Beyond Price Taker: Optimizing Integrated Energy Systems Considering Market/Grid Interactions

Integrated Energy Systems (IES) combine two or more processes to increase the efficiency, flexibility of operation, and the overall reliability. However, analyzing IESs in volatile electricity markets is challenging, since the volatility in electricity prices makes the conventional levelized cost-type analysis less realistic. This work presents two approaches to address the challenge: price-taker and a surrogates-based approach for incorporating market interactions. The price-taker approach formulates a multiperiod optimization problem that takes the time-varying electricity prices into account, and solves the optimization problem to determine the optimal operational schedule that maximizes the chosen economic metric. This approach is successfully applied to investigate the performance of flexible power and hydrogen co-production systems. The market surrogates approach trains a machine learning model to predict the market behavior as a function of the characteristics of the IES. The trained surrogate model is used to optimize the design and operation of the given IES in an electricity market. This approach is demonstrated on a case study involving a nuclear power plant retrofitted with a low-temperature electrolysis unit to co-produce power and hydrogen.

beyond price taker↗

Design optimization of an ethanol heavy-duty engine using design of experiments and bayesian optimization

Diesel-fueled engines still hold a large market share in the medium and heavy-duty transportation sector. However, the increase in fossil fuel prices and the strict emission regulations are leading engine manufacturers to seek cleaner alternatives without a compromise in performance. Alcohol-based fuels, such as ethanol, offer a promising alternative to diesel fuel in meeting regulatory demands. Ethanol provides cleaner combustion and lower levels of soot due to its chemical properties, in particular its lower level of carbon content. In addition, the stoichiometric operating conditions of alcohol fueled engines enable the mitigation of NOx emissions in aftertreatment stage. With the promise of retrofitting diesel engines to run on ethanol to reduce emissions, the thermal efficiency of these engines remains the primary optimization target. In order to find the optimal ethanol-fueled engine design that maximizes the thermal efficiency, a large design space needs to be investigated using engineering tools. In this study, previous research by the authors on optimizing the design of a single-cylinder ethanol-fueled engine was extended to explore the design space for a heavy-duty multi-cylinder engine configuration. A heavy-duty engine setup with multiple operating conditions at different engine speeds and loads were considered. A design optimization analysis was performed to identify the potential designs that maximize the indicated thermal efficiency in an ethanol-fueled compression ignition engine. First, a computational fluid dynamics (CFD) model of the engine was validated using experimental data for four drive cycle points. Using a design of experiments (DoE) approach and a parameterized piston bowl geometry, the model was then exercised to explore the relationship among geometric features of the piston bowl and spray targeting angle and indicated thermal efficiency across all tested operating conditions. After evaluating 165~candidate designs, a piston bowl geometry was identified that yielded an increase between 1.3 to 2.2 percentage points in indicated thermal efficiency for all tested conditions, while satisfying the operational design constraints for peak pressure and maximum pressure rise rate. The increased performance was attributed to enhanced mixing that led to the formation of a more homogeneous distribution of in-cylinder temperature and equivalence ratio, higher combustion temperatures, and shorter combustion duration. Finally, a Bayesian optimization (BOpt) analysis was employed to find the optimal piston bowl geometry with a fixed spray injector angle for one of the operating conditions. Using BOpt, a piston candidate was identified that resulted in a 1.9~percentage point increase in thermal efficiency from the baseline design, yet only required 65\% of the design samples investigated using the DoE approach.

Tekgul, Bulut↗

Development of novel techniques for non-invasive air leakage and moisture detection in building envelopes

Unwanted air leakage and moisture in building envelopes can cause high energy consumption, detrimental indoor air quality, poor occupant comfort, and reduction in building material durability. High moisture can cause rot and mold, leading to costly and time-consuming repairs that add to the carbon burden of the building envelope. Novel detection techniques for locating and measuring air leakage flow and areas of high moisture in building envelopes will be presented. The techniques are easy, fast, and non-destructive which can enable quick building envelope assessment, foster retrofits, and lead to energy savings and carbon emission reduction.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

UAV Resilience Against Stealthy Attacks

Unmanned aerial vehicles (UAVs) depend on software components to automate dangerous or critical missions; these components are then a desirable target for adversaries seeking to sabotage the UAV. Some work has been done to prevent an attacker who has either compromised a ground control station or parts of a UAV’s software from sabotaging the vehicle, but not both. We present an architecture running a UAV software stack with runtime monitoring and seL4-based software isolation that prevents attackers from both exploiting software bugs and utilizing stealthy attacks. Our architecture retrofits legacy UAVs and secures the popular MAVLink protocol, making it widely applicable for UAVs to adopt.

42 - ENGINEERING↗

Design and Demonstration of a NH3-Fueled Two-Stroke Uniflow Engine for Greenhouse Gas Reduction

The maritime shipping industry is growing increasingly interested in both low and non-carbon-containing fuels to meet future greenhouse gas emission targets. Specifically of interest is ammonia, as it has a relatively high volumetric energy density compared to other future fuels, such as hydrogen, making it more economical to transport. The robust engine architecture of low-speed two-stroke marine engines makes them an ideal candidate for ammonia fuel, overcoming many of the issues surrounding its poor ignitability and low flame speed. If emissions and fueling system challenges can be addressed, retrofits of current low-speed two-stroke dual-fuel engines represent a viable pathway for bringing ammonia engines to market. This study explores these technical hurdles by describing the design, analysis, and experimental validation of a single cylinder research engine converted to operate on ammonia fuel. The engine is a reduced-scale uniflow two-stroke marine engine with two previous hardware configurations available – diesel and high-pressure CNG dual-fuel. A concept study was used to evaluate possible ammonia-fueled engine architectures and the associated tradeoffs and design considerations. With the chosen architecture, low-pressure dual fuel, 1D and 3D analysis tools were used to inform hardware selection and to determine hardware configurations which minimized ammonia-slip. In addition to these considerations the hardware and engine configuration were designed to provide a versatile and robust testing platform. This includes options to test both gaseous and liquid ammonia injection, as well as a wide range of performance parameters such as AFR, swirl, valve timing, SOI, and many others. Design constraints imposed by the existing engine hardware necessitated an iterative loop between design and analysis toolsets, ultimately converging on a final design for the ammonia-conversion hardware. The engine was rebuilt with the new hardware and evaluated in an engine test cell. A new control strategy developed and flashed onto a prototyping electronic control unit allowed for full control over all engine parameters. An initial calibration was developed, providing test data for validation of the engine 1D and 3D models. The impact of the design choices on engine operability and the ability to meet program targets is discussed as well as opportunities for further optimization of the ammonia-conversion hardware, informed by the validated models.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

Experimental Investigation of Air-Fuel Equivalence Ratio Effects on Advanced Dual-fuel Diesel/Ammonia Combustion on a Single-Cylinder Medium-Duty Diesel Engine at High Load

Ammonia (NH3) has gathered a lot of interest as a low-lifecycle-carbon fuel in sectors with high weight and distance requirements, such as shipping. The International Maritime Organization (IMO) mandates a 70-80% greenhouse gas (GHG) reduction by 2040, which is only possible with advanced engine technologies and fuels like NH3. Prior research studies at the US Department of Energy’s Oak Ridge National Laboratory have shown strong performance with NH3 under dual-fuel mode using conventional diesel combustion (CDC) manifold air pressure (MAP) settings. Diesel airflow was initially used to simplify retrofitting (no turbocharger modification), which resulted in air-fuel equivalence ratios (λ) greater than 1.5. To characterize potential improvements in dual-fuel NH3 combustion performance at richer in-cylinder conditions, a global λ sweep using a diesel pilot ignition (DPI) strategy with diesel fuel injected near top-dead center (TDC) and a reactivity-controlled compression ignition (RCCI) injection strategy with diesel fuel injected earlier during the compression stroke were compared. The experiments were conducted at 1200 RPM and 12.6 bar (75% load), and λ was varied by decreasing the commanded air flow to the engine at greater than 90% ammonia energy substitution (AES) level. A diesel injection timing sweep was conducted for both the combustion modes at fixed λ, and the timing with the lowest engine-out N2O emissions was identified. The results indicated an optimal balance between CO2, eq and thermal efficiency benefits for both DPI and RCCI injection strategy cases compared to CDC at a λ of 1.4. The indicated N-based emissions exhibited a strong correlation to the ratio of CA5–50 and ignition delay for DPI, but no apparent trend emerged for the RCCI injection strategy at the tested boundary conditions.

Tyrewala, Daanish [ORNL] (ORCID:0000000208599324)↗

SHF: Symmetrical Hierarchical Forest with Pretrained Vision Transformer Encoder for High-Resolution Medical Segmentation

This paper presents a novel approach to addressing the long-sequence problem in high-resolution medical images for Vision Transformers (ViTs). Using smaller patches as tokens can enhance ViT performance, but quadratically increases computation and memory requirements. Therefore, the common practice for applying ViTs to high-resolution images is either to: (a) employ complex sub-quadratic attention schemes or (b) use large to medium-sized patches and rely on additional mechanisms within the model to capture the spatial hierarchy of details. We propose Symmetrical Hierarchical Forest (SHF), a lightweight approach that adaptively patches the input image to increase token information density and encode hierarchical spatial structures into the input embedding. We then apply a reverse depatching scheme to the output embeddings of the transformer encoder, eliminating the need for convolution-based decoders. Unlike previous methods that modify attention mechanisms or use a complex hierarchy of interacting models, SHF can be retrofitted to any ViT model to allow it to learn the hierarchical structure of details in high-resolution images without requiring architectural changes. Experimental results demonstrate significant gains in computational efficiency and performance: on the PAIP WSI dataset, we achieved a 3∼32×speedup or a 2.95%∼7.03% increase in accuracy (measured by Dice score) at a 64K2 resolution with the same computational budget, compared to state-of-the-art production models. On the 3D medical datasets BTCV and KiTS, training was 6×faster, with accuracy gains of 6.93% and 5.9%, respectively, compared to models without SHF.

Zhang, Enzhi [Hokkaido University, Japan]↗

Mesoporous optically clear heat insulators for sustainable building envelopes

Mesoporous materials exhibit highly controlled nanoscale structures, often templated by liquid crystalline assemblies of surfactants, with emergent and often designable physical properties. However, scaling their fabrication to be suitable for uses like envelopes of buildings is challenging. Here we describe fabrication of flexible square-meter-sized films and multi-centimeter-thick slabs made of three-dimensional spatial graphs of mesopore tubes having all structural features under 50 nanometers. Solution-based kinetic fabrication process templates growing networks of cylindrical surfactant micelles with thin tubes of polysiloxane forming gel networks and, upon replacing surfactants and solvents with air, yields lightweight materials with >99% visible-range optical transparency and ~10 mW K-1m-1 thermal conductivity. Such predesigned metamaterials enable transparent thermal barriers for wall-grade insulated glass units, square-meter window retrofits and unconcentrated solar thermal energy harnessing.

14 SOLAR ENERGY↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Economic Benefits of Alternative Fuels in Rural Alabama

This fact sheet provides an overview of potential alternative fuel vehicle operational cost savings, opportunities to generate revenue for the state and income for individuals, and several examples of alternative fuels supporting jobs in Alabama. Alternative transportation fuels could potentially provide economic benefits to rural Alabama by lowering operating costs for vehicle owners and creating new revenue streams and job opportunities for fuel providers, technicians, and dealerships. The use of electricity, compressed natural gas (CNG), liquefied natural gas (LNG), liquefied petroleum gas (LPG or propane) could result in reduced fuel costs and maintenance expenses for both public and private fleets, as well as individual consumers. Fleet operators often invest in private fueling infrastructure, while publicly accessible stations could attract traffic and commerce to local businesses and communities. Technicians capable of retrofitting alternative fuels and maintaining the vehicles and fueling infrastructure could develop business opportunities as well, but they require special training and often certifications. These cost savings and increased revenues may be recirculated through the economy and impact more than just the beneficiaries listed above.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Do Electricity Pricing Programs Impact the Selection of Energy Efficiency Measures? - A Case Study with U.S. Medium Office Buildings

Building owners usually select energy efficiency measures (EEMs) by referring to return on investment (ROI). Current studies tend to apply static energy price to estimate ROI. However, more and more buildings are adopting dynamic electricity pricing programs. To understand how electricity pricing programs impact the selection of EEMs, this paper presents an analysis of the ROIs of EEMs under different pricing programs using U.S. medium office buildings as an example. Eight EEMs in four typical cities are selected as case studies. Considering five electricity pricing programs scenarios (one static program and four dynamic programs), EEMs are selected based on their ROIs. The main findings are: (1) The ROIs of EEMs change under different pricing programs. (2) In Honolulu, Buffalo, and Denver, replacing interior fixtures with higher-efficiency fixtures has a significantly higher ROI than the rest EEMs under all five pricing programs. However, the ROI of this EEM in Honolulu ranges from 28% to 47% for different pricing programs. (3) Similarly, in Fairbanks, replace heating coil with higher-efficiency coil produce higher ROI than the rest under all five pricing programs. (4) For other EEMs, their ROI rankings vary according to electricity pricing programs.

demand response↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.