Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Lensing as a probe of early universe: from CMB to galaxies

The Cosmic Microwave Background (CMB) radiation lensing is a promising tool to study the physics of early universe. In this work we probe the imprints of deviations from isotropy and scale invariance of primordial curvature perturbation power spectrum on CMB lensing potential and convergence. Specifically, we consider a scale-dependent hemispherical asymmetry in primordial power spectrum. We show that the CMB lensing potential and convergence and also the cross-correlation of the CMB lensing and late time galaxy convergence can probe the amplitude and the scale dependence of the dipole modulation. As another example, we consider a primordial power spectrum with local feature. We show that the CMB lensing and the cross-correlation of the CMB lensing and galaxy lensing can probe the amplitude and the shape of the local feature. We show that the cross correlation of CMB lensing convergence and galaxy lensing is capable to probe the effects of local features in power spectrum on smaller scales than the CMB lensing. Finally we showed that the current data can constrain the amplitude and moment dependence of dipole asymmetry.

79 ASTRONOMY AND ASTROPHYSICS↗

Strong-field- versus weak-field-ionization pump-probe spectroscopy

Ionization can serve as a universal probe of excited-state dynamics in molecules, such as internal conversion, dissociation, and isomerization. These processes are of fundamental importance to a wide array of dynamics in biology, chemistry, and physics. In recent years, there has been significant debate about the relative merits of strong-field ionization (SFI), which involves multiphoton absorption, versus weak-field ionization (WFI), where a single photon is absorbed, as probes of these dynamics. SFI is advantageous because it uses wavelengths that are relatively easy to generate, and one can always ionize the molecule with sufficient intensity. However, for SFI it is difficult to calculate observables, such as the time-dependent ion yield, since the calculation of the ionization dynamics including multiphoton processes is computationally expensive and difficult to carry out for many molecular geometries. WFI has the advantage that calculations of observables are tractable. However, the generation and implementation of the appropriate wavelengths (photon energies) can be challenging, and the fixed energy of the probe can lead to technical complications in following the dynamics from excited states back down to the ground state. Here we present a quantitative comparison of the two approaches for following the excited-state dynamics of two molecules, diiodomethane and uracil. The combination of internal conversion and dissociation in these molecules provides an ideal comparison of WFI and SFI as a probe. We compare the measurements with calculations of the dynamics. Furthermore, our work indicates that while SFI and WFI provide qualitatively similar information about the excited-state dynamics, only WFI results can be compared quantitatively with present-day calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hyperfine interactions and local environment of {sup 57}Fe probe atoms in perovskite CaMn{sub 7}O{sub 12}

Moessbauer spectroscopy has been applied for studying the local environment of {sup 57}Fe probe atoms within iron-doped CaMn{sub 7}O{sub 12} manganite with a perovskite-like structure. The {sup 57}Fe spectra recorded in the paramagnetic temperature range 90 K<T<380 K, where CaMn{sub 7}O{sub 12} has a rhombohedral structure (R3), were discussed supposing Fe{sup 3+} probe cations to replace manganese in the octahedral (Mn{sup 3+}O{sub 6}) and (Mn{sup 4+}O{sub 6}) polyhedra. A very small (<3%) part of Fe{sup 3+} probe cations characterized by very large quadrupole splitting ({approx}2 mm/s) suggests that a few amounts of {sup 57}Fe probe can be substituted for Mn{sup 3+} in the (9e) positions with approximately a square planar surrounding. In the temperature range 380 K<T<450 K, the {sup 57}Fe Moessbauer spectra undergo a sharp change which can be due to a formation (at T{sub CO}{approx}380 K) and a gradual growth with temperature of the cubic manganite phase (Im3). At T{>=}450 K, the {sup 57}Fe spectrum reveals single Fe{sup 3+} sites in an oxygen symmetric octahedral surrounding. This can be well explained by a fast electron exchange Mn{sup 3+}{r_reversible}Mn{sup 4+}, leading to the crystallographic equivalence of all MnO{sub 6} positions. At the temperature range T<T{sub M2} (=90 K), an appearance of the distributions of the hyperfine magnetic field values at the {sup 57}Fe nucleus up to {approx}350 kOe (at 77.4 K) was observed. This result is an independent experimental evidence of magnetic ordering in the manganese sublattice.

36 MATERIALS SCIENCE↗

Achieving atomic resolution magnetic dichroism by controlling the phase symmetry of an electron probe

The calculations presented here reveal that an electron probe carrying orbital angular momentum is just a particular case of a wider class of electron beams that can be used to measure electron magnetic circular dichroism (EMCD) with atomic resolution. It is possible to obtain an EMCD signal with atomic resolution by simply breaking the symmetry of the electron probe phase front using the aberration-corrected optics of a scanning transmission electron microscope. The probe’s required phase distribution depends on the sample’s magnetic symmetry and crystal structure. The calculations indicate that EMCD signals that use the electron probe’s phase are as strong as those obtained by nanodiffraction methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

Resonant ultrasound spectroscopy probe for in-situ neutron scattering measurements

Resonant ultrasound spectroscopy (RUS) is an efficient, nondestructive technique to study the elastic properties of solids. A low-temperature (2-300 K) probe has been assembled and tested at the NOMAD beamline at the Spallation Neutron Source at Oak Ridge National Laboratory to assess the probe's neutronic properties, data acquisition system, and compatibility with existing sample environment. A case study on a bulk metallic glass, La 65 Cu 20 Al 10 Co 5, served to benchmark both hardware and software developments. The elastic constants of the metallic glass were determined as a function of temperature between 4 and 300 K and were used to guide neutron diffraction measurements at NOMAD. Tracking of a specific RUS peak center frequency and width enabled live monitoring of the sample temperature evolution that lagged thermometry by upwards of 40 K near room temperature. Assembly of a high-temperature (300-875 K) probe is underway and both probes are scheduled to be available to users by late-2021. Our aim is to provide users with live monitoring of an intrinsic variable at the neutron scattering beamlines, in addition to existing controls, to monitor the state of their samples and its elastic moduli and make informed decisions in real time.

Torres, James↗

Anisotropy and probe-medium interactions in the microrheology of nematic fluids.

A theoretical formalism is presented to analyze and interpret microrheology experiments in anisotropic fluids with nematic order. The predictions of that approach are examined in the context of a simple coarse-grained molecular model which is simulated using nonequilibrium molecular dynamics calculations. The proposed formalism is used to study the effect of confinement, the type of anchoring at the probe-particle surface, and the strength of the nematic field on the rheological response functions obtained from probe-particle active microrheology. As expected, a stronger nematic field leads to increased anisotropy in the rheological response of the material. It is also found that the defect structures that arise around the probe particle, which are determined by the type of anchoring and the particle size, have a significant effect on the rheological response observed in microrheology simulations. Independent estimates of the bulk dynamic modulus of the model nematic fluid considered here are obtained from small-amplitude oscillatory shear simulations with Lees Edwards boundary conditions. The results of simulations indicate that the dynamic modulus extracted from particle-probe microrheology is different from that obtained in the absence of the particle, but that the differences decrease as the size of the defect also decreases. Importantly, the results of the nematic microrheology theory proposed here are in much closer agreement with simulations than those from earlier formalisms conceived for isotropic fluids. As such, it is anticipated that the theoretical framework advanced in this study could provide a useful tool for interpretation of microrheology experiments in systems such as liquid crystals and confined macromolecular solutions or gels.

Cordoba, Andres↗

Ground-state pump-probe spectroscopy

The absorption/gain spectrum of a weak probe field is theoretically analyzed for an atomic three-level {lambda} system driven by a strong pump field and perturbed by collisions with buffer-gas atoms. It is assumed that both pump and probe drive the same transition. When the dark state is sufficiently long lived, the probe spectrum exhibits an extremely narrow (possibly subnatural-width) resonance. It is shown that coherence-preserving collisions drastically (both qualitatively and quantitatively) change the probe absorption spectrum even at a low collision frequency, when Dicke narrowing is negligible. Strong coherence effects on the resonance structure at low gas pressures is explained by a change in refractive index due to coherence-preserving collisions for particles in the resonant velocity group.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Processing of Ice Cloud In Situ Data Collected by Bulk Water, Scattering, and Imaging Probes: Fundamentals, Uncertainties, and Efforts toward Consistency

Abstract In situ observations of cloud properties made by airborne probes play a critical role in ice cloud research through their role in process studies, parameterization development, and evaluation of simulations and remote sensing retrievals. To determine how cloud properties vary with environmental conditions, in situ data collected during different field projects processed by different groups must be used. However, because of the diverse algorithms and codes that are used to process measurements, it can be challenging to compare the results. Therefore it is vital to understand both the limitations of specific probes and uncertainties introduced by processing algorithms. Since there is currently no universally accepted framework regarding how in situ measurements should be processed, there is a need for a general reference that describes the most commonly applied algorithms along with their strengths and weaknesses. Methods used to process data from bulk water probes, single-particle light-scattering spectrometers and cloud-imaging probes are reviewed herein, with emphasis on measurements of the ice phase. Particular attention is paid to how uncertainties, caveats, and assumptions in processing algorithms affect derived products since there is currently no consensus on the optimal way of analyzing data. Recommendations for improving the analysis and interpretation of in situ data include the following: establishment of a common reference library of individual processing algorithms, better documentation of assumptions used in these algorithms, development and maintenance of sustainable community software for processing in situ observations, and more studies that compare different algorithms with the same benchmark datasets.

54 ENVIRONMENTAL SCIENCES↗

Oxygen torus and its coincidence with EMIC wave in the deep inner magnetosphere: Van Allen Probe B and Arase observations

We investigate the longitudinal structure of the oxygen torus in the inner magnetosphere for a specific event found on 12 September 2017, using simultaneous observations from the Van Allen Probe B and Arase satellites. It is found that Probe B observed a clear enhancement in the average plasma mass (M) up to 3–4 amu at L = 3.3–3.6 and magnetic local time (MLT) = 9.0 h. In the afternoon sector at MLT ~ 16.0 h, both Probe B and Arase found no clear enhancements in M. This result suggests that the oxygen torus does not extend over all MLT but is skewed toward the dawn. Since a similar result has been reported for another event of the oxygen torus in a previous study, a crescent-shaped torus or a pinched torus centered around dawn may be a general feature of the O + density enhancement in the inner magnetosphere. We newly find that an electromagnetic ion cyclotron (EMIC) wave in the H + band appeared coincidently with the oxygen torus. From the lower cutoff frequency of the EMIC wave, the ion composition of the oxygen torus is estimated to be 80.6% H + , 3.4% He + , and 16.0% O + . According to the linearized dispersion relation for EMIC waves, both He + and O + ions inhibit EMIC wave growth and the stabilizing effect is stronger for He + than O + . Therefore, when the H + fraction or M is constant, the denser O + ions are naturally accompanied by the more tenuous He + ions, resulting in a weaker stabilizing effect (i.e., larger growth rate). From the Probe B observations, we find that the growth rate becomes larger in the oxygen torus than in the adjacent regions in the plasma trough and the plasmasphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Rotation-as-fast-axis scanning-probe x-ray tomography: the importance of angular diversity for fly-scan modes

Here, we investigate the effects of angular diversity on image-reconstruction quality of scanning-probe x-ray tomography for both fly- and step-mode data collection. We propose probe-coverage maps as a tool for both visualizing and quantifying the distribution of probe interactions with the object. We show that data sampling with more angular diversity yields better tomographic image reconstruction as long as it does not come at the cost of not covering some voxels in the object. Therefore, for fly-mode data collection, rotation-as-fast-axis (RAFA) trajectories are superior to raster or other non-RAFA trajectories because they allow for the increasing of angular diversity without sacrificing spatial coverage uniformity. In contrast, for step-mode data collection and a fixed measurement budget, increasing angular diversity can come at the cost of not covering some voxels, and may not be desired. This study has implications for how scanning-probe microscopes should be collecting data in order to make the most of limited resources.

47 OTHER INSTRUMENTATION↗

Development of time-domain differential Raman for transient thermal probing of materials

A novel transient thermal characterization technology is developed based on the principles of transient optical heating and Raman probing: time-domain differential Raman. It employs a square-wave modulated laser of varying duty cycle to realize controlled heating and transient thermal probing. Very well defined extension of the heating time in each measurement changes the temperature evolution profile and the probed temperature field at μs resolution. Using this new technique, the transient thermal response of a tipless Si cantilever is investigated along the length direction. A physical model is developed to reconstruct the Raman spectrum considering the temperature evolution, while taking into account the temperature dependence of the Raman emission. By fitting the variation of the normalized Raman peak intensity, wavenumber, and peak area against the heating time, the thermal diffusivity is determined as 9.17 × 10⁻⁵, 8.14 × 10⁻⁵, and 9.51 × 10⁻⁵ m²/s. These results agree well with the reference value of 8.66 × 10⁻⁵ m²/s considering the 10% fitting uncertainty. The time-domain differential Raman provides a novel way to introduce transient thermal excitation of materials, probe the thermal response, and measure the thermal diffusivity, all with high accuracy.

36 MATERIALS SCIENCE↗

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as a probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, which, due to various imperfections creates high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Nikitin, Viktor↗

High-energy, low-jitter, narrowband ps probe laser for kHz-rate fs/ps coherent anti-Stokes Raman scattering

Hybrid fs/ps coherent anti-Stokes Raman scattering (CARS) thermometry often utilizes ps probe pulses derived from pulse shaping or spectrally filtering the primary laser source or by synchronization with a low repetition rate external laser. This results in limited energy, spectral resolution, and/or repetition rate of the ps probe. In this work, a master-oscillator power-amplifier (MOPA) laser was synchronized to the oscillator of a Ti:sapphire regenerative amplifier to achieve high-energy (600 µJ), narrowband (58 ps) probe pulses at kHz repetition rates. Furthermore, temporal filtering allows the pulse characteristics to be adjusted for each application. At 25 Torr, relevant to high-speed flows, the kHz-rate MOPA system generated signal-to-noise ratios 3× higher in nitrogen and had improved precision relative to a 10 ps probe derived from spectral filtering and the power-amplifier. The MOPA system also enabled single-shot ro-vibrational hybrid fs/ps CARS thermometry in 650 K heated air.

47 OTHER INSTRUMENTATION↗

Electrochemical strain microscopy: Probing ionic and electrochemical phenomena in solids at the nanometer level

Atomistic and nanometer scale mechanisms of electrochemical reactions and ionic flows in solids in the nanometer-micron range persist as terra incognito in modern science. While structural and electronic phenomena are now accessible to electron and scanning probe microscopy (SPM) techniques, probing nanoscale electrochemistry requires the capability to probe local ionic currents. Here, we discuss principles and applications of electrochemical strain microscopy (ESM), a technique based on probing minute deformations induced by electric bias applied to an SPM tip. ESM imaging and spectroscopy are illustrated for several energy storage and conversion materials. We further argue that down-scaling of physical device structures based on oxides necessitates ionic and electrochemical effects to be taken into account. Future pathways for ESM development are discussed

Jesse, Stephen↗

Should the Standard Count Be Excluded from Neutron Probe Calibration?

About 6 decades after its introduction, the neutron probe remains one of the most accurate methods for indirect measurement of soil moisture content. Traditionally, the calibration of a neutron probe involves the ratio of the neutron count in the soil to a standard count, which is the neutron count in the fixed environment such as the probe shield or a specially-designed calibration tank. The drawback of this count-ratio-based calibration is that the error in the standard count is carried through to all the measurements. An alternative calibration is to use the neutron counts only, not the ratio, with proper correction for radioactive decay and counting time. To evaluate both approaches, the shield counts of a neutron probe used for three decades were analyzed. The results show that the surrounding conditions have a substantial effect on the standard count. The error in the standard count also impacts the calculation of water storage and could indicate false consistency among replicates. The analysis of the shield counts indicates negligible aging effect of the instrument over a period of 26 years. It is concluded that, by excluding the standard count, the use of the count-based calibration is appropriate and sometimes even better than ratio-based calibration. The count-based calibration is especially useful for historical data when the standard count was questionable or absent

54 ENVIRONMENTAL SCIENCES↗

Assessment of the Group 3-4 (HV-S1, HV-S2, IHLW-S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 3-4 exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The HV-S1, HV-S2, and IHLW-S1 exhaust stacks were tested together as a group (Test Group 3-4) because they share a geometric attribute: the common factor in their design is that the last significant flow disturbance upstream of the air sampling probe is a jog (i.e., two conjoined bends of equal and opposite curvature resulting in a change in elevation of the duct). Federal regulations require that a sampling probe be located in the exhaust stack according to criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

Glissmeyer, John A.↗

Department of Energy Project DE-SC0012198: Probing Electron-Molecule Scattering with HHG: Theory and Experiment (Final Report)

The study of the motion of atoms in molecules is important to understanding many areas of physical and life sciences. Such motion occurs on many different times scales, with electronic motion occurring on a sub-femtosecond time scale, and simple vibrational motion in tens to hundreds of femtoseconds. One way to follow such processes in real time is by the use of shortpulsed lasers, and in particular by studying time-resolved photoionization and the related process of high-harmonic generation (HHG). Thus there has been much effort to develop the tools necessary to probe molecular systems using short pulse lasers and understanding the sensitivity of the different possible probes to the time dependent geometric structure as well as the electronic structure of molecules. Our research has particularly focused on the connection between high-field processes and the more traditional weak field photoionization processes. Strong field and weak field processes can be connected through models that involve the same matrix elements. We have demonstrated in our study of HHG from SF 6 that the spectrum is sensitive to the interplay between the angular dependence of the ionization step and recombination step. In our study of rescattering spectroscopy, we have shown that with a combination of experiment and theory, we can use this high-field spectroscopy to determine molecular structure in molecules such as C 2 H 4 . We have also developed new computational tools based on overset grids to enable studies on larger molecular systems which use much more robust numerical approaches so that the resulting code can be a tool that non-specialists can use to study related systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗