Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Threshold Estimate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

SU-E-T-261: Development of An Automated System to Detect Patient Identification and Positioning Errors Prior to Radiotherapy Treatment

Purpose: To develop a system that can automatically detect patient identification and positioning errors using 3D computed tomography (CT) setup images and kilovoltage CT (kVCT) planning images. Methods: Planning kVCT images were collected for head-and-neck (H&N), pelvis, and spine treatments with corresponding 3D cone-beam CT (CBCT) and megavoltage CT (MVCT) setup images from TrueBeam and TomoTherapy units, respectively. Patient identification errors were simulated by registering setup and planning images from different patients. Positioning errors were simulated by misaligning the setup image by 1cm to 5cm in the six anatomical directions for H&N and pelvis patients. Misalignments for spine treatments were simulated by registering the setup image to adjacent vertebral bodies on the planning kVCT. A body contour of the setup image was used as an initial mask for image comparison. Images were pre-processed by image filtering and air voxel thresholding, and image pairs were assessed using commonly-used image similarity metrics as well as custom -designed metrics. A linear discriminant analysis classifier was trained and tested on the datasets, and misclassification error (MCE), sensitivity, and specificity estimates were generated using 10-fold cross validation. Results: Our workflow produced MCE estimates of 0.7%, 1.7%, and 0% for H&N, pelvis, and spine TomoTherapy images, respectively. Sensitivities and specificities ranged from 98.0% to 100%. MCEs of 3.5%, 2.3%, and 2.1% were obtained for TrueBeam images of the above sites, respectively, with sensitivity and specificity estimates between 96.2% and 98.4%. MCEs for 1cm H&N/pelvis misalignments were 1.3/5.1% and 9.1/8.6% for TomoTherapy and TrueBeam images, respectively. 2cm MCE estimates were 0.4%/1.6% and 3.1/3.2%, respectively. Vertebral misalignment MCEs were 4.8% and 4.9% for TomoTherapy and TrueBeam images, respectively. Conclusion: Patient identification and gross misalignment errors can be robustly and automatically detected using 3D setup images of two imaging modalities across three commonly-treated anatomical sites.

60 APPLIED LIFE SCIENCES↗

Investigation of a nonequilibrium polariton condensate in cylindrical micropillars in a strong magnetic field

We analyze the photoluminescence of a nonequilibrium polariton condensate in cylindrical micropillars etched on the surface of a high-Q GaAs microcavity in a wide range of detunings in a magnetic field up to 12 T for various levels of nonresonant laser pumping by nanosecond pulses. With such a method of excitation, a considerable effect of the interaction of the reservoir of photoexcited excitons with the condensate on the Zeeman splitting of the polariton condensate levels can be expected, which can lead to a decrease in its value and even to sign reversal. However, the measurements of photoluminescence in a wide range of optical excitation densities show that Zeeman splitting weakly depends on the optical pumping (its variation does not exceed 15% of the splitting in a field of 12 T). The estimation of the exciton density in the reservoir based on these data gives a value lower than 10{sup 8} cm{sup –2}. In addition, a noticeable decrease (by a factor of about 1.8) in the polariton condensation threshold in a magnetic field is detected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review and Summary of Corrosion Behavior for Aluminum-Clad Spent Nuclear Fuel in Dry Storage

A description of the corrosion behavior of aluminum alloys used for cladding on aluminum-based, aluminum-clad nuclear fuel used in research reactors under potential dry storage conditions has been compiled. An evaluation is made of potential additional corrosion with water postulated to not be removed during drying. The relative humidity (RH) produced by typical dryness criteria for industrial spent nuclear fuel drying is expected to be low, particularly at high temperatures (17% RH at 20°C and lower at higher temperatures). Existing corrosion data suggests that negligible vapor-phase corrosion of aluminum is expected at such low humidity, even for nominally bare aluminum surfaces. That is, the predicted relative humidity from free water (e.g., 17% RH) is below the “critical” relative humidity (~40% RH at room temperature), below which no significant corrosion is observed for bare aluminum. Furthermore, reported room-temperature corrosion rates are very low even under saturated (100% RH) water vapor. Existing results showing significant vapor-phase corrosion corresponded specifically to conditions of high temper ed with high relative humidity. A relatively large reservoir of (chemically bound) water exists in the aluminum (oxy)hydroxide films on the SNF cladding surface. The estimated total could saturate the gas even at relatively high temperature if fully released; however, its release as molecular water is expected to only be plausible if the temperature during storage exceeds both the drying temperature and the threshold for thermal decomposition of the trihydroxides (~220°C). Therefore, the combination of high temperature and high relative humidity that could drive significant corrosion is considered implausible during sealed dry storage following an appropriate drying process, to include >220°C drying for canisters that may approach or exceed this temperature during storage. Vapor-phase testing of aluminum samples with an adherent (oxy)hydroxide layer, prepared in liquid water to resemble those on actual aluminum-clad spent nuclear fuel (ASNF), did not observe evidence of additional corrosion even at combined high-temperature (up to 180°C) and high-humidity (up to 100% RH) conditions. Instead, small net mass losses were observed for most specimens and attributed to dehydration of the samples, which had been air-dried only prior to testing. ASNF being moved to dry storage is expected to have an existing (oxy)hydroxide film, suggesting that the cladding will be less prone to additional corrosion than bare aluminum metal. If significant corrosion did occur during sealed storage, the overall extent and impact is expected to be small. Corrosion post-closure of a canister would not alter the total amount of hydrogen in the canister, so it would have no effect on the maximum H 2 release already assessed in existing bounding calculations. In addition, the total amount of water in a 25-µm dense bayerite film would consume a only ~8 µm additional aluminum metal on average, if fully consumed by oxidizing aluminum metal to Al 2 O 3 . These conclusions are consistent with ASNF-in-canister simulations to date, which included a reaction pathway for corrosion using kinetics from previous literature and believed to be conservative and predicted very low rates of corrosion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conductor fusing and gapping for bond wires

In this paper, fusing of a metallic conductor is studied by judiciously using the solution of the one-dimensional heat equation, resulting in an approximate method for determining the threshold fusing current. The action is defined as an integration of the square of the wire current over time. The burst action (the action required to completely vaporize the material) for an exploding wire is then used to estimate the typical wire gapping action (involving wire fusing), from which gapping time can be estimated for a gapping current greater than a factor of two over the fusing current. The test data are used to determine the gapped length as a function of gapping current and to show, for a limited range, that the gapped length is inversely proportional to gapping time. The gapping length can be used as a signature of the fault current level in microelectronic circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of electron detection efficiencies in solid state detectors.

Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

Lupton, J. E.↗

Convection phenomena during the growth of sodium chlorate crystals from solution

The paper examines convection phenomena during the growth of sodium chlorate crystals from solution. Schlieren observations of sodium chlorate crystals suspended in supersaturated solutions showed that with increase in supersaturation or crystal size, the boundary layer on the side faces was stable while the top boundary layer and emerging plume changed from stable to partially oscillatory. The transition was a function of the Grashof number, Gr sub top, and the crystal height. Gr sub top correlated with plume width, number of streamlines, eddy density, and plume velocity, but the oscillation period correlated with the weight increase growth rate. The mass transfer rate, the linear growth rate, and growth of vertical and horizontal faces are discussed, and an estimate of boundary layer flow vs growth rate for near-critical stable convection indicated that growth of side faces depleted over half of the excess solute in the boundary layer. Impulse energies greatly in excess of the threshold value caused transient separation of the boundary layer on the top face, and plume wavering due to background-induced fluid motion was observed only at the lowest supersaturations.

Chen, P. S.↗

Symbol lock detection in the ARX 2 and Block 5 receivers

The performances of 5 symbol-lock detectors are compared. These detectors are the square-law detector with overlapping (SQOD) and nonoverlapping integrators, the absolute-value detectors with overlapping and nonoverlapping integrators, and the signal-power estimator detector (SPED). The analysis considers various scenarios in which the observation interval is much larger than or equal to the symbol-synchronizer loop bandwidth, and which were not considered in previous analyses. Also, the case of threshold setting in the absence of signal is considered. It is shown, that the SQOD outperforms all others when the threshold is set in the presence of a signal, independent of the relationship between loop bandwidth and observation period. On the other hand, the SPED outperforms all others when the threshold is set in the presence of noise only.

Shihabi, M.↗

Sensor Fault Detection and Diagnosis Simulation of a Helicopter Engine in an Intelligent Control Framework

This paper presents an application of a fault detection and diagnosis scheme for the sensor faults of a helicopter engine. The scheme utilizes a model-based approach with real time identification and hypothesis testing which can provide early detection, isolation, and diagnosis of failures. It is an integral part of a proposed intelligent control system with health monitoring capabilities. The intelligent control system will allow for accommodation of faults, reduce maintenance cost, and increase system availability. The scheme compares the measured outputs of the engine with the expected outputs of an engine whose sensor suite is functioning normally. If the differences between the real and expected outputs exceed threshold values, a fault is detected. The isolation of sensor failures is accomplished through a fault parameter isolation technique where parameters which model the faulty process are calculated on-line with a real-time multivariable parameter estimation algorithm. The fault parameters and their patterns can then be analyzed for diagnostic and accommodation purposes. The scheme is applied to the detection and diagnosis of sensor faults of a T700 turboshaft engine. Sensor failures are induced in a T700 nonlinear performance simulation and data obtained are used with the scheme to detect, isolate, and estimate the magnitude of the faults.

Litt, Jonathan↗

FPGA-Based X-Ray Detection and Measurement for an X-Ray Polarimeter

This technology enables detection and measurement of x-rays in an x-ray polarimeter using a field-programmable gate array (FPGA). The technology was developed for the Gravitational and Extreme Magnetism Small Explorer (GEMS) mission. It performs precision energy and timing measurements, as well as rejection of non-x-ray events. It enables the GEMS polarimeter to detect precisely when an event has taken place so that additional measurements can be made. The technology also enables this function to be performed in an FPGA using limited resources so that mass and power can be minimized while reliability for a space application is maximized and precise real-time operation is achieved. This design requires a low-noise, charge-sensitive preamplifier; a highspeed analog to digital converter (ADC); and an x-ray detector with a cathode terminal. It functions by computing a sum of differences for time-samples whose difference exceeds a programmable threshold. A state machine advances through states as a programmable number of consecutive samples exceeds or fails to exceed this threshold. The pulse height is recorded as the accumulated sum. The track length is also measured based on the time from the start to the end of accumulation. For track lengths longer than a certain length, the algorithm estimates the barycenter of charge deposit by comparing the accumulator value at the midpoint to the final accumulator value. The design also employs a number of techniques for rejecting background events. This innovation enables the function to be performed in space where it can operate autonomously with a rapid response time. This implementation combines advantages of computing system-based approaches with those of pure analog approaches. The result is an implementation that is highly reliable, performs in real-time, rejects background events, and consumes minimal power.

Gregory, Kyle↗

A behavior and physiology-based decision support tool to predict thermal comfort and stress in non-pregnant, mid-gestation, and late-gestation sows

Background: Although thermal indices have been proposed for swine, none to our knowledge differentiate by reproductive stage or predict thermal comfort using behavioral and physiological data. The study objective was to develop a behavior and physiology-based decision support tool to predict thermal comfort and stress in multiparous (3.28 ± 0.81) non-pregnant (n = 11), mid-gestation (n = 13), and late-gestation (n = 12) sows. Results: Regression analyses were performed using PROC MIXED in SAS 9.4 to determine the optimal environmental indicator [dry bulb temperature (T DB ) and dew point] of heat stress (HS) in non-pregnant, mid-gestation, and late-gestation sows with respiration rate (RR) and body temperature (T B ) successively used as the dependent variable in a cubic function. A linear relationship was observed for skin temperature (T S ) indicating that TDB rather than the sow HS response impacted TS and so TS was excluded from further analyses. Reproductive stage was significant for all analyses (P < 0.05). Heat stress thresholds for each reproductive stage were calculated using the inflections points of RR for mild HS and T B for moderate and severe HS. Mild HS inflection points differed for non-pregnant, mid-gestation, and late gestation sows and occurred at 25.5, 25.1, and 24.0 °C, respectively. Moderate HS inflection points differed for non-pregnant, mid-gestation, and late gestation sows and occurred at 28.1, 27.8, and 25.5 °C, respectively. Severe HS inflection points were similar for non-pregnant and mid-gestation sows (32.9 °C) but differed for late-gestation sows (30.8 °C). These data were integrated with previously collected behavioral thermal preference data to estimate the T DB that non-pregnant, mid-gestation, and late-gestation sows found to be cool (T DB < T DB preference range), comfortable (T DB = T DB preference range), and warm (T DB preference range < T DB < mild HS). Conclusions: The results of this study provide valuable information about thermal comfort and thermal stress thresholds in sows at three reproductive stages. The development of a behavior and physiology-based decision support tool to predict thermal comfort and stress in non-pregnant, mid-gestation, and late-gestation sows is expected to provide swine producers with a more accurate means of managing sow environments.

59 BASIC BIOLOGICAL SCIENCES↗

Identification of robust microsatellite markers for wild pig fecal DNA

ABSTRACT Collection of fecal samples for use in a genetic capture‐mark‐recapture framework has become popular as a noninvasive method of monitoring wildlife populations. A major caveat to this process, however, is that fecal samples often yield low quality DNA that is prone to genotyping errors, potentially leading to biases in population parameter estimation. Therefore, considerable care is required to identify robust genetic markers, especially in hot or humid conditions that may accelerate DNA degradation. We identified microsatellite loci in wild pig ( Sus scrofa ) fecal samples that were robust and informative within warm, humid ecosystems. To examine how degradation affected genotyping success, we sampled pig feces across 5 days and calculated how the number of quantitative polymerase chain reaction (qPCR) cycles required to reach the fluorescent threshold ( C t ) changed over time. We identified 17 microsatellite loci that had high polymorphism and amplification success and low genotyping error rates (0–0.050 per locus). In the degradation experiment, C t increased over the 5 days, but in the absence of rain, the majority of samples produced accurate genotypes after 5 days (2,211/2,550 genotypes). Based on the high amplification success and low error rates, even after 5 days of exposure to warm, humid conditions, these loci are useful for estimating population parameters in pig fecal samples. © 2016 The Wildlife Society.

Kierepka, Elizabeth M.↗

Geochemical Fingerprinting of Coltan Ores by Machine Learning on Uneven Datasets

Two modern machine learning techniques, Linear Programming Boosting (LPBoost) and Support Vector Machines (SVMs), are introduced and applied to a geochemical dataset of niobium-tantalum ('coltan') ores from Central Africa to demonstrate how such information may be used to distinguish ore provenance, i.e., place of origin. The compositional data used include uni- and multivariate outliers and elemental distributions are not described by parametric frequency distribution functions. The 'soft margin' techniques of LPBoost and SVMs can be applied to such data. Optimization of their learning parameters results in an average accuracy of up to c. 92%, if spot measurements are assessed to estimate the provenance of ore samples originating from two geographically defined source areas. A parameterized performance measure, together with common methods for its optimization, was evaluated to account for the presence of uneven datasets. Optimization of the classification function threshold improves the performance, as class importance is shifted towards one of those classes. For this dataset, the average performance of the SVMs is significantly better compared to that of LPBoost.

42 ENGINEERING↗

Safety assessment of personal care products/cosmetics and their ingredients

We attempt to review the safety assessment of personal care products (PCP) and ingredients that are representative and pose complex safety issues. PCP are generally applied to human skin and mainly produce local exposure, although skin penetration or use in the oral cavity, on the face, lips, eyes and mucosa may also produce human systemic exposure. In the EU, US and Japan, the safety of PCP is regulated under cosmetic and/or drug regulations. Oxidative hair dyes contain arylamines, the most chemically reactive ingredients of PCP. Although arylamines have an allergic potential, taking into account the high number of consumers exposed, the incidence and prevalence of hair dye allergy appears to be low and stable. A recent (2001) epidemiology study suggested an association of oxidative hair dye use and increased bladder cancer risk in consumers, although this was not confirmed by subsequent or previous epidemiologic investigations. The results of genetic toxicity, carcinogenicity and reproductive toxicity studies suggest that modern hair dyes and their ingredients pose no genotoxic, carcinogenic or reproductive risk. Recent reports suggest that arylamines contained in oxidative hair dyes are N-acetylated in human or mammalian skin resulting in systemic exposure to traces of detoxified, i.e. non-genotoxic, metabolites, whereas human hepatocytes were unable to transform hair dye arylamines to potentially carcinogenic metabolites. An expert panel of the International Agency on Research of Cancer (IARC) concluded that there is no evidence for a causal association of hair dye exposure with an elevated cancer risk in consumers. Ultraviolet filters have important benefits by protecting the consumer against adverse effects of UV radiation; these substances undergo a stringent safety evaluation under current international regulations prior to their marketing. Concerns were also raised about the safety of solid nanoparticles in PCP, mainly TiO{sub 2} and ZnO in sunscreens. However, current evidence suggests that these particles are non-toxic, do not penetrate into or through normal or compromised human skin and, therefore, pose no risk to human health. The increasing use of natural plant ingredients in personal care products raised new safety issues that require novel approaches to their safety evaluation similar to those of plant-derived food ingredients. For example, the Threshold of Toxicological Concern (TTC) is a promising tool to assess the safety of substances present at trace levels as well as minor ingredients of plant-derived substances. The potential human systemic exposure to PCP ingredients is increasingly estimated on the basis of in vitro skin penetration data. However, new evidence suggests that the in vitro test may overestimate human systemic exposure to PCP ingredients due to the absence of metabolism in cadaver skin or misclassification of skin residues that, in vivo, remain in the stratum corneum or hair follicle openings, i.e. outside the living skin. Overall, today's safety assessment of PCP and their ingredients is not only based on science, but also on their respective regulatory status as well as other issues, such as the ethics of animal testing. Nevertheless, the record shows that today's PCP are safe and offer multiple benefits to quality of life and health of the consumer. In the interest of all stakeholders, consumers, regulatory bodies and producers, there is an urgent need for an international harmonization on the status and safety requirements of these products and their ingredients.

60 APPLIED LIFE SCIENCES↗

REPRODUCING THE STELLAR MASS/HALO MASS RELATION IN SIMULATED {Lambda}CDM GALAXIES: THEORY VERSUS OBSERVATIONAL ESTIMATES

We examine the present-day total stellar-to-halo mass (SHM) ratio as a function of halo mass for a new sample of simulated field galaxies using fully cosmological, {Lambda}CDM, high-resolution SPH + N-body simulations. These simulations include an explicit treatment of metal line cooling, dust and self-shielding, H{sub 2}-based star formation (SF), and supernova-driven gas outflows. The 18 simulated halos have masses ranging from a few times 10{sup 8} to nearly 10{sup 12} M{sub Sun }. At z = 0, our simulated galaxies have a baryon content and morphology typical of field galaxies. Over a stellar mass range of 2.2 Multiplication-Sign 10{sup 3}-4.5 Multiplication-Sign 10{sup 10} M{sub Sun} we find extremely good agreement between the SHM ratio in simulations and the present-day predictions from the statistical abundance matching technique presented in Moster et al. This improvement over past simulations is due to a number systematic factors, each decreasing the SHM ratios: (1) gas outflows that reduce the overall SF efficiency but allow for the formation of a cold gas component; (2) estimating the stellar masses of simulated galaxies using artificial observations and photometric techniques similar to those used in observations; and (3) accounting for a systematic, up to 30% overestimate in total halo masses in DM-only simulations, due to the neglect of baryon loss over cosmic times. Our analysis suggests that stellar mass estimates based on photometric magnitudes can underestimate the contribution of old stellar populations to the total stellar mass, leading to stellar mass errors of up to 50% for individual galaxies. These results highlight that implementing a realistic high density threshold for SF considerably reduces the overall SF efficiency due to more effective feedback. However, we show that in order to reduce the perceived tension between the SF efficiency in galaxy formation models and in real galaxies, it is very important to use proper techniques to compare simulations with observations.

79 ASTRONOMY AND ASTROPHYSICS↗

A Parametric Study of Erupting Flux Rope Rotation: Modeling the 'Cartwheel CME' on 9 April 2008

The rotation of erupting filaments in the solar corona is addressed through a parametric simulation study of unstable, rotating flux ropes in bipolar force-free initial equilibrium. The Lorentz force due to the external shear-field component and the relaxation of tension in the twisted field are the major contributors to the rotation in this model, while reconnection with the ambient field is of minor importance, due to the field's simple structure. In the low-beta corona, the rotation is not guided by the changing orientation of the vertical field component's polarity inversion line with height. The model yields strong initial rotations which saturate in the corona and differ qualitatively from the profile of rotation vs. height obtained in a recent simulation of an eruption without preexisting flux rope. Both major mechanisms writhe the flux rope axis, converting part of the initial twist helicity, and produce rotation profiles which, to a large part, are very similar within a range of shear-twist combinations. A difference lies in the tendency of twist-driven rotation to saturate at lower heights than shear-driven rotation. For parameters characteristic of the source regions of erupting filaments and coronal mass ejections, the shear field is found to be the dominant origin of rotations in the corona and to be required if the rotation reaches angles of order 90 degrees and higher; it dominates even if the twist exceeds the threshold of the helical kink instability. The contributions by shear and twist to the total rotation can be disentangled in the analysis of observations if the rotation and rise profiles are simultaneously compared with model calculations. The resulting twist estimate allows one to judge whether the helical kink instability occurred. This is demonstrated for the erupting prominence in the "Cartwheel CME" on 9 April 2008, which has shown a rotation of approximately 115 deg. up to a height of 1.5 Solar R above the photosphere. Out of a range of initial equilibria which include strongly kink-unstable (Phi = 5 pi), weakly kink-unstable (Phi = 3.5 pi), and kink-stable (Phi = 2.5 pi) configurations, only the evolution of the weakly kink-unstable flux rope matches the observations in their entirety.

initiation and propagation↗

Metal uptake by homegrown vegetables – The relative importance in human health risk assessments at contaminated sites

Risk assessments of contaminated land often involve the use of generic bioconcentration factors (BCFs), which express contaminant concentrations in edible plant parts as a function of the concentration in soil, in order to assess the risks associated with consumption of homegrown vegetables. This study aimed to quantify variability in BCFs and evaluate the implications of this variability for human exposure assessments, focusing on cadmium (Cd) and lead (Pb) in lettuce and potatoes sampled around 22 contaminated glassworks sites. In addition, risks associated with measured Cd and Pb concentrations in soil and vegetable samples were characterized and a probabilistic exposure assessment was conducted to estimate the likelihood of local residents exceeding tolerable daily intakes. The results show that concentrations in vegetables were only moderately elevated despite high concentrations in soil, and most samples complied with applicable foodstuff legislation. Still, the daily intake of Cd (but not Pb) was assessed to exceed toxicological thresholds for about a fifth of the study population. Bioconcentration factors were found to vary more than indicated by previous studies, but decreasing BCFs with increasing metal concentrations in the soil can explain why the calculated exposure is only moderately affected by the choice of BCF value when generic soil guideline values are exceeded and the risk may be unacceptable. - Highlights: • Uptake of Cd and Pb by lettuce and potatoes increased with soil contamination. • Consumption of homegrown vegetables may lead to a daily Cd intake above TDIs. • The variability in the calculated BCFs is high when compared to previous studies. • Exposure assessments are most sensitive to the choice of BCFs at low contamination.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a parasite-density based pooled targeted amplicon deep sequencing (TADS) method for molecular surveillance of Plasmodium falciparum drug resistance genes in Haiti

Sequencing large numbers of individual samples is often needed for countrywide antimalarial drug resistance surveillance. Pooling DNA from several individual samples is an alternative cost and time saving approach for providing allele frequency (AF) estimates at a population level. Using 100 individual patient DNA samples of dried blood spots from a 2017 nationwide drug resistance surveillance study in Haiti, we compared codon coverage of drug resistance-conferring mutations in four Plasmodium falciparum genes ( crt , dhps , dhfr , and mdr1 ), for the same deep sequenced samples run individually and pooled. Samples with similar real-time PCR cycle threshold (Ct) values (+/- 1.0 Ct value) were combined with ten samples per pool. The sequencing success for samples in pools were higher at a lower parasite density than the individual samples sequence method. The median codon coverage for drug resistance-associated mutations in all four genes were greater than 3-fold higher in the pooled samples than in individual samples. The overall codon coverage distribution for pooled samples was wider than the individual samples. The sample pools with < 40 parasites/μL blood showed more discordance in AF calls for dhfr and mdr1 between the individual and pooled samples. This discordance in AF estimation may be due to low amounts of parasite DNA, which could lead to variable PCR amplification efficiencies. Grouping samples with an estimated ≥ 40 parasites/μL blood prior to pooling and deep sequencing yielded the expected population level AF. Pooling DNA samples based on estimates of > 40 parasites/μL prior to deep sequencing can be used for rapid genotyping of a large number of samples for these four genes and possibly other drug resistant markers in population-based studies. As Haiti is a low malaria transmission country with very few mixed infections and continued chloroquine sensitivity, the pooled sequencing approach can be used for routine national molecular surveillance of resistant parasites.

Louha, Swarnali (ORCID:0000000207778507)↗

Time-Lapse Gravity Monitoring of CO2 Migration Based on Numerical Modeling of a Faulted Storage Complex

In this study, the performance of both surface and borehole time-lapse gravity monitoring to detect CO2 leakage from a carbon storage site is evaluated. Several hypothetical scenarios of CO2 migration in a leaky fault, and thief zones at different depths at the Kimberlina site (California, USA) constitute the basis of the approach. The CO2 displacement is simulated using the TOUGH2 simulator applied to a detailed geological model of the site. The gravity responses to these CO2 plumes are simulated using forward modeling with sensors at ground surface and in vertical boreholes. Results of inversion on one scenario are also presented. The surface-based gravity responses obtained for the different leakage scenarios demonstrate that leakage can be detected at the surface in all the scenarios but the time to detection is highly variable (10 to 40 years) and dependent on the detection threshold considered. Borehole measurements of the vertical component of gravity provide excellent constrains in depth when they are located in proximity of the density anomaly associated with the presence of CO2, thus discriminating multiple leaks in different thief zones. Joint inversion of surface and borehole data can bring valuable information of the occurrence of leakages and their importance by providing a reasonable estimate of mass of displaced fluids. This study demonstrates the importance of combining multiphase flow simulations with gravity modeling in order to define if and when gravity monitoring would be applicable at a given storage site.

Time-lapse gravity monitoring, leak detection, CCS↗