At least 1,117 records · Page 62

A Mechanism for Precise Linear and Angular Adjustment Utilizing Flexures

This paper describes the design and development of a mechanism for precise linear and angular adjustment. This work was in support of the development of a mechanical extensometer for biaxial strain measurement. A compact mechanism was required which would allow angular adjustments about perpendicular axes with better than 10(exp -3) degree resolution. The approach adopted was first to develop a means of precise linear adjustment. To this end, a mechanism based on the toggle principle was built with inexpensive and easily manufactured parts. A detailed evaluation showed that the resolution of the mechanism was better than 1 micron and that adjustments made by using the device were repeatable. In the second stage of this work, the linear adjustment mechanisms were used in conjunction with a simple arrangement of flexural pivots and attachment blocks to provide the required angular adjustments. A series of experiments conducted with an autocollimator showed that the resolution of the mechanisms was better than 10(exp -3) degrees. Also, the mechanism met all requirements regarding size, weight, and mechanical simplicity. Attempts to use the mechanism in conjunction with the biaxial extensometer under development proved unsuccessful. Any form of in situ adjustment was found to cause erratic changes in instrument output. These changes were due to problems with the suspension system. However, the subject mechanism performed well in its own right and appeared to have potential for use in other applications. One important advantage of flexure based mechanisms is that they can be designed to operate independently of screw threads. This raises the possibility that they can be used for precise linear and angular adjustment in a space environment.

Ellis, J. R.↗

Observations of energetic electrons /E no less than about 200 keV/ in the earth's magnetotail - Plasma sheet and fireball observations

An earlier paper by the authors (1976) has reported on energetic electron anisotropies observed in conjunction with the acceleration regions identified by Frank et al., (1976). The present paper gives more detailed analyses of observations in the distant plasma sheet, including specific features of intensities, energy spectra, and pitch angle distributions of the very energetic electrons associated with intense plasma particle events, with energies ranging between 50 eV and 45 keV, detected with an electron/isotope spectrometer aboard the earth-orbiting spacecraft Imp 8. Two domains are considered: the plasma sheet and the regions near and within the localized magnetotail acceleration regions known as the fireball regions. The instrumentation used offered a number of observational advantages over many previous studies, including inherently low background, large geometric factors, excellent species identification, good angular distribution measurement capability, and availability of high resolution of differential intensities.

Baker, D. N.↗

ISEE 3 observations during a plasma sheet encounter at 140 earth radii - Evidence for enhancement of reconnection at the distant neutral line

A plasma sheet encounter of the ISEE-3 spacecraft in the distant tail at 140 earth radii on March 20, 1983 is studied using magnetic field, energetic particle, and plasma electron data sets. The H-component magnetograms from auroral magnetometer stations, intensity-time profiles, high resolution magnetic field measurements, and electron and proton angular distributions are analyzed. The dynamics of the plasma sheet displayed by the strong tailward and earthward directed ion beams, large northward and southward magnetic fields excursions, and short tailward and earthward plasma flows are described.

Scholer, M.↗

SOFIA: Stratospheric Observatory for Infrared Astronomy

SOFIA will be a three meter class telescope operating in a Boeing 747, offering astronomers routine access to infrared wavelengths unavailable from the ground, and with the means to observe transient astronomical events from anywhere in the world. The concept is based on 15 years of experience with NASA's Kuiper Airborne Observatory (KAO), which SOFIA will replace in the mid 1990's. SOFIA's wavelength range covers nearly four decades of the electromagnetic spectrum: from the visible, throughout the infrared and submillimeter, to the microwave region. Relative to the KAO, SOFIA will be roughly ten times more sensitive for compact sources, enabling observations of fainter objects and measurements at higher spectral resolution. Also, it will have three times the angular resolving power for wavelengths greater than 30 microns, permitting more detailed imaging at far infrared wavelengths.

Erickson, E. F.↗

Predicting Stellar Angular Sizes

Reliable prediction of stellar diameters, particularly angular diameters, is a useful and necessary tool for the increasing number of milliarcsecond resolution studies being carried out in the astronomical community.

interferometry angular sizes stars↗

A mechanism for precise linear and angular adjustment utilizing flexures

The design and development of a mechanism for precise linear and angular adjustment is described. This work was in support of the development of a mechanical extensometer for biaxial strain measurement. A compact mechanism was required which would allow angular adjustments about perpendicular axes with better than 0.001 degree resolution. The approach adopted was first to develop a means of precise linear adjustment. To this end, a mechanism based on the toggle principle was built with inexpensive and easily manufactured parts. A detailed evaluation showed that the resolution of the mechanism was better than 1 micron and that adjustments made by using the device were repeatable. In the second stage of this work, the linear adjustment mechanisms were used in conjunction with a simple arrangement of flexural pivots and attachment blocks to provide the required angular adjustments. Attempts to use the mechanism in conjunction with the biaxial extensometer under development proved unsuccessful. Any form of in stitu adjustment was found to cause erratic changes in instrument output. These changes were due to problems with the suspension system. However, the subject mechanism performed well in its own right and appeared to have potential for use in other applications.

Ellis, J. R.↗

Enhanced resolution particle size distributions by multiple angle photon correlation spectroscopy

Photon correlation spectroscopy (PCS) has become a method of choice for measuring submicrometer particles. It is capable of rapid, accurate measurements of mean particle size. Since the measurements are nonperturbing, it is ideal for monitoring systems undergoing dynamic changes. Despite its widespread acceptance, the information content of PCS measurements for particle size distributions is low and provides limited resolution. A method is presented whereby PCS measurements made at several scattering angles plus the angular distribution of light scattered from the particles are combined in a single simultaneous analysis to effect an enhanced resolution particle size distribution. The efficacy of the method is assessed by recovering size distributions from computer simulated data and by comparisons of conventional PCS measurements of polystyrene spheres with those made by the new method.

Bott, Steven E.↗

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

The Spectral Information Based Angular Correction Methodology for Satellite Intercalibration Applications

Satellite inter-calibration often requires collocated observations with minimized discrepancies in sun-view angles, observation times, and sensor characteristics. The collocation criteria directly impact achievable inter-calibration accuracy. Addressing potential angular mismatches in inter-calibration samples is critical but not as fully recognized and addressed as spatial-temporal mismatches in many studies. To achieve high-accuracy corrections for errors due to mismatched sun-view geometry angles, an angular correction algorithm has been developed for the Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission. This algorithm uses spectral correlation relationships to estimate differences in spectral radiances measured at different angles. This methodology can be extended for inter-calibrations between sensors measuring band radiances across a broad spectral region. We demonstrate its application in reducing angular mismatch errors between collocated measurements of multi-spectral imaging sensors, using the inter-calibration between the Moderate Resolution Imaging Spectrometer (MODIS) and the Visible Infrared Imaging Radiometer Suite (VIIRS) as an example. The angular correction allows for more relaxed collocation criteria so that more satellite-based inter-calibration samples can be utilized. Furthermore, implementing the angular correction algorithm improves inter-calibration accuracy in applications where angular mismatch errors have not been explicitly addressed previously.

Wan Wu↗

Digital plus analog output encoder

The disclosed encoder is adapted to produce both digital and analog output signals corresponding to the angular position of a rotary shaft, or the position of any other movable member. The digital signals comprise a series of binary signals constituting a multidigit code word which defines the angular position of the shaft with a degree of resolution which depends upon the number of digits in the code word. The basic binary signals are produced by photocells actuated by a series of binary tracks on a code disc or member. The analog signals are in the form of a series of ramp signals which are related in length to the least significant bit of the digital code word. The analog signals are derived from sine and cosine tracks on the code disc.

Hafle, R. S.↗

Radar Polarimeter Measures Orientations Of Retroreflectors

Polarization signatures of targets compared with known signatures at known angles. Experiments demonstrated use of radar polarimetry to measure orientation of retroreflective target, even though target much smaller than resolution element of radar. Technique based on comparison of angular dependencies of measured and theoretically derived polarization signatures of target. Polarization signature also used to identify target. Tilt of reflector inferred by finding angle minimizing measure of difference between theoretical and measured radar cross sections of reflector.

Zebker, H. A.↗

An optical systems analysis approach to image resampling

All types of image registration require some type of resampling, either during the registration or as a final step in the registration process. Thus the image(s) must be regridded into a spatially uniform, or angularly uniform, coordinate system with some pre-defined resolution. Frequently the ending resolution is not the resolution at which the data was observed with. The registration algorithm designer and end product user are presented with a multitude of possible resampling methods each of which modify the spatial frequency content of the data in some way. The purpose of this paper is threefold: (1) to show how an imaging system modifies the scene from an end to end optical systems analysis approach, (2) to develop a generalized resampling model, and (3) empirically apply the model to simulated radiometric scene data and tabulate the results. A Hanning windowed sinc interpolator method will be developed based upon the optical characterization of the system. It will be discussed in terms of the effects and limitations of sampling, aliasing, spectral leakage, and computational complexity. Simulated radiometric scene data will be used to demonstrate each of the algorithms. A high resolution scene will be "grown" using a fractal growth algorithm based on mid-point recursion techniques. The result scene data will be convolved with a point spread function representing the optical response. The resultant scene will be convolved with the detection systems response and subsampled to the desired resolution. The resultant data product will be subsequently resampled to the correct grid using the Hanning windowed sinc interpolator and the results and errors tabulated and discussed.

Lyon, Richard G.↗

Angular Distribution Models for Top-of-Atmosphere Radiative Flux Estimation from the Clouds and the Earth's Radiant Energy System Instrument on the Tropical Rainfall Measuring Mission Satellite: Methodology - Part 1

Clouds and the Earth s Radiant Energy System (CERES) investigates the critical role that clouds and aerosols play in modulating the radiative energy flow within the Earth-atmosphere system. CERES builds upon the foundation laid by previous missions, such as the Earth Radiation Budget Experiment, to provide highly accurate top-of-atmosphere (TOA) radiative fluxes together with coincident cloud and aerosol properties inferred from high-resolution imager measurements. This paper describes the method used to construct empirical angular distribution models (ADMs) for estimating shortwave, longwave, and window TOA radiative fluxes from CERES radiance measurements on board the Tropical Rainfall Measuring Mission satellite. To construct the ADMs, multiangle CERES measurements are combined with coincident high-resolution Visible Infrared Scanner measurements and meteorological parameters from the European Centre for Medium-Range Weather Forecasts data assimilation product. The ADMs are stratified by scene types defined by parameters that have a strong influence on the angular dependence of Earth's radiation field at the TOA. Examples of how the new CERES ADMs depend upon the imager-based parameters are provided together with comparisons with existing models.

Loeb, N. G.↗

A satellite-borne ion mass spectrometer for the energy range 0 to 16 keV

The Ion Composition Experiment (ICE) on GEOS represents the first comprehensive attempt to measure the positive ion composition at high altitudes in the magnetosphere. Due to the heterogeneous nature of the magnetospheric plasma a novel mass spectrometer has been developed to cover the mass per charge range from H-1(+) to beyond Ba-138(+) and the energy per charge range from 0 to 16 keV/e. The ICE consists primarily of a cylindrical electrostatic analyzer followed by a curved analyzer incorporating crossed magnetic and electric fields. This combination has limited angular and energy focusing properties, but it maintains a mass resolution of about 4 over a wide range in energy and mass, sufficient for the objectives of measuring plasmas of both solar and terrestrial origin. High sensitivity and low background should allow measurements of rarer ion constituents down to flux levels of 0.01 ions/sq cm sec ster eV. A sophisticated electronics combined with powerful ground computer and telecommand systems allow for very efficient scanning of the mass-energy space.

Balsiger, H.↗

Performance analysis of the multichannel astrometric photometer

It has been proposed that extrasolar planetary systems may be observed if perturbations in star position due to the orbit of Jupiter-type planets could be detected. To see this motion, high accuracy measurements of 0.01 milliarcsecond are required over a relatively large field of view. Techniques using a moving Ronchi grating have been proposed for this application and have been successful in ground-based lower resolution tests. The method may have application to other precision angular measurement problems. This paper explores the theoretical description of the method, considers certain of the error sources, and presents a preliminary calculation of the performance which may be achieved.

Huang, Chunsheng↗

Cloud, dust, and ozone vertical profiles from solar occultation measurements: Implications for dynamics

An instrument was designed for solar occultation measurements of the martian atmosphere from the Phobos spacecraft. It was composed of three different dispersive systems working in the ultraviolet (UV: 0.22-0.32 microns) for the measurement of O3 and aerosols, in the near infrared (NIR: 0.76 microns, 0.94 microns) for the detection of O2 and H2O, and in the infrared (IR: 1.9 microns, 3.7 microns) where CO2 and H2O were measured. A detailed description of the instrument may be found in the special issue of Nature. Its principle objective is to measure from the Phobos orbit the spectrum of the Sun, modified by atmospheric extinction, during sunset. The UV-NIR spot has an angular diameter of 1 arcmin, or approximately 3 km vertical resolution, and is located near the center of the solar disk. The IR field is about twice as large and its line of sight is shifted by 8.5 arcmin, or approximately 20 km, relative to the previous one. It is therefore located near the edge of the solar disk. Sampling times are generally 0.5, 1, and 2 s for IR, UV, and NIR channels respectively, corresponding to vertical excursions of the line of sight of 1, 2, and 4 km respectively under nominal conditions. The instrument operated from February 8 to March 26 (the martian equinox occurred on February 17). The latitude of the intersection of the Sun-spacecraft axis with the surface of Mars varied from -11 to +20, the seasonal date L(sub s) being in the range 0 - 20. All measurements were therefore made near northern spring equinox in equatorial regions. Due to an error in the pointing system, only partial results were obtained, the region below approximately equals 30 km altitude being never sounded by the UV-NIR spectrometer. On the contrary, nine complete occultations were obtained in the IR channels, whose line of sight was fortunately approximately equals 20 km below the UV-NIR axis.

Chassefiere, E.↗

On the Computation of High Order Rys Quadrature Weights and Nodes

Since its introduction in 1976, the Rys Quadrature method has proven a very attractive method for evaluating electron repulsion integrals for calculations using Gaussian type orbitals. Since then, there have been considerable refinements of the method, but at it's core, Gaussian weights and nodes are used to exactly evaluate using a numerical approach to the transform integral. One of the powers of the Rys Quadrature method is the relative ease in evaluating integrals involving functions of high angular momentum. In this work we report on the complete resolution of these numerical difficulties, and we have easily computed accurate quadrature weights and nodes up to order 101. All calculations were carried out using 128-bit precision.

Computation↗

X-Ray Diffraction on Mars: Scientific Discoveries Made by the CheMin Instrument

The Mars Science Laboratory Curiosity landed in Gale crater in August 2012 with the goal to identify and characterize habitable environments on Mars. Curiosity has been studying a series of sedimentary rocks primarily deposited in fluviolacustrine environments approximately 3.5 Ga. Minerals in the rocks and soils on Mars can help place further constraints on these ancient aqueous environments, including pH, salinity, and relative duration of liquid water. The Chemistry and Mineralogy (CheMin) X-ray diffraction and X-ray fluorescence instrument on Curiosity uses a Co X-ray source and charge-coupled device detector in transmission geometry to collect 2D Debye-Scherrer ring patterns of the less than 150 micron size fraction of drilled rock powders or scooped sediments. With an angular range of approximately 2.52deg 20 and a 20 resolution of approximately 0.3deg, mineral abundances can be quantified with a detection limit of approximately 1-2 wt. %. CheMin has returned quantitative mineral abundances from 16 mudstone, sandstone, and aeolian sand samples so far. The mineralogy of these samples is incredibly diverse, suggesting a variety of depositional and diagenetic environments and different source regions for the sediments. Results from CheMin have been essential for reconstructing the geologic history of Gale crater and addressing the question of habitability on ancient Mars.

Rampe, E. B.↗