Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Cryostat for Ultra-low-energy Threshold Germanium Spectrometers

This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the detection of low-energy nuclear recoils, an event class relevant to both dark matter direct detection and measurement of coherent neutrino-nucleus scattering. The cryostat design, including a thermal and electrical-field model, is presented. A prototype cryostat has been assembled and data acquired to evaluate its vacuum and thermal performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Low-Noise Germanium Ionization Spectrometer for Low-Background Science

Recent progress on the development of very low energy threshold high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended for use in a low mass, WIMP dark matter direct detection search. The integrated detector and low background cryostat achieved noise performance of 98 eV full-width half-maximum of an input electronic pulse generator peak and gamma-ray energy resolution of 1.9 keV full-width half-maximum at the 60Co gamma-ray energy of 1332 keV. This Transaction reports the thermal characterization of the low-background cryostat, specifications of the newly prepared 1.2 kg p-type point contact germanium detector, and the ionization spectroscopy – energy resolution and energy threshold – performance of the integrated system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION↗

In-flight verification of the calibration and performance of the ASTRO-H (Hitomi) Soft X-ray Spectrometer

The Soft X-ray Spectrometer onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3- to 12-keV band. Extensive preflight calibration measurements are the basis for our modeling of the pulse height–energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse height–energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsar wind nebulae to validate our models of the telescope area and detector efficiency and to derive a more accurate value for the thickness of the gate-valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab nebula to refine the pixel-to-pixel timing and validate the absolute timing.

79 ASTRONOMY AND ASTROPHYSICS↗

Localization and Quantification of Trace-gas Fugitive Emissions Using a Portable Optical Spectrometer

We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν3 R(4) CH4 transition at 6057.1 cm-1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv∙Hz-1/2, corresponding to a noise-equivalent absorption (NEA) of 4.4×10-6 Hz-1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10-7 cm-1∙Hz-1/2. Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) for initial demonstration of single-sensor based source localization and quantification of CH4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-of-arrival (AOA) results will be shown, and development towards source magnitude estimation will be described.

03 NATURAL GAS↗

Sci—Fri PM: Dosimetry—02: A Nested Neutron Spectrometer to Measure Neutron Spectra in Radiotherapy

During high-energy radiotherapy treatments, neutrons are produced in the head of the linac through photonuclear interactions. This has been a concern for many years as photoneutrons contribute to the accepted, yet unwanted, out-of-field doses that pose an iatrogenic risk to patients and an occupational risk to personnel. Presently, in-room neutron measurements are difficult and time-consuming and have traditionally been carried out using Bonner spheres with activation foils and TLDs. In this work, a new detector, the Nested Neutron Spectrometer (NNS) is tested for use in radiotherapy bunkers. The NNS is designed for easy handling and is more practical than the traditional Bonner spheres. The NNS, operated in current mode, was used to measure the dose equivalent, average energy and energy spectrum at several positions in a radiotherapy bunker. The average energy and spectra were compared to Monte Carlo simulations while the dose equivalent was compared to bubble detector measurements. The average energies, as measured by the NNS and Monte Carlo simulations, differed by approximately 30% across the bunker. Measurements of the dose equivalent using the NNS and the bubble detectors agreed within 50% in the maze and less than 10% close to the linac head. Apart from some discrepancies at thermal energies, we also found reasonable agreement between NNS-measured and Monte Carlo-simulated spectra at a number of locations within our radiotherapy bunker. Our results demonstrate that the NNS is a suitable detector to be used in high dose-rate radiotherapy environments.

07 ISOTOPE AND RADIATION SOURCES↗

Kinematics reconstruction in solenoidal spectrometers operated in active target mode

Here, we discuss the reconstruction of low-energy nuclear reaction kinematics from charged-particle tracks in solenoidal spectrometers working in Active Target Time Projection Chamber mode. In this operation mode, reaction products are tracked within the active gas medium of the Active Target with a three dimensional space point cloud. We have inferred the reaction kinematics from the point cloud using an algorithm based on a linear quadratic estimator (Kalman filter). The performance of this algorithm has been evaluated using experimental data from nuclear reactions measured with the Active Target Time Projection Chamber (AT-TPC) detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of $$\pi ^\pm $$ π ± , K $$^\pm $$ ± , p and $${\bar{\text {p}}}$$ p ¯ spectra in proton-proton interactions at 20, 31, 40, 80 and 158 $$\text{ GeV }/c$$ GeV / c with the NA61/SHINE spectrometer at the CERN SPS: The NA61/SHINE Collaboration

Measurements of inclusive spectra and mean multiplicities of $\pi^\pm$, K$^\pm$, p and $\bar{\textrm{p}}$ produced in inelastic p+p interactions at incident projectile momenta of 20, 31, 40, 80 and 158 GeV/c ($\sqrt{s} = $ 6.3, 7.7, 8.8, 12.3 and 17.3 GeV, respectively) were performed at the CERN Super Proton Synchrotron using the large acceptance NA61/SHINE hadron spectrometer. Spectra are presented as function of rapidity and transverse momentum and are compared to predictions of current models. The measurements serve as the baseline in the NA61/SHINE study of the properties of the onset of deconfinement and search for the critical point of strongly interacting matter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of $\pi ^\pm $, $K^\pm $ and proton double differential yields from the surface of the T2K replica target for incoming 31 GeV/c protons with the NA61/SHINE spectrometer at the CERN SPS: NA61/SHINE Collaboration

Measurements of the $\pi^{\pm}$, $K^{\pm}$, and proton double differential yields emitted from the surface of the 90-cm-long carbon target (T2K replica) were performed for the incoming 31 GeV/c protons with the NA61/SHINE spectrometer at the CERN SPS using data collected during 2010 run. The double differential $\pi^{\pm}$ yields were measured with increased precision compared to the previously published NA61/SHINE results, while the $K^{\pm}$ and proton yields were obtained for the first time. A strategy for dealing with the dependence of the results on the incoming proton beam profile is proposed. Furthermore, the purpose of these measurements is to reduce significantly the (anti)neutrino flux uncertainty in the T2K long-baseline neutrino experiment by constraining the production of (anti)neutrino ancestors coming from the T2K target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A search for new physics in central exclusive production using the missing mass technique with the CMS detector and the CMS-TOTEM precision proton spectrometer

A generic search is presented for the associated production of a Z boson or a photon with an additional unspecified massive particle X, pp → pp + Z/γ + X, in proton-tagged events from proton–proton collisions at $\sqrt{s}$ = 13 TeV, recorded in 2017 with the CMS detector and the CMS-TOTEM precision proton spectrometer. The missing mass spectrum is analysed in the 600–1600 GeV range and a fit is performed to search for possible deviations from the background expectation. No significant excess in data with respect to the background predictions has been observed. Model-independent upper limits on the visible pro duction cross section of pp → pp + Z/γ + X are set

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time Radiative Divertor Feedback Control Development for the NSTX-U Tokamak using a Vacuum Ultraviolet Spectrometer

A radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature Te estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPherson Model 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the delta n=0;1 line intensity ratios of carbon, nitrogen or neon ions lines in the spectral range 300 to 1600 A. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time Te-dependent signal within a characteristic divertor detachment equilibration time of ~ 10 -15 ms is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lock In Spectrometer v0.1

A method that uses a spectrometer to run a lock in amplifier process on multiple frequencies simultaneously.

Slaughter, Daniel↗

A Methodology for Estimating the Energy and Moisture Budget of the Convective Boundary Layer Using Continuous Ground-Based Infrared Spectrometer Observations

Abstract Land–atmosphere interactions play a critical role in both the atmospheric water and energy cycles. Changes in soil moisture and vegetation alter the partitioning of surface water and energy fluxes, influencing diurnal evolution of the planetary boundary layer (PBL). The mixing-diagram framework has proven useful in understanding the evolution of the heat and moisture budget within the convective boundary layer (CBL). We demonstrate that observations from the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains site provide all of the needed inputs needed for the mixing-diagram framework, allowing us to quantify the impact from the surface fluxes, advection, radiative heating, encroachment, and entrainment on the evolution of the CBL. Profiles of temperature and humidity retrieved from the ground-based infrared spectrometer [Atmospheric Emitted Radiance Interferometer (AERI)] are a critical component in this analysis. Large-eddy simulation results demonstrate that mean mixed-layer values derived are shown to be critical to close the energy and moisture budgets. A novel approach demonstrated here is the use of network of AERIs and Doppler lidars to quantify the advective fluxes of heat and moisture. The framework enables the estimation of the entrainment fluxes as a residual, providing a way to observe the entrainment fluxes without using multiple lidar systems. The high temporal resolution of the AERI observations enables the morning, midday, and afternoon evolution of the CBL to be quantified. This work provides a new way to use observations in this framework to evaluate weather and climate models. Significance Statement The energy and moisture budget of the planetary boundary layer (PBL) is influenced by multiple sources, and accurately representing this evolution in numerical models is critical for weather forecasts and climate predictions. The mixing-diagram approach, driven by profiling observations as illustrated here, provides a powerful way to quantify the contributions from each of these sources. In particular, the energy and moisture mixed into the PBL from above the PBL can be determined accurately from ground-based remote sensors using this approach.

54 ENVIRONMENTAL SCIENCES↗