Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microgravity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Role for Lower Extremity Interstitial Fluid Volume Changes in the Development of Orthostasis after Simulated Microgravity

Reentry orthostasis after exposure to the conditions of spaceflight is a persistent problem among astronauts. In a previous study, a computer model systems analysis was used to examine the physiologic mechanisms involved in this phenomenon. In this analysis, it was determined that an augmented capacitance of lower extremity veins due to a fluid volume contracture of the surrounding interstitial spaces during spaceflight results in an increase in sequestered blood volume upon standing and appears to be the initiating mechanism responsible for reentry orthostasis. In this study, we attempt to validate the central premise of this hypothesis using a ground-based spaceflight analog. 10 healthy subjects were placed at bed rest in a 6 head down tilt position for 60 days of bed rest. The impact of adaptations in interstitial fluid volume and venous capacitance in the lower extremities were then observed during a standard tilt test protocol performed before and after the confinement period. The interstitial thickness superficial to the calcaneous immediately below the lateral malleolus was measured using ultrasound with a 17-5 MHz linear array transducer. Measurements of the changes in anterior tibial vein diameter during tilt were obtained by similar methods. The measurements were taken while the subjects were supine and then during upright tilt (80') for thirty minutes, or until the subject had signs of presyncope. Additional measurements of the superficial left tibia interstitial thickness and stroke volume by standard echocardiographic methods were also recorded. In addition, calf compliance was measured over a pressure range of 10-60 mmHg, using plethysmography, in a subset of these subjects (n = 5). There was a average of 6% diminution in the size of the lower extremity interstitial space as compared to measurements acquired prior to bed rest. This contracture of the interstitial space coincided with a subsequent relative increase in the percentage change in tibial vein diameter and stroke volume upon tilting in contrast to the observations made before bed rest (54 vs 23% respectively). Compliance in the calf increased by an average of 36% by day 27 of bedrest. A systems analysis using a computer model of cardiovascular physiology suggests that microgravity induced interstitial volume depletion results in an accentuation of venous blood volume sequestration and is the initiating event in reentry orthostasis. This hypothesis was tested in volunteer subjects using a ground-based spaceflight analog model that simulated the body fluid redistribution induced by microgravity exposure. Measurements of changes in the interstitial spaces and observed responses of the anterior tibial vein with tilt, together with the increase in calf compliance, were consistent with our proposed mechanism for the initiation of postflight orthostasis often seen in astronauts.

Platts, Steven H.↗

Gas-Liquid Separation Strategies in Microgravity Environment

Bubble entrainment in liquids represents a serious problem in the microgravity environment. Whenever bubbles are entrained in a liquid,they tend to remain stationary in the liquid bulk in the absence of any external forcing. This is due to the reduction or complete absence of the buoyancy force in the microgravity environment, Thus the buoyancy force can not the be exploited to place the bubbles at the top of the liquid volume as in Ig(sub o) conditions. This situation represents a serious drawback in many space based engineering and scientific applications. We have demonstrated in a series of low gravity experiments conducted during parabolic flight on board aircraft that bubbles can be controlled in such a manner as to increase,the probability of their expulsion from a liquid bulk. In these tests the liquid'bulk was made either to be contained within, or to flow through specially designed containers using capillary force alone. Such containers appear to facilitate bubble removal, from the liquid bulk. Different successful liquid flow configurations will be discussed and the efficacy of the resulting bubble expulsion mechanisms will be demonstrated.

Antar, Basil N.↗

Microgravity Droplet Combustion in CO2 Enriched Environments at Elevated Pressures

Microgravity droplet combustion experiments were performed in elevated concentrations of CO2 at pressures of 1.0 atm, 3.0 atm, and 5.0 atm to examine the effects of a radiatively participating suppression agent in space applications. Methanol and n-heptane droplets, with an initial diameter of 2.0 mm supported on a quartz fiber, were used in these experiments. The ambient O2 concentration was held constant at 21% and the CO2 concentrations ranged from 0% to a maximum of 70%, by volume with the balance consisting of N2 . Results from the methanol tests showed slight decreases in burning rates with increased CO2 concentrations at all ambient pressures. The n-heptane tests show slight increases in burning rates with increasing CO2 concentrations at each pressure level. Instantaneous radiative heat flux was also measured using both a broadband radiometer (i.e., wavelengths from 0.6 microns to 40.0 microns) and a narrowband radiometer (i.e., centered at 5.6 microns with a filter width at half maximum of 1.5 microns). Radiative exchanges between the droplet and surrounding gases as well as the soot field produce departures from the classical quasisteady theory which would predict a decrease in burning rates with increasing CO2 concentrations in microgravity.

Hicks, Michael C.↗

Development of the Gecko (Pachydactylus turneri) Animal Model during Foton M-2 to Study Comparative Effects of Microgravity in Terrestrial and Aquatic Organisms

Terrestrial organisms exposed to microgravity during spaceflight experience degeneration in bone, muscle, and possibly other tissues that require gravity-mediated mechanical stimulation for normal regenerative growth. In the Gecko experiment aboard Foton M-2, we flew for the first time, five terrestrial Pachydactylus turneri specimens to develop a model of microgravity effects comparable to the newt Pleurodeles waltl, a well-established model organism for spaceflight. These lower vertebrate species have similar body plans and size, are poikilothermic, have tissue regenerative ability, and are adapted to moderate periods of fasting. Furthermore the gecko (Pachydactylus) can also survive prolonged periods without water. In pre-flight control experiments and after a 16-day Foton M-2 spaceflight without food or water, the geckos were recovered and showed no apparent negative health effects. However, detailed analysis of bone mass and architecture by micro Computed Tomography { pCT), showed that both synchronous control and spaceflight animals lost significant amounts of cancellous bone in the distal femur and humerus relative to basal controls. In addition, cell cycle analysis of 30h post-flight liver tissue reveals a shift of DNA content from G2 and S to G1, both in spaceflight and synchronous controls. Together, these results suggest that housing conditions alone induce rapid catabolism of cancellous bone and reduced normal tissue regeneration. Further use of the gecko Puchydactylus turneri as a spaceflight model requires modification of housing conditions, possibly by including water and food, or changing other factors such as eliminating housing stresses to obtain stable bone structure and tissue regeneration during spaceflight experiments.

Almeida, E. A.↗

Free Fall Plasma-Arc Reactor for Synthesis of Carbon Nanotubes in Microgravity

High temperatures inside the plasma of a carbon arc generate strong buoyancy driven convection which has an effect on the growth and morphology of the single-walled carbon nanotubes (SWNTs). To study the effect of buoyancy on the arc process, a miniature carbon arc apparatus was designed and developed to synthesize SWNTs in a microgravity environment substantially free from buoyant convective flows. An arc reactor was operated in the 2.2- and 5.18-second drop towers at the NASA Glenn Research Center. The apparatus employed a 4 mm diameter anode and was powered by a portable battery pack capable of providing in excess of 300 amps at 30 volts to the arc for the duration of a 5-second drop. However, the principal result is that no dramatic difference in sample yield or composition was noted between normal gravity, 2.2-and 5-second long microgravity runs.

Alford, J. M.↗

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.↗

Intravenous Fluid Mixing in Normal Gravity, Partial Gravity, and Microgravity: Down-Selection of Mixing Methods

The missions envisioned under the Vision for Space Exploration will require development of new methods to handle crew medical care. Medications and intravenous (IV) fluids have been identified as one area needing development. Storing certain medications and solutions as powders or concentrates can both increase the shelf life and reduce the overall mass and volume of medical supplies. The powders or concentrates would then be mixed in an IV bag with Sterile Water for Injection produced in situ from the potable water supply. Fluid handling in microgravity is different than terrestrial settings, and requires special consideration in the design of equipment. This document describes the analyses and down-select activities used to identify the IV mixing method to be developed that is suitable for ISS and exploration missions. The chosen method is compatible with both normal gravity and microgravity, maintains sterility of the solution, and has low mass and power requirements. The method will undergo further development, including reduced gravity aircraft experiments and computations, in order to fully develop the mixing method and associated operational parameters.

Niederhaus, Charles E.↗

Solution Growth and Characterization of Single Crystals on Earth and in Microgravity

Crystal growth has been of interest to physicists and engineers for a long time because of their unique properties. Single crystals are utilized in such diverse applications as pharmaceuticals, computers, infrared detectors, frequency measurements, piezoelectric devices, a variety of high-technology devices, and sensors. Solution crystal growth is one of the important techniques to grow a variety of crystals when the material decomposes at the melting point and a suitable solvent is available to make a saturated solution at a desired temperature. In this Technical Memorandum (TM) an attempt is made to give the fundamentals of growing crystals from solution including improved designs of various crystallizers. Since the same solution crystal growth technique could not be used in microgravity, the authors proposed a new cooled-sting technique to grow crystals in space. The authors experience from conducting two Space Shuttle solution crystal growth experiments are also detailed in this TM and the complexity of solution growth experiments to grow crystals in space are also discussed. These happen to be some of the early experiments performed in space, and various lessons learned are described. A brief discussion of protein crystal growth that shares basic principles of the solution growth technique is given, along with some flight hardware information for growth in microgravity.

Aggarwal, M. D.↗

Spinal Elongation and its Effects on Seated Height in a Microgravity Environment

Objectives: 1. To collect spinal elongation induced seated height data for subjects exposed to microgravity environments. 2. To provide information relating to the seated height rate of change over time for astronauts subjected to microgravity. We will collect: Seated Height measurement (ground & flight) and digital still photograph (ground and flight).

Rajulu, Sudhakar↗

Dewetting and Segregation of Zn-Doped InSb in Microgravity Experiments

In directional solidification, dewetting is characterized by the lack of contact between the crystal and the crucible walls, due to the existence of a liquid meniscus at the level of the solid-liquid interface. This creates a gap of a few tens of micrometers between the crystal and the crucible. One of the immediate consequences of this phenomenon is the dramatic improvement of the quality of the crystal. This improvement is partly due to the modification of the solid-liquid interface curvature and partly to the absence of sticking and spurious nucleation at the crystal-crucible interface. Dewetting has been, commonly observed during the growth of semiconductors in crucibles under microgravity conditions where it appears to be very stable: the gap between the crystal and the crucible remains constant along several centimetres of growth. The physical models of the phenomenon are well established and they predict that dewetting should not occur in microgravity, if sufficient static pressure is imposed on the melt, pushing it towards the crucible. We present the results of InSb(Zn) solidification experiments conducted at the International Space Station (ISS) where, in spite of a spring exerting a pressure on the liquid, partial dewetting did occur. This surprising result is discussed in terms of force exerted .by the spring on the liquid and of possibility that the spring did not work properly. Furthermore, it appears that the segregation of the Zn was not affected by the occurrence of the dewetting. The data suggest that there was no significant interference of convection with segregation of Zn in InSb.

Ostrogorsky, A. G.↗

Preliminary Results of the Effect of Spinal Elongation in Microgravity on Seated Height

The Constellation Program is designing a new vehicle for future space travel to the International Space Station and to the Moon and beyond. One major accommodation and design issue that needs to be addressed with the current seat layout design is spinal elongation. Spinal elongation is the spinal growth that occurs due to straightening of the spinal curve and expansion of the inter-verbal discs in microgravity. Spinal elongation is critical to the design of the seats, seat layout, suit fit, and crew accommodation because of the implications it can have on the a safe return of the crewmembers or during the mission. Inadequate clearance between crewmembers and/or between crewmember hardware interfaces may potentially result in injury during the mission or upon returning to earth. Therefore, design requirements need to be determined that will allow for the elongation of the spine. The current requirement as specified in the Human Systems Integration Requirement (HSIR) document states that a 3% increase in standing height must be accommodated. However, it cannot be assumed that the amount of standing height growth is equivalent to the amount of spinal elongation because of the variation in body proportions between the lower body and torso. Thus, the purpose of this study was to determine the amount of spinal elongation for a seated posture for 6 Shuttle and 7 ISS missions. Crewmembers seated heights were collected before, during, and after spaceflight to determine the change in seated height and the amount of spinal growth that occurs due to microgravity. The changes in seated height will provide the designers with a design requirement that will allow for change in spinal growth for a seated posture. Preliminary results have shown that increase in seated height is greater than the 3% increase currently stated in the requirement.

Rajulu, Sudhakar↗

Simulating Bone Loss in Microgravity Using Mathematical Formulations of Bone Remodeling

Most mathematical models of bone remodeling are used to simulate a specific bone disease, by disrupting the steady state or balance in the normal remodeling process, and to simulate a therapeutic strategy. In this work, the ability of a mathematical model of bone remodeling to simulate bone loss as a function of time under the conditions of microgravity is investigated. The model is formed by combining a previously developed set of biochemical, cellular dynamics, and mechanical stimulus equations in the literature with two newly proposed equations; one governing the rate of change of the area of cortical bone tissue in a cross section of a cylindrical section of bone and one governing the rate of change of calcium in the bone fluid. The mechanical stimulus comes from a simple model of stress due to a compressive force on a cylindrical section of bone which can be reduced to zero to mimic the effects of skeletal unloading in microgravity. The complete set of equations formed is a system of first order ordinary differential equations. The results of selected simulations are displayed and discussed. Limitations and deficiencies of the model are also discussed as well as suggestions for further research.

Pennline, James A.↗

Ceramic material suitable for repair of a space vehicle component in a microgravity and vacuum environment, method of making same, and method of repairing a space vehicle component

A precursor of a ceramic adhesive suitable for use in a vacuum, thermal, and microgravity environment. The precursor of the ceramic adhesive includes a silicon-based, preceramic polymer and at least one ceramic powder selected from the group consisting of aluminum oxide, aluminum nitride, boron carbide, boron oxide, boron nitride, hafnium boride, hafnium carbide, hafnium oxide, lithium aluminate, molybdenum silicide, niobium carbide, niobium nitride, silicon boride, silicon carbide, silicon oxide, silicon nitride, tin oxide, tantalum boride, tantalum carbide, tantalum oxide, tantalum nitride, titanium boride, titanium carbide, titanium oxide, titanium nitride, yttrium oxide, zirconium diboride, zirconium carbide, zirconium oxide, and zirconium silicate. Methods of forming the ceramic adhesive and of repairing a substrate in a vacuum and microgravity environment are also disclosed, as is a substrate repaired with the ceramic adhesive.

Riedell, James A.↗

Smooth Pursuit Saccade Amplitude Modulation During Exposure to Microgravity

Russian investigators have reported changes in pursuit tracking of a vertically moving point stimulus during space flight. Early in microgravity, changes were manifested by decreased eye movement amplitude (undershooting) and the appearance of correction saccades. As the flight progressed, pursuit of the moving point stimulus deteriorated while associated saccadic movements were unchanged. Immediately postflight there was an improved execution of active head movements indicating that the deficiencies in pursuit function noted in microgravity may be of central origin. In contrast, tests of two cosmonauts showed that horizontal and vertical smooth pursuit were unchanged inflight. However, results of corresponding saccadic tasks showed a tendency toward the overshooting of a horizontal target early inflight with high accuracy developing later inflight, accompanied by an increased saccade velocity and a trend toward decreased saccade latency. Based on these equivocal results, we have further investigated the effects of space flight on the smooth pursuit mechanism during and after short duration flight, and postflight on returning MIR crewmembers. Sinusoidal target movement was presented horizontally at frequencies of 0.33 and 1.0 Hz. Subjects were asked to perform two trials for each stimulus combination: (1) moving eyes-only (EO) and (2) moving eyes and head (EH) with the target motion. Peak amplitude was 30 deg for 0.33 Hz trials and 15 deg for the 1.0 Hz trials. The relationship between saccade amplitude and peak velocity were plotted as a main sequence for each phase of flight, and linear regression analysis allowed us to determine the slope of each main sequence plot. The linear slopes were then combined for each flight phase for each individual subject. The main sequence for both EO and EH trials at both the 0.33 and 1.0 Hz frequencies during flight for the short duration flyers showed a reduction in saccade velocity and amplitude when compared to the preflight main sequence . This difference in the regression slopes between flight phase, head/eye condition (EO or EH), and pursuit target frequency was observed across all subjects (statistically significant at the p<0.02, df= 2). It is interesting to note that postflight for the short duration flyers there was an immediate recovery to the preflight main sequence across all trials. There were no significant differences observed between the preflight slopes for either head movement condition (EO vs. EH). When the immediate postflight (R+O) regression slopes were compared with the preflight slopes, there was a tendency (not significant) for both saccade amplitude and peak velocity to increase during the postflight testing. This tendency had vanished by R+ 1. Of particular interest was the redistribution of saccades during the latter stages of the flight and immediately postflight in the EO condition. At the 1.0 Hz frequency the saccades tended to be clustered near the lowest target velocity. It was also interesting to note that gaze performance (eye in skull + head in space) was consistently better during the EH condition; a finding also observed by our Russian colleagues. As the results of the long duration flight become available we expect that they will not only show that postflight effects will be similar to those observed during the short duration flights, but will also last for a greater period of time following flight. It is not clear what mechanism is responsible for the decreased peak saccadic velocity during flight unless the change is related to the control of retinal slip. For example, it is possible that saccades will tend to initially undershoot their targets by a small percentage and these saccades are then followed, if vision is available, by a small augmenting corrective saccade. It has been postulated that the functional significance of this undershooting tendency is to maintain the spatial representation of the target on the same side of the fovea (as opposedo racing across the fovea) and hence in the same cerebral hemisphere that initiated the primary saccade thus minimizing delays caused by an intra-hemispheric transfer of information . One could also speculate that with saccade velocities greater than normal, additional corrective saccades would be required to bring the target back on the fovea. A less plausible explanation of our findings could be fatigue. Yet it seems unlikely that our subjects would show lower velocities on all inflight test days while showing increased saccade velocities immediately following space flight where fatigue is usually the greatest. Finally, the redistribution effect noted late inflight is likely caused by adaptive changes. Overall, corrective saccades appeared to be used in maintaining gaze on target; reducing retinal slip and assisting space travelers in maintaining clear vision throughout the different phases of the space flight.

Reschke, M. F.↗

Altered TNF-Alpha, Glucose, Insulin and Amino Acids in Islets Langerhans Cultured in a Microgravity Model System

The present studies were designed to determine effects of a microgravity model system upon lipopolysaccharide (LPS) stimulated tumor necrosis factor alpha (TNF-alpha) activity and indices of insulin and fuel homeostasis of pancreatic islets of Langerhans. Islets (1726+/-1 17,150 u IEU) from Wistar Furth rats were treated as: 1) HARV (High Aspect Ratio Vessel cell culture) , 2) HARV plus LPS, 3) static culture, 4) static culture plus LPS. TNF-alpha (L929 cytotoxicity assay) was significantly increased in LPS-induced HARV and static cultures, yet the increase was more pronounced in the static culture group (p<0.05). A decrease in insulin concentration was demonstrated in the LPS stimulated HARV culture (p<0.05). We observed a greater glucose concentration and increased disappearance of arginine in islets cultured in HARVs. While nitrogenous compound analysis indicated a ubiquitous reliance upon glutamine in all experimental groups, arginine was converted to ornithine at a two-fold greater rate in the islets cultured in the HARV microgravity model system (p<0.05). These studies demonstrate alterations in LPS induced TNF-alpha production of pancreatic islets of Langerhans, favoring a lesser TNF activity in the HARV. These alterations in fuel homeostasis may be promulgated by gravity averaged cell culture methods or by three dimensional cell assembly.

Tobin, Brian W.↗

International Space Station Microgravity Analytical Model Correlation And Update

The acceleration environment aboard the completed International Space Station (ISS) is a key resource for scientific and technological endeavors. Hardware verification activIties and early measurements indicate that the ISS is well on the way of meeting these "Assembly Complete" "microgravity" provisions, however, the simulation models that compute these accelerations have, to date, lacked the high degree of empirical validation typical of standard aerospace industry practices. Assembly stage, on-orbit measurements are used to address this shortcoming and to develop higher confidence in the simulation models. The Phase I correlation results show the analyses to be consistently conservative, producing higher than measured levels. The 25 to 30% greater quasi-steady computations are deemed acceptable for verification. Updates are made to localized structural dynamic and vibroacoustic parameters that reduce responses in selected one-third octave bands by almost 50%. These models are then used for the Assembly Complete verification analysis which concludes that the ISS vehicle meets the ISS microgravity requirements with minor reservations. Two of the sixteen rack are marginally non-compliant in the quasi-steady regime, and operational constraints are needed on the U. S. Lab and ESA APM vacuum resource vents, and the Russian Resistive Exercise Device in the structural dynamic regime.

DelBasso, Steve↗

Analysis of Microgravity Experiments Conducted on the Apollo Spacecraft

This Technical Memorandum (TM) discusses the microgravity experiments carried out during the later missions of the Apollo program. Microgravity experiments took place during the Apollo 14, 16, and 17 missions and consisted of four experiments in various materials processing concentrations with two of the four experiments taking place over the course of two missions. Experiments consist of composite casting, electrophoresis, heat flow and convection, and liquid transfer. This TM discusses the background, the workup, execution, and results of each experiment. In addition, the historical significance of each experiment to future applications/NASA programs is discussed.

Sharpe, R. J.↗

Experimental Visualization of Bubble Formation from an Orifice In Microgravity in the Presence of Electric Fields

The formation of air bubbles injected into a stagnant, isothermal liquid in microgravity through an orifice was studied. The bubbles grew very large in microgravity. They attained a nearly spherical shape and showed pronounced affinity towards coalescence in the absence of electric fields and other perturbations. Under the influence of electric fields, periodic detachment was observed, with bubble sizes larger than in terrestrial conditions. The bubble shape was elongated. After detachment, the bubbles moved away from the electrode at which they formed without coalescing with other bubbles. Experimental data on bubble shape and size at detachment showed good agreement with models.

Herman, C.↗