Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “baseline estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

The Helios radio astronomy experiment

Radio bursts traveling between the Sun and the Earth were tracked by radio astronomy experiments on Helios 1 and 2. A relatively short dipole antenna with a well-defined toroidal reception pattern was flown. The antenna spins in the ecliptic at 60.3 rpm and 2 frequencies are measured in each revolution. The signal analysis determines the strength of the signal, the direction of the source in the ecliptic, and the degree of modulation, and estimates source size. The experiments provide three-dimensional direction finding in space. They extend the radio frequency window beyond what is observable on Earth, and offer a long triangulation baseline.

Kayser, S.↗

Space Station Freedom on-orbit crew time availability - A limited resource

Because of the enormity, complexity, and duration of the Space Station Freedom (SSF) project, the available crew time is at a premium. This paper discusses the methodology for determining, early in the program, estimates of crew time which will be available within pressurized areas of intravehicular activity, from the First Element Launch (FEL) throughout the lifetime of the SSF. The methodology utilizes the baseline assembly sequence (November 1989) as a guideline. The total hours provided are categorized by periods, where a period is comprised of the time between two major SSF Program assembly milestones; e.g., FEL to Man Tended Capability (MTS), MTS to Permanently Manned Capability (PMC), or PMC to Assembly Complete (AC). After AC, total available crew time is presented on a yearly basis.

Garegnani, Jerry J.↗

Observation model and parameter partials for the JPL VLBI parameter estimation software MODEST, 19 94

This report is a revision of the document Observation Model and Parameter Partials for the JPL VLBI Parameter Estimation Software 'MODEST'---1991, dated August 1, 1991. It supersedes that document and its four previous versions (1983, 1985, 1986, and 1987). A number of aspects of the very long baseline interferometry (VLBI) model were improved from 1991 to 1994. Treatment of tidal effects is extended to model the effects of ocean tides on universal time and polar motion (UTPM), including a default model for nearly diurnal and semidiurnal ocean tidal UTPM variations, and partial derivatives for all (solid and ocean) tidal UTPM amplitudes. The time-honored 'K(sub 1) correction' for solid earth tides has been extended to include analogous frequency-dependent response of five tidal components. Partials of ocean loading amplitudes are now supplied. The Zhu-Mathews-Oceans-Anisotropy (ZMOA) 1990-2 and Kinoshita-Souchay models of nutation are now two of the modeling choices to replace the increasingly inadequate 1980 International Astronomical Union (IAU) nutation series. A rudimentary model of antenna thermal expansion is provided. Two more troposphere mapping functions have been added to the repertoire. Finally, corrections among VLBI observations via the model of Treuhaft and lanyi improve modeling of the dynamic troposphere. A number of minor misprints in Rev. 4 have been corrected.

Sovers, O. J.↗

System Noise Technology Roadmaps for a Transonic Truss-Braced Wing and Peer Conventional Configuration

A system noise assessment is performed for a Boeing-designed Transonic Truss-Braced Wing, resized using NASA tools in order to estimate the performance of the configuration relative to NASA noise goals. For comparison, a conventional configuration with comparable mission requirements, technology assumptions, and design assumptions is also assessed. Following the baseline noise assessments, a noise reduction technology roadmap is developed from technologies expected to mature to an appropriate technology readiness level by the targeted entry into service date. Noise prediction of both baseline configurations shows a 4.7 EPNdB cumulative certification advantage for the Transonic Truss-Braced Wing. Both configurations fall short of the mid term NASA noise goal, even with application of the noise reduction technologies in the roadmap. The roadmap provides 7.3 EPNdB of noise reduction for the conventional configuration and 7.8 EPNdB for the Transonic Truss-Braced Wing.

system noise assessment↗

Outyear Budgeting Tool

OBTool performs the following: • Consistent method and tool to develop/estimate fiscal year (FY) 2010 and outyear budget/estimates • Maintain configuration control on resource rates and changes to outyear budget estimates, while allowing for accessibility, accountability, and tracking shared access between program managers, facility managers (FMs), project managers (PMs), cost account managers (CAMs), and project controls engineers (PCEs) • Consistency in budget estimating methodology, including scope, requirements, basis of estimates, resources, activities, escalation, and presentation of documentation in tasks and execution plans and reports • Ability to sync (i.e. export) and import data into Primavera and Cobra to the lifecycle baseline file

Carlos Castillo, Jerel Nelson↗

Power systems simulations of the western United States region.

This report documents a part of a broad assessment of energy-water-related issues in the western United States. The full analysis involved three Department of Energy national laboratories: Argonne National Laboratory, Los Alamos National Laboratory, and Sandia National Laboratories. Argonne's objective in the overall project was to develop a regional power sector expansion forecast and a detailed unit-level operational (dispatch) analysis. With these two major analysis components, Argonne estimated current and future freshwater withdrawals and consumption related to the operation of U.S. thermal-electric power plants in the Western Electricity Coordinating Council (WECC) region for the period 2005-2025. Water is withdrawn and used primarily for cooling but also for environmental control, such as sulfur scrubbers. The current scope of the analysis included three scenarios: (1) Baseline scenario as a benchmark for assessing the adequacy and cost-effectiveness of water conservation options and strategies, (2) High nuclear scenario, and (3) High renewables scenario. Baseline projections are consistent with forecasts made by the WECC and the Energy Information Administration (EIA) in its Annual Energy Outlook (AEO) (EIA 2006a). Water conservation scenarios are currently limited to two development alternatives that focus heavily on constructing new generating facilities with zero water consumption. These technologies include wind farms and nuclear power plants with dry cooling. Additional water conservation scenarios and estimates of water use associated with fuel or resource extraction and processing will be developed in follow-on analyses.

17 WIND ENERGY↗

Setting a baseline for Integrated Landscape Design: Cost and risk assessment in herbaceous feedstock supply chains

The literature on bioenergy has pointed out that financial risks and limited performance benchmarks are leading barriers to wide-spread industry expansion. The purpose of this paper is to document a baseline cost and risk assessment from the perspective of biorefinery management for two herbaceous feedstocks, switchgrass and corn stover, in an application of Integrated Landscape Design (ILD). Integrating energy crops into row crops has attracted considerable attention leading to a variety of ways to implement ILD. However, variation in production conditions, different methods of implementing unit operations, and technology performance variability are among many factors leading to financial risk facing biorefineries from feedstock supply based on ILD. Utilizing data from field-based trials on switchgrass and corn stover in Virginia and Iowa in the United States, we estimate feedstock logistics cost and characterize it by a distribution of potential outcomes. The results show that, across fields included in the study, logistics cost for switchgrass vary from 73 per Mg to 171 per Mg. For corn stover, the inter-field variation in cost ranges from 83 per Mg to 105 per Mg. Results for intra-field uncertainty show that the cost for switchgrass ranges from 58 per Mg to 74 per Mg, and for corn stover they range from 50 per Mg to 65 per Mg. Furthermore, these results inform a baseline from which improvements in ILD can be compared, and provide biorefinery management with a starting point for cost and risk estimates of feedstock from ILD.

09 BIOMASS FUELS↗

Possible Methods to Estimate Core Location in a Beyond-Design-Basis Accident at a GE BWR with a Mark I Containment Stucture

It is difficult to track to the location of a melted core in a GE BWR with Mark I containment during a beyond-design-basis accident. The Cooper Nuclear Station provided a baseline of normal material distributions and shielding configurations for the GE BWR with Mark I containment. Starting with source terms for a design-basis accident, methods and remote observation points were investigated to allow tracking of a melted core during a beyond-design-basis accident. The design of the GE BWR with Mark-I containment highlights an amazing poverty of expectations regarding a common mode failure of all reactor core cooling systems resulting in a beyond-design-basis accident from the simple loss of electric power. This design is shown in Figure 1. The station blackout accident scenario has been consistently identified as the leading contributor to calculated probabilities for core damage. While NRC-approved models and calculations provide guidance for indirect methods to assess core damage during a beyond-design-basis loss-of-coolant accident (LOCA), there appears to be no established method to track the location of the core directly should the LOCA include a degree of fuel melt. We came to the conclusion that - starting with detailed calculations which estimate the release and movement of gaseous and soluble fission products from the fuel - selected dose readings in specific rooms of the reactor building should allow the location of the core to be verified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nadir Pressure Exposure Estimates for the Existing Turbines at McNary Dam

This report documents a numerical modeling study conducted to assess the pressure environment and relative biological performance of the existing turbine runner design at the U.S. Army Corps of Engineers (USACE) McNary Dam to establish a baseline for comparison to planned replacement runner designs. Computational fluid dynamics (CFD) models of the turbine unit constructed for this study were analyzed using a streamtrace-based technique called the Biological Performance Assessment (BioPA), which was developed at the Pacific Northwest National Laboratory (PNNL).

42 ENGINEERING↗

Estimate of the Distribution of Solids Within Mixed Hanford Double-Shell Tank AZ-101: Implications for AY-102

This paper describes the current level of understanding of the suspension of solids in Hanford double-shell waste tanks while being mixed with the baseline configuration of two 300-horsepower mixer pumps. A mixer pump test conducted in Tank AZ-101 during fiscal year 2000 provided the basis for this understanding. Information gaps must be filled to demonstrate the capability of the baseline feed delivery system to effectively mix, sample, and deliver double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for vitrification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systematic Independent Validation of Inner Heliospheric Models

This presentation is the first in a series which will provide independent validation of community models of the outer corona and inner heliosphere. In this work we establish a set of measures to be used in validating this group of models. We use these procedures to generate a comprehensive set of results from the Wang- Sheeley-Arge (WSA) model which will be used as a baseline, or reference, against which to compare all other models. We also run a test of the validation procedures by applying them to a small set of results produced by the ENLIL Magnetohydrodynamic (MHD) model. In future presentations we will validate other models currently hosted by the Community Coordinated Modeling Center(CCMC), including a comprehensive validation of the ENLIL model. The Wang-Sheeley-Arge (WSA) model is widely used to model the Solar wind, and is used by a number of agencies to predict Solar wind conditions at Earth as much as four days into the future. Because it is so important to both the research and space weather forecasting communities, it is essential that its performance be measured systematically, and independently. In this paper we offer just such an independent and systematic validation. We report skill scores for the model's predictions of wind speed and IMF polarity for a large set of Carrington rotations. The model was run in all its routinely used configurations. It ingests line of sight magnetograms. For this study we generated model results for monthly magnetograms from the National Solar Observatory (SOLIS), Mount Wilson Observatory and the GONG network, spanning the Carrington rotation range from 1650 to 2068. We compare the influence of the different magnetogram sources, performance at quiet and active times, and estimate the effect of different empirical wind speed tunings. We also consider the ability of the WSA model to identify sharp transitions in wind speed from slow to fast wind. These results will serve as a baseline against which to compare future versions of the model

MacNeice, P. J.↗

Modeling the Air Quality Impacts of Future Energy Scenarios

Many greenhouse gas (GHG) emission reduction measures achieve simultaneous reductions in air pollutants. Human-Earth system models can estimate such emission changes in the energy system but using them in chemistry-transport models (CTMs) to study their air quality impacts involves resource-intensive emissions processing. This is greatly simplified by an emissions scaling approach linking state-level emissions estimated by a human-Earth system model to a CTM. A scenario continuing pre-2022 energy policy in the U.S. to 2050 shows widespread air quality improvements over the 2015 baseline from SO 2 and NO x emission reductions of 50–80% from electricity generation and light-duty vehicles. Scenarios of GHG mitigation and vehicle electrification at the state and national level add further benefits. However, PM 2.5 increases from increased use of wood heating and bioenergy suggest that additional PM 2.5 management may be needed when using biofuels. In conclusion, this approach helps assess multiple future energy scenarios efficiently without sacrificing chemical detail in the air quality simulations.

air quality↗

Sweeping Jet Film Cooling at High Blowing Ratio on a Turbine Vane

Abstract Experimental and numerical investigations were performed to study the effects of high blowing ratios and high freestream turbulence on sweeping jet film cooling. Experiments were conducted on a nozzle guide vane suction surface in a low-speed linear cascade at a range of blowing ratios of 0.5–3.5 and freestream turbulence of 0.6% and 14.3%. Infrared thermography was used to estimate the adiabatic cooling effectiveness. Thermal field and boundary layer measurements were conducted at a cross-plane at x/D = 12 downstream of the hole exit. Results were compared with a baseline 777-shaped hole and showed that the sweeping jet hole has improved cooling effectiveness at high blowing ratios (M > 1). The thermal field data revealed that the coolant separates from the surface at high blowing ratios for the 777-shaped hole while the coolant remains attached for the sweeping jet hole. Boundary layer measurements further confirmed that due to the sweeping motion of the jet, the effective jet momentum of the sweeping jet hole remains much lower than that of a 777-shaped hole. Thus, the coolant remains closer to the wall even at high blowing ratios. Large Eddy simulations (LES) were performed for both the sweeping jet and 777-shaped hole to evaluate the interaction between the coolant jet and the freestream in the near hole regions. Results showed that 777-shaped hole has a strong jetting at high blowing ratio that originates inside the hole breakout edges thus causing the jet to blow-off from the surface. In contrast, the sweeping jet does not show this behavior due to its internal geometry and flapping motion of the jet.

Engineering↗

Advanced High Temperature Reactor Systems and Economic Analysis

The Advanced High Temperature Reactor (AHTR) is a design concept for a large-output [3400 MW(t)] fluoride-salt-cooled high-temperature reactor (FHR). FHRs, by definition, feature low-pressure liquid fluoride salt cooling, coated-particle fuel, a high-temperature power cycle, and fully passive decay heat rejection. The AHTR's large thermal output enables direct comparison of its performance and requirements with other high output reactor concepts. As high-temperature plants, FHRs can support either high-efficiency electricity generation or industrial process heat production. The AHTR analysis presented in this report is limited to the electricity generation mission. FHRs, in principle, have the potential to be low-cost electricity producers while maintaining full passive safety. However, no FHR has been built, and no FHR design has reached the stage of maturity where realistic economic analysis can be performed. The system design effort described in this report represents early steps along the design path toward being able to predict the cost and performance characteristics of the AHTR as well as toward being able to identify the technology developments necessary to build an FHR power plant. While FHRs represent a distinct reactor class, they inherit desirable attributes from other thermal power plants whose characteristics can be studied to provide general guidance on plant configuration, anticipated performance, and costs. Molten salt reactors provide experience on the materials, procedures, and components necessary to use liquid fluoride salts. Liquid metal reactors provide design experience on using low-pressure liquid coolants, passive decay heat removal, and hot refueling. High temperature gas-cooled reactors provide experience with coated particle fuel and graphite components. Light water reactors (LWRs) show the potentials of transparent, high-heat capacity coolants with low chemical reactivity. Modern coal-fired power plants provide design experience with advanced supercritical-water power cycles. The current design activities build upon a series of small-scale efforts over the past decade to evaluate and describe the features and technology variants of FHRs. Key prior concept evaluation reports include the SmAHTR preconceptual design report,1 the PB-AHTR preconceptual design, and the series of early phase AHTR evaluations performed from 2004 to 2006. This report provides a power plant-focused description of the current state of the AHTR. The report includes descriptions and sizes of the major heat transport and power generation components. Component configuration and sizing are based upon early phase AHTR plant thermal hydraulic models. The report also provides a top-down AHTR comparative economic analysis. A commercially available advanced supercritical water-based power cycle was selected as the baseline AHTR power generation cycle both due to its superior performance and to enable more realistic economic analysis. The AHTR system design, however, has several remaining gaps, and the plant cost estimates consequently have substantial remaining uncertainty. For example, the enriched lithium required for the primary coolant cannot currently be produced on the required scale at reasonable cost, and the necessary core structural ceramics do not currently exist in a nuclear power qualified form. The report begins with an overview of the current, early phase, design of the AHTR plant. Only a limited amount of information is included about the core and vessel as the core design and refueling options are the subject of a companion report. The general layout of an AHTR system and site showing the relationship of the major facilities is then provided. Next is a comparative evaluation of the AHTR anticipated performance and costs. Finally, the major system design efforts necessary to bring the AHTR design to a pre-conceptual level are then presented.

Holcomb, David Eugene↗

Reflector Technology Development and System Design for Concentrating Solar Power Technologies

Alcoa began this program in March of 2008 with the goal of developing and validating an advanced CSP trough design to lower the levelized cost of energy (LCOE) as compared to existing glass based, space-frame trough technology. In addition to showing a pathway to a significant LCOE reduction, Alcoa also desired to create US jobs to support the emerging CSP industry. Alcoa's objective during Phase I: Concept Feasibility was to provide the DOE with a design approach that demonstrates significant overall system cost savings without sacrificing performance. Phase I consisted of two major tasks; reflector surface development and system concept development. Two specific reflective surface technologies were investigated, silver metallized lamination, and thin film deposition both applied on an aluminum substrate. Alcoa prepared samples; performed test validation internally; and provided samples to the NREL for full-spectrum reflectivity measurements. The final objective was to report reflectivity at t = 0 and the latest durability results as of the completion of Phase 1. The target criteria for reflectance and durability were as follows: (1) initial (t = 0), hemispherical reflectance >93%, (2) initial spectral reflectance >90% for 25-mrad reading and >87% for 7-mrad reading, and (3) predicted 20 year durability of less than 5% optical performance drop. While the results of the reflective development activities were promising, Alcoa was unable to down-select on a reflective technology that met the target criteria. Given the progress and potential of both silver film and thin film technologies, Alcoa continued reflector surface development activities in Phase II. The Phase I concept development activities began with acquiring baseline CSP system information from both CSP Services and the DOE. This information was used as the basis to develop conceptual designs through ideation sessions. The concepts were evaluated based on estimated cost and high-level structural performance. The target criteria for the concept development was to achieve a solar field cost savings of 25%-50% thereby meeting or exceeding the DOE solar field cost savings target of $\$$350/m 2 . After evaluating various structural design approaches, Alcoa down-selected to a monocoque, dubbed Wing Box, design that utilizes the reflective surface as a structural, load carrying member. The cost and performance potential of the Wing Box concept was developed via initial finite element analysis (FEA) and cost modeling. The structural members were sized through material utilization modeling when subjected to representative loading conditions including wind loading. Cost modeling was utilized to refine potential manufacturing techniques that could be employed to manufacture the structural members. Alcoa concluded that an aluminum intensive collector design can achieve significant cost savings without sacrificing performance. Based on the cost saving potential of this Concept Feasibility study, Alcoa recommended further validation of this CSP approach through the execution of Phase II: Design and Prototype Development. Alcoa Phase II objective was to provide the DOE with a validated CSP trough design that demonstrates significant overall system cost savings without sacrificing performance. Phase II consisted of three major tasks; Detail System Design, Prototype Build, and System Validation. Additionally, the reflector surface development that began in Phase I was continued in Phase II. After further development work, Alcoa was unable to develop a reflective technology that demonstrated significant performance or cost benefits compared to commercially available CSP reflective products. After considering other commercially available reflective surfaces, Alcoa selected Alano's MIRO-SUN product for use on the full scale prototype. Although MIRO-SUN has a lower specular reflectivity compared to other options, its durability in terms of handling, cleaning, and long-term reflectivity was deemed the most important attribute to successfully validate Alcoa's advanced trough architecture. To validate the performance of the Wing Box trough, a 6 meter aperture by 14 meter long prototype trough was built. For ease of shipping to and assembly at NREL's test facility, the prototype was fabricated in two half modules and joined along the centerline to create the Wing Box trough. The trough components were designed to achieve high precision of the reflective surface while leveraging high volume manufacturing and assembly techniques.

14 SOLAR ENERGY↗

STP/TAMU/INL Collaboration Update: LWRS Risk-Informed Safety Margin Characterization (RISMC) Lead

Present a preliminary RISMC model, including plant model interfaces for Best Estimate Plus Uncertainty Loss-Of-Coolant Accident analysis using riskinformed analysis tools. Analysis results for a coupled core design, fuel/clad and systems analysis framework (LOTUS) will be presented for existing baseline codes (RELAP5-3D, FRAPCON) to Large Break Loss-Of-Coolant Accident scenarios

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗