Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Residential solar-heating system-design package

Design package for modular solar heating system includes performance specifications, design data, installation guidelines, and other information that should be valuable to those interested in system (or similar systems) for projected installation. When installed in insulated "energy saver" home, system can supply large percentage of total energy needs of building.

Source record↗

Design and operation of a solar heating and cooling system for a residential size building

The first year of operation of solar house is discussed. Selected design information, together with a brief system description is included. The house was equipped with an integrated solar heating and cooling system which uses fully automated state-of-the art. Evaluation of the data indicate that the solar house heating and cooling system is capable of supplying nearly 100 percent of the thermal energy required for heating and approximately 50 percent of the thermal energy required to operate the absorption cycle air conditioner.

Littles, J. W.↗

Fuel cell on-site integrated energy system parametric analysis of a residential complex

A parametric energy-use analysis was performed for a large apartment complex served by a fuel cell on-site integrated energy system (OS/IES). The variables parameterized include operating characteristics for four phosphoric acid fuel cells, eight OS/IES energy recovery systems, and four climatic locations. The annual fuel consumption for selected parametric combinations are presented and a breakeven economic analysis is presented for one parametric combination. The results show fuel cell electrical efficiency and system component choice have the greatest effect on annual fuel consumption; fuel cell thermal efficiency and geographic location have less of an effect.

Simons, S. N.↗

Fuel cell on-site integrated energy system parametric analysis of a residential complex

The use of phosphoric acid fuel cell powerplant to provide all the electricity required by an 81-unit garden apartment complex is studied. Byproduct heat is recovered and provides some of the heat required by the complex. The onsite integrated energy system contains energy conversion equipment including combinations of compression and absorption chillers, heat pumps, electric resistance heaters, and thermal storage. The annual fuel requirement for several onsite integrated energy systems as well as the fuel cell breakeven cost for one specific system were calculated. It is found that electrical efficiency cannot be traded off against thermal efficiency without paying a penalty in system efficiency.

Simons, S. N.↗

Analysis of a fuel cell on-site integrated energy system for a residential complex

The energy use and costs of the on-site integrated energy system (OS/IES) which provides electric power from an on-site power plant and recovers heat that would normally be rejected to the environment is compared to a conventional system purchasing electricity from a utility and a phosphoric acid fuel cell powered system. The analysis showed that for a 500-unit apartment complex a fuel OS/IES would be about 10% more energy conservative in terms of total coal consumption than a diesel OS/IES system or a conventional system. The fuel cell OS/IES capital costs could be 30 to 55% greater than the diesel OS/IES capital costs for the same life cycle costs. The life cycle cost of a fuel cell OS/IES would be lower than that for a conventional system as long as the cost of electricity is greater than $0.05 to $0.065/kWh. An analysis of several parametric combinations of fuel cell power plant and state-of-art energy recovery systems and annual fuel requirement calculations for four locations were made. It was shown that OS/IES component choices are a major factor in fuel consumption, with the least efficient system using 25% more fuel than the most efficient. Central air conditioning and heat pumps result in minimum fuel consumption while individual air conditioning units increase it, and in general the fuel cell of highest electrical efficiency has the lowest fuel consumption.

Simons, S. N.↗

Residential solar hot water system--Tempe, Arizona

Domestic hot water for single story home is heated by two 4 by 8 foot solar collectors. Solar energy saved 5.54 million Btu in six month period; savings with increased water consumption would be significantly higher.

Source record↗

Residential solar heating installation--Stillwater, Minnesota

Report presents installer guidelines for network subsystems, including filling and testing. Information on operating procedures, controls, caution requirements, and routine scheduled maintenance is included as written procedures, schematics, detailed drawings, and manufacturer's component data.

Source record↗

Residential solar-heating system uses pyramidal optics

Report describes reflective panels which optimize annual solar energy collection in attic installation. Subunits include collection, storage, distribution, and 4-mode control systems. Pyramid optical system heats single-family and multi-family dwellings.

Source record↗

Residential system--Lansing, Michigan

Air collectors are combined with water storage to supply 15 percent of space-heating and hot-water load to residence. Report discusses typical system operation, energy savings, and miantenance for 11 month period. Although unusual combination of water storage with air collecting medium creates loss of heat exchanging efficiency, net energy savings were 21 million Btu.

Source record↗

Residential photovoltaic module and array requirements study, appendices

Regional building code variations, federal and city codes, and the national electric code are reviewed for their possible effects on the design of photovoltaic modules. Problems that photovoltaic arrays may impose on the insurability of residences are also discussed. Mounting configurations are developed for the modules, and grounding, wiring, terminal, and voltage requirements are established. Installation and materials costs are presented along with performance criteria.

Nearhoof, S. L.↗

An assessment of alternative fuel cell designs for residential and commercial cogeneration

A comparative assessment of three fuel cell systems for application in different buildings and geographic locations is presented. The study was performed at the NASA Lewis Center and comprised the fuel cell design, performance in different conditions, and the economic parameters. Applications in multifamily housing, stores and hospitals were considered, with a load of 10kW-1 MW. Designs were traced through system sizing, simulation/evaluation, and reliability analysis, and a computer simulation based on a fourth-order representation of a generalized system was performed. The cells were all phosphoric acid type cells, and were found to be incompatible with gas/electric systems and more favorable economically than the gas/electric systems in hospital uses. The methodology used provided an optimized energy-use pattern and minimized back-up system turn-on.

Wakefield, R. A.↗

Detecting residential land-use development at the urban fringe

Problems associated with the use of Landsat multispectral scanner (MSS) imagery for the detection of urban growth and land use patterns are discussed. The presence of vegetation, either original or added between scanning periods, has been found to dramatically effect the range of signatures in a given area. Different land use developmental stages have been successfully identified by means of 1:50,000 scale panchromatic aerial photography, a resolution only considered possible by spaceborne instrumentation with the advent of the Landsat D satellite. Textural information generated through the grey-tone spatial-dependency matrix for the Landsat band 5 data is compared for different years and a change detection algorithm is described. It is found that the addition of vegetation during development after the removal of natural vegetation resulted in error of omission in the single band data, which must therefore only be used in concert with other data sources.

Jensen, J. R.↗

Integrating Residential Photovoltaics With Power Lines

Report finds rooftop solar-cell arrays feed excess power to electric-utility grid for fee are potentially attractive large-scale application of photovoltaic technology. Presents assessment of breakeven costs of these arrays under variety of technological and economic assumptions.

Borden, C. S.↗

The Timing of Noise-Sensitive Activities in Residential Areas

Data from a nationally representative survey of time use was analyzed to provide estimates of the percentage of the population which is engaged in noise sensitive activities during each hour of the day on weekdays, Fridays, Saturdays and Sundays. Estimates are provided of the percentage engaged in aural communication activities at home, sleeping at home, or simply at home. The day can be roughly divided into four noise sensitivity periods consisting of two relatively steady state periods, night and day and the early morning and evening transition periods. Weekends differ from weekdays in that the morning transition period is one hour later and the numbers of people engaged in aural communication during the day at home are approximately one-half to three-quarters greater. The extent and timing of noise sensitive activities was found to be similiar for all parts of the United States, for different sizes of urban areas, and for the three seasons surveyed (September through May). The timing of activity periods does not differ greatly by sex or age even though women and people over 65 are much more likely to be at home during the daytime.

Fields, J. M.↗

Residential Photovoltaic/Thermal Energy System

Proposed system supplies house with both heat and electricity. Pair of reports describes concept for self-sufficient heating, cooling, and power-generating system for house. Panels on walls of house provide hot water, space heating, and heat to charge heat-storage system, and generate electricity for circulation pumps and fans. Roof panels generate electricity for household, operate heat pump for summer cooling, and provide supplementary winter heating via heat pump, using solar-cell cooling-fluid loop. Wall and roof panels used independently.

Selcuk, M. K.↗

Attitudinal Responses to Changes in Noise Exposure in Residential Communities

The purpose of this study is (1) to investigate the current body of knowledge encompassing two related topics: (a) to what extent can we reliably predict the change in people's attitudes in response to an abrupt change in noise exposure, and (b) after the change, is there a decay in the abrupt-change effect whereby people's attitudes slowly shift from their initial reaction to a steady-state value? and (2) to provide recommendations for any future work that may be needed. The literature search located 23 studies relating to one or both of the above topics. These prior studies shed considerable light on the current ability to predict initial reaction and decay effects. The literature makes one point very clear: Great care in both experimental design and data analysis is necessary to produce credible, convincing findings, both in the reanalysis of existing data and for planning future data acquisition and analysis studies. New airport studies must be designed to minimize nuisance variables and avoid past design features that may have introduced sufficient unexplained variance to mask sought after effects. Additionally, the study must be designed to tie in with previous investigations by incorporating similar survey questions and techniques.

Horonjeff, Richard D.↗