Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA ELECTRODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Indirect Magnetic Measurements on the Aerodynamic Heating Facility (AHF)

The arc jet complex at NASA Ames Research Center (ARC) investigates various thermal protection systems (TPS) and their performance in high enthalpy flow environments to improve heat shields used in atmospheric entry. The arc jet operates by inducing an arc between two electrodes and passing the heated gas through a supersonic nozzle. The arc plasma is typically a partially ionized air mixture at low temperature (< 2 eV) but operates for long periods of time (up to 30 min) at high power (< 60 MW). However, simulations using the in-house ARC Heater Simulator (ARCHeS) code predict that the arc is still unstable to MHD instabilities, primarily the kink instability, which limit the operational envelope of the facility [1]. Consequently, it is important to better characterize these instabilities to improve facility stability and extend operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) arc diagnostics must be non-invasive (i.e., optical or magnetic). This work will cover the development of tri-axial magnetic hall sensors for arc jet instabilities and subsequent 3D characterization of arc motion. The latest results describing the kink instability amplitude, frequency and wavelength will be presented and represent the first measurements of this instability in a NASA arc jet facility. References: [1] Meurisse, J. (2018). 3D Unsteady Model of Arc Heater Plasma Flow Using the ARC Heater Simulator (ARCHeS), APS Gaseous Electronics Conference, 2018: APS.

Sebastian Vicente Colom↗

Device for generation of pulsed corona discharge

The invention is a method and system for the generation of high voltage, pulsed, periodic corona discharges capable of being used in the presence of conductive liquid droplets. The method and system can be used, for example, in different devices for cleaning of gaseous or liquid media using pulsed corona discharge. Specially designed electrodes and an inductor increase the efficiency of the system, permit the plasma chemical oxidation of detrimental impurities, and increase the range of stable discharge operations in the presence of droplets of water or other conductive liquids in the discharge chamber.

47 OTHER INSTRUMENTATION↗

Non-Maxwellian to Maxwellian transitions of atmospheric microplasmas at microwave frequencies

Particle-in-cell/Monte Carlo simulations and numerical analysis of a single particle motion are performed for atmospheric He microplasmas at microwave frequencies to determine the characteristics of non-Maxwellian to Maxwellian transition. The left and the right regimes of Paschen curve, divided by this transition, reveal that the transition frequencies depend on the gap of electrodes and the neutral gas pressure to follow scaling laws for a new extended Paschen law. The fluid models are reasonable at the right-side regime of Paschen breakdown areas, but not on the left side, which is highly kinetic for electrons. The plasmas driven by weaker electric fields of high enough frequencies at the right-side Paschen regime breed more energetic electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current collection in a magnetoplasma

The authors present a survey of a very incomplete subject, current collection in a magnetoplasma. The best-developed and simplest theories for current collection are steady-state collisionless theories, and these must be understood before departures from them can be analyzed usefully. Thus, the authors begin with a review of them. The authors include some recent numerical results which indicate that steady-state collisionless Laplace-limit currents remain substantially below the Parker-Murphy (1967) canonical upper bound out to very large electrode potentials, and approach it as a limit only very slowly if at all. Attempts to correct this theory for space-charge effects lead to potential disturbances which extend to infinite distance along the electrode's magnetic shadow, unless collisional effects are also taken into account. However, even a small amount of relative plasma drift motion, such as that involved in a typical rocket experiment, can change this conclusion fundamentally. It is widely believed that time-averaged current collection may be increased by effects of plasma turbulence, and the authors review the available evidence for and against this contention. Steady-state collisionless particle dynamics predicts the existence of a toroidal region of trapped orbits which surrounds the electrode. Light emissions from this region have been photographed, indicating that collisional ionization may also occur there, and this, and/or scattering by collisions or possibly turbulent fluctuations in this region, may also increase current collection by the electrode. The authors also discuss effects on particle motions near the electrode, associated with breakdown of magnetic insulation in the region of large electric fields near it.

Laframboise, Jim G.↗

Direct synthesis of nanostructured V2O5 films using solution plasma spray approach for lithium battery application

We demonstrate for the first time, the synthesis of vanadium pentoxide (V{sub 2}O{sub 5}) nanoparticles and nanorods in the films using a high throughput solution plasma spray deposition approach. The scalable plasma spray method enables the direct deposition of large area nanostructured films of V{sub 2}O{sub 5} with controllable particle size and morphology. In this approach, the solution precursors (vanadium oxychloride and ammonium metavanadate) were injected externally into the plasma jet, which atomizes and pyrolyzes the precursors in-flight, resulting in the desired films on the current collectors. The microstructure analysis of the as synthesized films revealed pure nanocrystalline phase for V{sub 2}O{sub 5} with particles in the size range of 20-50 nm. The V{sub 2}O{sub 5} film based electrodes showed stable reversible discharge capacity in the range of 200-250 mAh g{sup -1} when cycled in the voltage window 2-4 V. We further discuss the mechanism for controlling the particle growth and morphology, and also the optimization of reversible lithium storage capacity. The nanorods of V{sub 2}O{sub 5} formed after the anneal treatment also show reversible storage capacity indicative of the potential use of such film based electrodes for energy storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experiment and Results on Plasma Etching of SRF cavities

The inner surfaces of SRF cavities are currently chemically treated (etched or electropolished) to achieve the state of the art RF performance. We designed an apparatus and developed a method for plasma etching of the inner surface for SRF cavities. The process parameters (pressure, power, gas concentration, diameter and shape of the inner electrode, temperature and positive dc bias at inner electrode) are optimized for cylindrical geometry. The etch rate non-uniformity has been overcome by simultaneous translation of the gas point-of-entry and the inner electrode during the processing. A single cell SRF cavity has been centrifugally barrel polished, chemically etched and RF tested to establish a baseline performance. This cavity is plasma etched and RF tested afterwards. The effect of plasma etching on the RF performance of this cavity will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Point-like pulse-periodic UV radiation source with a short pulse duration

The radiation of discharge plasma was investigated in the nanosecond breakdown of short interelectrode gaps in a nonuniform electric field. Voltage pulses with an incident wave amplitude of {approx}10 kV, a FWHM duration of {approx}1 ns, and a rise time of {approx}200 ps were used. X-ray radiation from the discharge gap was recorded for an interelectrode gap of 0.5 mm, which confirms the generation of runaway electrons in the discharge formation. In the pulse-periodic air breakdown of a 0.5-mm wide gap at atmospheric pressure, the lines of electrode materials and the continuum were shown to make the main contribution to the plasma emission; the highest radiation intensity fell on the 200 - 300 nm region, which accounted for {approx}40% of the total emission energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved imaging of electrical discharge development in underwater bubbles

The formation and development of plasma in single air bubbles submerged in water were investigated. The difference in the discharge dynamics and the after-effects on the bubble were investigated using a 900 000 frame per second high-speed charge-coupled device camera. It was observed that depending on the position of the electrodes, the breakdown could be categorized into two modes: (1) direct discharge mode, where the high voltage and ground electrodes were in contact with the bubble, and the streamer would follow the shortest path and propagate along the axis of the bubble and (2) dielectric barrier mode, where the ground electrode was not in touch with the bubble surface, and the streamer would form along the inner surface of the bubble. The oscillation of the bubble and the development of instabilities on the bubble surface were also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Picosecond X-ray streak camera dynamic range measurement

Streak cameras are widely used to record the spatio-temporal evolution of laser-induced plasma. A prototype of picosecond X-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to answer the Laser MegaJoule specific needs. The dynamic range of this instrument is measured with picosecond X-ray pulses generated by the interaction of a laser beam and a copper target. The required value of 100 is reached only in the configurations combining the slowest sweeping speed and optimization of the streak tube electron throughput by an appropriate choice of high voltages applied to its electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Slope and amplitude asymmetry effects on low frequency capacitively coupled carbon tetrafluoride plasmas

We report investigations of capacitively coupled carbon tetrafluoride (CF{sub 4}) plasmas excited with tailored voltage waveforms containing up to five harmonics of a base frequency of 5.5 MHz. The impact of both the slope asymmetry, and the amplitude asymmetry, of these waveforms on the discharge is examined by combining experiments with particle-in-cell simulations. For all conditions studied herein, the discharge is shown to operate in the drift-ambipolar mode, where a comparatively large electric field in the plasma bulk (outside the sheaths) is the main mechanism for electron power absorption leading to ionization. We show that both types of waveform asymmetries strongly influence the ion energy at the electrodes, with the particularity of having the highest ion flux on the electrode where the lowest ion energy is observed. Even at the comparatively high pressure (600 mTorr) and low fundamental frequency of 5.5 MHz used here, tailoring the voltage waveforms is shown to efficiently create an asymmetry of both the ion energy and the ion flux in geometrically symmetric reactors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vitrification of High-Cr Glass in Research-Scale Melter

This test report describes the experimental results from a small-scale test using the research-scale melter (RSM) at Pacific Northwest National Laboratory to demonstrate processing of a high-Cr simulated feed stream, designated HLW-HCr-16. The RSM is a small, joule-heated melter capable of processing melter feed continuously. The melter is equipped with Inconel ® 693 electrodes, Monofrax ® K-3 refractory, and an Inconel 690 pour spout. An electric kiln surrounds the melter body and minimizes heat loss from the melter body during operation. The RSM is equipped with an offgas treatment system that employs quenching, wet scrubbing, and high-efficiency mist elimination. The glass-discharge section is heated to facilitate pouring of the glass. The melter is fitted with a melt cavity that is ~25 cm (10 in.) in diameter with a nominal glass depth of 8.9 cm (3.5 in.). The melter was operated with a target glass temperature of 1150°C and target plenum temperature between 550°C and 700°C for this test. The air bubbling rate was 4.2 L/min. Overall, during the continuous operation of the melter for ~ 103 hours, ~ 141 kg of glass was produced. At the conclusion of the test, the melter and exhaust lines were visually inspected for particulate deposition and corrosion. Entrained material had adhered to the underside of the melter lid and to the exhaust piping. Enrichments in elements such as Cl, F, B, K, Li, P, Na, and S were measured in these deposits through inductively coupled plasma–optical emission spectroscopy and X-ray fluorescence analysis. When the melter electrodes and air bubbler tube were removed from the glass in the RSM, the electrodes appeared discolored, but no significant loss of metal was observed. The processing of a high-Cr simulant, HLW-HCr-16, in the RSM produced glass at an average rate of 1.36 kg/h, equaling a melter-surface-area normalized glass generation rate of 654 kg/day/m 2 . The resulting glass met the toxicity characteristic leaching procedure requirement. Test results of crystallinity, electrical conductivity, and viscosity showed good processing properties of this high-Cr high-level waste glass. RSM offgas was also sampled and analyzed at periodic intervals during steady-state operating conditions. The total decontamination factor averaged by four sampling periods was 134. The concentrations of CO and NO x in emissions were 237 to 422 and 69 to 94 parts per million by volume, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A highly miniaturized electron and ion energy spectrometer prototype for the rapid analysis of space plasmas

MEMS (Micro Electro-Mechanical Systems) plasma analyzers are a promising possibility for future space missions but conventional instrument designs are not necessarily well suited to micro-fabrication. Here, a candidate design for a MEMS-based instrument has been prototyped using electron-discharge machining. The device features 10 electrostatic analyzers that, with a single voltage applied to it, allow five different energies of electron and five different energies of positive ion to be simultaneously sampled. It has been simulated using SIMION and the electron response characteristics tested in an instrument calibration chamber. Small deviations found in the electrode spacing of the as-built prototype were found to have some effect on the electron response characteristics but do not significantly impede its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of ionization processes in high-pressure nitrogen, air, and SF{sub 6} during a subnanosecond breakdown initiated by runaway electrons

The dynamics of ionization processes in high-pressure nitrogen, air, and SF{sub 6} during breakdown of a gap with a nonuniform distribution of the electric field by nanosecond high-voltage pulses was studied experimentally. Measurements of the amplitude and temporal characteristics of a diffuse discharge and its radiation with a subnanosecond time resolution have shown that, at any polarity of the electrode with a small curvature radius, breakdown of the gap occurs via two ionization waves, the first of which is initiated by runaway electrons. For a voltage pulse with an ∼500-ps front, UV radiation from different zones of a diffuse discharge is measured with a subnanosecond time resolution. It is shown that the propagation velocity of the first ionization wave increases after its front has passed one-half of the gap, as well as when the pressure in the discharge chamber is reduced and/or when SF{sub 6} is replaced with air or nitrogen. It is found that, at nitrogen pressures of 0.4 and 0.7 MPa and the positive polarity of the high-voltage electrode with a small curvature radius, the ionization wave forms with a larger (∼30 ps) time delay with respect to applying the voltage pulse to the gap than at the negative polarity. The velocity of the second ionization wave propagating from the plane electrode is measured. In a discharge in nitrogen at a pressure of 0.7 MPa, this velocity is found to be ∼10 cm/ns. It is shown that, as the nitrogen pressure increases to 0.7 MPa, the propagation velocity of the front of the first ionization wave at the positive polarity of the electrode with a small curvature radius becomes lower than that at the negative polarity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conditions and growth rate of Rayleigh instability in a Hall thruster under the effect of ion temperature

Rayleigh instability is investigated in a Hall thruster under the effect of finite temperature and density gradient of the plasma species. The instability occurs only when the frequency of the oscillations {omega} falls within a frequency band described by k{sub y}u{sub 0}+(1/k{sub y})({partial_derivative}{sup 2}u{sub 0}/{partial_derivative}x{sup 2})+({Omega}/k{sub y}n{sub 0})({partial_derivative}n{sub 0}/{partial_derivative}x)<<{omega}<{radical}((Y{sub i}T{sub i}k{sub y}{sup 2}/M)+({omega}{sub pi}{sup 2}({Omega}{sup 2}+Y{sub e}T{sub e}k{sub y}{sup 2}/Y{sub e} T{sub e}k{sub y}{sup 2}mm)/({omega}{sub pe}{sup 2}+{Omega}{sup 2}+Y{sub e}T{sub e}k{sub y}{sup 2}/Y{sub e}T{sub e}k{sub y}{sup 2}mm))), where u{sub 0} is the drift velocity of the electrons, {Omega} is their gyration frequency under the effect of the magnetic field, k{sub y} is the wave propagation constant, n{sub 0} is the plasma density together with {partial_derivative}n{sub 0}/{partial_derivative}n{sub 0}{partial_derivative}x{partial_derivative}x as the density gradient, and T{sub i}(T{sub e}), M(m), Y{sub i}(Y{sub e}), and {omega}{sub pi}({omega}{sub pe}) are the temperature, mass, specific heat ratio, and plasma frequency of the ions (electrons), respectively. A relevant Rayleigh equation is derived and solved numerically using the fourth-order Runge-Kutta method for investigating the perturbed potential under the effect of electron drift velocity, channel length, magnetic field, ion temperature, and electron temperature. The instability grows faster because of the magnetic field, ion temperature, and drift velocity of the electrons but its growth rate is reduced because of the electron temperature, channel length, and also its far distances from the anode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of diagnostic and manipulation systems for space-charge dominated electron beams and confined electron plasmas in ELTRAP

Modifications have been implemented in the Penning-Malmberg device ELTRAP aimed at performing studies on the dynamics of space-charge dominated nanosecond electron bunches traveling along the magnetic field. In particular, a Thomson backscattering apparatus has been developed where an infrared (IR) laser pulse collides with the bunched electron beam. The frequency-shifted backscattered radiation, acquired by means of a photomultiplier (PMT), can be exploited to evaluate information on energy, energy spread and density of the bunch. The achievable sensitivity of the diagnostics has been estimated, and valuable information on the main parameters affecting the signal-to-noise (S/N) ratio has been obtained [B. Paroli, F. Cavaliere, M. Cavenago, F. De Luca, M. Ikram, G. Maero, C. Marini, R. Pozzoli, and M. Rome, JINST 7, P01008 (2012)]. A series of upgrades are under way, aimed at increasing the S/N ratio through the use of a new laser for the electron source, the insertion of a stray light shield, and the optimization of the detection electronics. Moreover, electromagnetic simulations relevant to the design and implementation of a microwave heating system are presented. The generation of an electron plasma in ELTRAP by means of a low-power radio frequency (RF) drive in the MHz range applied on one of the trap electrodes and under ultra-high vacuum (UHV) conditions has previously been demonstrated [B. Paroli, F. De Luca, G. Maero, F. Pozzoli, and M. Rome, Plasma Sources Sci. Technol. 19, 045013 (2010)]. The new heating system will allow the extension of the RF studies to the GHz range and in particular the production of a more energetic electron plasma via cyclotron resonant excitation.

43 PARTICLE ACCELERATORS↗

Modeling of current characteristics of segmented Langmuir probe on DEMETER

We model the current characteristics of the DEMETER Segmented Langmuir probe (SLP). The probe is used to measure electron density and temperature in the ionosphere at an altitude of approximately 700 km. It is also used to measure the plasma flow velocity in the satellite frame of reference. The probe is partitioned into seven collectors: six electrically insulated spherical segments and a guard electrode (the rest of the sphere and the small post). Comparisons are made between the predictions of the model and DEMETER measurements for actual ionospheric plasma conditions encountered along the satellite orbit. Segment characteristics are computed numerically with PTetra, a three-dimensional particle in cell simulation code. In PTetra, space is discretized with an unstructured tetrahedral mesh, thus, enabling a good representation of the probe geometry. The model also accounts for several physical effects of importance in the interaction of spacecraft with the space environment. These include satellite charging, photoelectron, and secondary electron emissions. The model is electrostatic, but it accounts for the presence of a uniform background magnetic field. PTetra simulation results show different characteristics for the different probe segments. The current collected by each segment depends on its orientation with respect to the ram direction, the plasma composition, the magnitude, and the orientation of the magnetic field. It is observed that the presence of light H{sup +} ions leads to a significant increase in the ion current branch of the I-V curves of the negatively polarized SLP. The effect of the magnetic field is demonstrated by varying its magnitude and direction with respect to the reference magnetic field. It is found that the magnetic field appreciably affects the electron current branch of the I-V curves of certain segments on the SLP, whereas the ion current branch remains almost unaffected. PTetra simulations are validated by comparing the computed characteristics and their angular anisotropy with the DEMETER measurements, as simulation results are found to be in good agreement with the measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Langmuir Probe Measurements in an Inductively Coupled Ar/CF4 Plasmas

Technological advancement in the microelectronics industry requires an understanding of the physical and chemical processes occurring in plasmas of fluorocarbon gases, such as carbon tetrafluoride (CF4) which is commonly used as an etchant, and their mixtures to optimize various operating parameters. In this paper we report data on electron number density (ne), electron temperature'(Te), electron energy distribution function (EEDF), mean electron energy, ion number density (ni), and plasma potential (Vp) measured by using Langmuir probe in an inductively coupled 13.56 MHz radio frequency plasmas generated in 50%Ar:50%CF4 mixture in the GEC cell. The probe data were recorded at various radial positions providing radial profiles of these plasma parameters at 10-50 mTorr pressures and 200 W and 300 W of RF power. Present measurements indicate that the electron and ion number densities increase with increase in pressure and power. Whereas the plasma potential and electron temperature decrease with increase in pressure, and they weakly depend on RF power. The radial profiles exhibit that the electron and ion number densities and the plasma potential peak at the center of the plasma with an exponential fall away from it, while the electron temperature has a minimum at the center and it increases steadily towards the electrode edge. The EEDFs have a characteristic drop near the low energy end at all pressures and pressures and their shapes represent non-Maxwellian plasma and exhibit more like Druyvesteyn energy distribution.v

Rao, M. V. V. S.↗

Experimental and numerical investigations of the phase-shift effect in capacitively coupled discharges

The phase-shift effect has been investigated by a Langmuir probe and a fluid model in Ar capacitively coupled plasmas at 50 mTorr. In the discharge, two sources with the same frequency, i.e., 27.12 MHz, are applied on the top and bottom electrodes simultaneously, and the phase shift between them varies from 0 to π. It is found that the electron density has an off-axis peak near the radial edge when the phase difference is equal to 0 due to the electrostatic edge effect, and the best radial uniformity is observed at a phase difference equal to π. Furthermore, when the voltage increases, the best radial uniformity is obtained at lower phase shift values. Moreover, the electron energy probability function has a bi-temperature structure at all the selected phase differences at r = 1–15 cm. The evolution of the plasma characteristics with the phase difference implies that the best radial uniformity can be obtained, by balancing the electrostatic edge effect and the phase shift effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗