Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Measurements and correction of the 1/1 error field in Wendelstein 7-X

In this paper, vacuum flux surface mapping is used to measure the error field in Wendelstein 7-X. Two methods for discriminating the perturbation from other co-resonant modes are applied: measurements of the helical axis shift in a magnetic configuration with the rotational transform barely above one on the axis; and measurements of the edge island structure with cancellation of intrinsic islands by divertor control coils. The normalized radial amplitude in Boozer coordinates is found to be about in the first case and about in the second one, with the discrepancy being attributable to different currents in the planar coils. The error field can be reliably compensated by using error field trim coils with currents about 100 A. Here, this compensation also helps to identify the error field of about . During plasma operation in divertor configurations, it is confirmed that the present field leads to asymmetries in the power distribution and that the compensation improves this symmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Sensitivity study

Power towers, a type of concentrating power tower technology, use a large number of heliostats to concentrate sunlight and produce renewable energy. Optical errors of heliostats can cause drastic losses in the efficiency of power-tower plants. Accurately measuring optical errors is crucial to assessing and improving plant performance. This analysis discusses an innovate non-intrusive optical (NIO) approach to measure slope, canting, and tracking errors by detecting distortions in the reflected tower structure in heliostat images. Further in this work a sensitivity study is carefully conducted to determine the uncertainty requirements to allow the method to calculate slope errors with an accuracy of 0.25 mrad. Measurement uncertainty sources include camera resolution and position uncertainty, tower position uncertainty, and number of collected images. Each uncertainty source is investigated to determine its impact on the accuracy of the slope-error calculation. A combination of theoretical results and experimental results obtained from data collected on a heliostat at Sandia National Laboratories is used to determine and validate uncertainty requirements. The analysis shows that a measurement uncertainty of 0.25 mrad can be realized by realistically controlling uncertainty sources when implementing the NIO method. It demonstrates the superior performance of NIO in performing in-situ optical characterization.

14 SOLAR ENERGY↗

Astrometric plates obtained at the primary focus of large aperture reflectors

Coma, astigmatism, and great differences in stellar magnitudes between photographed object and reference stars constitute the main sources of errors in measuring positional plates. These three sources of error can easily be eliminated by the method used at the Klet Observatory for obtaining precise observations of faint objects. The astrometric plates are taken by the method of two diaphragms. The first diaphragm, with a small central aperture; is located in front of the photographic plate. The second diaphragm is situated in front of the mirror. By a very short (of the order of tens of seconds) exposure a sufficient number of reference stars can be obtained throughout the entire plate. The stars are very well defined to the very edge of the plate and are easy to measure. Moreover, this method makes it possible to use plates of larger dimensions than usual so that it is always possible to find the necessary reference stars.

Markos, A.↗

Improved reconstruction stability for chemical shift encoded hyperpolarized 13 C magnetic resonance spectroscopic imaging using k‐t spiral acquisitions

Purpose A multiecho, field of view (FOV)‐oversampled k‐t spiral acquisition and direct iterative decomposition of water and fat with echo asymmetry and least‐squares estimation reconstruction is demonstrated to improve the stability of hyperpolarized 13 C magnetic resonance spectroscopic imaging (MRSI) in the presence of signal ambiguities attributed to low‐SNR (signal‐to‐noise‐ratio) species, local uncertainties in metabolite peaks, and echo‐to‐echo signal inconsistencies. Theory k‐t spiral acquisitions redistribute readout points to be more densely spaced radially in k‐space by acquiring an FOV and matrix that are oversampled by η . These more densely spaced spiral turns constitute effective intraspiral echoes and can supplement conventional interspiral echoes to improve spectral separation and reduce spectral cross‐talk to better resolve 13 C‐labeled species for spectroscopic imaging. Methods Digital simulations and imaging phantom experiments were performed for a range of interspiral echo spacings and η using multiecho, k‐t spiral acquisitions. Image spectral cross‐talk artifacts were evaluated both qualitatively and quantitatively as the percent error in measured metabolite ratios. In vivo murine experiments evaluated the feasibility of multiecho, k‐t spiral [1‐ 13 C]pyruvate MRSI to reduce spectral cross‐talk for 3 scenarios of different expected reconstruction stability. Results Digital simulations and imaging phantom experiments both demonstrated reduced or comparable image spectral cross‐talk and percent errors in measured metabolite ratios with increasing η and better choices of echo spacings. In vivo images displayed markedly reduced spectral cross‐talk in lactate images acquired with η = 7 versus η = 1. Conclusion The precision of hyperpolarized 13 C metabolic imaging and quantification in the presence of low‐SNR species, local uncertainties in metabolite resonances, and echo‐to‐echo signal inconsistencies can be improved with the use of FOV‐oversampled k‐t spiral acquisitions.

Macdonald, Erin B.↗

The design and analysis of single flank transmission error tester for loaded gears

To strengthen the understanding of gear transmission error and to verify mathematical models which predict them, a test stand that will measure the transmission error of gear pairs under design loads has been investigated. While most transmission error testers have been used to test gear pairs under unloaded conditions, the goal of this report was to design and perform dynamic analysis of a unique tester with the capability of measuring the transmission error of gears under load. This test stand will have the capability to continuously load a gear pair at torques up to 16,000 in-lb at shaft speeds from 0 to 5 rpm. Error measurement will be accomplished with high resolution optical encoders and the accompanying signal processing unit from an existing unloaded transmission error tester. Input power to the test gear box will be supplied by a dc torque motor while the load will be applied with a similar torque motor. A dual input, dual output control system will regulate the speed and torque of the system. This control system's accuracy and dynamic response were analyzed and it was determined that proportional plus derivative speed control is needed in order to provide the precisely constant torque necessary for error-free measurement.

Bassett, Duane E.↗

Performance of Laser-Based Electronic Devices for Structural Analysis of Amazonian Terra-Firme Forests

Tropical vegetation biomass represents a key component of the carbon stored in global forest ecosystems. Estimates of aboveground biomass commonly rely on measurements of tree size (diameter and height) and then indirectly relate, via allometric relationships and wood density, to biomass sampled from a relatively small number of harvested and weighed trees. Recently, however, novel in situ remote sensing techniques have been proposed, which may provide nondestructive alternative approaches to derive biomass estimates. Nonetheless, we still lack knowledge of the measurement uncertainties, as both the calibration and validation of estimates using different techniques and instruments requires consistent assessment of the underlying errors. To that end, we investigate different approaches estimating the tropical aboveground biomass in situ. We quantify the total and systematic errors among measurements obtained from terrestrial light detection and ranging (LiDAR), hypsometer-based trigonometry, and traditional forest inventory. We show that laser-based estimates of aboveground biomass are in good agreement (<10% measurement uncertainty) with traditional measurements. However, relative uncertainties vary among the allometric equations based on the vegetation parameters used for parameterization. We report the error metrics for measurements of tree diameter and tree height and discuss the consequences for estimated biomass. Despite methodological differences detected in this study, we conclude that laser-based electronic devices could complement conventional measurement techniques, thereby potentially improving estimates of tropical vegetation biomass.

54 ENVIRONMENTAL SCIENCES↗

Characterizing Midcircuit Measurements on a Superconducting Qubit Using Gate Set Tomography

Measurements that occur within the internal layers of a quantum circuit—midcircuit measurements—are a useful quantum-computing primitive, most notably for quantum error correction. Midcircuit measurements have both classical and quantum outputs, so they can be subject to error modes that do not exist for measurements that terminate quantum circuits. In this work, we show how to characterize midcircuit measurements, modeled by quantum instruments, using a technique that we call quantum instrument linear gate set tomography (QILGST). We then apply this technique to characterize a dispersive measurement on a superconducting transmon qubit within a multiqubit system. By varying the delay time between the measurement pulse and subsequent gates, we explore the impact of residual cavity photon population on measurement error. QILGST can resolve different error modes and quantify the total error from a measurement; in our experiment, for delay times above 1000 ns we measure a total error rate (i.e., half diamond distance) of ϵ$\diamond$ = 8.1 ± 1.4%, a readout fidelity of 97.0 ± 0.3%, and output quantum-state fidelities of 96.7 ± 0.6% and 93.7 ± 0.7 % when measuring 0 and 1, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A multi-wavelength, high-contrast contact radiography system for the study of low-density aerogel foams

A multi wavelength, high contrast contact radiography system has been developed to characterize density variations in ultralow density aerogel foams. These foams are used to generate a ramped pressure drive in materials strength experiments at the National Ignition Facility (NIF) and require precision characterization in order to reduce errors in measurements. Here, the system was used to characterize density variations in carbon and silicon based aerogels to ~10.3% accuracy with ~30 μm spatial resolution. The system description, performance and measurement results collected using a 17.8 mg/cc carbon based JX–6 (C 20 H 30 ) aerogel are discussed in this paper.

42 ENGINEERING↗

Integrated Nondestructive Assay Systems to Estimate Plutonium in Spent Fuel Assemblies

An integrated nondestructive assay (NDA) system combining active (neutron generator) and passive neutron detection and passive gamma (PG) detection is being analyzed in order to estimate the amount of plutonium, verify initial enrichment, burnup, and cooling time, and detect partial defects in a spent fuel assembly (SFA). Active signals are measured using the differential die-away (DDA), delayed neutron (DN), and delayed gamma (DG) techniques. Passive signals are measured using total neutron (TN) counts and both gross and spectral resolved gamma counts. To quantify how a system of several NDA techniques is expected to perform, all of the relevant NDA techniques listed above were simulated as a function of various reactor conditions such as initial enrichment, burnup, cooling time, assembly shuffling pattern, reactor operating conditions (including temperature, pressure, and the presence of burnable poisons) by simulating the NDA response for five sets of light water reactor assemblies. In this study, we compare the performance of several exploratory model-fitting options (including neural networks, adaptive regression with splines, iterative bias reduction smoothing, projection pursuit regression, and regression with quadratic terms and interaction terms) to relate data simulated with measurement and model error effects from various subsets of the NDA techniques to the total Pu mass. Isotope masses for SFAs and expected detector responses (DRs) for several NDA techniques are simulated using MCNP, and the DRs become inputs to the fitting process. Such responses include eight signals from DDA, one from DN, one from TN, and up to seven from PG; the DG signal will be examined separately. Results are summarized using the root-mean-squared estimation error for plutonium mass in held-out subsets of the data for a range of model and measurement error variances. Different simulation assumptions lead to different spent fuel libraries relating DRs to Pu mass. Some results for training with one library and testing with another library are also given.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

Evaluation of single-footprint AIRS CH4 Profile Retrieval Uncertainties Using Aircraft Profile Measurements

We evaluate the uncertainties of methane optimal estimation retrievals from single footprint thermal infrared observations from the Atmospheric Infrared Sounder (AIRS). These retrievals are primarily sensitive to atmospheric methane in the mid-troposphere through the lower stratosphere (~2 to ~17 km). We compare to in situ observations made from aircraft during the Hiaper Pole to Pole Observations (HIPPO), the NASA Atmospheric Tomography Mission (ATom) campaigns, and from the NOAA ESRL aircraft network, between the surface and 5-13 km, across a range of years, latitudes between 60 S to 80 N, and over land and ocean. After a global, pressure dependent bias correction, we find that the land and ocean have similar biases and that the reported observation error (combined measurement and interference errors) of ~27 ppb is consistent with the standard deviation between aircraft and individual AIRS observations. A single measurement has measurement (noise related) uncertainty of ~17 ppb, a ~20 ppb uncertainty from radiative interferences (e.g. from water, temperature, etc.), and ~ 30 ppb due to “smoothing error”, which is partially removed when making comparisons to in situ measurements or models in a way that account for this regularization. We estimate a 16 ppb validation error because the aircraft typically did not measure methane at altitudes where the AIRS measurements have some sensitivity, e.g. the stratosphere. Daily averaged AIRS measurements of at least 9 observations over spatio-temporal domains of < 1 degree and 1 hour have a standard deviation of ~17 ppb versus aircraft, likely because the observation errors from temperature and water vapor (for example) are only partly reduced through averaging. Seasonal averages can reduce this ~17 ppb uncertainty further to ~10 ppb, as determined through comparison with NOAA aircraft, likely because uncertainties related to radiative effects of temperature and water vapor can be reduced when averaged over a season.

Susan Kulawik↗

Minimizing selective availability error on Topex GPS measurements

GPS measurements made at Topex/Poseidon and the accompanying ground tracking sites will be affected by the selective availability. Although in principle the effects may be removed by differencing between receivers observing the same GPS satellites, this requires accurate synchronization of all receiver clocks. In the case of Topex/Poseidon application, there are two sources of imperfect clock synchronization. The first and larger is due to the constantly drifting clock onboard Topex, which may cause a residual effect as large as 10 cm on Topex carrier phase and 1 m on Topex pseudorange. The second is due to light-time differences between receivers observing the same GPS satellites, which may amount to a few mm error. In this paper a data reduction scheme which incorporates a low-order polynomial interpolation and carrier phase smoothing on pseudorange acquired at Topex and ground receivers is described; a simulation analysis is given demonstrating the effectiveness of the scheme for reducing the GPS S/A effects; and comparison with other schemes is discussed.

Wu, S. C.↗

Design guidelines for avoiding thermo-acoustic oscillations in helium piping systems

Thermo-acoustic oscillations are a commonly observed phenomenon in helium cryogenic systems, especially in tubes connecting hot and cold areas. The open ends of these tubes are connected to the lower temperature (typically at 4.2 K), and the closed ends of these tubes are connected to the high temperature (300K). Cryogenic instrumentation installations provide ideal conditions for these oscillations to occur due to the steep temperature gradient along the tubing. These oscillations create errors in measurements as well as an undesirable heat load to the system. The work presented here develops engineering guidelines to design oscillation-free helium piping. This work also studies the effect of different piping inserts and shows how the proper geometrical combinations have to be chosen to avoid thermo-oscillations. The effect of an 80 K intercept is also studied and shows that thermo-oscillations can be dampened by placing the intercept at an appropriate location.

43 PARTICLE ACCELERATORS↗

Measuring Large Amplitude Surface Figure Error using Coordinate Metrology

Advances in optical testing are as important as advances in optical fabrication, because one can make only what one can measure, particularly for unconventional prescriptions, like aspheric and freeform optics. A new, high-precision metrology capability is utilized to close the gap between interferometric testing and lower precision, contact-probe-based coordinate measuring machines or laser tracker/radar metrology to accurately measure surfaces with large figure error. This nearly universal optical testing method employs an ultra-precision coordinate measuring machine equipped with a non-contact probe. It was developed to characterize a broad spectrum of optical surfaces including ones with high slopes, impossible to measure using traditional interferometric testing. Optical components, covering a wide range of prescriptions, such as large convex conics, high-sloped aspherics, grazing-incidence x-ray optics, and highly deformed flats, were successfully measured. The resulting data were reduced using custom-developed routines to determine the optic’s alignment, surface departure from design, and the as-built optical prescription. This information guided the fabrication and modeling of these optical components

Manal Khreishi↗

Quantification of beam complexity in intensity-modulated radiation therapy treatment plans

Purpose: Excessive complexity in intensity-modulated radiation therapy (IMRT) plans increases the dose uncertainty, prolongs the treatment time, and increases the susceptibility to changes in patient or target geometry. To date, the tools for quantitative assessment of IMRT beam complexity are still lacking. In this study, The authors have sought to develop metrics to characterize different aspects of beam complexity and investigate the beam complexity for IMRT plans of different disease sites. Methods: The authors evaluated the beam complexity scores for 65 step-and-shoot IMRT plans from three sites (prostate, head and neck, and spine) and 26 volumetric-modulated arc therapy (VMAT) plans for the prostate. On the basis of the beam apertures and monitor unit weights of all segments, the authors calculated the mean aperture area, extent of aperture shape irregularity, and degree of beam modulation for each beam. Then the beam complexity values were averaged to obtain the complexity metrics of the IMRT plans. The authors studied the correlation between the beam complexity metrics and the quality assurance (QA) results. Finally, the effects of treatment planning parameters on beam complexity were studied. Results: The beam complexity scores were not uniform among the prostate IMRT beams from different gantry angles. The lateral beams had larger monitor units and smaller shape irregularity, while the anterior-posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest aperture irregularity, beam modulation, and normalized monitor units; the head and neck IMRT plans had large beam irregularity and beam modulation; and the spine stereotactic radiation therapy plans often had small beam apertures, which may have been associated with the relatively large discrepancies between planned and QA measured doses. There were weak correlations between the beam complexity scores and the measured dose errors. The prostate VMAT beams showed greater complexity than the prostate step-and-shoot IMRT beams. In the treatment planning process, the beam complexity increased as the minimum segment area decreased and as the number of optimization iterations and the maximum number of segments increased. Conclusions: The proposed metrics were effective in characterizing the beam complexity of different disease sites and for different treatment modalities. Efforts should be made to reduce the unnecessary complexity of IMRT beams to minimize the radiation dose uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sideslip-induced static pressure errors in flight-test measurements

During lateral flight-test maneuvers of a V/STOL research aircraft, large errors in static pressure were observed. An investigation of the data showed a strong correlation of the pressure record with variations in sideslip angle. The sensors for both measurements were located on a standard air-data nose boom. An algorithm based on potential flow over a cylinder that was developed to correct the pressure record for sideslip-induced errors is described. In order to properly apply the correction algorithm, it was necessary to estimate and correct the lag error in the pressure system. The method developed for estimating pressure lag is based on the coupling of sideslip activity into the static ports and can be used as a standard flight-test procedure. The estimation procedure is discussed and the corrected static-pressure record for a typical lateral maneuver is presented. It is shown that application of the correction algorithm effectively attenuates sideslip-induced errors.

Parks, Edwin K.↗