Thermal Analysis and Design of Multi-layer Insulation for Re-entry Aerodynamic Heating

The combined radiation/conduction heat transfer in high-temperature multi-layer insulations was modeled using a finite volume numerical model. The numerical model was validated by comparison with steady-state effective thermal conductivity measurements, and by transient thermal tests simulating re-entry aerodynamic heating conditions. A design of experiments technique was used to investigate optimum design of multi-layer insulations for re-entry aerodynamic heating. It was found that use of 2 mm foil spacing and locating the foils near the hot boundary with the top foil 2 mm away from the hot boundary resulted in the most effective insulation design. A 76.2 mm thick multi-layer insulation using 1, 4, or 16 foils resulted in 2.9, 7.2, or 22.2 percent mass per unit area savings compared to a fibrous insulation sample at the same thickness, respectively.

Daryabeigi, Kamran↗

Use of Several Thermal Analysis Techniques to Study the Cracking of an Nitrile Butadiene Rubber (NBR) Insulator on the Booster Separation Motor (BSM) of the Space Shuttle

Two different vendor rubber formulations have been used to produce the silica-filled NBR insulators for the BSM used on both of the Solid Rocket Boosters (SRBs) of the Space Shuttle. A number of lots of the BSM insulator in 1998-99 exhibited surface cracks and/or crazing. Each insulator is bonded to the BSM aluminum aft closure with an epoxy adhesive. Induced insulator stresses from adhesive cure are likely greatest where the insulator/adhesive contour is the greatest, thus showing increased insulator surface cracking in this area. Thermal analysis testing by Dynamic Mechanical Analyzer (DMA) and Thermomechanical Analysis (TMA) was performed on one each of the two vendor BSM insulators previously bonded that exhibited the surface cracking. The TMA data from the film/fiber technique yielded the most meaningful results, with thin insulator surface samples containing cracks having roughly the same modulus (stiffness) as thin insulator bulk samples just underneath.

Wingard, Charles D.↗

Passive and compact liquid metal heat switch

A passive heat switch device is disclosed that includes a casing defining a closed channel, as well as a passive thermal actuator and liquid slug positioned inside the closed channel. The closed channel includes a heat conducting region made of a heat conducting material and an insulating region made of an insulating material. The passive thermal actuator is thermally coupled to the heat conducting material of the heat conducting region and extends into the insulating region of the closed channel. The passive thermal actuator deforms when an actuator temperature falls within a switching temperature range. The liquid slug is positioned within the closed channel and contacts at least a portion of the passive thermal actuator and the closed channel and is configured to move along the closed channel between the insulating region and the thermally conductive region in response to deformation of the passive thermal actuator.

42 ENGINEERING↗

Advanced leading edge thermal-structure concept. Direct bond reusable surface insulation to a composite structure

An advanced leading-edge concept was analyzed using the space shuttle leading edge system as a reference model. The comparison indicates that a direct-bond system utilizing a high temperature (2700 F) fibrous refractory composite insulation tile bonded to a high temperature (PI/graphite) composite structure can result in a weight savings of up to 800 lb. The concern that tile damage or loss during ascent would result in adverse entry aerodynamics if a leading edge tile system were used is addressed. It was found from experiment that missing tiles (as many as 22) on the leading edge would not significantly affect the basic force-and-moment aerodynamic coefficients. Additionally, this concept affords a degree of redundancy to a thermal protection system in that the base structure (being a composite material) ablates and neither melts nor burns through when subjected to entry heating in the event tiles are actually lost or damaged during ascent.

Riccitiello, S. R.↗

Pneumatic Haptic Interfaces

An instrumentation system for direct measurement of the thermal conductivity of a small sample of a highly insulating material has been devised. As used here, (1) "small" signifies having dimensions of the order of two centimeters - significantly less than the sizes of specimens for which prior devices for direct measurement of thermal conductivity have been designed; and (2) "highly insulating" signifies having thermal conductivity of the order of that of air. The heart of the system is an assembly that includes two copper disks - one electrically heated, the other cooled with chilled water. The disks are separated by a guard ring made of strong, thermally insulating polymethacrylamide foam. The sample fits between the copper disks and within the ring (see figure). Matched thermocouples are used to measure the temperatures of the heated and cooled disks. The heated and cooled disks are affixed to larger foam disks, and the essentially still air in the gap between the larger disks insulates the sides of the specimen. This air gap region can be further divided by extending the foam ring into the gap region. The entire assembly as described thus far is lightly clamped together by means of nylon threaded rods and is placed inside a cylindrical chamber wherein the temperature is maintained at a set value (typically, 25 C).

Bae, Sam Y.↗

Cryogenic Boil-Off Reduction System Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASA's future space exploration due to the high specific impulse that can be achieved using engines suitable for moving 10's to 100's of metric tons of payload mass to destinations outside of low earth orbit. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several days. The losses can be greatly reduced by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and by the integration of self-supporting multi-layer insulation. The active thermal control technology under development is the integration of the reverse turbo- Brayton cycle cryocooler to the propellant tank through a distributed cooling network of tubes coupled to a shield in the tank insulation and to the tank wall itself. Also, the self-supporting insulation technology was utilized under the shield to obtain needed tank applied LH2 performance. These elements were recently tested at NASA Glenn Research Center in a series of three tests, two that reduced LH2 boil-off and one to eliminate LO2 boil-off. This test series was conducted in a vacuum chamber that replicated the vacuum of space and the temperatures of low Earth orbit. The test results show that LH2 boil-off was reduced 60% by the cryocooler system operating at 90K and that robust LO2 zero boil-off storage, including full tank pressure control was achieved.

Propellant Storage↗

Heat transfer in a fissioning uranium plasma reactor cavity

Two schemes are investigated by which a fission-heated uranium plasma located in the central cavity of a test reactor could be insulated to keep its temperature above condensation in a neutron flux of 10 to the 15th power neutrons/(sq cm)(sec) or less. The first scheme was to use a mirrored cavity wall to reflect the thermal radiation back into the plasma. The second scheme was to seed the transpirational cavity wall coolant so as to make it opaque to thermal radiation, thus insulating the hot plasma from the cold wall. The analysis showed that a mirrored cavity wall must have a reflectivity of over 95 percent or that seeded argon must be used as the wall coolant to give an acceptable operating margin above fuel condensation conditions.

Kascak, A. F.↗

Structural concepts for future space transportation orbiters

Two structural concepts for a fully reusable STS orbiter are compared with respect to weight and the ability to satisfy structural goals. The cryogenic propellant tanks for both concepts use welded, blade-stiffened aluminum skins for leak-free containment and compatibility with LOX and LH2. The tanks are sized primarily by pressure, although some areas are sized by bending and fracture mechanics considerations. The tank concept is regarded as state-of-the-art, even though it requires a closed cell foam insulation with a dry air purge to prevent air liquefaction and ice formation. It is noted that the foam will require testing to verify its design life for use in the STS. One concept has nonintegral tanks suspended inside an insulated aluminum airframe and thrust structure. Here, a durable thermal protection system external insulation is mechanically attached to the airframe, allowing a buckled skin design. The other concept uses a novel structural arrangement consisting of a separate tank/thrust structure that supports a hot advanced-carbon-carbon aeroshell structure.

Taylor, A. H.↗

Thermal effects of insolation propagation into the regoliths of airless bodies

The planetary surface thermal models used in the present study are composed of particles which, while bright and optically thin in the visual, are dark and opaque in the thermal IR. It is assumed that insolation is absorbed over a finite regolith distance whose scale length relative to diurnal skin depth for thermal diffusion can be substantial. Attention is given to the lower daytime and higher nighttime temperatures predicted by comparison with models assuming absorption only at the surface. It is noted that, with sufficiently deep penetration of insulation and high thermal IR particle opacity, a solid-state greenhouse can result.

Brown, Robert Hamilton↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Internal insulation and corrosion control of molten chloride thermal energy storage tanks

A chloride-based molten-salt system that uses a ternary blend of MgCl 2 /KCl/NaCl is investigated to provide higher-temperature thermal energy storage capability than conventional nitrate salt-based systems. Despite their high thermal stability and operating temperature, molten chlorides present several challenges, including the design of internal liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the hot face refractory materials for use as internal liners. Furthermore, three down-selected refractory materials were analyzed with respect to permeation of salt through the material as well as chemical stability during high temperature operation. Through the application of X-ray imaging and electron spectroscopy techniques, highly stable secondary surface phases in equilibrium with the molten salt were identified, as well as time-dependent changes in the salt composition itself.

25 ENERGY STORAGE↗

Thermal performance of a modularized replaceable multilayer insulation system for a cryogenic stage

A rugged modularized MLI system for a 2.23-meter-diameter (87.6-in.-diam) liquid hydrogen tank was designed, fabricated, and tested under simulated near-earth and deep-space environments. The two blankets of the system were each composed of 17 double-aluminized Mylar radiation shields separated by silk net. The unit area weight of the installed system was 1.54 kg/sqm (0.32 lb/sq ft). The overall average heat transferred into the insulated tank was 22.7 and 0.98 watts (77.4 and 3.3 Btu/hr) during simulated near-earth and deep-space testing, respectively. The near-earth result was only 2.6 times that predicted for an undisturbed insulation system (i.e., no seams or penetrations). Tests indicate that this insulation concept could be useful for a cryogenic space tug or orbit transfer vehicle application.

Knoll, R. H.↗

Extension of similarity test procedures to cooled engine components with insulating ceramic coatings

Material thermal conductivity was analyzed for its effect on the thermal performance of air cooled gas turbine components, both with and without a ceramic thermal-barrier material, tested at reduced temperatures and pressures. The analysis shows that neglecting the material thermal conductivity can contribute significant errors when metal-wall-temperature test data taken on a turbine vane are extrapolated to engine conditions. This error in metal temperature for an uncoated vane is of opposite sign from that for a ceramic-coated vane. A correction technique is developed for both ceramic-coated and uncoated components.

Gladden, H. J.↗