cl− concentration, Cl− diffusion coefficient in the capillary water, and the critical RH are the important parameters that govern the Cl− transport in RC structures. In a case study, the capabilities of the developed numerical model are demonstrated by studying the complex 2D diffusion of Cl− in a RC beam located in two different climatic regions: warm and humid weather in Galveston, Texas, and cold and dry weather in North Minnesota, Minnesota, subjected to time varying temperature, RH, and surface Cl− concentrations.

composite theory↗

Applying Information Theory to Design Optimal Filters for Photometric Redshifts

In this paper we apply ideas from information theory to create a method for the design of optimal filters for photometric redshift estimation. We show the method applied to a series of simple example filters in order to motivate an intuition for how photometric redshift estimators respond to the properties of photometric passbands. We then design a realistic set of six filters covering optical wavelengths that optimize photometric redshifts for z <= 2.3 and i < 25.3. We create a simulated catalog for these optimal filters and use our filters with a photometric redshift estimation code to show that we can improve the standard deviation of the photometric redshift error by 7.1% overall and improve outliers 9.9% over the standard filters proposed for the Large Synoptic Survey Telescope (LSST). We compare features of our optimal filters to the LSST and find that the LSST filters incorporate key features for optimal photometric redshift estimation. Finally, we describe how information theory can be applied to a range of optimization problems in astronomy.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of a Few Statistical Methods for Validation

Many institutions are using a sophisticated statistical methodology to validate criticality safety computer codes in compliance with the ANSI/ANS-8.1 and -8.24 standards (Ref. 1 and 2). Here a few similar statistical methods are compared, namely, the USLSTATS method developed by the Oak Ridge National Laboratory (ORNL), the Washington Safety Management Solutions (WSMS) method, and the GE USLSA method. These methods use the "trending analysis" technique, namely, the derivation of bias for an application is correlated to biases for benchmark experiments. The methods use regression techniques to identify trends. But they differ in choice and calculation of specific “regression parameters”.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transformable Rhodobacter strains, method for producing transformable Rhodobacter strains

The invention provides an organism for expressing foreign DNA, the organism engineered to accept standard DNA carriers. The genome of the organism codes for intracytoplasmic membranes and features an interruption in at least one of the genes coding for restriction enzymes. Further provided is a system for producing biological materials comprising: selecting a vehicle to carry DNA which codes for the biological materials; determining sites on the vehicle's DNA sequence susceptible to restriction enzyme cleavage; choosing an organism to accept the vehicle based on that organism not acting upon at least one of said vehicle's sites; engineering said vehicle to contain said DNA; thereby creating a synthetic vector; and causing the synthetic vector to enter the organism so as cause expression of said DNA.

59 BASIC BIOLOGICAL SCIENCES↗

A Conversation on Standard 90.1-2019

This article presents a roundtable discussion of the new edition of ASHRAE Standard 90.1-2019 Energy Standard for Buildings Except Low-Rise Residential Buildings. It discusses updates to the standard, challenges overcome, and thoughts about the trajectory of future versions of the standard. Contributors include leading members of the Standard 90.1 development committee.

ASHRAE Standard 90.1, ASHRAE, Energy Code↗

Recommendations for Distributed Energy Resource Patching

While computer systems, software applications, and operational technology (OT)/Industrial Control System (ICS) devices are regularly updated through automated and manual processes, there are several unique challenges associated with distributed energy resource (DER) patching. Millions of DER devices from dozens of vendors have been deployed in home, corporate, and utility network environments that may or may not be internet-connected. These devices make up a growing portion of the electric power critical infrastructure system and are expected to operate for decades. During that operational period, it is anticipated that critical and noncritical firmware patches will be regularly created to improve DER functional capabilities or repair security deficiencies in the equipment. The SunSpec/Sandia DER Cybersecurity Workgroup created a Patching Subgroup to investigate appropriate recommendations for the DER patching, holding fortnightly meetings for more than nine months. The group focused on DER equipment, but the observations and recommendations contained in this report also apply to DERMS tools and other OT equipment used in the end-to-end DER communication environment. The group found there were many standards and guides that discuss firmware lifecycles, patch and asset management, and code-signing implementations, but did not singularly cover the needs of the DER industry. This report collates best practices from these standards organizations and establishes a set of best practices that may be used as a basis for future national or international patching guides or standards.

97 MATHEMATICS AND COMPUTING↗

Hydrogen Concentration in the Inner-Most Container within a Pencil Tank Overpack Packaged in a Standard Waste Box Package

A set of steady state diffusion flow equations, for the hydrogen diffusion from one bag to the next bag (or one plastic waste container to another), within a set of nested waste bags (or nested waste containers), are developed and presented. The input data is then presented and justified. Inputting the data for each volume and solving these equations yields the steady state hydrogen concentration in each volume. The input data (permeability of the bag surface and closure, dimensions and hydrogen generation rate) and equations are analyzed to obtain the hydrogen concentrations in the innermost container for a set of containers which are analyzed for the TRUCON code for the general waste containers and the TRUCON code for the Pencil Tank Overpacks (PTO) in a Standard Waste Box (SWB).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗