Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Icy Moon Project (Final Report)

For this Icy Moon project, we designed, procured, built, tested and used a compact ICI instrument. This instrument has several technical advances, including a compact form factor that uses fiber arrays to relay light to six APDs. This enables a single data acquisition to measure eleven unique baselines simultaneously. The DAQ is well-synchronized and provides a path forward to even more channels. The combination of a bright LED, a sinusoidal target and cylindrical optics enables high-SNR measurements based on a known formula: a 25-ms measurement should have an SNR of 188 on the baseline zero signal. This rapid measurement time should enable two-dimensional operation and obviate the impact of temperature drifts. However, the experiment did not detect a coherence signal on any baseline (see Section Single-shot measurement results).

47 OTHER INSTRUMENTATION↗

VERDI: VERsatile DIffractometer with wide-angle polarization analysis for magnetic structure studies in powders and single crystals

The VERsatile DIffractometer will set a new standard for a world-class magnetic diffractometer with versatility for both powder and single crystal samples and capability for wide-angle polarization analysis. The instrument will utilize a large single-frame bandwidth and will offer high-resolution at low momentum transfers and excellent signal-to-noise ratio. A horizontal elliptical mirror concept with interchangeable guide pieces will provide high flexibility in beam divergence to allow for a high-resolution powder mode, a high-intensity single crystal mode, and a polarized beam option. A major science focus will be quantum materials that exhibit emergent properties arising from collective effects in condensed matter. The unique use of polarized neutrons to isolate the magnetic signature will provide optimal experimental input to state-of-the-art modeling approaches to access detailed insight into local magnetic ordering.

36 MATERIALS SCIENCE↗

Laser-Plasma Spectroscopy of Hydroxyl with Applications

This article discusses laser-induced laboratory-air plasma measurements and analysis of hydroxyl (OH) ultraviolet spectra. The computations of the OH spectra utilize line strength data that were developed previously and that are now communicated for the first time. The line strengths have been utilized extensively in interpretation of recorded molecular emission spectra and have been well-tested in laser-induced fluorescence applications for the purpose of temperature inferences from recorded data. Moreover, new experiments with Q-switched laser pulses illustrate occurrence of molecular recombination spectra for time delays of the order of several dozen of microseconds after plasma initiation. The OH signals occur due to the natural humidity in laboratory air. Centrifugal stretching of the Franck-Condon factors and r-centroids are included in the process of determining the line strengths that are communicated as a Supplementary File. Laser spectroscopy applications of detailed OH computations include laser-induced plasma and combustion analyses, to name but two applications. This work also includes literature references that address various diagnosis applications.

47 OTHER INSTRUMENTATION↗

SCOPE: Spectral cloud optical property estimation using real-time GOES-R longwave imagery

The output of ground-based, solar power generation systems is strongly dependent on cloud cover, which is the main contributor to solar power variability and uncertainty. Cloud optical properties are typically over-simplified in forecasting applications due to the lack of realtime, accurate estimates. In this work, we introduce a method, the Spectral Cloud Optical Property Estimation (SCOPE), for estimating cloud optical properties directly from high-resolution (5-min, 2 km) imagery from Geostationary Operational Environmental Satellite (GOES)-R, which is the newest generation of the GOES system. The SCOPE method couples a two-stream, spectrally resolved radiative model with the longwave GOES-R sensor output to simultaneously estimate the cloud optical depth, cloud top height, and cloud thickness during both day and night at 5-min intervals. The accuracy of SCOPE is evaluated using one year (2018) of downwelling longwave (DLW) radiation measurements from the Surface Radiation Budget Network, which consists of seven sites spread across climatically diverse regions of the contiguous United States. During daytime clear-sky periods, SCOPE predicts DLW within instrument uncertainty (10 W m -2 ) for four of the seven locations, with the remaining locations yielding errors of the order of 11.2, 17.7, and 20.2 W m -2 . For daytime cloudy-sky, daytime all-sky (clear or cloudy), and nighttime all-sky periods, SCOPE achieves root mean square error values of 23.0–34.5 W m -2 for all seven locations. These results, together with the low-latency of the method (1 s per sample), show that SCOPE provides a viable solution to real-time, accurate estimation of cloud optical properties for both day and night.

42 ENGINEERING↗

Testing the 10 spectrograph units for DESI: approach and results

The recently commissioned Dark Energy Spectroscopic Instrument (DESI) will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sqdeg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope delivers light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. A consortium of Aix-Marseille University (AMU) and CNRS laboratories (LAM, OHP and CPPM) together with LPNHE (CNRS, IN2P3, Sorbonne Université and Université de Paris) and the WINLIGHT Systems company based in Pertuis (France), were in charge of integrating and validating the performance requirements of the ten full spectrographs, equipped with their cryostats, shutters and other mechanisms. We present a summary of our activity which allowed an efficient validation of the systems in a short-time schedule. We detail the main results. We emphasize the benefits of our approach and also its limitations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring mounting solutions for cryogenically cooled thin crystal optics in high power density x-ray free electron lasers

This study investigates three mounting methods—clamping, soldering, and a hybrid clamping–soldering approach—for cryogenically cooled thin diamond crystals crucial to stable operation of X-ray Free Electron Laser (XFEL) systems. While clamping methods exhibit temperature resilience and flexibility, meticulous design is required to prevent stress-induced warping and reduce thermal contact area. Soldering methods offer reliable mechanical and thermal bonding but encounter challenges due to the coefficient of thermal expansion mismatch at cryogenic temperatures. The hybrid method, integrating clamping and soldering with strain relief cuts, effectively mitigates overall distortion caused by mounting and XFEL thermal loads. These findings offer a novel mounting solution for high-performance x-ray optics in XFEL research and applications, ensuring stability and optimal functionality in cryogenic conditions.

Instruments & Instrumentation↗

A 20 Gbps PAM4 data transmitter ASIC for particle physics experiments

We present the design and test results of a novel data transmitter ASIC operating up to 20.48 Gbps with 4-level Pulse-Amplitude-Modulation (PAM4) for particle physics experiments. This ASIC, named GBS20, is fabricated in a 65 nm CMOS technology. Two serializers share a 5.12 GHz Phase Locked Loop (PLL) clock. The outputs from the serializers are combined into a PAM4 signal that directly drives a Vertical-Cavity-Surface-Emitting-Laser (VCSEL). The input data channels, each at 1.28 Gbps, are scrambled with an internal 2$^{7}$-1 Pseudo-Random Binary Sequence (PRBS), which also serves as a frame aligner. GBS20 is tested to work at 10.24 and 20.48 Gbps with a VCSEL-based Transmitter-Optical-Subassembly (TOSA). The power consumption of GBS20 is below 238 mW and reduced to 164 mW in the low-power mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ spectroscopic ellipsometry for real-time characterization of the effects of high-flux helium plasmas on tungsten surfaces

Tungsten samples were exposed to He plasmas generated by an RF source (Γ i = 3.5 x 10 16 He cm -2 s -1 , ion energy = 92 eV.) The range of exposure conditions selected here is conducive to the growth of nearsurface He bubbles, and at higher fluence, the formation of W nanotendrils ranging between 50 — 100 nm in diameter. The evolution of these surface features was probed using a fixed-angle ellipsometer (280 — 1000 nm wavelength range) with direct line-of-sight to the sample. Over the parameter space explored here, changes in the two angles (p, S) that define the polarization of the reflected light followed a distinct trajectory with increasing plasma fluence. Ex-situ ellipsometry of 22 additional tungsten specimens tested at a wide range of plasma fluences and temperatures mapped onto these in-situ results well. We used helium ion microscopy and focused ion beam profiling to provide a direct calibration of the ellipsometry measurements. Our results indicate that for a reproducible process such as the growth helium-induced surface morphologies, ellipsometry is a practical in-situ diagnostic to study how fusion plasmas modify materials. To study more general effects of plasmas on surfaces, including co-deposition and sputtering, different approaches to modelling the optical properties of the exposed surfaces are also considered.

36 MATERIALS SCIENCE↗

Optical Particle Measurements during EPCAPE Field Campaign Report

This campaign requested the deployment of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility optical particle counter (OPC) at the first ARM Mobile Facility (AMF1) located at the Scripps Pier in La Jolla, California during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE). The addition of the OPC was requested for two reasons. (1) Close the gap between the scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) size distribution from the Aerosol Observing System (AOS) measurements. (2) Principal investigator Petters has been working with Tracking Aerosol Convection Interaction Experiment (TRACER) data to compute particle fluxes from Doppler lidar (Petters et al. 2024). Briefly, backscatter flux is obtained using the eddy covariance technique using the Doppler vertical velocity and attenuated backscatter. Building upon prior studies, we were able to relate backscatter to particle number concentration by calibrating the lidar retrievals against optical particle counter-measured ground-based aerosol size distribution and radiosonde-interpolated relative humidity at lidar sample height. Performing similar analysis was of interest to EPCAPE to better understand the emissions and vertical transport of large particles into the overlying stratus clouds. However, as stated above, this analysis requires an optical size distribution that covers the 0.3-30-μm-diameter size range. The OPC was deployed between 2023-04-14 and 2024-02-14. The deployment, data quality analysis, and data archiving was handled by the DOE ARM instrument mentor team without additional involvement by the principal investigator. Data quality was marked as “routine” for the majority of the campaign.

54 ENVIRONMENTAL SCIENCES↗

Fungal elemental profiling unleashed through rapid laser-induced breakdown spectroscopy (LIBS)

Elemental profiling of fungal species as a phenotyping tool is an understudied topic and is typically performed to examine plant tissue or non-biological materials. Traditional analytical techniques such as inductively coupled plasma–optical emission spectroscopy (ICP-OES) and inductively coupled plasma–mass spectrometry (ICP-MS) have been used to identify elemental profiles of fungi; however, these techniques can be cumbersome due to the difficulty of preparing samples. Additionally, the instruments used for these techniques can be expensive to procure and operate. Laser-induced breakdown spectroscopy (LIBS) is an alternative elemental analytical technique—one that is sensitive across the periodic table, easy to use on various sample types, and is cost-effective in both procurement and operation. LIBS has not been used on axenic filamentous fungal isolates grown in substrate media. In this work, as a proof of concept, we used LIBS on two genetically distinct fungal species grown on a nutrient-rich and nutrient-poor substrate media to determine whether robust elemental profiles can be detected and whether differences between the fungal isolates can be identified. This data set contains the raw LIBS spectral data for the summarized results described inRush, et. al. 2024

elemental profiling↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparing optical four-flux model results with experimental data obtained by integrating sphere measurements

Four-flux theory is a way to model scattering through multiple layers of a system based on diffuse and collimated properties. When compared with measurement results obtained using an integrating sphere or a goniophotometer, an approximation is often made as the physical instrument cannot separate the collimated component from the diffuse light scattered in the forward direction. This paper tries to clarify the meaning of the word diffuse for the different cases and outlines simple corrections to improve the accuracy when comparing four-flux models and measured data based on sample haze and the geometry of the integrating sphere.

Bilokur, Maryna (ORCID:0000000191839650)↗

TRACER Carbonaceous Aerosols Thrust – University of California, Davis Field Campaign Report

The broader U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign aims to increase our understanding of convective cloud life cycles and aerosol-convection interactions. Our TRACER Carbonaceous Aerosols Thrust-University of California, Davis (TRACER-CAT-UCDavis) study complemented these broader aims by characterizing and quantifying the optical properties and composition of carbonaceous aerosols during part of the TRACER intensive sampling period (July 1- July 31, 2022) at the first ARM Mobile Facility (AMF1) main site (M1) in La Porte, Texas. Our measurements complemented the suite of instrumentation already provided by the AMF1, expanding the capabilities through deployment of unique, state-of-the-science instrumentation. The instrumentation included: (i) two cavity-attenuated phase shift spectroscopy single-scatter albedo (CAPS-SSA) instruments operating at 530 nm and 630 nm, and that were modified to characterize particle light absorption, extinction, and scattering at elevated humidities; (ii) the UC Davis dual-wavelength cavity ringdown-photoacoustic spectrometer (CRD-PAS), which characterizes dry particle extinction and absorption at 405 nm and 532 nm; (iii) a soot particle aerosol mass spectrometer (SP-AMS) that operated in “laser only” mode that characterized the size-dependent compositions of black carbon (BC)-containing particles; (v) a thermal denuder, to remove coatings on particles; and (vi) a scanning electrical mobility sizer (SEMS), to characterize particle mobility diameters from 10-1300 nm. Our measurements occurred alongside complementary observations made by Los Alamos National Laboratory (LANL) during the TRACER-CAT-LANL study, including a humidified CAPS-SSA instrument operating at 450 nm. Our primary scientific interest is in understanding the relationship between particle composition and light absorption, with a particular focus on the influence of water uptake. While it is known that coatings on BC can enhance absorption, the extent to which this occurs in the atmosphere and the specific role that water plays as a coating remain unclear. The TRACER-CAT-UCDavis measurements were made with near-complete coverage for the CRD-PAS, SP-AMS, and SEMS throughout the intensive period. The UC Davis humidified CAPS-SSA instruments had significant challenges with operation owing to the demanding conditions (large temperature fluctuations, high humidity), exacerbated by supply chain issues that delayed resolution of these challenges. However, the humidified CAPS-SSA instrument operated by LANL operated throughout the intensive period with near-complete coverage. The dry light extinction measurements from the CRD-PAS measurements and the LANL CAPS-SSA exhibited a good correlation, although the CAPS-SSA systematically measured greater extinction values than expected. While all instruments, with the exception of an aerodynamic particle sizer (APS), measured behind a common particulate matter (PM)2.5 μm cyclone, the greater extinction measured by the LANL CAPS-SSA compared to the CRD-PAS may have resulted from different losses of larger particles in the sampling lines from the cyclone to the instruments; the tubing length was shorter from the cyclone to the LANL CAPS-SSA, consistent with this idea. A summary of the TRACER-CAT-UCDavis measurements, along with some of the TRACER-CAT-LANL measurements, are shown in the figure below. Notably, there were periods when the contributions of presumed dust were substantial and even dominated the observed light extinction and absorption. Also, there was a clear shift in the behavior of submicron particles from before July 16, 2022 to after, with the prior period exhibiting regular episodes of new particle formation and the latter period exhibiting rapid variations in the concentrations of small particles.

54 ENVIRONMENTAL SCIENCES↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Image mapping for multiple charge state beams using a beam induced fluorescence profile monitors

Work continues on a minimally invasive, nitrogen fluorescence gas sheet at the Facility for Rare Isotope Beams (FRIB). A low density gas sheet may be used to observe the 2D transverse beam profile of high intensity, multiple charge state beams with minimal interference. Spatially and temporally correlated profiles are of particular interest in locations where there is significant charge state spread, such as the FRIB linac folding segments. A low-density gas sheet measurement system offers advantages for gas handling in nitrogen sensitive areas, however signal intensity is significantly lower than techniques using higher density gas sheets and jets. This work discusses measurement considerations for photon distributions generated by several spatially separated interaction points and design considerations for a high-sensitivity optics system for handling the expected low signal intensity.

Accelerator Physics↗

Spectroscopic investigation of historical uranium glasses

Here, we present spectroscopic investigations of uranium in two historical glasses. A 1920's-1930's Art Deco (Bagley Carnival) green soda-lime-silica uranium glass bowl and a 1930's-1940's (Thomas Webb) yellow full lead crystal uranium glass vase were studied using optical absorption spectroscopy, XRF and SEM-EDX, X-band EPR and High- Energy Resolution Fluorescence-Detected (HERFD)-XANES. Uranium speciation may be different in the two glasses. Uranium occurs as uranyl groups (UO 2 2+ ) with minority reduced uranium species, mostly as U(V), more important in the Webb glass than in the Bagley glass. The differences between the two glasses arise from the fining procedure and result from the presence of other multivalent elements and differences in base glass composition. Electron Paramagnetic Resonance (EPR) spectra show the presence of an incipient signal close to g~2, partially annealed by heating to 550 °C, which we assign to a small concentration of radiation-induced defects caused by uranium decay. The presence of multivalent glass components in addition to U (As + Cu + Fe in the Bagley glass and Sb + Fe in the Webb glass) can trap the electron-hole pairs generated by the presence of uranium. This may explain the weakness of this signal in these glasses that anyway received a limited radiation dose since their fabrication. The low activity of these glasses, close to the background radiation, confirms that there is no danger to exhibiting them in museums.

36 MATERIALS SCIENCE↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗