Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Aerodynamic thermal simulation system. Part 1: Radiant array (instruction manual)

An aerodynamic thermal simulation system (ATSS) is presented. The construction of the system, the maintenance, set up, and operations are reported. System description of the radiant array is given along with the array subsystems modular heating unit, adjustable stanchion frame, cooling water system, and the gaseous nitrogen cooling system. The array configuration procedure outlines the set up and the start up. Maintenance procedures involve both lamp maintenance and reflector maintenance along with weather protection. Drawing codes are included. Descriptions of the 36 zone ATSS controls are also given. Each zone is an independent closed loop temperature control circuit. Procedures are presented for starting and stopping the system. The DATA-TRAK programmer and its operation, instruction manuals for the temperature controller and the power regulator and discriptions of peripheral equipment are discussed.

Kitchar, A. F.↗

Modelica Models for Data Center Cooling Systems

This paper presents a package of Modelica models, which are dedicated to data center cooling systems and recently added to the Modelica Buildings library. To demonstrate the usage of this package, we modeled a chilled water system with an integrated wateside economizer, and an air-cooled direct expansion system with an airside economizer. These models are then applied to evaluate the control performance. After that we performed a detailed comparison in terms of system-level energy efficiency, economizing hours and supply air conditions for the two cooling systems. The advantages and disadvantages of this package are finally summarized and discussed.

Fu, Yangyang↗

Modular solar-heating system - design package

Compilation contains design, performance, and hardware specifications in sufficient detail to fabricate or procure materials and install, operate, and maintain complete modular solar heating and hot water system for single family size dwellings.

Sinton, D. S.↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Preventing leaching from lead water pipes with electrochemistry: an exploratory study

Toxic levels of lead leaching from ageing water distribution infrastructure affect over 5000 public drinking water systems in the US. Pipe replacement, the most effective solution to this problem, is prohibitively expensive. Additionally, chemical conditioning of drinking water using orthophosphates, although cost-effective, does not quickly stop lead leaching once it has started. We propose a novel approach to stop lead leaching: to rapidly form an insoluble scale within lead pipes using an external power supply. We report on the feasibility of this approach by first anodizing lead coupons and lead pipes reclaimed from a local water distribution using a phosphate electrolyte and different potentials, pH values, and phosphate concentrations. We subsequently exposed these anodized lead coupons and pipes to synthetic tap water to evaluate their lead leaching rates. We found that polarizing lead coupons in the presence of a 0.05 M phosphate solution decreased lead leaching by up to a 100-fold, relative to leaching from polished bare lead. Similarly, polarizing the reclaimed lead pipes (with a preexisting scale) decreased lead leaching from an average of 36 ppb to 7 ppb. These results were observed when applying potentials that favor Pb(IV) formation, which resulted in the buildup of PbO 2 and Pb 5 (PO 4 ) 3 OH in both lead coupons and pipes. Our findings indicate that this novel technology has the potential to rapidly decrease equilibrium lead levels in tap water below the EPA action limit of 15 ppb, and thus deserves further exploration.

54 ENVIRONMENTAL SCIENCES↗

Is there a single origin of life?

The emergence of the first life on the earth is now established as an early event, closely related to the evolving earth. Lack of knowledge of the primitive terrestrial conditions contemporary with the evolving prebolic organic chemistry limits reconstruction techniques. The primitive earth's aqueous history is essential to unraveling this problem. Based on current knowledge of other planets of the solar system, no close analog to the early earth can be expected. It is still not known if there was a second origin or if only earth has life. This may depend upon the question of the survival of information-bearing chemical systems in a dynamic or chaotic environment and the chemical protection afforded within such a system. Water is the central molecule of controversy: the blessing and the curse of the chemist. New and novel chemical mechanisms and systems abound.

Soffen, Gerald A.↗

Modeling of flow systems for implementation under KATE

The modeling of flow systems is a task currently being investigated at Kennedy Space Center in parallel with the development of the KATE artificial intelligence system used for monitoring diagnosis and control. Various aspects of the modeling issues are focussed on with particular emphasis on a water system scheduled for demonstration within the KATE environment in September of this year. LISP procedures were written to solve the continuity equations for three internal pressure nodes using Newton's method for simultaneous nonlinear equations.

Whitlow, Jonathan E.↗

STS-2 medical report

All medially related activities of the Space Transportation System 2 flight are described, ranging from preflight to postflight. Several medical problems occured during the flight. Their was marginal operation on-board potable water system caused by a malfunctioning fuel cell. Work and rest cycles by the crew were altered to maximize the scientific data acquisition. Inadequate time was allocated for food preparation and consumption. There was low water intake by the crew because of the water shortage.

Pool, S. L.↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Resilience of Interdependent Water and Power Systems: A Literature Review and Conceptual Modeling Framework

As increasing pressures of population growth and climate change arise, water and power systems (WPS) are becoming increasingly interdependent. This interdependency has resulted in an increased potential for cascading failures, whereby the service interruption of one system can propagate to interdependent ones. This paper makes four contributions. First, we present an extensive literature review in the field of integrated water and power resilience, leveraging both institutional and technical literature research landscapes. We compare various modeling approaches used to model interdependent WPS and discuss the different metrics and definitions that are typically employed to quantify and define resilience. Relevant challenges and gaps related to modeling tools and metrics are also discussed, and appropriate recommendations are made. Second, the paper presents a visualization prototype for interdependent WPS to showcase water and power system interdependencies and reveal co-managed resilience strategies that can be used to improve resilience under different types of common threats. Third, we provide a conceptual decision support framework that simultaneously optimizes a portfolio of co-managed resilience strategies in the face of multiple, uncertain threats and addresses WPS interdependencies. Finally, we present future trends regarding digitalization, integrated planning, collaborative governance, and equity needs for building more resilient WPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Best Practices Case Study: CDC Realty, Inc. - Centennial Terrace, Tucson, AZ

Case study on CDC Realty who achieved HERS 70 by putting ducts in a conditioned attic insulated along the roofline with netted cellulose, R-5 rigid insulated sheathing over R-19 wall cavity insulation, and deep overhangs and low-e windows to minimize solar heat gain. The 17 homes are solar-ready for solar water heating and five have integral collector storage hot water systems on the roof.

Building America↗

Human virus and microbial indicator occurrence in public-supply groundwater systems: meta-analysis of 12 international studies

Groundwater quality is often evaluated using microbial indicators. This study examines data from 12 international groundwater studies (conducted 1992–2013) of 718 public drinking-water systems located in a range of hydrogeological settings. Focus was on testing the value of indicator organisms for identifying virus-contaminated wells. One or more indicators and viruses were present in 37 and 15% of 2,273 samples and 44 and 27% of 746 wells, respectively. Escherichia coli ( E. coli ) and somatic coliphage are 7– 9 times more likely to be associated with culturable viruspositive samples when the indicator is present versus when it is absent, while F-specific and somatic coliphages are 8–9 times more likely to be associated with culturable viruspositive wells. However, single indicators are only marginally associated with viruses detected by molecular methods, and all microbial indicators have low sensitivity and positive predictive values for virus occurrence, whether by culturable or molecular assays, i.e., indicators are often absent when viruses are present and the indicators have a high false-positive rate. Wells were divided into three susceptibility subsets based on presence of (1) total coliform bacteria or (2) multiple indicators, or (3) location of wells in karst, fractured bedrock, or gravel/cobble settings. Better associations of some indicators with viruses were observed for (1) and (3). Findings indicate the best indicators are E. coli or somatic coliphage, although both indicators may underestimate virus occurrence. Repeat sampling for indicators improves evaluation of the potential for viral contamination in a well.

58 GEOSCIENCES↗

The Use of Flow-Injection Analysis with Chemiluminescence Detection of Aqueous Ferrous Iron in Waters Containing High Concentrations of Organic Compounds

An evaluation of flow-injection analysis with chemiluminescence detection (FIA-CL) to quantify Fe2+ (aq) in freshwaters was performed. Iron-coordinating and/or ironreducing compounds, dissolved organic matter (DOM), and samples from two natural water systems were used to amend standard solutions of Fe2+ (aq). Slopes of the response curves from ferrous iron standards (1 – 100 nM) were compared to the response curves of iron standards containing the amendments. Results suggest that FIA-CL is not suitable for systems containing ascorbate, hydroxylamine, cysteine or DOM. Little or no change in sensitivity occurred in solutions of oxalate and glycine or in natural waters with little organic matter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thyroid Function Changes Related to Use of Iodinated Water in United States Space Program

The National Aeronautics and Space Administration (NASA) has used iodination as a method of microbial disinfection of potable water systems in United States spacecraft and long-duration habitability modules. A review of the effects on the thyroid following consumption o iodinated water by NASA astronauts was conducted. Pharmacological doses of iodine consumed by astronauts transiently decreased thyroid function, as reflected in serum TSH values. Although the adverse effects of excess iodine consumption in susceptible individuals are well documented, exposure to high doses of iodine during space flight did not result in a statistically significant increase in long-term thyroid disease in the astronaut population.

McMonigal, Kathleen A.↗

Zero-power wireless system for crop water content monitoring

Zero power wireless sensors, devices, and systems are used for crop water content monitoring. The sensors consume no power while monitoring for the presence of dry crop conditions. Infrared reflectance from plants is measured and when selected spectral conditions are met, a circuit is closed, activating an alarm, an RFID tag, or a radio transmitter. The deployed sensors consume no power while monitoring, reducing or eliminating the need to change batteries.

Rinaldi, Matteo↗

Photocatalytic degradation of organic pollutants coupled with simultaneous photocatalytic H 2 evolution over graphene quantum dots/Mn-N-TiO 2 /g-C 3 N 4 composite catalysts: Performance and mechanism

Graphene quantum dots/Mn-N-TiO 2 /g-C 3 N 4 (GQDs/TCN) composite photocatalysts have been designed, synthesized and characterized by XRD, SEM, TEM, Raman, BET, and XPS. The photodegradation of organic pollutants (p-nitrophenol, diethyl phthalate and ciprofloxacin, called as 4-NP, CIP and DEP, respectively) coupled with simultaneous photocatalytic production of hydrogen was successfully achieved using the GQDs/TCN catalysts. The 5%GQDs/TCN-0.4 sample shows the best photocatalytic hydrogen production and organic pollutant degradation rate under simulated solar irradiation in the simultaneous photocatalytic oxidation and reduction system. Furthermore, the photocatalytic H 2 evolution rates in the solution of 4-NP, CIP and DEP are all larger than that in pure water system over the 5%GQDs/TCN-0.4 catalyst. And the H 2 evolution rate in the solution of 4-NP is smaller than that in the solutions of CIP and DEP. Accordingly, the photodegradation rate of 4-NP is larger than that of CIP and DEP. The analyses of density functional theory and liquid chromatography mass spectrometry indicate that some photogenerated electrons were used in the photodegradation process of 4-NP but not in that of CIP and DEP. And it leads to the photocatalytic rate of H 2 evolution in the 4-NP solution smaller than that in the solution of CIP and DEP. For the first time, the present work illuminates the photocatalytic enhancement of the GQDs/TCN-0.4 catalyst and the mechanism of the effect of different organic pollutants on photocatalytic H 2 evolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Factors controlling the oxygen isotopic composition of lacustrine authigenic carbonates in Western China: implications for paleoclimate reconstructions

Abstract In the carbonate-water system, at equilibrium, the oxygen isotopic composition of carbonate is dependent not only on the temperature but also on the isotopic composition of host water in which the carbonate is formed. In this study, lake surface sediment and water samples were collected from 33 terminal lakes in Western China to evaluate controls on the oxygen isotopic composition of lacustrine authigenic carbonates (δ 18 O carb ) and its spatial distribution. Our results show that water oxygen isotopic composition (δ 18 O water ) rather than lake summer water temperature (T water ), is the main determinant of δ 18 O carb , irrespective of whether oxygen isotope equilibrium is achieved. There are significant linear correlations between δ 18 O carb and elevation, as well as that between δ 18 O carb and latitude for lakes located on the Tibetan Plateau. In Western China, the spatial distribution of δ 18 O carb is consistent with that of δ 18 O water , and is ultimately controlled by the isotopic composition of local precipitation (δ 18 O precipitation ) that depends on the source of water vapor. Therefore, changes in δ 18 O carb can be predominantly interpreted as variations of δ 18 O water , which in turn represent changes in δ 18 O precipitation for paleoclimate reconstructions in this region, and may be relevant to studies of other areas.

59 BASIC BIOLOGICAL SCIENCES↗