Technoeconomic optimization of superalloy supercritical CO 2 microtube shell-and-tube-heat exchangers

Heat exchangers are critical components of aerospace systems and improve efficiency of operation by providing waste heat recovery. Supercritical CO has emerged as a promising candidate working fluid due to its potential in increasing the power density of heat exchangers. In this paper, a generalized costing model is developed to estimate the capital costs incurred to manufacture microtube shell-and-tube heat exchangers. This model is utilized in conjunction with an accurate and efficient 2D numerical shell-and-tube heat exchanger performance prediction model to conduct optimization studies with two key objectives – minimization of cost and maximization of heat exchanger power density – on supercritical CO microtube heat exchangers utilizing superalloy Haynes 282 as the solid material. A methodology is then demonstrated to optimize these heat exchangers using Particle Swarm Optimization for aerospace applications and highly compact and cost-effective optimal designs with power density around 20 and cost per conductance less than 5 $ ∙ K/W are obtained.

42 ENGINEERING↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

The autoignition of iso-cetane at high to moderate temperatures and elevated pressures: Shock tube experiments and kinetic modeling

Iso-cetane (2,2,4,4,6,8,8-heptamethylnonane, C{sub 16}H{sub 34}) is a highly branched alkane reference compound for determining cetane ratings. It is also a candidate branched alkane representative in surrogate mixtures for diesel and jet fuels. Here new experiments and kinetic modeling results are presented for the autoignition of iso-cetane at elevated temperatures and pressures relevant to combustion in internal combustion engines. Ignition delay time measurements were made in reflected shock experiments in a heated shock tube for {phi} = 0.5, 1.0, and 1.5 iso-cetane/air mixtures at temperatures ranging from 879 to 1347 K and pressures from 8 to 47 atm. Ignition delay times were measured using electronically excited OH emission, monitored through the shock tube end wall, and piezoelectric pressure transducer measurements, made at side wall locations. A new kinetic mechanism for the description of the oxidation of iso-cetane is presented that is developed based on a previous mechanism for iso-octane. Computed results from the mechanism are found in good agreement with the experimental measurements. To our knowledge, the ignition time measurements for iso-cetane presented here are the first of their kind. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Experimental study of limit lean methane/air flame in a standard flammability tube using particle image velocimetry method

Lean limit methane/air flame propagating upward in a standard 50 mm diameter and 1.8 m length tube was studied experimentally using particle image velocimetry method. Local stretch rate along the flame front was determined by measured gas velocity distributions. It was found that local stretch rate is maximum at the flame leading point, which is in agreement with earlier theoretical results. Similar to earlier observations, extinction of upward propagating limit flame was observed to start from the flame top. It is stated that the observed behavior of the extinction of the lean limit methane/air flame can not be explained in terms of the coupled effect of flame stretch and preferential diffusion. To qualitatively explain the observed extinction behavior, it is suggested that the positive strain-induced flame stretch increases local radiation heat losses from the flame front. An experimental methodology for PIV measurements in a round tube is described. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements and interpretation of shock tube ignition delay times in highly CO 2 diluted mixtures using multiple diagnostics

Common definitions for ignition delay time are often hard to determine due to the issue of bifurcation and other non-idealities that result from high levels of CO 2 addition. Using high-speed camera imagery in comparison with more standard methods (e.g., pressure, emission, and laser absorption spectroscopy) to measure the ignition delay time, the effect of bifurcation has been examined in this study. Experiments were performed at pressures between 0.6 and 1.2 atm for temperatures between 1650 and 2040 K. The equivalence ratio for all experiments was kept at a constant value of 1 with methane as the fuel. The CO 2 mole fraction was varied between a value of X CO2 = 0.00 to 0.895. The ignition delay time was determined from three different measurements at the sidewall: broadband chemiluminescent emission captured via a photodetector, CH 4 concentrations determined using a distributed feedback interband cascade laser centered at 3403.4 nm, and pressure recorded via a dynamic Kistler type transducer. All methods for the ignition delay time were compared to high-speed camera images taken of the axial cross-section during combustion. Methane time-histories and the methane decay times were also measured using the laser. It was determined that the flame could be correlated to the ignition delay time measured at the side wall but that the flame as captured by the camera was not homogeneous as assumed in typical shock tube experiments. The bifurcation of the shock wave resulted in smaller flames with large boundary layers and that the flame could be as small as 30% of the cross-sectional area of the shock tube at the highest levels of CO 2 dilution. Here, comparisons between the camera images and the different ignition delay time methods show that care must be taken in interpreting traditional ignition delay data for experiments with large bifurcation effects as different methods in measuring the ignition delay time could result in different interpretations of kinetic mechanisms and impede the development of future mechanisms.

03 NATURAL GAS↗

Temporally and spatially resolved X-ray densitometry in a shock tube

Gas densities were measured by x-ray absorption spectroscopy to examine spatial inhomogeneity in density behind incident and reflected shock waves in a miniature (12.7 mm bore) high repetition rate shock tube. Shock waves were generated in argon. The pressure and temperature behind the incident shock were P 2 ~ 1.72 bar and T 2 ~ 800 K, while those behind the reflected shock were P 5 ~ 6.5 bar and T 5 ~ 1480 K. Time-resolved line-of-sight transmission measurements using x-rays at 9 keV photon energy were made along various axial and transverse locations covering the entire shock tube cross section. The x-ray transmission at each location was converted to pathlength-integrated densities, which in some conditions could be further converted to pathlength-averaged densities. The measured gas densities were compared with those calculated by the normal shock wave relations, and good agreement was found in the preshock and immediately behind the incident shock regions. Similar agreement was found for reflected shock conditions very near the endwall. However, increasingly large differences between the measured and calculated gas densities were found as distance from the endwall increased. Furthermore, reconstruction by Abel inversion allowed time and radially resolved densities to be obtained from the transverse measurements. While the profiles measured in this experiment are of insufficient signal-to noise level and resolution to definitively assign boundary layer thicknesses, future improvements may be able to do this. The radially resolved densities reveal growing sidewall thermal boundary layers in gases behind the reflected shock. These reconstructions were compared with a model of the thermal boundary layer and are consistent with values of the thermal boundary layer thickness being between 0.25 mm and 1 mm at 0.7 ms after shock reflection.

42 ENGINEERING↗

Convective heat transfer in the laminar-turbulent transition region with molten salt in a circular tube

In order to understand the heat transfer characteristics of molten salt and testify the validity of the well-known empirical convective heat transfer correlations, experimental study on transition convective heat transfer with molten salt in a circular tube was conducted. Molten salt circulations were realized and operated in a specially designed system over 1000 h. The average forced convective heat transfer coefficients of molten salt were determined by least-squares method based on the measured data of flow rates and temperatures. Finally, a heat transfer correlation of transition flow with molten salt in a circular tube was obtained and good agreement was observed between the experimental data of molten salt and the well-known correlations presented by Hausen and Gnielinski, respectively. (author)

36 MATERIALS SCIENCE↗

Experimental study of mixed convection heat transfer in vertical helically coiled tube heat exchangers

In this study the mixed convection heat transfer in a coil-in-shell heat exchanger for various Reynolds numbers, various tube-to-coil diameter ratios and different dimensionless coil pitch was experimentally investigated. The experiments were conducted for both laminar and turbulent flow inside coil. Effects of coil pitch and tube diameters on shell-side heat transfer coefficient of the heat exchanger were studied. Different characteristic lengths were used in various Nusselt number calculations to determine which length best fits the data and several equations were proposed. The particular difference in this study in comparison with the other similar studies was the boundary conditions for the helical coils. The results indicate that the equivalent diameter of shell is the best characteristic length. (author)

14 SOLAR ENERGY↗

Experimental investigation of convection heat transfer of CO{sub 2} at supercritical pressures in a vertical circular tube

The convection heat transfer characteristics of supercritical CO{sub 2} in a vertical circular tube of 2 mm inner diameter were investigated experimentally for pressures ranging from 78 to 95 bar, inlet temperatures from 25 to 40 C, and inlet Reynolds numbers from 3800 to 20,000. The effects of the heat flux, thermo-physical properties, buoyancy and thermal acceleration on the convection heat transfer were analyzed. The experimental results show that for high inlet Reynolds numbers (e.g. Re = 9000) and high heat fluxes, a significant local deterioration and recovery of the heat transfer was found for upward flows but not for downward flows. Comparison of the experimental data for inlet Reynolds numbers from 3800 to 20,000 with some well-known empirical correlations showed large differences especially when the heat transfer deteriorates and then recovers when the effect of buoyancy is significant. The experimental data was used to develop modified local turbulent Nusselt number correlations for supercritical CO{sub 2} flowing in vertical small circular tubes. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical simulation of flow boiling for organic fluid with high saturation temperature in vertical porous coated tube

A semi-analytical model is developed for the prediction of flow boiling heat transfer inside vertical porous coated tubes. The model assumes that the forced convection and nucleate boiling coexist together in the annular flow regime. We used conservations of mass, momentum, and energy to solve for the liquid film thickness and temperature. The heat flux due to nucleate boiling consists of those inside and outside micro-tunnels. To close the equations, a detailed analysis of various forces acting on the bubble is presented to predict its mean departure diameter. Furthermore, the active nucleation site density of porous layer is determined from the pool boiling correlation by introducing suppression factor. The flow boiling heat transfer coefficients of organic fluid (cumene) with high saturation temperature in a vertical flame-spraying porous coated tube are studied numerically. It is shown that the present model can predict most of the experimental values within ±20%. The numerical results also indicate that the nucleate boiling contribution to the overall heat transfer coefficient decreases from 50% to 15% with vapor quality increasing from 0.1 to 0.5.

42 ENGINEERING↗

Two-tier tube-trailer pressure consolidation operation method for hydrogen refueling station cost reduction

An operation strategy known as two-tier “pressure consolidation” of delivered tube-trailers (or equivalent supply storage) has been developed to maximize the throughput at gaseous hydrogen refueling stations (HRSs) for fuel cell electric vehicles (FCEVs). The high capital costs of HRSs and the consequent high investment risk are deterring growth of the infrastructure needed to promote the deployment of FCEVs. Stations supplied by gaseous hydrogen will be necessary for FCEV deployment in both the near and long term. Here, the two-tier pressure consolidation method enhances gaseous HRSs in the following ways: (1) reduces the capital cost compared with conventional stations, as well as those operating according to the original pressure consolidation approach described by Elgowainy et al. (2014) [1], (2) minimizes pressure cycling of HRS supply storage relative to the original pressure consolidation approach; and (3) increases use of the station’s supply storage (or delivered tube-trailers) while maintaining higher state-of-charge vehicle fills.

08 HYDROGEN↗

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

JAEA Fatigue Analysis of EBR-II Duplex Tubing

Small, notched three-point bend specimens machined from duplex tubes, which were extracted from an EBR-II superheater, were fatigued through the nickel interlayer to determine propensity for crack arrest within this interlayer. Several of these specimens were fatigued in the near threshold, and steady state regimes of Paris Law behavior. Additionally, two specimens were fatigued to the edge of the nickel interlayer and then monotonically loaded. Micro-hardness profiles of the nickel interlayer were also measured. Fatigue behavior was found to be similar to previous studies in that arrest was only noted in the near threshold Paris regime (attributed to the presence of voids) and in the steady state regime exhibited an acceleration of crack growth rate through the nickel interlayer followed by a slight retardation. Monotonic loading resulted in crack branching or delamination along the interlayer. Although archival material was not available for this study, the hardness of the nickel interlayer was determined to have been lowered slightly during service by comparison to the expected hardness of a similar nickel braze prepared as specified for fabrication of these tubes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Crystallographic texture gradient along the wall thickness of an SF-copper tube

Metallic tubes usually show heterogeneities along circumference and through wall thickness. Local texture analysis by synchrotron diffraction and global texture analysis by neutron diffraction was used describing texture variations related to the wall thickness. Test sample was an SF-Cu tube with outer diameter of 140 mm and an average wall thickness of 10 mm. The texture is dominated by the cube component {001} <100>. Other minor components are rotated cube {013} <100>, Goss {011} <100>, Cu {112} <111>, brass {110} <112>, S {123} <634>. The texture gradient over the wall thickness shows a remarkable variation of the sharpness of the cube component. Other components show only little variation. Comparing samples obtained at maximum wall thickness and at minimum wall thickness one can see that the wall thickness has an influence on the global texture as well as texture gradient. Another interesting result is, that global textures measured directly by neutrons and averaged global textures, calculated from the set of local measurements by synchrotron diffraction, agree surprisingly well despite their different resolution.

36 MATERIALS SCIENCE↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions

New comparative tests on two different types of solar collectors are presented in this paper. A standard glazed flat plate collector and an evacuated tube collector are installed in parallel and tested at the same working conditions; the evacuated collector is a direct flow through type with external compound parabolic concentrator (CPC) reflectors. Efficiency in steady-state and quasi-dynamic conditions is measured following the standard and it is compared with the input/output curves measured for the whole day. The first purpose of the present work is the comparison of results in steady-state and quasi-dynamic test methods both for flat plate and evacuated tube collectors. Besides this, the objective is to characterize and to compare the daily energy performance of these two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is plotted against the daily incident solar radiation. Test runs have been performed in several conditions to reproduce different conventional uses (hot water, space heating, solar cooling). Results are also presented in terms of daily efficiency versus daily average reduced temperature difference: this allows to represent the comparative characteristics of the two collectors when operating under variable conditions, especially with wide range of incidence angles. (author)

14 SOLAR ENERGY↗

Energy-efficient modification of reduction-melting for lead recovery from cathode ray tube funnel glass

Highlights: • We recovered Pb from cathode ray tube funnel glass using reduction melting process. • We modified the melting process to achieve Pb recovery with low energy consumption. • Pb in the funnel glass is efficiently recovered at 1000 °C by adding Na{sub 2}CO{sub 3}. • Pb remaining in the glass after reduction melting is extracted with 1 M HCl. • 98% of Pb in the funnel glass was recovered by reduction melting and HCl leaching. - Abstract: Lead can be recovered from funnel glass of waste cathode ray tubes via reduction melting. While low-temperature melting is necessary for reduced energy consumption, previously proposed methods required high melting temperatures (1400 °C) for the reduction melting. In this study, the reduction melting of the funnel glass was performed at 900–1000 °C using a lab-scale reactor with varying concentrations of Na{sub 2}CO{sub 3} at different melting temperatures and melting times. The optimum Na{sub 2}CO{sub 3} dosage and melting temperature for efficient lead recovery was 0.5 g per 1 g of the funnel glass and 1000 °C respectively. By the reduction melting with the mentioned conditions, 92% of the lead in the funnel glass was recovered in 60 min. However, further lead recovery was difficult because the rate of the lead recovery decreased as with the recovery of increasing quantity of the lead from the glass. Thus, the lead remaining in the glass after the reduction melting was extracted with 1 M HCl, and the lead recovery improved to 98%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗