Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Simultaneous X-ray fluorescence and scanning X-ray diffraction microscopy at the Australian Synchrotron XFM beamline

Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed raster-scanning synchrotron serial microcrystallography with a high-precision piezo-scanner

The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1 µm beam size and photon flux of 3 × 10 12 photons s −1 at a photon energy of 12.66 keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the full flux of the FMX beamline, a high-speed, high-precision goniometer based on a unique XYZ piezo positioner has been designed and constructed. The piezo-based goniometer is able to achieve sub-100 nm raster-scanning precision at over 10 grid-linepairs s −1 frequency for fly scans of a 200 µm-wide raster. The performance of the scanner in both laboratory and serial crystallography measurements up to the maximum frame rate of 750 Hz of the Eiger 16M's 4M region-of-interest mode has been verified in this work. This unprecedented experimental speed significantly reduces serial-crystallography data collection time at synchrotrons, allowing utilization of the full brightness of the emerging synchrotron radiation facilities.

43 PARTICLE ACCELERATORS↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Scanning Methods for Ship-to-Rail Intermodal Cargo Containers

The Department of Homeland Security’s (DHS) Domestic Nuclear Detection Office (DNDO) runs the Rail Test Center (RTC) at the Port of Tacoma (POT). The RTC affords DNDO with the opportunity to test radiological and nuclear threat detection systems associated with the unique on-dock rail environment while in an operational seaport. DNDO selected the Pacific Northwest National Laboratory (PNNL) to manage the RTC. The RTC is conducting various evaluation studies to assess scanning opportunities in terms of their affects on the num-ber of container moves required and the affect that the scanning opportunity has on the time it takes to move a container through the on-dock transfer process from ship to rail. The velocity and the number of container moves are directly associated with incremental costs to the terminal operators; increases in either of these parameters help in-form the potential for incremental costs that would result from the implementation of the opportunity.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Molecular beam epitaxial growth and scanning tunneling microscopy studies of the gallium rich trench line structure on N-polar w-GaN( 000 1 ¯ )

In addition to the usual set of the well-known reconstructions that have been observed on the N-polar GaN surface, namely 1×1, 3×3, 6×6, and c(6×12), an additional structure is occasionally seen at high Ga coverage, which can extend over a large area of the surface. This structure, which is referred to as trench line structure, is partially ordered and consists of parallel-running dark (trench) lines separating wide and narrow strips of atomically ordered regions. There are also randomly placed defects interrupting the ideal ordering. Reflection high energy electron diffraction and scanning tunneling microscopy in ultrahigh vacuum are applied to investigate this trench line structure on samples prepared using molecular beam epitaxy. It is found that the trench line structure results from annealing the Ga-rich c(6×12) at high temperature followed by quenching to room temperature. By careful comparison of the scanning tunneling microscopy images with those from neighboring c(6×12) regions, it is found that the trench line structure can be decomposed into subunits of the c(6×12). Using these subunits, some simple models for the trench line structure are created. It is proposed that the trench line structure is composed of two primary c(6×12) subunits consisting of first and second layer Ga adatoms and that the trench lines are regions devoid of Ga adatoms, going down to the Ga adlayer.

36 MATERIALS SCIENCE↗

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials↗

Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters

The dose response of the BANG 3 polymer gel dosimeter (MGS Research Inc., Madison, CT) was studied using the OCTOPUS laser CT scanner (MGS Research Inc., Madison, CT). Six 17 cm diameter and 12 cm high Barex cylinders, and 18 small glass vials were used to house the gel. The gel phantoms were irradiated with 6 and 10 MV photons, as well as 12 and 16 MeV electrons using a Varian Clinac 2100EX. Three calibration methods were used to obtain the dose response curves: (a) Optical density measurements on the 18 glass vials irradiated with graded doses from 0 to 4 Gy using 6 or 10 MV large field irradiations; (b) optical-CT scanning of Barex cylinders irradiated with graded doses (0.5, 1, 1.5, and 2 Gy) from four adjacent 4x4 cm{sup 2} photon fields or 6x6 cm{sup 2} electron fields; and (c) percent depth dose (PDD) comparison of optical-CT scans with ion chamber measurements for 6x6 cm{sup 2}, 12 and 16 MeV electron fields. The dose response of the BANG 3 gel was found to be linear and energy independent within the uncertainties of the experimental methods (about 3%). The slopes of the linearly fitted dose response curves (dose sensitivities) from the four field irradiations (0.0752{+-}3%, 0.0756{+-}3%, 0.0767{+-}3%, and 0.0759{+-}3% cm{sup -1} Gy{sup -1}) and the PDD matching methods (0.0768{+-}3% and 0.0761{+-}3% cm{sup -1} Gy{sup -1}) agree within 2.2%, indicating a good reproducibility of the gel dose response within phantoms of the same geometry. The dose sensitivities from the glass vial approach are different from those of the cylindrical Barex phantoms by more than 30%, owing probably to the difference in temperature inside the two types of phantoms during gel formation and irradiation, and possible oxygen contamination of the glass vial walls. The dose response curve obtained from the PDD matching approach with 16 MeV electron field was used to calibrate the gel phantom irradiated with the 12 MeV, 6x6 cm{sup 2} electron field. Three-dimensional dose distributions from the gel measurement and the Eclipse planning system (Varian Corporation, Palo Alto, CA) were compared and evaluated using 3% dose difference and 2 mm distance-to-agreement criteria.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-267: Proton Pencil Beam Scanning for Mediastinal Lymphoma: 4-Dimensional Feasibility Study

Purpose: To assess the feasibility of proton pencil beam scanning (PBS) for the treatment of mediastinal lymphoma. Methods: A group of 6 patients were planned using an anterior field with PBS. Spots with ∼5 mm σ were used for all patients, while large spots (∼10 mm σ) were employed for patients with motion perpendicular to the beam (≥5 mm). We considered volumetric repainting such that, in each fraction, the same field would be delivered twice. Four-dimensional dose was calculated on initial and verification 4-dimensional computed tomography (4D-CT) scans (2—3) based on respiratory trace and beam delivery sequence. This was implemented by binning the spots into separate plans on each 4D-CT phase respectively. Four starting phases were sampled for each painting and 4 energy switching times (0.5 s, 1 s, 3 s, and 5 s) were tested, resulting in 2560 dose distributions for the cohort. Plan robustness was measured for target and critical structures in terms of the percentage difference between delivered dose and planned dose. Results: For 5 of the 6 patients, the ITV (internal target volume) D 98% was degraded by <3% (standard deviations ∼ 0.1%) when averaged over the whole course (up to 5% per fraction). Deviations of mean lung dose, heart maximum dose, and cord maximum dose were within 5% of prescribed dose. For one patient with motion perpendicular to the beam (up to 5 mm), the degradation of ITV D 98% was 9% over the whole course (12% per fraction), which was mitigated to 1% (3% per fraction) by employing large spots and repainting. No significant difference in coverage was observed for different energy switching times. Conclusion: This feasibility study demonstrates that, for mediastinal lymphoma, the PBS plan robustness can be maintained during delivery when target motion is measured and volumetric repainting and/or large spots are employed. This work was supported by Ion Beam Application.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-J-06: The Impact of CT-Scan Energy On Range Uncertainty in Proton Therapy Planning

Purpose: To investigate the impact of tube potential (kVp) on the CTnumber (HU) to proton stopping power ratio (PSPR) conversion table; the range uncertainty and the dosimetric change introduced by a mismatch in kVp between the CT and the HU to PSPR table used to calculate dose are analyzed. Methods: A CIRS CT-ED phantom was scanned with a Philips Brilliance 64-slice scanner under 90kVp and 120kVp tube potentials. Two HU to PSPR curves were then created. Using Eclipse (Varian) a treatment plan was created for a single beam in a water phantom (HU=0) passing through a wedge-shaped heterogeneity (HU=1488). The dose was recalculated by changing only the HU to PSPR table used in the dose calculation. The change in range (the distal 90% isodose line) relative to a distal structure was recorded as a function of heterogeneity thickness in the beam. To show the dosimetric impact of a mismatch in kVp between the CT and the HU to PSPR table, we repeated this procedure using a clinical plan comparing DVH data. Results: The HU to PSPR tables diverge for low-density bone and higher density structures. In the phantom plan, the divergence of the tables results in a change in range of ~1mm per cm of bone in the beam path for the HU used. For the clinical plan, a mismatch in kVp showed a 28% increase in mean dose to the brainstem along with a 10% increase in maximum dose to the brainstem center. Conclusion: A mismatch in kVp between the CT and the HU to PSPR table can introduce significant uncertainty in the proton beam range. For dense bone, the measured range uncertainty is about 1mm per cm of bone in the beam. CT-scan energy verification should be employed, particularly when high-density media is in the proton beam path.

60 APPLIED LIFE SCIENCES↗

MO-C-18C-01: Radiation Risks at Level of Few CT Scans: How Real?- Science to Practice

There are controversies surrounding radiation effects in human population in the range of radiation doses encountered by patients resulting from one to several CT scans. While it is understandable why the effects from low levels of diagnostic radiation are controversial, the situation is complicated by the media which may distort the known facts. There is need to understand the state of science regarding low-level radiation effects and also to understand how to communicate the potential risk with patients, the public and media. This session will seek to come to a consensus in order to speak with one voice to the media and the public. This session will review radiation effects known so far from a variety of exposed groups since the nuclear holocaust, provide clarification where effects are certain and where they are not, at what level extrapolation is the only way and at what level there is weak but agreeable acceptance. We will depict where and why there is agreement among organizations responsible for studying radiation effects, and how to deal with situations where effects are uncertain. Specific focus on radiation effects in children will be provided.Finally, the session will attempt to bridge the communication gap from the science to how to be an effective communicator with patients, parents, and media about ionizing radiation. Learning Objectives: To have a clear understanding about certainties and uncertainties of radiation effects at the level of a few CT scans To understand the results and limitations from 3 major pediatric CT scientific studies on childhood exposures published recently. To understand successful strategies used in risk communication.

60 APPLIED LIFE SCIENCES↗

TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

TH-C-BRD-09: Successes and Limitations of Online Range Adaptive Spot Scanning Proton Therapy for NSCLC

Purpose: To determine the ability to adapt discrete spot-scanning proton therapy (SSPT) plans based on geometric changes of anatomy to minimize normal tissue dose and maintain target coverage. Methods: We developed and tested a range-correction algorithm to compensate for anatomy changes in SSPT with correction factors for target lateral size changes and energy scaling. This algorithm adjusts the energy of each spot from the original optimized treatment plan to match the new daily anatomy based on water equivalent path-length. To correct for the lateral target size changes, the peripheral spots were scaled based on phantom studies with variable target size. For energy change corrections, alternative cumulative scaling factor lookup tables were generated based on calculated central-axis and integral depth dose calculations for different energies. These various adaptive algorithms were performed on 7 lung cancer patients that were previously treated with proton therapy and who required at least one adaptive intervention. Single-field optimized SSPT plans were generated for these patients with clinical beam angles. Dose-volume histogram metrics were obtained for these patients for both the non-adaptive and the different adaptive plans applied to the last available weekly CT scan. Results: The doses to normal tissue were largely reduced for the spinal cord (Dmax), total lung (V20Gy), and contralateral lung (V20Gy) for all different methods of adaptive planning. With both corrections applied, the average changes for these metrics were −6.2Gy, −2.7%, and −4.9%, respectively. The same method generated unacceptably high target hot spots with average target V110% increase of 12.3%. Conclusion: Adaptive methods based on direct adjustments to proton range can reduce normal tissue doses under large anatomical changes but are insufficient in achieving clinically acceptable target doses and generate unacceptably sizeable hot spots. Adaptive planning methods for proton therapy will likely necessitate some aspect of reoptimization for acceptable clinical utility.

60 APPLIED LIFE SCIENCES↗

Comparison between target margins derived from 4DCT scans and real-time tumor motion tracking: Insights from lung tumor patients treated with robotic radiosurgery

Purpose: A unique capability of the CyberKnife system is dynamic target tracking. However, not all patients are eligible for this approach. Rather, their tumors are tracked statically using the vertebral column for alignment. When using static tracking, the internal target volume (ITV) is delineated on the four-dimensional (4D) CT scan and an additional margin is added to account for setup uncertainty [planning target volume (PTV)]. Treatment margins are difficult to estimate due to unpredictable variations in tumor motion and respiratory pattern during the course of treatment. The inability to track the target and detect changes in respiratory characteristics might result in geographic misses and local tumor recurrences. The purpose of this study is to develop a method to evaluate the adequacy of ITV-to-PTV margins for patients treated in this manner. Methods: Data from 24 patients with lesions in the upper lobe (n = 12), middle lobe (n = 3), and lower lobe (n = 9) were included in this study. Each patient was treated with dynamic tracking and underwent 4DCT scanning at the time of simulation. Data including the 3D coordinates of the target over the course of treatment were extracted from the treatment log files and used to determine actual target motion in the superior–inferior (S–I), anterior–posterior (A–P), and left–right (L–R) directions. Different approaches were used to calculate anisotropic and isotropic margins, assuming that the tumor moves as a rigid body. Anisotropic margins were calculated by separating target motion in the three anatomical directions, and a uniform margin was calculated by shifting the gross tumor volume contours in the 3D space and by computing the percentage of overlap with the PTV. The analysis was validated by means of a theoretical formulation. Results: The three methods provided consistent results. A uniform margin of 4.5 mm around the ITV was necessary to assure 95% target coverage for 95% of the fractions included in the analysis. In the case of anisotropic margins, the expansion required in the S–I direction was larger (8.1 mm) than those in the L–R (4.9 mm) and A–P (4.5 mm) directions. This margin accounts for variations of target position within the same treatment fraction. Conclusions: The use of bony alignment for CyberKnife lung stereotactic body radiation therapy requires careful considerations, in terms of the potential for increased toxicity or local miss. Our method could be used by other centers to determine the adequacy of ITV-to-PTV margins for their patients.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP1-05: A Framework for the Analytic Calculation of Patient-Specific Dose Distribution Due to CBCT Scan for IGRT

Purpose: To investigate the feasibility of an analytic framework to estimate patients’ absorbed dose distribution owing to daily cone-beam CT scan for image-guided radiation treatment. Methods: To compute total absorbed dose distribution, we separated the framework into primary and scattered dose calculations. Using the source parameters such as voltage, current, and bowtie filtration, for the primary dose calculation, we simulated the forward projection from the source to each voxel of an imaging object including some inhomogeneous inserts. Then we calculated the primary absorbed dose at each voxel based on the absorption probability deduced from the HU values and Beer’s law. In sequence, all voxels constructing the phantom were regarded as secondary sources to radiate scattered photons for scattered dose calculation. Details of forward projection were identical to that of the previous step. The secondary source intensities were given by using scatter-to- primary ratios provided by NIST. In addition, we compared the analytically calculated dose distribution with their Monte Carlo simulation results. Results: The suggested framework for absorbed dose estimation successfully provided the primary and secondary dose distributions of the phantom. Moreover, our analytic dose calculations and Monte Carlo calculations were well agreed each other even near the inhomogeneous inserts. Conclusion: This work indicated that our framework can be an effective monitor to estimate a patient’s exposure owing to cone-beam CT scan for image-guided radiation treatment. Therefore, we expected that the patient’s over-exposure during IGRT might be prevented by our framework.

60 APPLIED LIFE SCIENCES↗

Scanning tunneling microscopy of the atomically smooth (001) surface of vanadium pentoxide V{sub 2}O{sub 5} crystals

The (001) cleavage surface of vanadium pentoxide (V{sub 2}O{sub 5}) crystal has been studied by scanning tunneling spectroscopy (STM). It is shown that the surface is not reconstructed; the STM image allows geometric lattice parameters to be determined with high accuracy. The nanostructure formed on the (001) cleavage surface of crystal consists of atomically smooth steps with a height multiple of unit-cell parameter c = 4.37 Å. The V{sub 2}O{sub 5} crystal cleavages can be used as references in calibration of a scanning tunneling microscope under atmospheric conditions both along the (Ñ…, y) surface and normally to the sample surface (along the z axis). It is found that the terrace surface is not perfectly atomically smooth; its roughness is estimated to be ~0.5 Å. This circumstance may introduce an additional error into the microscope calibration along the z coordinate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Perspectives on deterministic control of quantum point defects by scanned probes

Control over individual point defects in solid-state systems is becoming increasingly important, not only for current semiconductor industries but also for next generation quantum information science and technologies. To realize the potential of these defects for scalable and high-performance quantum applications, precise placement of defects and defect clusters at the nanoscale is required, along with improved control over the nanoscale local environment to minimize decoherence. These requirements are met using scanned probe microscopy in silicon and III-V semiconductors, which suggests the extension to hosts for quantum point defects such as diamond, silicon carbide, and hexagonal boron nitride is feasible. Here we provide a perspective on the principal challenges toward this end, and new opportunities afforded by the integration of scanned probes with optical and magnetic resonance techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Report – Study of Shortwave Spectra in Fully 3D Environment. Synergy Between Scanning Radars and Spectral Radiation Measurements

ARM set out 20 years ago to “close” the radiation problem, that is, to improve radiation models to the point where they could routinely predict the observed spectral radiation fluxes knowing the optical properties of the surface and of gases, clouds and aerosols in the atmosphere. Only then could such radiation models form a proper springboard for global climate model (GCM) parameterizations of spectral radiation. Sustained efforts have more or less achieved that goal with regard to longwave radiation; ASR models now routinely predict ARM spectral longwave radiances to 1–2%. Similar efforts in the shortwave have achieved far less; the successes are mainly for carefully selected 1D stratiform cloud cases. Such cases amount, even with the most optimistic interpretation, to no more than 30% of all cases at SGP. The problem has not been lack of effort but lack of appropriate instruments.The new ARM stimulus-funded instruments, with their new capabilities, will dramatically improve this situation and once again make progress possible on the shortwave problem. The new shortwave spectrometers will provide a reliable, calibrated record including the near infrared – and for other climatic regimes than SGP. The new scanning radars will provide the 3D cloud view, making it possible to tackle fully 3D situations. Thus, our main theme for the project is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars and shortwave spectrometers with the arsenal of radiative transfer tools.

54 ENVIRONMENTAL SCIENCES↗

U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

36 MATERIALS SCIENCE↗