Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Recent Photovoltaic Performance Data in the USA (Presentation)

This paper presents performance data from nearly 50,000 Photovoltaic systems totaling 1.7 Gigawatts installed capacity in the USA from 2009 to 2012. 90% of the systems performed to within 10% or better of expected performance. Only 2-4% of the data indicate issues significantly affecting the system performance. Special causes of underperformance and their impacts are delineated by reliability category. Delays and interconnections dominate project-related issues particularly in the first year, but total less than 0.5% of all systems. Hardware-related issues are dominated by inverter problems totaling less than 0.4% and underperforming modules to less than 0.1%.

14 SOLAR ENERGY↗

Preliminary Findings of the Photovoltaic Cell Calibration Experiment on Pathfinder Flight 95-3

The objective of the photovoltaic (PV) cell calibration experiment for Pathfinder was to develop an experiment compatible with an ultralight UAV to predict the performance of PV cells at AM0, the solar spectrum in space, using the Langley plot technique. The Langley plot is a valuable technique for this purpose and requires accurate measurements of air mass (pressure), cell temperature, solar irradiance, and current-voltage(IV) characteristics with the cells directed normal to the direct ray of the sun. Pathfinder's mission objective (95-3) of 65,000 ft. maximum altitude, is ideal for performing the Langley plot measurements. Miniaturization of electronic data acquisition equipment enabled the design and construction of an accurate and light weight measurement system that meets Pathfinder's low payload weight requirements.

Vargas-Aburto, Carlos↗

Bifacial PV System Mismatch Loss Estimation

Nonuniform rear-irradiance on bifacial PV systems can cause additional mismatch loss, which may not be appropriately captured in PV energy production estimates and software. A simplified empirical relationship is presented that links the spatial variation of irradiance (to the resulting mismatch loss factor).

14 SOLAR ENERGY↗

Secure, Scalable Control and Communications for Distributed PV

An increasing number of jurisdictions are adopting Distributed Energy Resource (DER) interconnection standards which require photovoltaic (PV) inverters, energy storage systems, and other DER to include interoperable grid-support functionality. These functions provide grid operators the nobs to support local and bulk power system operations with DER equipment, but the associated grid operator-to-DER communications networks must be deployed with appropriate cybersecurity features. In some situations, additional security features may prevent control system scalability or increase communication latencies and dropouts. These unintentional consequences of the security features would therefore hinder the ability of the grid operator to implement specific control algorithms. This project evaluated the tradeoffs between power system performance and cybersecurity metrics for several grid services.

14 SOLAR ENERGY↗

Secure Scalable Control and Communications for Distributed PV (Final Technical Report)

An increasing number of jurisdictions are adopting Distributed Energy Resource (DER) interconnection standards which require photovoltaic (PV) inverters, energy storage systems, and other DER to include interoperable grid-support functionality. These functions provide grid operators the nobs to support local and bulk power system operations with DER equipment, but the associated grid operator-to-DER communications networks must be deployed with appropriate cybersecurity features. In some situations, additional security features may prevent control system scalability or increase communication latencies and dropouts. These unintentional consequences of the security features would therefore hinder the ability of the grid operator to implement specific control algorithms. This project evaluated the tradeoffs between power system performance and cybersecurity metrics for several grid services. This was conducted in two parts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Brief: Daily Performance Changes in Metal Halide Perovskite PV Modules

Metal halide perovskite photovoltaic modules deployed outdoors and held at their maximum power point show daily, reversible, relative changes of up to 30% in efficiency between morning and afternoon. Predicting energy yield and quantifying reliability will require properly handling such daily performance changes.

14 SOLAR ENERGY↗

Migration and Distribution of Natural Organic Matter Injected into Subsurface Systems - 16523

The Savannah River Site (SRS) was one of the major U.S. Department of Energy facilities that produced large amounts of radioactive and hazardous waste during the Cold War era, a legacy of material production for defense purposes. The unlined F-Area seepage basins received approximately 1.8 billion gallons of acidic waste solutions containing low-level radioactivity from numerous isotopes generated by uranium slug and irradiated fuel processing. Sufficient quantities of uranium isotopes, I-129, Tc-99, and tritium migrated into the groundwater, creating an acidic plume with a pH between 3 and 5.5. Humic substances (HS) are complex heterogeneous mixtures of poly-dispersed materials formed by biochemical and chemical reactions during the decay and transformation of plant and microbial remains. They are known for their excellent binding capacity for metals, making them a strong candidate for remediation efforts to reduce the mobility of uranium (VI) in the subsurface. Studies showed that HS are an important ion exchange and metal-complexing ligand, carrying a large number of functional groups with high complexing capacity that can greatly affect the mobility behavior of actinides in natural systems. Hence, it is a potential in situ amendment for treating groundwater contaminated with these constituents. Column experiments were conducted to address the complexities of HS in flow-through porous media representative of the acidic aquifer at the SRS F-Area Seepage Basins. The humate source used, Huma-K, is high in humic and fulvic compounds. The column studies were done using the soil obtained from SRS's FAW-1 core-hole at a depth interval of 60'-70'. A bromide tracer test was performed to obtain the pore volume (PV), variance and Peclet number. The columns were saturated with an artificial groundwater solution prepared to mimic the groundwater at SRS that was pH adjusted to 3.5 and 5 until the effluent pH reached equilibrium. Approximately one (1) PV of 5000 ppm of Huma-K was injected into the columns at 2 ml/min to study the sorption of Huma-K on the sediment. Desorption of Huma-K was studied by injecting approximately four (4) PVs of the pH adjusted artificial groundwater solution. A faster increase in pH was observed in column 1 (saturated with pH 3.5 AGW) compared to column 2 (saturated with pH 5 AGW). After injection of 2 PV of AGW, the pH of the columns reached 6.5 and 7, respectively, for columns 1 and 2. After injecting an additional PV of AGW, the pH remained relatively stable. With an increase in pH from 3.5 to 5.0, the overall retention of HA increased from 461 mg/kg for the column with pH 3.5 to 642 mg/kg for the column with pH 5. This suggests that retention is not due to adsorption alone, but adsorption coupled with precipitation and re-dissolution of Huma-K as it flows through the columns is a possible explanation for greater retention at pH 5. This negates the use of a simple Langmuir isotherm to explain humate behavior in the acidic environment of column 1. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photovoltaic Degradation Rates -- An Analytical Review

As photovoltaic penetration of the power grid increases, accurate predictions of return on investment require accurate prediction of decreased power output over time. Degradation rates must be known in order to predict power delivery. This article reviews degradation rates of flat-plate terrestrial modules and systems reported in published literature from field testing throughout the last 40years. Nearly 2000 degradation rates, measured on individual modules or entire systems, have been assembled from the literature, showing a median value of 0.5%/year. The review consists of three parts: a brief historical outline, an analytical summary of degradation rates, and a detailed bibliography partitioned by technology.

14 SOLAR ENERGY↗

Nondestructive Examination Guidance for Dry Storage Casks

In this report, an assessment of NDE methods is performed for components of NUHOMS 80 and 102 dry storage system components in an effort to assist NRC staff with review of license renewal applications. The report considers concrete components associated with the horizontal storage modules (HSMs) as well as metal components in the HSMs. In addition, the report considers the dry shielded canister (DSC). Scope is limited to NDE methods that are considered most likely to be proposed by licensees. The document, ACI 349.3R, Evaluation of Existing Nuclear Safety-Related Concrete Structures, is used as the basis for the majority of the NDE methods summarized for inspecting HSM concrete components. Two other documents, ACI 228.2R, Nondestructive Test Methods for Evaluation of Concrete in Structures, and ORNL/TM-2007/191, Inspection of Nuclear Power Plant Structure--Overview of Methods and Related Application, supplement the list with additional technologies that are considered applicable. For the canister, the ASME B&PV Code is used as the basis for NDE methods considered, along with currently funded efforts through industry (Electric Power Research Institute [EPRI]) and the U.S. Department of Energy (DOE) to develop inspection technologies for canisters. The report provides a description of HSM and DSC components with a focus on those aspects of design considered relevant to inspection. This is followed by a brief description of other concrete structural components such as bridge decks, dams, and reactor containment structures in an effort to facilitate comparison between these structures and HSM concrete components and infer which NDE methods may work best for certain HSM concrete components based on experience with these other structures. Brief overviews of the NDE methods are provided with a focus on issues and influencing factors that may impact implementation or performance. An analysis is performed to determine which NDE methods are most applicable to specific components.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data-Driven Day-Ahead PV Estimation Using Hybrid Deep Learning

Ongoing smart grid activities and associated automation resulted in rich set of data. Here, these data can be utilized for monitoring and estimation of real time photovoltaic (PV) generation. Inherent variability in PV and related impact on power systems is a challenging problem. Improving the accuracy of PV generation estimation is beneficial for both the PV owners and the grid operators. Recently, deep learning algorithms possible by the availability of data have shown its advantages for time series estimation; however, its application on PV generation estimation is still in the early stage. In this paper, a hybrid estimation model with a combination of long-short-term-memory network (LSTM) and persistence model (PM) is developed to provide day-ahead PV estimation at 15-minute time interval with high accuracy and robustness. Simulation results show the superior performance of the proposed method over existing methods for most of the test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible Geothermal Power Generation utilizing Geologic Thermal Energy Storage (Final Seedling Project Report)

This report concludes that there is a cost-effective strategy for seasonal storage of heat that will provide firm, but dispatchable, electrical generating capacity in times when other renewable energy is not available to meet demand. Deployment of the technology appears to require no new technology, but instead combines solar, geothermal, and conventional oil and gas drilling technologies in a novel way. The study basis is the use of sedimentary geologic formations as a medium for thermal energy storage (TES), specifically for heat collected in concentrating solar collectors. The study identifies methodologies that could be used to transport this heat into and out of the subsurface in order to produce dispatchable electrical power, and reports on initial optimization results. The GeoTES system (heat input, storage, heat recovery, and heat to electric conversion) described in this analysis has the potential to provide a unique pathway for increasing the grid penetration of renewable energy in large blocks of power and across many states and regions. Further, the system can be used both to meet the nation’s flexible energy needs while also improving grid stability and reliability. The present study evaluated the use of a large number of dedicated wells to store and recover the heat, essentially creating a synthetic geothermal reservoir. The use of sedimentary geology allows the wells to be drilled at low cost. Dedicated hot and cold wells are used, arranged in a five-spot well pattern with each hot or cold well surrounded at an appropriate distance by the opposite type of well. In large numbers this becomes alternating rows of hot and cold wells. Each hot and cold well is operated using a push-pull strategy. This configuration provides the ability to immediately recover stored hot fluid from a GeoTES reservoir, or to store the heat over many months for recovery at low loss when needed. This is a practical approach for managing the system’s fluid inventory and reducing parasitic load. The production and injection power requirements are reduced because the rows of wells operating in “push” mode provide help to the wells operating in “pull” mode, and vice-versa. Initial charging of a GeoTES system increases the heat recovery temperature. Increasing the duration of the charging period decreases the magnitude of the temperature fluctuations that occur following prolonged system operation. Because of direct contact of the heated water with the reservoir formation, the production of both hot water and steam from the TES, and the temperature ranges of the recovered fluid (190 – 230°C or 375 – 445°F), conventional geothermal power cycles were used to convert the stored heat to electricity. A power cycle configuration for the GeoTES system was selected following a screening study of a number of flash, and flash/binary hybrid options. This analysis concluded that, of the configurations evaluated, a dual-stage flash steam cycle provides the lowest capital costs per unit net power generation with an acceptable hot brine inlet fluid flow rate. The evaluation included the power plant cost estimate, the cost and number of wells and the associated parasitic loads. Annual power generation performance was simulated to evaluate capacity factor and LCOE. The LCOE calculated for the inherently high capacity GeoTES system was $\$$0.13/kWhe. This value was calculated for the case where the solar thermal collector was sized in such a way that the solar collectors permitted an annual power plant capacity factor of up to 97%. The power cycle was able to provide power to the grid every night of the year, and flexible base-load power during the winter, if needed. This LCOE value compares favorably with reported values for solar photovoltaic plus battery energy storage (PV+BES) systems in the open literature, i.e. $\$$0.148/kWhe for a PV+BES system with 4 hours of electrochemical battery energy storage capacity. Addition of battery energy storage with more hours of storage would further increase PV+BES system LCOE and increase the separation between GeoTES and PV+BES. A GeoTES system would therefore provide superior economics for high capacity and long duration solar energy storage.

14 SOLAR ENERGY↗

Experimental Technetium Release from Simulated Salt-stone Cementitious Waste Form - 18419

Experiments are being conducted to evaluate the early release of technetium (Tc) from fresh salt-stone waste forms using dynamic flow-through tests. Salt-stone is a chemically reducing, grout-based waste form used by the U.S. Department of Energy (DOE) to dispose of low-activity salt solutions arising from high-level radioactive waste tank closure activities at the Savannah River Site (SRS). A key safety function of salt-stone is maintaining a low-flow, chemically reducing environment that will attenuate the release of redox-sensitive radioelements such as Tc. Salt-stone also provides a physical barrier due to its low intrinsic permeability, which limits both water and oxygen ingress. These release experiments, conducted to support the U.S. Nuclear Regulatory Commission's monitoring role during tank closure, are designed to provide independent information on how well salt-stone will perform its safety function. The dynamic leach tests were conducted in a Hassler-type core-holder permeameter system that allows an accelerated flow rate of simulated SRS groundwater through an intact cylinder of salt-stone spiked with Tc-99 at a concentration of approximately 2,100 Bq/g (3 ppm). The first salt-stone specimen to be tested (Specimen 2) was prepared with Grade 100 ground granulated blast-furnace slag and aged for 119 days in a temperature-controlled, low-oxygen, high-humidity environment. Before test completion, 9.5 pore volumes (PV) of simulated SRS groundwater were passed through the salt-stone cylinder. After a few PV, apparent saturated hydraulic conductivity (K{sub sat}) values calculated from flow data reached a steady-state value of approximately 1.0 x 10{sup -9} cm/s, which is within the range of previously reported data. Tc-99 concentrations in leachate peaked early during the leach test at 2.0 x 10{sup -7} M and then declined to approximately 4 x 10{sup -8} M after 9.5 PV. The leachate Tc-99 concentration after elution of 9.5 PV is broadly consistent with a Tc solution concentration controlled by the solubility of reduced Tc solids. The range of Tc-99 concentrations is similar to the range reported for a column test that was sponsored by DOE, but the time pattern of release differs. The second salt-stone specimen tested (Specimen 3) was aged for 372 days and it further differed from the first specimen in that its Grade 100 slag component had been finely ground using a mortar and pestle in an attempt to make it more reactive. This second test yielded Tc release behavior broadly similar to that observed during the first test, except that the early Tc peak (at 1.2 x 10{sup -6} M) was six times higher and the concentration after 6.7 PV (8.8 x 10{sup -8} M) was approximately two times higher than in the first test. In addition, the steady-state K{sub sat} was an order of magnitude lower than that of the first specimen. During the second test, the injection pump was intentionally turned off for a period of 11 days (i.e., approximate residence time for 1 PV) and a Tc spike was observed when pumping resumed, suggesting that longer residence times may promote higher Tc effluent concentrations. During a second intentional shut-down of the pump for 25 days (approximate residence time for 2 PV), another Tc spike was observed. An unplanned excursion to higher confining pressure physically affected the specimen, temporarily lowering the apparent K{sub sat} followed by a subsequent increase in both K{sub sat} and Tc effluent concentration. One hypothesis is that the transient spike in confining pressure and resulting salt-stone compression and later decompression may have induced Tc release from otherwise inactive pores. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the Path to SunShot. Advancing Concentrating Solar Power Technology, Performance, and Dispatchability

This report examines the remaining challenges to achieving the competitive concentrating solar power (CSP) costs and large-scale deployment envisioned under the U.S. Department of Energy's SunShot Initiative. Although CSP costs continue to decline toward SunShot targets, CSP acceptance and deployment have been hindered by inexpensive photovoltaics (PV). However, a recent analysis found that thermal energy storage (TES) could increase CSP's value--based on combined operational and capacity benefits--by up to 6 cents/kWh compared to variable-generation PV, under a 40% renewable portfolio standard in California. Thus, the high grid value of CSP-TES must be considered when evaluating renewable energy options. An assessment of net system cost accounts for the difference between the costs of adding new generation and the avoided cost from displacing other resources providing the same level of energy and reliability. The net system costs of several CSP configurations are compared with the net system costs of conventional natural-gas-fired combustion-turbine (CT) and combined-cycle plants. At today's low natural gas prices and carbon emission costs, the economics suggest a peaking configuration for CSP. However, with high natural gas prices and emission costs, each of the CSP configurations compares favorably against the conventional alternatives, and systems with intermediate to high capacity factors become the preferred alternatives. Another analysis compares net system costs for three configurations of CSP versus PV with batteries and PV with CTs. Under current technology costs, the least-expensive option is a combination of PV and CTs. However, under future cost assumptions, the optimal configuration of CSP becomes the most cost-effective option.

14 SOLAR ENERGY↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Considerations for AMI-Based Operations for Distribution Feeders

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DCFC + Hydrogen Station Design Optimization [Slides]

Both direct current fast charging (DCFC) and Hydrogen stations are working to create successful long-term business models; however, analyses for DCFC and hydrogen fueling infrastructure are almost always performed separately. This work provides a detailed exploration of the benefit of integrating DCFC and hydrogen stations to lower the total system cost from load balancing and equipment cost sharing. To achieve this we have adapted the REopt optimization framework to simultaneously optimize the design and operation of integrated DCFC and H2 fueling station. Results indicate that 1) combining hydrogen fueling and DCFC stations can significantly reduce lifetime costs compared to separated stations. 2) Co-location with additional site load reduces DCFC costs, however, integration of DCFC with hydrogen provides an even greater cost reduction. 3) Adding PV to combined stations further reduces the lifetime station cost. 4) Capital investments in station combination today can help reduce the cost of operating DCFC tomorrow and 5) product diversification acts as a hedge against variability and enables a more dynamic response to market changes.

08 HYDROGEN↗

Flat-plate module efficiency versus cost tradeoffs

The Five Year Research Plan energy cost methodology and in depth analyses based on the extensive data that are relevant to PV systems are used to facilitate the accomplishment of the $0.15/kWh energy cost goal. An equation is given for the five year energy cost methodology. The allocation guidelines are designed to be consistent with flat solar array (FSA) milestones for module cost, module efficiency, and the programmatic goal for energy cost. They are research targets that appear to be achievable, given prior accomplishments and planned activities in the areas of low cost silicon purification, low cost sheet material, high efficiency cell processing, low cost, long life encapsulants, and automated fabrication method. Extensive sensitivity analysis work has been performed that shows that these guidelines represent an efficient way to meet the intent of the DOE program.

Aster, R. W.↗

Considerations for AMI-Based Operations for Distribution Feeders: Preprint

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗