Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Geothermal play fairway analysis, part 1: Example from the Snake River Plain, Idaho

The Snake River Plain (SRP) volcanic province overlies the track of the Yellowstone hotspot, a thermal anomaly that extends deep into the mantle. Most of the area is underlain by a basaltic volcanic province that overlies a mid-crustal intrusive complex, which in turn provides the long-term heat flux needed to sustain geothermal systems. Previous studies have identified several known geothermal resource areas within the SRP. For the geothermal study presented herein, our goals were to: (1) adapt the methodology of Play Fairway Analysis (PFA) for geothermal exploration to create a formal basis for its application to geothermal systems, (2) assemble relevant data for the SRP from publicly available and private sources, and (3) build a geothermal PFA model for the SRP and identify the most promising plays, using GIS-based software tools that are standard in the petroleum industry. The study focused on identifying three critical resource parameters for exploitable hydrothermal systems in the SRP: heat source, reservoir and recharge permeability, and cap or seal. Data included in the compilation for heat source were heat flow, distribution and ages of volcanic vents, groundwater temperatures, thermal springs and wells, helium isotope anomalies, and reservoir temperatures estimated using geothermometry. Reservoir and recharge permeability was inferred from the analysis of stress orientations and magnitudes, post-Miocene faults, and subsurface structural lineaments based on magnetics and gravity data. Data for cap or seal included the distribution of impermeable lake sediments and clay-seal associated with hydrothermal alteration below the regional aquifer. These data were used to compile Common Risk Segment maps for heat, permeability, and seal, which were combined to create a Composite Common Risk Segment map for all southern Idaho that reflects the risk associated with geothermal resource exploration and identifies favorable resource tracks. Our regional assessment indicated that undiscovered geothermal resources may be located in several areas of the SRP. Two of these areas, the western SRP and Camas Prairie, were selected for more detailed assessment, during which heat, permeability, and seal were evaluated using newly collected field data and smaller grid parameters to refine the location of potential resources. These higher resolution assessments illustrate the flexibility of our approach over a range of scales.

54 ENVIRONMENTAL SCIENCES↗

Geothermal Play Fairway Analysis, Part 2: GIS methodology

Play Fairway Analysis (PFA) in geothermal exploration originates from a systematic methodology developed within the petroleum industry and is based on a geologic, geophysical, and hydrologic framework of identified geothermal systems. We tailored this methodology to study the geothermal resource potential of the Snake River Plain and surrounding region, but it can be adapted to other geothermal resource settings. We adapted the PFA approach to geothermal resource exploration by cataloging the critical elements controlling exploitable hydrothermal systems, establishing risk matrices that evaluate these elements in terms of both probability of success and level of knowledge, and building a code-based ‘processing model’ to process results. A geographic information system was used to compile a range of different data types, which we refer to as elements (e.g., faults, vents, heat flow, etc.), with distinct characteristics and measures of confidence. Discontinuous discrete data (points, lines, or polygons) for each element were transformed into continuous interpretive 2D grid surfaces called evidence layers. Because different data types have varying uncertainties, most evidence layers have an accompanying confidence layer which reflects spatial variations in these uncertainties. Risk layers, as defined here, are the product of evidence and confidence layers, and are the building blocks used to construct Common Risk Segment (CRS) maps for heat, permeability, and seal, using a weighted sum for permeability and heat, but a different approach with seal. CRS maps quantify the variable risk associated with each of these critical components. In a final step, the three CRS maps were combined into a Composite Common Risk Segment (CCRS) map, using a modified weighted sum, for results that reveal favorable areas for geothermal exploration. Additional maps are also presented that do not mix contributions from evidence and confidence (to allow an isolated view of evidence and confidence), as well as maps that calculate favorability using the product of components instead of a weighted sum (to highlight where all components are present). Our approach helped to identify areas of high geothermal favorability in the western and central Snake River Plain during the first phase of study and helped identify more precise local drilling targets during the second phase of work. By identifying favorable areas, this methodology can help to reduce uncertainty in geothermal energy exploration and development.

15 GEOTHERMAL ENERGY↗

Large-Scale Utilization of Biomass Energy and Carbon Dioxide Capture and Storage in the Transport and Electricity Sectors under Stringent CO2 Concentration Limit Scenarios

This paper examines the potential role of large scale, dedicated commercial biomass energy systems under global climate policies designed to meet atmospheric concentrations of CO2 at 400ppm and 450ppm by the end of the century. We use an integrated assessment model of energy and agriculture systems to show that, given a climate policy in which terrestrial carbon is appropriately valued equally with carbon emitted from the energy system, biomass energy has the potential to be a major component of achieving these low concentration targets. A key aspect of the research presented here is that the costs of processing and transporting biomass energy at much larger scales than current experience are explicitly incorporated into the modeling. From the scenario results, 120-160 EJ/year of biomass energy is produced globally by midcentury and 200-250 EJ/year by the end of this century. In the first half of the century, much of this biomass is from agricultural and forest residues, but after 2050 dedicated cellulosic biomass crops become the majority source, along with growing utilization of waste-to-energy. The ability to draw on a diverse set of biomass based feedstocks helps to reduce the pressure for drastic large-scale changes in land use and the attendant environmental, ecological, and economic consequences those changes would unleash. In terms of the conversion of bioenergy feedstocks into value added energy, this paper demonstrates that biomass is and will continue to be used to generate electricity as well as liquid transportation fuels. A particular focus of this paper is to show how climate policies and technology assumptions - especially the availability of carbon dioxide capture and storage (CCS) technologies - affect the decisions made about where the biomass is used in the energy system. The potential for net-negative electric sector emissions through the use of CCS with biomass feedstocks provides an attractive part of the solution for meeting stringent emissions constraints; we find that at carbon prices above 150$/tCO2, over 90% of biomass in the energy system is used in combination with CCS. Despite the higher technology costs of CCS, it is a very important tool in controlling the cost of meeting a target, offsetting the venting of CO2 from sectors of the energy system that may be more expensive to mitigate, such as oil use in transportation. CCS is also used heavily with other fuels such as coal and natural gas, and by 2095 a total of 1530 GtCO2 has been stored in deep geologic reservoirs. The paper also discusses the role of cellulosic ethanol and Fischer-Tropsch biomass derived transportation fuels as two representative conversion processes and shows that both technologies may be important contributors to liquid fuels production, with unique costs and emissions characteristics.

01 COAL, LIGNITE, AND PEAT↗

A screening-level life cycle greenhouse gas analysis of CO 2 enhanced oil recovery with CO 2 sourced from the Shute Creek natural gas-processing facility

This life cycle analysis (LCA) evaluates life cycle greenhouse gas (GHG) emissions associated with a system that produces both natural gas and crude oil. Two systems are defined: System 1, which independently produces natural gas and oil, and System 2, which captures carbon dioxide (CO 2 ) from the natural gas-processing plant and utilizes this captured CO 2 for enhanced oil recovery (EOR). The LCA uses customized spreadsheet models with emission factors from peer-reviewed literature and publications of the National Energy Technology Laboratory of the U.S. Department of Energy. The modeling results show that the CO 2 EOR scenario using captured CO 2 produces both natural gas and oil with lower life cycle GHG emissions than alternative systems producing natural gas and oil independently. Sensitivity analyses show that the model results are most sensitive to the fraction of CO 2 captured (or equivalently, the fraction of CO 2 vented) at the natural gas-processing facility and the incremental oil recovery factor and net CO 2 utilization factor of the EOR operations. The input variable driving the relative difference in life cycle GHG emissions between these two systems is the fraction of CO 2 captured at the natural gas-processing facility (i.e., the capture rate). Here, the results of this study highlight the necessity of linking processes in the life cycle modeling, as a change to one process can affect other processes within the coupled energy system comprised of natural gas and oil. In addition, this analysis shows, as prior work has also suggested, that CO 2 EOR using captured anthropogenic CO 2 provides a viable means for offsetting carbon emissions from oil production and combustion via the associated storage of CO 2 that occurs incidentally during this tertiary method of oil recovery.

02 PETROLEUM↗

Numerical simulation of compressible fluid-dynamics in the chamber of inertial fusion energy systems

Here, this paper aims to establish new and innovative modeling capabilities for analyzing chambers in Inertial Fusion Energy (IFE) systems. IFE is emerging as a promising method to achieve fusion power production, but several challenges must be overcome to develop an IFE pilot plant or deploy commercial IFE systems. These challenges are both theoretical and technical, encompassing a deeper understanding of the underlying physical phenomena and the development of new technologies and materials. One of the needs is to develop mathematical models to describe IFE systems and numerical tools to simulate them. This paper contributes to this endeavor by presenting a new OpenFOAM solver for IFE systems, focusing on gas dynamics in their chambers. The analysis and development of chamber designs will play a significant role in the transition from single-shot experiments to high-repetition rates, as there is a need to protect the chamber walls from the intense radiation fields produced by fusion reactions. A promising design option, normally referred to as thick wall chamber design, consists in using lithium or molten salt jet arrays within the chamber. A critical phenomenon is the venting of high-pressure gases from the center to the external part of the chamber, passing through the blanket array. This process involves the propagation and attenuation of strong pressure waves, requiring suitable modeling approaches for compressible fluid-dynamics. The solver proposed in this work implements a multi-material hydrodynamics model tailored to accurately describe the non-linear propagation of pressure waves while avoiding numerical oscillation issues typical of high-velocity compressible simulation. This solver is verified against numerical test cases, validated against experimental data, and applied to the analysis of the High-Yield Lithium-Injection Fusion-Energy (HYLIFE-I) concept. The relevance of this paper is threefold. Firstly, it contributes to developing and testing modeling approaches for compressible fluid-dynamics phenomena, with specific focus on the new and unexplored topic of IFE thick-liquid-wall blanket modeling. Secondly, it marks one of the first applications of the OpenFOAM library in the research field of IFE systems. Finally, the investigated problem is of practical interest for IFE developers, as it provides useful indications about relevant phenomena in pressure wave propagation in the chamber of these systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The potential for avoiding hydrogen release from cryogenic pressure vessels after vacuum insulation failure

This paper presents an analysis of vacuum insulation failure in an automotive cryogenic pressure vessel (also known as cryo-compressed vessel) storing hydrogen. Vacuum insulation failure increases heat transfer into cryogenic vessels by about a factor of 100, potentially leading to rapid pressurization and venting of the cryogen to avoid exceeding maximum allowable working pressure (MAWP). Hydrogen release to the environment may be dangerous, especially if the vehicle is located in a closed space (e.g. a garage or tunnel) at the moment of insulation failure. We therefore consider utilization of the hydrogen in the vehicle fuel cell and dissipation of the electricity by operating vehicle accessories or electric resistances as an alternative to releasing hydrogen to the environment. We consider two strategies: initiating hydrogen extraction immediately after vacuum insulation failure or waiting until maximum operating pressure is reached before extraction. The results indicate that cryogenic pressure vessels have thermodynamic advantages that enable slowing down hydrogen release to moderate levels that can be consumed in the fuel cell and dissipated in vehicle accessories supplemented by electric resistances, even in the worst case when the insulation fails at the moment when the vessel stores hydrogen near its maximum density (70 g/L at 300 bar). As a result, the two proposed strategies are therefore feasible, and the best alternative can be chosen based on economic and/or implementation constraints.

08 HYDROGEN↗

Hydrogen losses in fueling station operation

This paper describes an engineering approach for hydrogen accounting from production to dispensing at Cal State Los Angeles Hydrogen Research and Fueling Facility, equipped with an electrolyzer for on-site production. Particularly, the accounting process has been carried out by taking an in-depth look at current practices and databases, and its analysis has been based on data from quarterly reports of hydrogen production and dispensing related parameters and from its data acquisition system. It is described how the station addressed this analysis investigating several station areas. Following there is an assessment of the possible critical points, flanked by considerations, calculations, mathematical modeling and analysis of the database. The analysis led to a marked improvement on the station operation know-how. For most of the analyzed months the current average percentage of losses was found to be between 2 and 10%, whereas before it was between 30 and 35%. This current range of percentage (2–10)% includes all experiments done, defueling the buffer tanks, rebooting the dispenser, venting the lines, the uncertainty of the mass flow meter inside the dispenser (±5%) and the inherent uncertainty of Faraday’s law for hydrogen production estimate. Among all areas analyzed, maintenance activities revealed themselves as the most critical ones, leading to data mismatching in hydrogen accounting. The paper aims also to provide a guideline with recommended practices based on our experience, deduced for station operators and builders, including several steps for leakage monitoring, prevention, and troubleshooting.

08 HYDROGEN↗

Computation of probabilistic hazard maps and source parameter estimation for volcanic ash transport and dispersion

Volcanic ash advisory centers are charged with forecasting the movement of volcanic ash plumes, for aviation, health and safety preparation. Deterministic mathematical equations model the advection and dispersion of these plumes. However initial plume conditions – height, profile of particle location, volcanic vent parameters – are known only approximately at best, and other features of the governing system such as the windfield are stochastic. These uncertainties make forecasting plume motion difficult. As a result of these uncertainties, ash advisories based on a deterministic approach tend to be conservative, and many times over/under estimate the extent of a plume. This paper presents an end-to-end framework for generating a probabilistic approach to ash plume forecasting. This framework uses an ensemble of solutions, guided by Conjugate Unscented Transform (CUT) method for evaluating expectation integrals. This ensemble is used to construct a polynomial chaos expansion that can be sampled cheaply, to provide a probabilistic model forecast. The CUT method is then combined with a minimum variance condition, to provide a full posterior pdf of the uncertain source parameters, based on observed satellite imagery. The April 2010 eruption of the Eyjafjallajökull volcano in Iceland is employed as a test example. The puff advection/dispersion model is used to hindcast the motion of the ash plume through time, concentrating on the period 14–16 April 2010. Variability in the height and particle loading of that eruption is introduced through a volcano column model called bent. Output uncertainty due to the assumed uncertain input parameter probability distributions, and a probabilistic spatial-temporal estimate of ash presence are computed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of CAP88 PC to infer differences in the chemical form of I-129 emitted from a fuel reprocessing facility

Emissions of 129I from nuclear fuel separations conducted at the Hanford Site in Washington State have been occurring since the 1940’s. Fuel separation on the Hanford Site stopped in 1988, but emissions of 129I have continued as venting of the building occurred. In this study, atmospheric measurements of 129I concentrations were coupled with an EPA approved plume dispersion model (CAP-88PC) to evaluate the effectiveness of the dispersion model for estimating ambient concentrations at the Hanford Site. This evaluation led to the hypothesis of different chemical forms of iodine being emitted over the years; this hypothesis was developed as an explanation for the model agreeing with measurements over some time periods, but not over all time periods. The model was then run with modified emissions to simulate the short atmospheric half-life of the suspected reactive chemical form of iodine being emitted. This modification resulted in good agreement between the modeled and measured concentrations over the entire 20 year study period, and provided evidence that the hypothesis of a reactive form of iodine being emitted was correct.

Fritz, Brad G.↗

Radiocesium ( 137 Cs) concentrations in the two-toed amphiuma (Amphiuma means) and the lesser siren (Siren intermedia)

This study sought to determine radiocesium ( 137 Cs) concentrations in two species of aquatic salamanders – the two-toed amphiuma (Amphiuma means) and the lesser siren (Siren intermedia) on the Savannah River Site. Concentrations ( 137 Cs Bq/g, dry wt) of the two species were similar at both 137 Cs-contaminated (A. means = 0.733 ± 0.242, n = 5; S. intermedia = 0.839 ± 0.722, n = 5) and reference sites (A. means = 0.028 ± 0.020, n = 5; S. intermedia = 0.042 ± 0.027, n = 11). Salamanders captured in areas impacted by 137 Cs contamination exhibited significantly higher 137 Cs concentrations than individuals captured at reference sites (U = 146, p < 0.001). Salamander size (snout-vent length) was not correlated with whole-body 137 Cs. An analysis of our data using the ERICA tool suggests that negative impacts due to 137 Cs exposure are unlikely in these species. Overall, these data indicate that A. means and S. intermedia inhabiting contaminated sites bioaccumulate but do not biomagnify 137 Cs.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Effect of overcharge on Li(Ni 0.5 Mn 0.3 Co 0.2 )O 2 /graphite lithium ion cells with poly(vinylidene fluoride) binder. III — Chemical changes in the cathode

Here, 1.5 Ah pouch cells based on Li(Ni 0.5 Mn 0.3 Co 0.2 )O 2 cathodes and graphite anodes, both containing poly (vinylidene fluoride) (PVDF) binders, were systematically overcharged to 100, 120, 140, 160, 180, and 250% state of charge (SOC), at which point they vented. The cells were subsequently discharged to 0% SOC and disassembled under an inert atmosphere for characterization. A combination of X-ray photoelectron spectroscopy (XPS), scanning-electron microscopy (SEM), energy-dispersive spectroscopy (EDS), 6 Li SSNMR, and X-ray diffraction (XRD) analysis of the NMC532 cathodes indicates the formation of a thin C- and O-rich cathode electrolyte interphase layer, progressive Li loss above 140% SOC, and retention of the bulk crystal structure at all states of charge.

25 ENERGY STORAGE↗

Effect of overcharge on Li(Ni 0.5 Mn 0.3 Co 0.2 )O 2 /Graphite lithium ion cells with poly(vinylidene fluoride) binder. I - Microstructural changes in the anode

Cells based on NMC/graphite, containing poly(vinylidene difluoride) (PVDF) binders in the positive and negative electrodes, were systematically overcharged to 100, 120, 140, 160, 180, and 250% state-of-charge (SOC). At 250% SOC the cell vented. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) of the anodes showed several state-of-overcharge-dependent trends. Starting at 120% SOC, dendrites appeared and increased in concentration as the SOC increased. Dendrite morphology appeared to be dependent on whether the active material was on the “dull” or “shiny” side of the copper collector. Significantly more delamination of the active material from the collector was seen on the “shiny” side of the collector particularly at 180 and 250% SOC. Transition metals were detected at 120% SOC and increased in concentration as the SOC increased. Finally, there was considerable spatial heterogeneity in the microstructures across each laminate with several regions displaying complex layered structures.

25 ENERGY STORAGE↗

Decoupling of heat generated from ejected and non-ejected contents of 18650-format lithium-ion cells using statistical methods

Effective thermal management systems, designed to handle the impacts of thermal runaway (TR) and to prevent cell-to-cell propagation, are key to safe operation of lithium-ion (Li-ion) battery assemblies. Critical factors for optimizing these systems include the total energy released during a single cell TR event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A unique fractional thermal runaway calorimeter (FTRC), designed to characterize said critical factors, was utilized to examine the TR behavior of 18650-format Li-ion cells representing a variety of manufacturers, chemistries, capacities, and safety features. Primarily, the impacts of bottom vent (BV) safety features, varied cell casing thickness, and Dreamweaver cellulose based separators were assessed for select cell types. A subset of cells also had an imbedded internal short circuiting (ISC) device to allow examination of TR behavior initiated at lower temperatures (i.e. closer to field failure conditions). The impact of bottom rupture on TR behavior was also examined for experiments that resulted in this non-standard failure mechanism. Statistical analysis of the results for each cell configuration reveals that a lognormal distribution effectively characterizes the variation of total TR energy release. Typically 20%-30% of the total energy yield is released through the cell casing with the remainder through the ejecta material. Higher energy cells tend to exhibit more violent ejections and less predictable TR events. Inclusion of a BV feature reduces the overall severity of the TR event and can increase the predictability. Results also suggest that the magnitude of the TR event may not be directly proportional to the stored electrical energy, but rather has additional dependence on other design and failure mode factors.

25 ENERGY STORAGE↗

Modelling and experiments to identify high-risk failure scenarios for testing the safety of lithium-ion cells

Intentionally inducing worst-case thermal runaway scenarios in Li-ion cells on-demand is a definitive way to test the efficacy of battery systems in safely mitigating the consequences of catastrophic failure. An internal short-circuiting (ISC) device is implanted into three 18650 cell designs: one standard, one with a bottom vent, and one with a thicker casing. Through an extensive study of 228 cells, the position at which thermal runaway initiates is shown to greatly affect the tendency of cells to rupture and incur side-wall breaches at specific locations. The risks associated with each failure mechanism and position of the ISC device are quantified using a custom calorimeter that can decouple the heat from ejected and non-ejected contents. Furthermore the causes of high-risk failure mechanisms, such as bursting and side-wall breaches, are elucidated using high-speed synchrotron X-ray imaging at 2000 frames per second and image-based 3D thermal runaway computational models, which together are used to construct a comprehensive description of external risks based on internal structural and thermal phenomena.

25 ENERGY STORAGE↗

The battery failure databank: Insights from an open-access database of thermal runaway behaviors of Li-ion cells and a resource for benchmarking risks

The thermal response of Li-ion cells can greatly vary for identical cell designs tested under identical conditions, the distribution of which is costly to fully characterize experimentally. The open-source Battery Failure Databank presented here contains robust, high-quality data from hundreds of abuse tests spanning numerous commercial cell designs and testing conditions. Data was gathered using a fractional thermal runaway calorimeter and contains the fractional breakdown of heat and mass that was ejected, as well as high-speed synchrotron radiography of the internal dynamic response of cells during thermal runaway. The distribution of thermal output, mass ejection, and internal response of commercial cells are compared for different abuse-test conditions, which when normalized on a per amp-hour basis show a strong positive correlation between heat output from cells, the fraction of mass ejected from the cells, their energy- and power-density. Ejected mass was shown to contain 10x more heat per gram than non-ejected mass. The causes of 'outlier' thermal and ejection responses i.e., extreme cases, are elucidated by high-speed radiography which showed how occurrences such as vent clogging can create more hazardous conditions. High-speed radiography also demonstrated how the time-resolved interplay of thermal runaway propagation and mass ejection influences the total heat generated.

25 ENERGY STORAGE↗

Gas-driven short disconnection mitigates thermal runaway in Li-ion batteries under mechanical abuse

Mechanical abuse poses a critical safety risk to Li-ion batteries by inducing internal short circuits that initiate thermal runaway. Remarkably, voltage recovery frequently emerges during thermal runaway initiation, a phenomenon that conventional theories fail to explain. Here, our study develops a new multiphysics mechanism to explain voltage recovery, termed gas-driven short disconnection, whereby internal gas pressure mechanically disengages short-circuit contacts and causes the cell voltage to rebound. This mechanism incorporates gas generation and its structural impact on the short circuit. Real-time optical and thermal imaging and X-ray computed tomography reveal fluid-structure interaction between internal gas flow and adjacent shorting contacts. We establish a mechanistic framework linking gas-driven short disconnection to cell-level voltage and temperature responses, elucidating the extension–truncation pattern of voltage recovery. Furthermore, thermal regime maps show that a voltage recovery duration exceeding 5 s correlates with limited temperature rise below 150 °C, indicating that sustained short-circuit disconnection suppresses Joule heating. Additionally, a dimensionless criterion is deduced from scaling analysis for physical plausibility of gas-driven short disconnection in mechanically abused cells. This finding inspires smart venting control, which regulates gas release to maintain the internal pressure while dissipating gas enthalpy, thereby providing a device-level strategy for thermal runaway mitigation.

Gas-driven short disconnection↗

A pseudo-kinetic model to simulate phase changes in gas hydrate bearing sediments

Herein, modeling of the phase transitions anticipated in gas hydrate bearing sediments (GHBS) is critical for a proper understanding of time-dependent changes in states and volumes (e.g. the production of methane from this type of soils). We propose a new pseudo-kinetic approach to simulate the typical phase changes anticipated in GHBS, using published experimental results involving gas hydrate dissociation that are the basis of a widely used kinetic model. The proposed pseudo-kinetic model is formulated in the pressure-temperature (P-T) plane and assumes a rate of gas hydrate dissociation (or formation) proportional to the distance between the current state and the phase boundary. The model consists of only one parameter and is simple to implement in numerical simulators. A similar concept is used to model ice formation/thawing phenomena, but based on the ice/liquid-water phase boundary. We implemented the pseudo-kinetic model in a fully coupled thermo-hydro-chemo-mechanical (THCM) finite element code and validated it against experimental results performed on the dissociation of synthetic gas hydrate. We also evaluated the pseudo-kinetic model using synthetic cases covering several scenarios associated with gas hydrate formation/dissociation and ice formation/thawing. The model successfully reproduced the gas production test from a natural GHBS core from Korea (scaled gas venting experiment over 14 h), and also the formation of gas hydrate and ice in permafrost in Alaska (over 2 × 10 6 years). -The analyses show the versatility of the proposed pseudo-kinetic approach by applying it to model the different types of phase transitions typically encounter in GHBS. The simple formulation, easy implementation in numerical simulator, and reduced number of parameters (only one per phase change) make this model an attractive option for simulating phase transformations in problems involving GHBS.

58 GEOSCIENCES↗