Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Waveform Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Benchmarking Current and Emerging Approaches to Infrasound Signal Classification

Low frequency sound ≤ 20 Hz, known as infrasound, is generated by a variety of natural and anthropogenic sources. Following an event, infrasonic waves travel through a dynamic atmosphere that can change on the order of minutes. This makes infrasound event classification a difficult problem as waveforms from the same source type can look drastically different. Event classification usually requires ground truth information from seismic or other methods. This is time consuming, inefficient, and does not allow for a classification if the event locates somewhere other than a known source, the location accuracy is poor, or ground truth from seismic data is lacking. Here we compare the performance of the state of the art for infrasound event classification, support vector machine (SVM), to the performance of a convolutional neural network (CNN), a method that has been proven in tangential fields such as seismology. For a 1-class catalog consisting of only volcanic activity and earthquake events, the 4-fold average SVM classification accuracy is 75%, while it is 74% when using a CNN. Classification accuracies from the 4-class catalog consisting of the most common infrasound events detected at the global scale are 55% and 56% for the SVM and CNN architectures, respectively. These results demonstrate that using a CNN does not increase performance for infrasound event classification. This suggests that SVM should be the preferred classification method as it is a simpler and more trustworthy architecture and can be tied to the physical properties of the waveforms. The SVM and CNN algorithms described in this paper are not yet generalizable to other infrasound event catalogs. We anticipate this study to be a starting point for the development of large and comprehensive, systematically labeled, infrasound event catalogs as such catalogs will be necessary to provide an increase in the value of deep learning on event classification.

47 OTHER INSTRUMENTATION↗

The Belle II imaging Time-of-Propagation (iTOP) Detector

High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector that will take data at the SuperKEKB accelerator. With 40x the luminosity of KEKB, the detector systems must operate eciently at much higher rates than the original Belle detector. A central element of the upgrade is the barrel particle identication system. Belle II has built and installed an imaging-Time-of-Propagation (iTOP) detector. The iTOP uses quartz optics as Cerenkov radiators. The photons are transported down the quart bars via total internal reection with a spherical mirror at the forwardend to reflect photons to the backward end where they are imaged onto an array of segmented Micro-Channel Plate Photo-Multiplier Tubes. The system is readout using gigsample per second waveform sampling Application-Specific Integrated Circuits that provide precise photon timing. The combined timing and spatial distribution of the photons for each event are used to determine particle species. This paper provides an overview of the iTOP system.

Fast, James E.↗

Laser Doppler vibrometry for assessment of arteriosclerosis: A first step towards validation

It has been shown that in cardiovascular risk management, stiffness of large arteries has a very good predictive value for cardiovascular disease and mortality. This parameter can be estimated from the pulse wave velocity (PWV) measured between the common carotid artery (CCA) in the neck and femoral artery (FA) in the groin. However PWV can also be measured locally in the CCA, using non-invasive methods such as ultrasound (US) or laser Doppler vibrometry (LDV). Potential of the latter approach was already explored in previous research, and in this work a first step towards clinical validation is made. 50 hypertension II/III patients aged between 30 and 65 participate in the study. Patients were asked to remain sober for 4 hours prior to the measurements. The trajectory of the CCA in the neck was determined by a trained clinician guided by an US probe. 3 laser Doppler vibrometer (LDV) systems were aimed along the CCA. PWV was then calculated from the distance between beams and the time-shift between waveforms. Immediately after LDV measurements, PWV was measured with US. Additionally, carotid-femoral PWV was measured. As a validation, PWV results of the different techniques were compared with each other, and with medical background of the test subjects. Since data acquisition is still ongoing, data from only 20 patients will be discussed. No trends between measurement methods for PWV are apparent. However, a positive trend was detected between PWV as measured with LDV and blood pressure. More data, including additional experiments will be needed to verify this observation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of a pulsed quasi-steady MPD thruster and associated subsystems

The performance of quasi-steady magnetoplasmadynamic (MPD) thrusters at high power levels is discussed. An axisymmetric configuration is used for the MPD thruster, with various cathode and anode sizes, over a wide range of experimental conditions. Thrust is determined from impulse measurements with current waveforms, while instantaneous measurements are made for all other variables. It is demonstrated that the thrust produced has a predominately self-magnetic origin and is directly proportional to the square of the current. The complete set of impulse measurement data is presented.

Lien, H.↗

Very long baseline interferometry observations of radio emissions from geostationary satellites.

Review of the results of very long baseline interferometry (VLBI) observations of L-band emissions of the ATS-5 geostationary satellite, performed over a transcontinental baseline in 1970, as part of a more comprehensive program using radio stars as sources. Although the data were not sufficient to demonstrate fully the capability of the method for determining the orbital elements of a satellite and its inertial position, the analysis of the ATS observations show the presence of interference fringes related to the modulation waveform emitted by the satellite and to the various motions of the satellite. The measured VLBI time delays are in agreement with the geometry of the observations and with the instrumental delay, both determined independently.

Michelini, R. D.↗

An Approach to Integrated Spectrum Efficient Network Enhanced Telemetry (iSENET))

As the integrated Network Enhanced Telemetry (iNET) program moves forward in resolving systems engineering design and architecture definition, critical technology "gaps" and a migration path to realizing the integration of this technology are needed to insure a smooth transition from the current legacy point to point telemetry links to a network oriented telemetry system. Specifically, identified by the DoD aeronautical telemetry community is the need for a migration to a network solution for command, control, and transfer of test data by optimizing the physical, data link, and network layers. In this paper, we present a network-centric telemetry approach based on variants of 802.11 that leverages the open standards as well as the previous Advanced Range Telemetry (ARTM) work on the physical layer waveform. Specifically, we present a burst modem approach based on the recent AOFDM 802.11a work, a TDMA-like MAC layer approach based on 802.11e, and then add additional MAC layer features to allow for the multi-hop aeronautical environment using a variant of the current working standards of 802.11s. The combined benefits of the variants obtained from 802.11a, 802.11e, and 802.11s address the needs for both spectrum efficiency in the aeronautical environment and the iNET program.

TDMA↗

NASA Leveraging Commercial Communication Ground Stations for Small Satellites

The Space Communications and Navigation (SCaN) program at NASA has reorganized its operations portfolio into two networks: the Deep Space Network and the new Near Space Network (NSN). With this reorganization, NASA can begin transforming to 100% direct-to-Earth commercial communications services for missions in the near-Earth region. NASA’s leveraging of commercial direct-to-Earth ground stations offers several benefits for the small satellite community, including lower cost, greater coverage, and increased technology infusion. In the fall of 2020, SCaN announced their intention to rely primarily on industry-provided communications services for missions close to Earth by 2030. Commercial services are one way to infuse new technology into the ground station network without requiring an investment from NASA. Digital Video Broadcast, Satellite Second Generation (DVB-S2) is one example of a current technology. When combined with variable coding and modulation (VCM), the system automatically optimizes the data rate based on signal performance, significantly increasing total downlink data volume without an increase in the spacecraft effective isotropic radiated power (EIRP). There are several commercial service providers, including Amazon Web Service (AWS) Ground Station (AGS) and the KSATLITE ground stations that support SmallSat missions using DVB-S2 waveforms for downlinks. This paper identifies some commercial off-the-shelf (COTS) CubeSat/SmallSat DVB-S2 X-band and Ka-band radios. Overall, NASA’s increased dependence on commercial direct-to-Earth ground stations is a significant benefit for the small satellite community.

Space Communications↗

Machine Learning Techniques for Pile-Up Rejection in Cryogenic Calorimeters

CUORE Upgrade with Particle IDentification (CUPID) is a foreseen ton-scale array of Li 2 MoO 4 (LMO) cryogenic calorimeters with double readout of heat and light signals. Its scientific goal is to fully explore the inverted hierarchy of neutrino masses in the search for neutrinoless double beta decay of 100 Mo. Pile-up of standard double beta decay of the candidate isotope is a relevant background. We generate pile-up heat events via injection of Joule heater pulses with a programmable waveform generator in a small array of LMO crystals operated underground in the Laboratori Nazionali del Gran Sasso, Italy. This allows to label pile-up pulses and control both time difference and underlying amplitudes of individual heat pulses in the data. We present the performance of supervised learning classifiers on data and the attained pile-up rejection efficiency.

47 OTHER INSTRUMENTATION↗

Fast spark-detection system for GEM detectors

The sPHENIX experiment is currently under commissioning at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL). The Time Projection Chamber (TPC) serves as a tracking detector for the experiment. The sPHENIX TPC uses a stack of four Gas Electron Multipliers (GEMs) as a gain stage in a reduced ion back-flow configuration. To mitigate the damaging effects of sparks in the GEMs, an online spark monitoring system was created. Once the system detects a spark in a GEM stack, the voltages across the GEMs in that stack can be lowered to prevent further sparking without affecting the gain and efficiency of the other modules. Spark signals are coupled out of the GEM stack by a pick-off capacitor attached to the bottom of the bottom GEM. Custom PCBs convert the oscillatory spark signal into a mono-polar pulse that is then digitized. The software then saves the waveform in a server and uses experimentally derived thresholds to determine how to react. As a result, the system has so far proven to be effective at improving the stability of the TPC and preventing damaging events while collecting cosmic ray data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A machine learning framework for accurate and robust analysis of radiation detector pulses

The microscopic properties of atomic nuclei are used to study various scientific questions. They are essential for understanding the fundamental forces of nature and the chemical evolution of the universe. Detecting decay radiation from radioactive nuclei makes it possible to probe these fundamental nuclear properties. Detector waveform traces may contain additional information about the radiation. Generally, advanced signal processing techniques are needed to extract this additional information, often involving fitting the waveform with model response functions using non-linear least-squares optimization with second-order gradient methods. While this is a powerful technique, it is also computationally expensive, leading to slow processing time, which scales with the volume of data. To address this problem, we have developed a machine learning (ML) approach that infers the characteristics of traces from a model detector response function. In particular, we are interested in classifying whether a single recorded trace consists of one or two pulse constituents and estimating the pulse parameters. Furthermore, our proposed ML method can precisely extract the pulses’ parameters, such as energy and timing information, and accurately classify the pulse multiplicity of a trace. Unlike non-learning-based approaches, our ML approach uses neural networks that are significantly faster at inference, as they do not require any optimization during this stage.

Curve fitting↗

Waveform dependence on signal amplitude in the RHIC H-Jet polarimeter

A simulation of the signal waveform in the H-Jet polarimeter is discussed. The simulation includes a model of charge collection in the silicon detector and a response functions of the H-Jet front end electronics. Results of the simulation are compared with experimental data. It is shown that an analysis of the signal shape may help to suppress background in the H-Jet polarization measurements.

43 PARTICLE ACCELERATORS↗

GEOS 3 altimeter performance

GEOS 3 (Geodynamics Experimental Ocean Satellite) is the first satellite launched in the NASA Earth and Ocean Physics Applications Program and is designed to perform both geodetic and oceanographic missions. Aboard GEOS 3 is a radar altimeter for measuring the ocean surface characteristics and the spacecraft to ocean surface distance. Frequency of operation is 13.9 GHz, with two modes of operation - global or long pulse (200 nsec) mode, and intensive or short pulse (12 nsec) pulse mode. The discussion covers spacecraft and instrumentation, mission objectives, spacecraft performance, and altimeter data characteristics. Although the altimeter operation is planned only over water, the checkout of the altimeter system demonstrated that the global mode is capable of operating over land for which the terrain is not too mountainous. Sample altimeter sea surface and waveform measurements are presented.

Martin, C. F.↗

Multi-Beam Surface Lidar for Lunar and Planetary Mapping

Surface lidar techniques are now being demonstrated in low Earth orbit with a single beam of pulsed laser radiation at 1064 nm that profiles the vertical structure of Earth surface landforms along the nadir track of a spacecraft. In addition, a profiling laser altimeter, called MOLA, is operating in elliptical Martian orbit and returning surface topography data. These instruments form the basis for suggesting an improved lidar instrument that employs multiple beams for extension of sensor capabilities toward the goal of true, 3-dimensional mapping of the Moon or other similar planetary surfaces. In general the lidar waveform acquired with digitization of a laser echo can be used for laser distance measurement (i.e. range-to-the-surface) by time-of-flight measurement and for surface slope and shape measurements by examining the detailed lidar waveform. This is particularly effective when the intended target is the lunar surface or another planetary body free of any atmosphere. The width of the distorted return pulse is a first order measure of the surface incidence angle, a combination of surface slope and laser beam pointing. Assuming an independent and absolute (with respect to inertial space) measurement of laser beam pointing on the spacecraft, it is possible to derive a surface slope with-respect-to the mean planetary surface or its equipotential gravity surface. Higher-order laser pulse distortions can be interpreted in terms of the vertical relief of the surface or reflectivity variations within the area of the laser beam footprint on the surface.

Bufton, Jack L.↗

Geoscience Laser Altimeter System: Characteristics and Performance of the Altimeter Receiver

The Geoscience Laser Altimeter System (GLAS) on board ICESat spacecraft measures the surface height (altimetry) via the time of flight of its 1064 nm laser pulse. The GLAS laser transmitter produces 6 ns wide pulses with 70 mJ energy at 1064 nm at a 40 Hz rate. The altimeter receiver consists of a telescope, aft optics, a silicon avalanche photodiode, and electronic amplifiers. The transmitted and echo pulse waveforms are digitized at 1 GHz rate. The laser pulse time of flight is determined on the ground from the two digitized pulse waveforms and their positions in the full waveform record (about 5.4 ms ong) by computing the pulse centroids or by curve fitting. The GLAS receiver algorithms in on board software selects the two waveform segments containing the transmitted and the echo pulses and sends them to ground. The probability of echo pulse detection and the accuracy of time of flight measurement depend on the received signal level, the background light within the receiver field of view, the inherent detector and amplifier noise, the quantization of the digitizer, and some times by cloud obscurations. A receiver model has been developed to calculate the probability of detection and accuracy of the altimeter measurements with these noise sources. From prelaunch testing, the minimum detectable echo pulse energy for 90% detection probability was about 0.1 fj/pulse onto the detector. Such a receiver sensitivity allows GLAS to measure the surface height through clouds with optical density less than 2. The echo pulse energy required to achieve 10 cm ranging accuracy was found to be about 3 times higher than the minimum detectable signal level. The smallest single shot range measurement error, which was determined by ranging to a fixed target with strong echo pulses and no background light, was 2 to 3cm. The maximum linear response echo pulse energy was 10 fJ/pulse for the strongest echo signals, assuming a Lambertian scattering snow surface, clear sky atmosphere transmission, and no pulse width spreading due to surface slopes. Results from the initial 38 days of GLAS operation on-orbit with Laser 1, showed the echo pulse energies varied, as expected, over a wide dynamic range due to the variability of atmosphere transmission and Earth surface characteristics. The receiver was able to reliably detect the ground surface echoes and measure time of flight under such dynamic conditions, except when there were dense clouds. When over Antarctica, the echo pulse energies were several times stronger than predicted. This suggests that the 1064 nm backscattering from the snow pack and ice-sheet &ce are not completely Lambertian but is somewhat peaked at opposit.ion. With Laser 1, the peak amplitude of the echo pulses from flat ice sheets under clear sky conditions exceeded the linear response range of the receiver, causing some pulse waveform distortion due to saturation. We have characterized the effects of receiver saturation on the time of flight, pulse width, and pulse energy measurements for flat surface by testing a night spare detector in the lab with simulated echo pulses. A data processing algorithm that minimizes the errors due to saturation for these measurements are described.

Sun, Xiao-Li↗

Some Fundamental Limits on SAW RFID Tag Information Capacity and Collision Resolution

In this paper, we apply results from multi-user information theory to study the limits of information capacity and collision resolution for SAW RFID tags. In particular, we derive bounds on the achievable data rate per tag as a function of fundamental parameters such as tag time-bandwidth product, tag signal-to-noise ratio (SNR), and number of tags in the environment. We also discuss the implications of these bounds for tag waveform design and tag interrogation efficiency

Barton, Richard J.↗

Maximizing Ion Transmission in Differential Mobility Spectrometry

We provide modeling and experimental data describing the dominant ion-loss mechanisms for differential mobility spectrometry (DMS). Ion motion is considered from the inlet region of the mobility analyzer to the DMS exit, and losses resulting from diffusion to electrode surfaces, insufficient effective gap, ion fragmentation, and fringing field effects are considered for a commercial DMS system with 1-mm gap height. It is shown that losses due to diffusion and radial oscillations can be minimized with careful consideration of residence time, electrode spacing, gas flow rate, and waveform frequency. Fragmentation effects can be minimized by limitation of the separation field. When these parameters were optimized, fringing field effects at the DMS inlet contributed the most to signal reduction. We also describe a new DMS cell configuration that improves the gas dynamics at the mobility cell inlet. The new cell provides a gas jet that decreases the residence time for ions within the fringing field region, resulting in at least twofold increase in ion signal as determined by experimental data and simulations. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using a Genetic Algorithm to Model Broadband Regional Waveforms for Crustal Structure in the Western United States

In this study, we analyze regional seismograms to obtain the crustal structure in the eastern Great Basin and western Colorado plateau. Adopting a for- ward-modeling approach, we develop a genetic algorithm (GA) based parameter search technique to constrain the one-dimensional crustal structure in these regions. The data are broadband three-component seismograms recorded at the 1994-95 IRIS PASSCAL Colorado Plateau to Great Basin experiment (CPGB) stations and supplemented by data from U.S. National Seismic Network (USNSN) stations in Utah and Nevada. We use the southwestern Wyoming mine collapse event (M(sub b) = 5.2) that occurred on 3 February 1995 as the seismic source. We model the regional seismograms using a four-layer crustal model with constant layer parameters. Timing of teleseismic receiver functions at CPGB stations are added as an additional constraint in the modeling. GA allows us to efficiently search the model space. A carefully chosen fitness function and a windowing scheme are added to the algorithm to prevent search stagnation. The technique is tested with synthetic data, both with and without random Gaussian noise added to it. Several separate model searches are carried out to estimate the variability of the model parameters. The average Colorado plateau crustal structure is characterized by a 40-km-thick crust with velocity increases at depths of about 10 and 25 km and a fast lower crust while the Great Basin has approximately 35- km-thick crust and a 2.9-km-thick sedimentary layer.

Bhattacharyya, Joydeep↗

A 15GSa/s, 1.5GHz bandwidth waveform digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗