Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Spatiotemporal Pattern Recognition in the PMU Signals in the WECC system

Phasor measurement unit (PMU) data has been used by multiple power system applications, including state estimation, post event analysis, oscillation detection, model validation, and many others. Still, due to its big data nature and availability to general research institutions, comprehensive understanding of the spatiotemporal patterns and underlying mechanisms are incomplete. This study applies a set of signal processing and machine learning approaches aiming at deciphering the characteristic behaviors of multiple phasor measurement units (PMUs) attributes (e.g., voltage, frequency, rate of change of frequency, phase angle), including their auto-correlation, cross-dependence, similarities and discrepancies across units and temporal scales, and distributions of anomalies and their linkages to potential external factors such as weather events. Data analytics are applied to PMUs from the U.S. Western Electricity Coordinating Council (WECC) system. The PMU measurements, recorded events, outages, and weather extremes are all from real world datasets. The findings from the study and mechanistic understanding of the PMU dynamics help provide guidance on system control or preventing blackouts. The derived metrics can be directly used for adjusting or filtering simulated PMU data used for advanced algorithm development.

Hou, Zhangshuan↗

Spin-dependent dark matter scattering in quasi-two-dimensional magnets

We study the prospects of detecting dark matter coupled to the spin of the electron, such that it may scatter and excite magnons—collective excitations of electronic spins. We show that materials exhibiting long-range magnetic order where the spins are coupled only along a plane may act as directional dark matter detectors. These quasi-two-dimensional materials possess anisotropic dispersion relations and structure functions which induce a sidereal modulation in the excitation rate. We calculate the expected signal rate for some candidate (anti)ferromagnets, demonstrating a possible route to the direct detection of spin-dependent dark matter in the keV to MeV mass range.

Dark matter direct detection↗

Advancing Enhanced Raman Spectroscopy to Detect and Measure NOW Pheromones (CPRB 2022 proposal)

Insect sex pheromones are chemical compounds that insects release to attract their partners over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. These pheromone-based strategies can include monitoring, mating disruption, mass trapping, attract-and-kill and push-pull. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage by this pest. Just how mating disruption works is not fully established and likely varies across products and target species. For instance, the extent to which synthetic pheromones compete with natural pheromone is not well understood, or in the case of monitoring, how efficaciously the insect follows the diffusing plumes, especially across large blocks and at plot borders. Furthermore, there may be specific conditions under which poor or impeded diffusion of synthetic pheromone diminishes the disruption effect, which could result in some males effectively locating females for reproduction. At the same time, many commercially available synthetic lures are also available, and growers have been effectively using them to track population development – although the attractive range of these lures remains unclear. That is, while pheromone lures can attract many moths, the relationship between trap capture and local populations, much less crop damage, remains unclear. Regardless of the emission source (aerosol puffers, meso emitters, lures etc.), we currently lack the ability to fully understand how these synthetic pheromone compounds diffuse away from their point-source of emission – and subsequently how this might affect the efficacy of mating disruption and/or the accuracy of monitoring efforts. Raman spectroscopy (RS) may offer a means to detect synthetic pheromone because of its analytical properties and recent technological advancements. In combination with nanostructured probes, RS has a demonstrated capability to detect volatiles at extremely low concentrations. While other methods for detecting pheromones have proven to be successful, such analytical methods like mass spectrometry (MS) gas chromatography (GC) require sampling in the fields and are not real-time. Other methods such as EAG/ EAD are also invasive (use antennas) but are of course valuable. Opto-electronic, micro and nano sensors just recently enticed interest. We fall in this latter category, proposing the use of optical spectroscopy (Raman) in a fiber aided by nanostructures to provide a chemical fingerprint without transductions and in real-time (i.e. no sampling). To date, we have been able to generate Raman signatures for the main chemicals in synthetic pheromones (a first for science, to the best of our knowledge), observe their trends at different concentrations, and also provide a clear distinction of such signatures in mixed samples via Principal Component Analysis (PCA) – all of which strengthens our conclusions on the ability of RS to detect emissions in more realistic conditions. We also established processes to enhance the detection sensitivity via preconcentration with Solid Phase Micro Extraction (SPME) fibers and Surface Enhanced Raman Spectroscopy (SERS) to increase the overall optical signals. Furthermore, we explored limitations and requirements for detecting from dispensers, lures, or live moths, including Dept. of Energy and CA State regulatory approvals. Finally, we setup some of our first “orchard in a box” experiments to measure pheromone diffusion along with developing appropriate models.

42 ENGINEERING↗

Lightwave-electronic harmonic frequency mixing

Electronic frequency mixers are fundamental building blocks of electronic systems. Harmonic frequency mixing in particular enables broadband electromagnetic signal analysis across octaves of spectrum using a single local oscillator. However, conventional harmonic frequency mixers do not operate beyond hundreds of gigahertz to a few terahertz. If extended to the petahertz scale in a compact and scalable form, harmonic mixers would enable field-resolved optical signal analysis spanning octaves of spectra in a monolithic device without the need for frequency conversion using nonlinear crystals. Here, we demonstrate lightwave-electronic harmonic frequency mixing beyond 0.350 PHz using plasmonic nanoantennas. We demonstrate that the mixing process enables complete, field-resolved detection of spectral content far outside that of the local oscillator, greatly extending the range of detectable frequencies compared to conventional heterodyning techniques. Our work has important implications for applications where optical signals of interest exhibit coherent femtosecond-scale dynamics spanning multiple harmonics.

Science & Technology - Other Topics↗

Constraining ΛCDM cosmological parameters with Einstein Telescope mock data

ABSTRACT We investigate the capability of Einstein Telescope to constrain the cosmological parameters of the non-flat ΛCDM cosmological model. Two types of mock data sets are considered depending on whether or not a short gamma-ray burst is detected, and associated with the gravitational wave emitted by binary neutron stars merger, using the THESEUS satellite. Depending on the mock data set, two statistical estimators are applied: one assumes that the redshift is known, while the other marginalizes over it assuming a specific redshift prior distribution. We demonstrate that (i) using mock catalogues collecting gravitational wave signals emitted by binary neutron stars systems to which a short gamma-ray burst has been associated, Einstein Telescope may achieve an accuracy on the cosmological parameters of $\sigma _{H_0}\approx 0.40$ km s−1 Mpc−1, $\sigma _{\Omega _{k,0}}\approx 0.09$, and $\sigma _{\Omega _{\Lambda ,0}}\approx 0.07$; while (ii) using mock catalogues collecting all gravitational wave signals emitted by binary neutron stars systems for which an electromagnetic counterpart has not been detected, Einstein Telescope may achieve an accuracy on the cosmological parameters of $\sigma _{H_0}\approx 0.04$ km s−1 Mpc−1, $\sigma _{\Omega _{k,0}}\approx 0.01$, and $\sigma _{\Omega _{\Lambda ,0}}\approx 0.01$, once the redshift probability distribution of GW events is known from from population synthesis simulations and/or the measure of the tidal deformability parameter. These results show an improvement of a factor 2–75 with respect to earlier results using complementary data sets.

Califano, Matteo↗

Numerical Simulation of Infrasound Resonance in Underground Tunnel Structures

Remote observation of infrasound resonant signals emanating from underground tunnel structures could potentially allow the remote quantification of the geometry of the underground structures in which the signals were generated. However, the sensitivity of these observations to tunnel geometry and changes in that geometry are unknown. In this report we outline a numerical simulation study with the following three objectives: 1. Can we model infrasound resonance using numerical simulations? 2. What is the sensitivity of the modeled observations to changes in tunnel geometry or boundary conditions? And 3. Can we accurately model resonant observations of explosions occurring in Redmond Salt Mine in Central Utah. In this report we outline affirmative answers to the first two objectives, but we were unable to accurately model the Redmond Explosions due to numerical instability in the model of the complex structure of the mine. Recommendations for future work emphasize the need to acquire additional datasets and to explore a more data-based approach in which changes in data signatures are detected as a first step towards developing a method which inverts resonant infrasound signals for tunnel geometry.

47 OTHER INSTRUMENTATION↗

Novel Light Detectors for Directional MeV scale DM Detectors

The search for sub-GeV dark matter requires novel detector development due to the small expected ionization signal and large backgrounds, many of which still need to be well-modeled. For this reason, to unambiguously detect dark matter, a detector must be able to determine the directionality of the incoming particles so that the daily modulation of the rate can be used to confirm a dark matter signal. This can be accomplished by combining anisotropic scintillating crystals, such as trans-Stilbene, as a detector target, with an optically-sensitive Skipper CCD as a readout. I will present on my work over the past six months developing the first prototype of this detector, including optical testing of the trans-Stilbene and design of the detector. This work will lead to characterization of the CCDs and deployment of the first prototype later this year.

Hoch, Nora [MIT]↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Primordial non-Gaussianity from the effects of the Standard Model Higgs during reheating after inflation

We propose a new way of studying the Higgs potential at extremely high energies. The Standard Model (SM) Higgs boson, as a light spectator field during inflation in the early Universe, can acquire large field values from its quantum fluctuations which vary among different causal (Hubble) patches. Such a space dependence of the Higgs after the end of inflation leads to space-dependent SM particle masses and hence variable efficiency of reheating, when the inflaton decays to Higgsed SM particles. Inhomogeneous reheating results in (observable) temperature anisotropies. Further, the resulting temperature anisotropy spectrum acquires a significant non-Gaussian component, which is constrained by Planck observations of the Cosmic Microwave Background (CMB) and potentially detectable in next-generation experiments. Constraints on this non-Gaussian signal largely exclude the possibility of the observed temperature anisotropies arising primarily from Higgs effects. Hence, in principle, observational searches for non-Gaussianity in the CMB can be used to constrain the dynamics of the Higgs boson at very high (inflationary) energies.

79 ASTRONOMY AND ASTROPHYSICS↗

A Self-learning Neural Network Approach for Radio Frequency Interference Detection and Removal in Radio Astronomy

In this work, we present a novel neural network (NN) method for the detection and removal of radio frequency interference (RFI) from the raw digitized signal in the signal processing chain of a typical radio astronomy experiment. The main advantage of our method is that it does not require a training set. Instead, our method relies on the fact that the true signal of interest coming from astronomical sources is thermal and therefore described as a Gaussian random process, which cannot be compressed. We employ a variational encoder/decoder network to find the compressible information in the data stream that can explain the most variance with the fewest degrees of freedom. We demonstrate it on a set of toy problems and stored ring buffers from the Baryon Mapping eXperiment prototype. We find that the RFI subtraction is effective at cleaning simulated time streams: While we find that the power spectra of the RFI-cleaned time streams output by the NN suffer from extra signal consistent with additive noise, we find that it is generally around percent level across the band and sub 10% in contaminated spectral channels even when RFI power is an order of magnitude larger than the signal. We discuss the advantages and limitations of this method and possible implementation in the front end of future radio experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting axion dynamics on the surface of magnetic topological insulators

Axions, initially proposed to solve the strong CP problem, have recently gained attention in condensed matter physics, particularly in topological insulators. However, detecting axion dynamics has proven challenging, with no experimental confirmations to date. In this paper, we identify the surface of magnetic topological insulators as an ideal platform for observing axion dynamics. The vanishing bulk gap at the surface allows for order O(1) variations in the axion field, making the detection of axionlike phenomena more feasible. In contrast, these phenomena are strongly suppressed in the bulk due to the small magnetic exchange gap. We investigate two-photon decay as a signature of axion dynamics and calculate the branching ratio using a perturbative approach. Our findings reveal that the photon flux emitted from the surface is in plane and orders of magnitude larger than that from the bulk, making it detectable with modern microwave technology. We also discuss potential material platforms for detecting axion two-photon decay and strategies to enhance the signal-to-noise ratio.

Gao, Zhi-Qiang↗

Real-Time GPU-Accelerated OFDR With an Integrated Auxiliary Interferometer

A GPU-accelerated optical frequency domain reflectometry (OFDR) system with an improved integrated auxiliary interferometer is proposed. Unlike conventional approaches that require separate auxiliary interferometers and multiple detection channels, the proposed OFDR system embeds this functionality directly into the signal via an intentional beat component. This enables self-calibration of laser nonlinearity while maintaining a cost-effective hardware configuration. Building on this simplified configuration, the system leverages GPU acceleration with an NVIDIA RTX 4070 Ti to achieve real-time performance, delivering high-throughput signal processing for continuous OFDR interrogation. The signal processing pipeline comprises signal capture, resampling for nonlinearity compensation, and frequency shift computation, all optimized for parallel execution. Hardware benchmarking demonstrates substantial acceleration over CPU implementations, achieving up to a 45× speedup for resampling and frequency shift computations and enabling processing latencies below 30 ms. Thermal response validation is conducted under two complementary scenarios: localized heating using a water bath and cryogenic-temperature conditions using liquid nitrogen. Under localized heating, the system achieves an accuracy of 0.249 °C with a thermal sensitivity of 5.971 GHz/°C, while cryogenic-temperature validation demonstrates a frequency shift response with a sensitivity of 2.383 GHz/°C and an accuracy of 2.04 °C. The high acceleration of the proposed GPU-accelerated OFDR system and its accuracy are achieved by exploiting CUDA-based stride indexing, enabling efficient parallel segmentation and processing of large datasets without additional memory copies. The benchmarking results confirm the robustness, accuracy, and deployability of the proposed OFDR system across a wide temperature range, establishing it as a practical platform for real-time distributed fiber sensing in structurally dynamic environments.

Harb, Salah [Lawrence Berkeley National Laboratory↗

Identifying Outliers in AI-based Image Compression

Image compression using artificial intelligence (AI) is becoming increasingly prevalent across various fields, including scientific research. Scientific instruments can generate hundreds of images per second, and effectively compressing these images with high compression ratios is crucial for facilitating scientific discoveries. However, automatically detecting outlier cases, where compression may not have succeeded or where interesting scientific phenomena are present, poses a significant challenge. To address this, we have developed a methodology based on unsupervised machine learning techniques for detecting outlier compressed images. This methodology utilizes metrics such as peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), structural texture similarity index measure (STSIM), and deep image and structural texture similarity index (DISTS). We have evaluated our methodology on several unlabeled datasets, including microscopy and x-ray images, and have successfully identified multiple outlier images using our proposed approach. Furthermore, our approach has enabled us to identify image semantics that are valuable for post-experiment analysis by scientists.

Data Analysis↗

Equalization of Intensity-Modulated Fiber-Optic Voltage Sensors for Power Distribution Systems

We test fiber-optic voltage sensors based on optical reflection from a piezoelectric transducer. Our specific devices possess a 2 kHz fundamental resonance, and we verify a readily usable frequency band from approximately 10 Hz to 3 kHz, with a dynamic range of 60 dB for a detection system integrating over this entire band. Additionally, we demonstrate a digital signal processing approach to equalize the measured frequency response, enabling accurate retrieval of short-pulse inputs. These results suggest the value and applicability of intensity-modulated fiber-optic voltage sensors for measuring both steady-state waveforms and broadband transients which, coupled with the straightforward and compact design of the sensors, should make them effective tools in electric grid monitoring.

42 ENGINEERING↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmonics-enhanced photoconductive terahertz detector pumped by Ytterbium-doped fiber laser

We present a photoconductive terahertz detector operating at the 1 µm wavelength range at which high-power and compact Ytterbium-doped femtosecond fiber lasers are available. The detector utilizes an array of plasmonic nanoantennas to provide sub-picosecond transit time for the majority of photo-generated carriers to enable high-sensitivity terahertz detection without using a short-carrier-lifetime substrate. By using a high-mobility semiconductor substrate and preventing photocarrier recombination, the presented detector offers significantly higher sensitivity levels compared with previously demonstrated broadband photoconductive terahertz detectors operating at the 1 µm wavelength range. We demonstrate pulsed terahertz detection over a 4 THz bandwidth with a record-high signal-to-noise ratio of 95 dB at an average terahertz radiation power of 6.8 µW, when using an optical pump power of 30 mW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Initial dynamic photoactive materials testing of an atmospheric chamber intended for radioactive and hazardous gases

Radioisotopes and hazardous gases can have undetermined environmental pathways. Researchers at Pacific Northwest National Laboratory constructed a chamber that complies with the requirements needed for an atmospheric reaction platform and the safety principles of interacting with hazardous dispersible sources to enable the environmental testing of these gases. Initial dynamic testing showed inter-chamber mixing completed from minutes to 1.5 hours. The photooxidation of butyl iodine showed the presence of signals from reaction products, and intermediaries for up to 50 hours. Current detection limits of the chamber and analytical collection and testing approach were shown to be in the single-digit parts per billion levels. In conclusion, the comparisons between the measured oxidation trends and literature show the utility of performing laboratory experiments to validate the results of modeling for larger-scale scenarios.

54 ENVIRONMENTAL SCIENCES↗