Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “S-BAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Generation of High Peak Power Hard X-Rays at LCLS-II with Double Bunch Self-seeding

We propose to use existing LCLS copper S-band linac double bunch infrastructure to significantly improve LCLS-II hard X-ray performance. In our setup, we use the first bunch to generate a strong seeding X-ray signal, and the second bunch, initially traveling off-axis, to interact with the seed in the amplifier undulator and generate a near TW, 15 fs duration X-ray pulse in the 4 to 8 keV photon energy range. We investigate, via numerical simulations, the required transverse beam dynamics and the four crystals X-ray monochromator to be added to the existing LCLS-II beamline and discuss the final properties of the hard X-ray pulses and their potential application in high intensity, high-field physics experiments, including QED above the Schwinger critical field.

Halavanau, A.↗

Compact high gradient ion accelerating structure

A high gradient linear accelerating structure can propagate high frequency waves at a negative harmonic to accelerate low-energy ions. The linear accelerating structure can provide a gradient of 50 MV/m for particles at a β of between 0.3 and 0.4. The high gradient structure can be a part of a linear accelerator configured to provide an energy range from an ion source to 450 MeV/u for 12 C 6+ and 250 MeV for protons. The linear accelerator can include one or more of the following sections: a radiofrequency quadrupole (RFQ) accelerator operating at the sub-harmonic of the S-band frequency, a high gradient structure for the energy range from ˜45 MeV/u to ˜450 MeV/u.

Kutsaev, Sergey↗

High-Performance Accelerator Modeling: Toward Improving Controls and Diagnostics for High-Brightness Beams in Experiment

One of the main charges of beam physics is to improve the overall beam quality delivered to experiments and applications, which is generally quantified by the beam brightness. High brightness beams have numerous applications, including x-ray free electron lasers and ultrafast electron diffraction (UED). To these ends, this thesis details efforts to use high-performance models --- high-fidelity models that execute quickly --- for controls and diagnostics. To demonstrate the generality of these techniques, this thesis focuses on three of the most successful photoinjector designs currently used worldwide: the UCLA/SLAC/BNL-type high-gradient S-band gun, the continuous-wave high-repetition rate VHF APEX gun and the L-band DESY-PITZ-type gun. Work will be shown from Pegasus (UCLA), HiRES (LBNL) and FAST (FNAL).Specifically, data-driven models for online virtual diagnostics are presented, in this case, in the context of UED at HiRES, leading to a temporal resolution improvement. Methods for improving the fidelity of physics-based models are discussed, with examples at HiRES, Pegasus and FAST. Markov-chain Monte Carlo analysis is applied to match simulations, in the context of photocathode studies at HiRES and Pegasus. Lastly, the augmentation of online model-based predictions with model-independent optimization is explored in a fluctuating environment at Pegasus and HiRES. A central theme of this dissertation is working with parameter fluctuations when modeling an accelerator beamline. Long-term drifts and shot-to-shot jitter exist in every accelerator to a varying degree and therefore play an important role in every chapter of this dissertation. This thesis attempts to address the issues associated with these fluctuations when trying to develop faithful model representations of the system.

43 PARTICLE ACCELERATORS↗

Commissioning Results of the LCLS Injector

The Linac Coherent Light Source (LCLS) is a SASE xray Free-Electron Laser (FEL) project presently under construction at SLAC. The injector section, from drive-laser and RF photocathode gun through first bunch compressor chicane, was installed in fall 2006. Initial system commissioning with an electron beam has recently been completed. The second phase of construction, including second bunch compressor and full linac, is planned for 2008. In this paper, we report experimental results and experience gained during the first phase of machine commissioning. This includes the cathode, drive laser, RF photocathode gun, linac booster section, S-band and X-band RF systems, first bunch compressor, and the various beam diagnostics.

43 PARTICLE ACCELERATORS↗

Commissioning the LCLS Injector

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) project presently under construction at SLAC. The injector section, from drive laser and RF photocathode gun through first bunch compressor chicane, was installed in fall 2006. Initial system commissioning with an electron beam was completed in August 2007, with the goal of a 1.2-micron emittance in a 1-nC bunch clearly demonstrated. The second phase of commissioning, including second bunch compressor and full linac, is planned for 2008, with FEL commissioning in 2009. We report experimental results and experience gained in the first phase of commissioning, including the photo-cathode drive laser, RF gun, photocathode, S-band and X-band RF systems, first bunch compressor, and the various beam diagnostics.

43 PARTICLE ACCELERATORS↗

Observations of enhanced OTR signals from a compressed electron beam

The Advanced Photon Source (APS) injector complex includes an option for photocathode (PC) gun beam injection into the 450-MeV S-band linac. At the 150-MeV point, a 4-dipole chicane was used to compress the micropulse bunch length from a few ps to sub 0.5 ps (FWHM). Noticeable enhancements of the optical transition radiation (OTR) signal sampled after the APS chicane were then observed as has been reported in LCLS injector commissioning. A FIR CTR detector and interferometer were used to monitor the bunch compression process and correlate the appearance of localized spikes of OTR signal (5 to 10 times brighter than adjacent areas) within the beam image footprint. We have done spectral dependency measurements at 375 MeV with a series of band pass filters centered in 50-nm increments from 400 to 700 nm and observed a broadband enhancement in these spikes. Discussions of the possible mechanisms will be presented.

43 PARTICLE ACCELERATORS↗

The Development of the Linac Coherent Light Source RF Gun

The Linac Coherent Light Source (LCLS) is the first x-ray laser user facility based upon a free electron laser (FEL) requiring extraordinary beam quality to saturate at 1.5 angstroms within a 100 meter undulator.[1] This new type of light source is using the last kilometer of the three kilometer linac at SLAC to accelerate the beam to an energy as high as 13.6 GeV and required a new electron gun and injector to produce a very bright beam for acceleration. At the outset of the project it was recognized that existing RF guns had the potential to produce the desired beam but none had demonstrated it. Therefore a new RF gun or at least the modification of an existing gun was necessary. The parameters listed in Table 1 illustrate the unique characteristics of LCLS which drive the requirements for the electron gun as given in Table 2. The gun beam quality needs to accommodate emittance growth as the beam is travels through approximately one kilometer of linac and two bunch compressors before reaching the undulator. These beam requirements were demonstrated during the recent commissioning runs of the LCLS injector and linac [2] due to the successful design, fabrication, testing and operation of the LCLS gun. The goal of this paper is to relate the technical background of how the gun was able to achieve and in some cases exceed these requirements by understanding and correcting the deficiencies of the prototype s-band RF photocathode gun, the BNL/SLAC/UCLA Gun III. This paper begins with a brief history and technical description of Gun III and the Gun Test Facility (GTF) at SLAC, and studies of the gun's RF and emittance compensation solenoid. The work at the GTF identified the gun and solenoid deficiencies, and helped to define the specifications for the LCLS gun. Section 1.1.5 describes the modeling used to compute and correct the gun RF fields and Section 1.1.6 describes the use of these fields in the electron beam simulations. The magnetic design and measurements of the emittance compensation solenoid are discussed in Section 1.1.7. The novel feature of the LCLS solenoid is the embedded quadrupole correctors. The thermo-mechanical engineering of the LCLS gun is discussed in Section 1.1.8, and the cold and hot RF tests are described in Section 1.1.9. The results of this work are summarized and concluding remarks are given in Section 1.1.10.

43 PARTICLE ACCELERATORS↗

Longitudinal Bunch Lengthening Compensation in High Charge RF Photoinjector

In high charge RF photoinjectors for wakefield two beam acceleration studies, due to the strong longitudinal space charge, bunch lengthening between the photocathode and photoinjector exit is a critical issue. We present beam dynamics studies of bunch lengthening in an RF photoinjector for a high charge electron beam and describe methods to compensate the bunch lengthening to various degrees. In particular, the beam dynamics for bunch charge from 1nC to 30nC are studied for an S-band 2856 MHz photoinjector.

43 PARTICLE ACCELERATORS↗

Demonstration and Optimization of a Drive Laser for an X-Band Photoinjector

Recently, a drive laser for an S-band (2.86 GHz) rf photoinjector, designed to provide a pulse that has a flat temporal and spatial profile, has been built, commissioned, and put into service as part of the LLNL Compton-scattering monoenergetic {gamma}-ray source program. This laser is based on an all-fiber oscillator and front-end amplification system, and provides both the laser light to generate the electrons as well as the rf signal that is amplified to accelerate them. Now, a new 11.424 GHz photoinjector is being developed, which has required a revised design for the laser system. The higher frequency has placed more stringent requirements on the synchronization stability, delivered pulse length, and pulse rise times to maintain the desired emittance. Presented here are the overall design and measured performance of the current system and a discussion of what changes are being made to address observed shortcomings and more demanding requirements to make the system ready for the next-generation Compton-scattering monoenergetic {gamma}-ray source.

42 ENGINEERING↗

Superconducting RF Deflecting Cavity Design and Prototype for Short X-ray Pulse Generation

Deflecting RF cavities are proposed to be used in generating short x-ray pulses (on ~1-picosecond order) at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL)* using a novel scheme by Zholents**. To meet the required deflecting voltage, impedance budget from higher order, lower order and the same order modes (HOM, LOM and SOM) of the APS storage ring, extensive deflecting cavity design studies have been conducted with numerical simulations and cavity prototypes. In this paper, we report recent progress on a single cell S-band (2.8-GHz) superconducting deflecting cavity design with waveguide damping. A copper and a niobium prototype cavity were fabricated and tested, respectively to benchmark the cavity and damping designs. A new damping scheme has been proposed which provides stronger damping to both HOM and LOM by directly coupling to a damping waveguide on the cavity equator.

43 PARTICLE ACCELERATORS↗

High Brightness Electron Beam Studies at the NSLS SDL

Experimental optimization of electron beam brightness at the NSLS SDL is reported in this paper. Using a high quantum efficiency (QE) Mg metal cathode and the S-band BNL-type RF gun, we have systematically studied electron beams transverse and longitudinal emittance. The measured thermal emittance for the Mg cathode is 0.85{+-}0.04 mm-mrad/mm, which contradicts the current thermal emittance model. For a 50 pC beam, measured normalized transverse and longitudinal RMS emittance are 0.6 mm-mrd and 5.2 ps-keV, respectively. The smallest projected transverse emittance observed for a 20 pC charge is 0.15 {+-} 0.02 mm-mrad.

43 PARTICLE ACCELERATORS↗

The Galileo Spacecraft: A Communications Legacy for Future Space Flight

The Galileo mission to Jupiter has implemented a wide range of telecommunication improvements in response to the loss of it's high gain antenna. Among the communications enhancements that have been made are the use of advanced compression techniques, packetized telemetry, new error correcting codes and algorithms, more efficient modulation, variable transmission data rates, routine ground antenna arraying (even between continents,) extremely sensitive ground receivers, and non-real-time automated data reconstruction. This telecommunications legacy of Galileo will aid in our abillity to conduct a meaningful exploration of the solar system, and beyond, at a reasonable cost.

Galileo↗