Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

The Observed Variance Between Predicted and Measured Radiation Dose in Breast and Prostate Patients Utilizing an In Vivo Dosimeter

Purpose: Report the results of using a permanently implantable dosimeter in radiation therapy: determine specific adverse events, degree of migration, and acquire dose measurements during treatment to determine difference between expected and measured dose. Methods and Materials: The Dose Verification System is a wireless, permanently implantable metal-oxide semiconductor field-effect transistor dosimeter using a bidirectional antenna for power and data transfer. The study cohort includes 36 breast (33 patients received two devices) and 29 prostate (21 patients received two devices) cancer patients. A total of 1,783 and 1,749 daily dose measurements were obtained on breast and prostate patients, respectively. The measurements were compared with the planned expected dose. Biweekly computed tomography scans were obtained to evaluate migration and the National Cancer Institute's Common Toxicity Criteria, version 3, was used to evaluate adverse events. Results: Only Grade I/II adverse events of pain and bleeding were noted. There were only four instances of dosimeter migration of >5 mm from known factors. A deviation of {>=}7% in cumulative dose was noted in 7 of 36 (19%) for breast cancer patients. In prostate cancer patients, a {>=}7% deviation was noted in 6 of 29 (21%) and 8 of 19 (42%) during initial and boost irradiation, respectively. The two patterns of dose deviation were random and systematic. Some causes for these differences could involve organ movement, patient movement, or treatment plan considerations. Conclusions: The Dose Verification System was not associated with significant adverse events or migration. The dosimeter can measure dose in situ on a daily basis. The accuracy and utility of the dose verification system complements current image-guided radiation therapy and intensity-modulated radiation therapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Utility of the Modified Segmental Boost Technique for Treatment of the Pelvis and Inguinal Nodes

Purpose: Low-lying pelvic malignancies often require simultaneous radiation to pelvis and inguinal nodes. We previously reported improved homogeneity with the modified segmental boost technique (MSBT) compared to that with traditional methods, using phantom models. Here we report our institutional clinical experience with MSBT. Methods and Materials: MSBT patients from May 2001 to March 2007 were evaluated. Parameters analyzed included isocenter/multileaf collimation shifts, time per fraction (four fields), monitor units (MU)/fraction, femoral doses, maximal dose relative to body mass index, and inguinal node depth. In addition, a dosimetric comparison of the MSBT versus intensity modulated radiation therapy (IMRT) was conducted. Results: Of the 37 MSBT patients identified, 32 were evaluable. Port film adjustments were required in 6% of films. Median values for each analyzed parameter were as follows: MU/fraction, 298 (range, 226-348); delivery time, 4 minutes; inguinal depth, 4.5 cm; volume receiving 45 Gy (V45), 7%; V27.5, 87%; body mass index, 25 (range, 16.0-33.8). Inguinal dose was 100% in all cases; in-field inhomogeneity ranged from 111% to 118%. IMRT resulted in significantly decreased dose to normal tissue but required more time for treatment planning and a higher number of MUs (1,184 vs. 313 MU). Conclusions: In our clinical experience, the mono-isocentric MSBT provides a high degree of accuracy, improved homogeneity compared with traditional techniques, ease of simulation, treatment planning, treatment delivery, and acceptable femoral doses for pelvic/inguinal radiation fields requiring 45 to 50.4 Gy. In addition, the MSBT delivers a relatively uniform dose distribution throughout the treatment volume, despite varying body habitus. Clinical scenarios for the use of MSBT vs. intensity-modulated radiation therapy are discussed. To our knowledge, this is the first study reporting the utility of MSBT in the clinical setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Utilization of Adjuvant Radiotherapy and Outcomes in Black Women After Breast Conservation at a Large Multidisciplinary Cancer Center;Black women; Breast cancer; Radiotherapy; RT; Breast conservation

Purpose: Population-based studies have reported that as many of 35% of black women do not undergo radiotherapy (RT) after breast conservation surgery (BCS). The objective of the present study was to determine whether this trend persisted at a large multidisciplinary cancer center, and to identify the factors that predict for noncompliance with RT and determine the outcomes for this subset of patients. Methods and Materials: Between January 2002 and December 2007, 83 black women underwent BCS at Memorial Sloan-Kettering Cancer Center and were therefore eligible for the present study. Of the 83 women, 38 (46%) had Stage I, 38 (46%) Stage II, and 7 (8%) Stage III disease. Of the study cohort, 31 (37%) had triple hormone receptor-negative tumors. RT was recommended for 81 (98%) of the 83 patients (median dose, 60 Gy). Results: Of the 81 women, 12 (15%) did not receive the recommended adjuvant breast RT. Nonreceipt of chemotherapy (p = .003) and older age (p = .009) were associated with nonreceipt of RT. With a median follow-up of 70 months, the 3-year local control, locoregional control, recurrence-free survival, disease-free survival, and overall survival rate was 99% (actuarial 5-year rate, 97%), 96% (actuarial 5-year rate, 93%), 95% (actuarial 5-year rate, 92%), 92% (actuarial 5-year rate, 89%), and 95% (actuarial 5-year rate, 91%), respectively. Conclusion: We found a greater rate of utilization adjuvant breast RT (85%) among black women after BCS than has been reported in recent studies, indicating that excellent outcomes are attainable for black women after BCS when care is administered in a multidisciplinary cancer center.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in the Utilization of Adjuvant Vaginal Cuff Brachytherapy and/or External Beam Radiation Treatment in Stage I and II Endometrial Cancer: A Surveillance, Epidemiology, and End-Results Study

Purpose: The optimal adjuvant radiation treatment for endometrial carcinoma (EC) remains controversial. Adjuvant vaginal cuff brachytherapy (VB) has emerged as an increasingly common treatment modality. However, the time trends for using VB, external beam radiation therapy (EBRT), or combined therapy (VB+EBRT) have not been well characterized. We therefore examined the utilization trends of VB, EBRT, and VB+EBRT for adjuvant RT in International Federation of Gynecologic Oncology (FIGO) stage I and II EC over time. Methods and Materials: We evaluated treatment patterns for 48,122 patients with EC diagnosed between January 1995 and December 2005, using the National Cancer Institute's Surveillance, Epidemiology, and End Results (SEER) public use database. Chi-squared tests were used to assess differences by radiation type (VB, EBRT, and VB+EBRT) and various demographic and clinical variables. Results: Analyses were limited to 9,815 patients (20.4%) with EC who met the inclusion criteria. Among women who received adjuvant RT, the proportion receiving VB increased yearly (12.9% in 1995 compared to 32.8% in 2005 (p < 0.0001). The increasing use of VB was proportional to the decreasing use of EBRT (56.1% in 1995 to 45.8% in 2005; p < 0.0001) and VB+EBRT (31.0% in 1995 to 21.4% in 2005; p < 0.001). Conclusions: This population-based report demonstrates an increasing trend in the use of VB in the adjuvant setting after hysterectomy for treatment of women with FIGO stage I-II EC. VB alone appears to be replacing pelvic EBRT and VB+EBRT therapy in the management of stage I-II EC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Utility of Cell Cycle Progression Score in Men With Prostate Cancer After Primary External Beam Radiation Therapy

Purpose: To evaluate the prognostic utility of the cell cycle progression (CCP) score, a RNA signature based on the average expression level of 31 CCP genes, for predicting biochemical recurrence (BCR) in men with prostate cancer treated with external beam radiation therapy (EBRT) as their primary curative therapy. Methods and Materials: The CCP score was derived retrospectively from diagnostic biopsy specimens of men diagnosed with prostate cancer from 1991 to 2006 (n=141). All patients were treated with definitive EBRT; approximately half of the cohort was African American. Outcome was time from EBRT to BCR using the Phoenix definition. Median follow-up for patients without BCR was 4.8 years. Association with outcome was evaluated by Cox proportional hazards survival analysis and likelihood ratio tests. Results: Of 141 patients, 19 (13%) had BCR. The median CCP score for patient samples was 0.12. In univariable analysis, CCP score significantly predicted BCR (P=.0017). The hazard ratio for BCR was 2.55 for 1-unit increase in CCP score (equivalent to a doubling of gene expression). In a multivariable analysis that included Gleason score, prostate-specific antigen, percent positive cores, and androgen deprivation therapy, the hazard ratio for CCP changed only marginally and remained significant (P=.034), indicating that CCP provides prognostic information that is not provided by standard clinical parameters. With 10-year censoring, the CCP score was associated with prostate cancer-specific mortality (P=.013). There was no evidence for interaction between CCP and any clinical variable, including ethnicity. Conclusions: Among men treated with EBRT, the CCP score significantly predicted outcome and provided greater prognostic information than was available with clinical parameters. If validated in a larger cohort, CCP score could identify high-risk men undergoing EBRT who may need more aggressive therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions: DIR accuracy in the data sets studied was variable depending on anatomic changes resulting from radiation therapy; caution must be exercised when using DIR in regions of low contrast or radiation pneumonitis. Lung perfusion reduces with increasing radiation therapy dose; however, DIR did not translate into significant changes in dose–response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variations in Medicare Reimbursement in Radiation Oncology: An Analysis of the Medicare Provider Utilization and Payment Data Set

Purpose: The purposes of this study were to summarize recently published data on Medicare reimbursement to individual radiation oncologists and to identify the causes of variation in Medicare reimbursement in radiation oncology. Methods and Materials: The Medicare Provider Utilization and Payment Data: Physician and Other Supplier Public Use File (POSPUF), which details nearly all services provided by radiation oncologists in 2012, was used for this study. The data were filtered and analyzed by physician and by billing code. Statistical analysis was performed to identify differences in reimbursements based on sex, rurality, billing of technical services, or location in a certificate of need (CON) state. Results: There were 4135 radiation oncologists who received a total of $1,499,625,803 in payments from Medicare in 2012. Seventy-five percent of radiation oncologists were male. The median reimbursement was $146,453. The code with the highest total reimbursement was 77418 (radiation treatment delivery intensity modulated radiation therapy [IMRT]). The most commonly billed evaluation and management (E/M) code for new visits was 99205 (49%). The most commonly billed E/M code for established visits was 99213 (54%). Forty percent of providers billed none of their new office visits using 99205 (the highest E/M billing code), whereas 34% of providers billed all of their new office visits using 99205. For the 1510 radiation oncologists (37%) who billed technical services, median Medicare reimbursement was $606,008, compared with $93,921 for all other radiation oncologists (P<.001). On multivariate analysis, technical services billing (P<.001), male sex (P<.001), and rural location (P=.007) were predictive of higher Medicare reimbursement. Conclusions: The billing of technical services, with their high capital and labor overhead requirements, limits any comparison in reimbursement between individual radiation oncologists or between radiation oncologists and other specialists. Male sex and rural practice location are independent predictors of higher total Medicare reimbursements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in Local Therapy Utilization and Cost for Early-Stage Breast Cancer in Older Women: Implications for Payment and Policy Reform

Purpose: Older women with early-stage disease constitute the most rapidly growing breast cancer demographic, yet it is not known which local therapy strategies are most favored by this population in the current era. Understanding utilization trends and cost of local therapy is important for informing the design of bundled payment models as payers migrate away from fee-for-service models. We therefore used the Surveillance, Epidemiology, and End Results Medicare database to determine patterns of care and costs for local therapy among older women with breast cancer. Methods and Materials: Treatment strategy and covariables were determined in 55,327 women age ≥66 with Tis-T2N0-1M0 breast cancer who underwent local therapy between 2000 and 2008. Trends in local therapy were characterized using Joinpoint. Polychotomous logistic regression determined predictors of local therapy. The median aggregate cost over the first 24 months after diagnosis was determined from Medicare claims through 2010 and reported in 2014 dollars. Results: The median age was 75. Local therapy distribution was as follows: 27,896 (50.3%) lumpectomy with external beam radiation, 18,356 (33.1%) mastectomy alone, 6159 (11.1%) lumpectomy alone, 1488 (2.7%) mastectomy with reconstruction, and 1455 (2.6%) lumpectomy with brachytherapy. Mastectomy alone declined from 39.0% in 2000 to 28.2% in 2008, and the use of breast conserving local therapies rose from 58.7% to 68.2%. Mastectomy with reconstruction was more common among the youngest, healthiest patients, whereas mastectomy alone was more common among patients living in rural low-income regions. By 2008, the costs were $36,749 for lumpectomy with brachytherapy, $35,030 for mastectomy with reconstruction, $31,388 for lumpectomy with external beam radiation, $21,993 for mastectomy alone, and $19,287 for lumpectomy alone. Conclusions: The use of mastectomy alone in older women declined in favor of breast conserving strategies between 2000 and 2008. Using these cost estimates, price points for local therapy bundles can be constructed to incentivize the treatment strategies that confer the highest value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing Anesthesia and Health Care Cost Through Utilization of Child Life Specialists in Pediatric Radiation Oncology

Purpose: To analyze the effectiveness of a certified child life specialist (CCLS) in reducing the frequency of daily anesthesia at our institution, and to quantify the potential health care payer cost savings of CCLS utilization in the United States. Methods and Materials: From 2006 to 2014, 738 children (aged ≤21 years) were treated with radiation therapy at our institution. We retrospectively analyzed the frequency of daily anesthesia before and after hiring a CCLS in 2011 after excluding patients aged 0 to 2 and >12 years. In the analyzed cohort of 425 patients the median age was 7.6 years (range, 3-12.9 years). For the pre-CCLS period the overall median age was 7.5 years; for the post-CCLS period the median age was 7.7 years. An average 6-week course of pediatric anesthesia for radiation therapy costs $50,000 in charges to the payer. The average annual cost to employ one CCLS is approximately $50,000. Results: Before employing a CCLS, 69 of 121 children (57%) aged 3 to 12 years required daily anesthesia, including 33 of 53 children (62.3%) aged 5 to 8 years. After employing a CCLS, 124 of 304 children (40.8%) aged 3 to 12 years required daily anesthesia, including only 34 of 118 children (28.8%) aged 5 to 8 years (P<.0001). With a >16% absolute reduction in anesthesia use after employment of a CCLS, the health care payer cost savings was approaching $50,000 per 6 children aged 3 to 12 years treated annually with radiation therapy in our institution. This reduction resulted in a total of only 6 children aged 3 to 12 years required anesthesia to be treated per year at our center to achieve nearly break-even cost savings to the health care payer if the payer were to subsidize the employment expense of a CCLS. Overall, the CCLS intervention can provide an average annualized health care payer cost savings of “$[(anesthesia cost to payer during radiation therapy course/6) − (CCLS expense to payer/N)]” per child (N) treated with radiation therapy, where N equals the number of children aged 3 to 12 years treated in 1 year. This formula assumes that the payer subsidizes the cost for the employment of a CCLS, although our institution absorbed this expense for this data cohort. The predicted annualized health care system cost savings from reducing the frequency of anesthesia with radiation therapy when treating 100 children aged 3 to 12 years per year could exceed $775,000. Conclusions: These data suggest that a CCLS significantly reduces the frequency of daily anesthesia for children treated with radiation therapy. Health care system payers may achieve significant cost savings by financially supporting the employment of a CCLS in high-volume pediatric radiation therapy centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Circulating MicroRNA-150 for Rapid Evaluation of Bone Marrow Depletion After Radiation and Efficiency of Bone Marrow Reconstitution

Total body irradiation (TBI) is a common myeloablative preparative regimen used in acute myeloid and lymphoblastic leukemia patients before allogenic hematopoietic stem cell transplantation (HSCT). The inefficient clearance of tumor cells and radiation-induced toxicity to normal tissues is attributed to relapse and morbidity in a significant fraction of patients. Developing biomarkers that indicate an individual's physiological response to radiation will allow personalized treatment and follow-up. We investigated the utility of circulating microRNA150-5p (miR150) for evaluation of radiation dose response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilizing lowly-reactive coal gasification fly ash (CGFA) to stabilize aggregate bases

This study explored the feasibility of utilizing lowly-reactive coal gasification fly ash (CGFA) for stabilizing road aggregate bases. Three types of aggregate stabilizers including the ordinary Portland cement (OPC)-CGFA, hydrated lime (CH)-CGFA and alkali-activated CH-CGFA were evaluated based on the performances of compacted base specimens. It was found that the OPC-CGFA stabilized bases showed better mechanical and durability properties while the CH-CGFA samples had low water stability and freeze-thaw durability due to the dissolution of unreacted CH. However, the reaction degree of CGFA associated with the performances of CH-CGFA stabilization could be considerably enhanced by the alkali-activation. The sustainability and economic feasibility analyses showed the use of CGFA could significantly reduce the CO 2 emissions and costs, highlighting the synergy between the recycling of CGFA and the construction of sustainable road bases. Here, a framework of selecting CGFA-based stabilizers for road bases was proposed considering the performance ratings of the material properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the utility of GPU accelerated high-order methods for unsteady flow simulations: A comparison with industry-standard tools

First- and second-order accurate numerical methods, implemented for CPUs, underpin the majority of industrial CFD solvers. Whilst this technology has proven very successful at solving steady-state problems via a Reynolds Averaged Navier–Stokes approach, its utility for undertaking scale-resolving simulations of unsteady flows is less clear. High-order methods for unstructured grids and GPU accelerators have been proposed as an enabling technology for unsteady scale-resolving simulations of flow over complex geometries. In this study we systematically compare accuracy and cost of the high-order Flux Reconstruction solver PyFR running on GPUs and the industry-standard solver STAR-CCM+ running on CPUs when applied to a range of unsteady flow problems. Specifically, we perform comparisons of accuracy and cost for isentropic vortex advection (EV), decay of the Taylor–Green vortex (TGV), turbulent flow over a circular cylinder, and turbulent flow over an SD7003 aerofoil. We consider two configurations of STAR-CCM+: a second-order configuration, and a third-order configuration, where the latter was recommended by CD-adapco for more effective computation of unsteady flow problems. Results from both PyFR and STAR-CCM+ demonstrate that third-order schemes can be more accurate than second-order schemes for a given cost e.g. going from second- to third-order, the PyFR simulations of the EV and TGV achieve 75× and 3× error reduction respectively for the same or reduced cost, and STAR-CCM+ simulations of the cylinder recovered wake statistics significantly more accurately for only twice the cost. Moreover, advancing to higher-order schemes on GPUs with PyFR was found to offer even further accuracy vs. cost benefits relative to industry-standard tools.

97 MATHEMATICS AND COMPUTING↗

Development of a chemical-free process utilizing ozone oxidative precipitation for the recovery of cobalt and manganese from acid mine drainage

Acid mine drainage (AMD) has been identified as a viable secondary resource of Co, and Mn. However, recovery of these elements while treating AMD is challenging due to the unfavorable pH and Eh conditions for Co-Mn precipitation. This study investigated the effects of various ligands (hydroxide, carbonate, ammonium, sulfate, and phosphate) and oxidizers (sodium persulfate, potassium permanganate, and ozone) on the precipitation of Co-Mn from AMD through experimental and solution chemistry studies. Ozone was found to be the most effective agent for the recovery of these elements. Based on the results, an AMD treatment process was formulated for selective recovery of multiple critical elements, including Al, REEs, Co, and Mn. More than 95 % of Co and Mn were recovered through the proposed process utilizing chemical-less ozone oxidative precipitation. In conclusion, a precipitate containing 0.9 % Co and 54.6 % Mn was obtained from an AMD source containing 0.9 ppm Co and 41.8 ppm Mn.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilizing bimetallic catalysts to mitigate coke formation in dry reforming of methane

We report dry reforming of methane (DRM) involves the conversion of carbon dioxide (CO 2 ) and methane (CH 4 ) into syngas (a mixture of hydrogen, H 2 , and carbon monoxide, CO), which can then be used to produce a wide range of products by means of Fischer-Tropsch synthesis. DRM has gained much attention as a means of mitigating damage from anthropogenic greenhouse gas (GHGs) emissions to the environment and instead utilizing these gases as precursors for value-added chemicals or to synthesize sustainable fuels and chemicals. Carbon deposition or coke formation, a primary cause of catalyst deactivation, has proven to be a major challenge in the development of DRM catalysts. The use of nickel- and cobalt-based catalysts has been extensively explored for DRM for their high activity and low cost but suffer from poor stability due to coke formation that has hindered their commercialization. Numerous articles have reviewed the various aspects of catalyst deactivation and strategies for mitigation, but few has focused on the benefit of bimetallic catalysts for mitigating coke formation. Bimetallic catalysts, often improve the catalytic stability over their monometallic counterparts due to synergistic effects resulting from two metal-to-metal interactions. This review will cover DRM literature for various bimetallic catalyst systems, including the effect of supports and promoters, on the mitigation of carbonaceous deactivation

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical Tomotherapy

The purpose of this study was to demonstrate the potential utility of megavoltage fan-beam computed tomography (MV-FBCT) for treatment planning in a patient undergoing helical tomotherapy for nasopharyngeal carcinoma in the presence of extensive dental artifact. A 28-year-old female with locally advanced nasopharyngeal carcinoma presented for radiation therapy. Due to the extensiveness of the dental artifact present in the oral cavity kV-CT scan acquired at simulation, which made treatment planning impossible on tomotherapy planning system, MV-FBCT imaging was obtained using the HI-ART tomotherapy treatment machine, with the patient in the treatment position, and this information was registered with her original kV-CT scan for the purposes of structure delineation, dose calculation, and treatment planning. To validate the feasibility of the MV-FBCT-generated treatment plan, an electron density CT phantom (model 465, Gammex Inc., Middleton, WI) was scanned using MV-FBCT to obtain CT number to density table. Additionally, both a 'cheese' phantom (which came with the tomotherapy treatment machine) with 2 inserted ion chambers and a generic phantom called Quasar phantom (Modus Medical Devices Inc., London, ON, Canada) with one inserted chamber were used to confirm dosimetric accuracy. The MV-FBCT could be used to clearly visualize anatomy in the region of the dental artifact and provide sufficient soft-tissue contrast to assist in the delineation of normal tissue structures and fat planes. With the elimination of the dental artifact, the MV-FBCT images allowed more accurate dose calculation by the tomotherapy system. It was confirmed that the phantom material density was determined correctly by the tomotherapy MV-FBCT number to density table. The ion chamber measurements agreed with the calculations from the MV-FBCT generated phantom plan within 2%. MV-FBCT may be useful in radiation treatment planning for nasopharyngeal cancer patients in the setting of extensive dental artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Understanding the impact of the gas diffusion layer structure on catalyst utilization in the PEM water electrolyzer

A multiphysics half-cell model of a polymer electrolyte membrane water electrolyzer (PEMWE) was developed to probe impacts of the detailed 3-dimensional pore structure of the gas diffusion layer (GDL) on performance characteristics. We show that pores in the titanium GDL mesh led to significant underutilization of the catalyst layer (CL), with only 45% of the catalyst effectively utilized. This contradicts the assumption of uniform electron flow across the CL, as shown in graphical abstract (a), as near-zero current was observed near GDL pore regions and the current distribution in CL was influenced by GDL structure, as shown in graphical abstract (b). Instead, oxygen generation was primarily concentrated under the solid titanium regions, diffusing out around the pore walls. High current density peaks were also noted at the GDL-catalyst contact, correlating with degradation hotspots that were directly observed in companion experiments, as shown in graphical abstract (c). Collectively, these findings point to the critical importance of the heterogeneous GDL porous architecture not only for PEMWE efficiency but also for uneven degradation of the CL.

COMSOL↗