Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Male”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

CT and MRI features of undifferentiated carcinomas with osteoclast-like giant cells of the pancreas: a case series

Purpose: The purpose of this case series was to describe computed tomography (CT) and magnetic resonance imaging (MRI) features of undifferentiated carcinoma with osteoclast-like giant cells of the pancreas. Methods: Institutional ethics review board approval was obtained, and informed consent was waived for this case series. We reviewed CT and MRI of patients with pathologically confirmed undifferentiated carcinoma with osteoclast-like giant cells of the pancreas found in the medical records of our hospital between 2006 and 2016. Results: Seven patients (3 males and 4 females; age, 59–82 years (mean, 71)) with confirmation by surgical resection (n = 3) or biopsy (n = 4) were identified. They underwent CT (n = 7) and MRI (n = 6). The tumors 26–83 mm in diameter (mean, 44 mm) were located in the head (n = 4) or body (n = 3) of the pancreas. They were demonstrated as lower attenuation areas relative to the adjacent pancreas on CT images obtained in both pancreatic and portal vein phases (n = 7) with a well-defined smooth margin (n = 5). They were demonstrated as hypointense areas relative to the pancreas on T2-weighted images (n = 4) and T2*-weighted images (n = 4) and diffusion-weighted images (n = 3). They contained hemosiderin deposits on histology (n = 7). Conclusions: Undifferentiated carcinoma with osteoclast-like giant cells of the pancreas might be present as low attenuation areas with a well-defined smooth margin on CT images obtained in pancreatic and portal vein phases, and hypointense areas on T2-, T2*-, and diffusion-weighted images caused by hemosiderin deposits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of navigator-gated and breath-held image acquisition techniques for multi-echo quantitative dixon imaging of the liver in children and young adults

Purpose: Acquired over a breath hold, multi-echo Dixon (mDixon) magnetic resonance imaging (MRI) of the liver can be used to quantify proton density fat fraction (PDFF) and iron-related signal decay. However, young, obese, and co-morbid patients may have limited breath holding capacity and could benefit from a motion-robust mDixon acquisition. The purpose of this study was to compare hepatic PDFF and R2* values between navigator-gated and breath-held mDixon MRI acquisition techniques in children and young adults with suspected liver disease. Materials and methods: This retrospective study was institutional review board-approved with a waiver of informed consent. Patients who underwent liver MRI with breath-held and navigator-gated mDixon sequences between January 2017 and July 2018 were included. One reviewer, blinded to sequence, measured PDFF and R2* on four images from each sequence. Another blinded reviewer graded respiratory motion (5-point Likert scale). Pearson correlation (r), Lin’s concordance coefficients (r{sub c}), and Bland–Altman analyses were used to assess agreement between techniques. Frequency of clinically limiting motion (score ≥ 3) was compared with Fisher’s exact test. Results: Forty-two patients were included (15 female, 27 male; mean age: 15.7 ± 4.6 years). Mean PDFF and R2* were 16.6 ± 13.1% and 29.3 ± 4.7 s{sup −1} (breath-held) versus 17.0 ± 13.2% and 29.6 ± 5.2 s{sup −1} (navigator-gated). PDFF agreed almost perfectly between sequences (r{sub c} = 0.997, 95% CI 0.994–0.998; mean bias: 0.3%; 95% limits of agreement: − 2.4 to +1.7%), while R2* values correlated very strongly but with poor agreement (r = 0.837, r{sub c} = 0.832, 95% CI 0.716–0.910). Navigator-gated images exhibited significantly higher frequency of clinically limiting respiratory motion (88% vs. 48%, p = 0.0001). Conclusion: Despite greater respiratory motion artifact, a free-breathing navigator-gated mDixon sequence produces PDFF values with almost perfect agreement to a breath-held sequence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) versus endoscopic retrograde cholangiopancreatography (ERCP) in the pediatric population: a clinical effectiveness study

Purpose: To determine the diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) for detecting biliary and pancreatic abnormalities in a pediatric population, using endoscopic retrograde cholangiopancreatography (ERCP) as the reference standard. Materials and methods: Institutional review board approval with a waiver of informed consent was obtained for this retrospective investigation. Records from the Cincinnati Children’s Hospital Medical Center, Division of Gastroenterology and Department of Radiology were used to identify patients aged ≤ 18 years who had undergone both ERCP and MRCP within a 4-week interval between January 2013 and May 2017. Biliary and pancreatic duct findings were documented for each modality to determine the diagnostic performance of MRCP (with 95% confidence intervals), using ERCP as the reference standard. Results: 54 patients met inclusion criteria. Mean patient age at time of ERCP was 10.4 ± 4.9 years, and 25 (46%) were male. Mean interval between ERCP and MRCP was 11.2 ± 9.7 days. For detection of any abnormality (n = 99 ERCP findings), MRCP had a sensitivity of 76.8% (67.5–84.0%) and a positive predictive value (PPV) of 81.7% (72.7–88.3%). MRCP was 75.7% (59.9–86.6%) sensitive, with a PPV of 84.9% (69.1–93.4%) for biliary findings (n = 37) and 73.5% (59.7–83.8%) sensitive, with a PPV of 78.3% (64.4–87.7%) for pancreatic findings (n = 49). For pancreatobiliary abnormalities (n = 13), MRCP had a sensitivity of 92.3% (66.7–99.6%) and a PPV of 85.7% (60.1–97.5%). Conclusion: In clinical practice, MRCP is moderately sensitive for biliary and pancreatic abnormalities, with false-negative and false-positive examinations being relatively common.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interobserver agreement of computed tomography reporting standards for chronic pancreatitis

Aim: To assess the interobserver agreement of computed tomography (CT) reporting standards for chronic pancreatitis (CP). Subjects and methods: Retrospective analysis of CT of 47 patients (33 males and 11 females, age range 36 to 56 years) with CP who presented with abdominal pain (n = 41), steatorrhea (n = 37), and glucose intolerance (n = 31). The patients underwent CT study using a 16-multidetector CT scanner with a pancreatic protocol including a nonenhanced scan followed by pancreatic phase at 35 s and portal venous phase at 65 s after intravenous injection of nonionic contrast medium. Image analysis was performed by two radiologists according to reporting standards for CP. Results: There was excellent interobserver agreement (84.8 %) between the two reviewers in CT reporting standards for CP (K = 0.80, 95 % CI 0.75–0.85, P = 0.001). There was good interobserver agreement for pancreatic duct (PD) caliber (K = 0.71, 95 % CI 0.56–0.87, P = 0.001), PD contour (K = 0.76, 95 % CI 0.61–0.91, P = 0.001), PD stricture (K = 0.070, 95 % CI 0.53–0.88, P = 0.001), and distribution of findings (K = 0.69, 95 % CI 0.51–0.86, P = 0.001). There was excellent interobserver agreement for intraductal calculi (K = 0.84, 95 % CI 0.68–0.98, P = 0.001), pancreatic calcifications (K = 0.86, 95 % CI 0.84–0.98, P = 0.001), and pancreatic diameter (K = 0.87, 95 % CI 0.75–0.99, P = 0.001). Conclusion: CT reporting standards for CP is a reliable method for diagnosis of patients with CP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-weighted imaging as a part of PET/MR for small lesion detection in patients with primary abdominal and pelvic cancer, with or without TOF reconstruction technique

Objectives: To investigate the value of diffusion-weighted imaging (DWI) in detection of small lesions (≤ 10 mm) in patients with primary abdominal and pelvic cancer in hybrid PET/MR with or without time-of-flight (TOF) technique. Materials and methods: Twenty patients (11 females and 9 males, mean age 67.23 ± 12.90 years) with histologically confirmed primary abdominal and pelvic cancer underwent hybrid PET/MR examination. A total of 64 small lesions were included in this study, which were divided into two groups (≤ 10 mm and 10–30 mm). Visual scores of small lesion detection ability were rated by five-point ordinal scale. The visual scores and detectability of small lesions on TOF PET image, noTOF PET image, and DWI sequences of hybrid PET/MR examination with or without TOF technique were analyzed. Logistic regression model was established for analysis in the value of DWI in hybrid PET/MR examination with or without TOF technique in detection of the small lesions between two groups. Results: The visual evaluation revealed the small lesion (≤ 10 mm) visual scores of DWI (mean ± SD: 4.23 ± 1.41), TOF PET image (mean ± SD: 4.14 ± 0.89), and noTOF PET image (mean ± SD: 2.68 ± 1.13);.and the visual scores of small lesions (10–30 mm) on DWI (mean ± SD: 4.98 ± 0.15), TOF PET image (mean ± SD: 4.57 ± 0.59), and noTOF PET image (mean ± SD: 3.98 ± 1.05). The visual scores of all small lesions on DWI were higher than that on TOF PET data and noTOF PET data in both two groups (**P < 0.01). The missed diagnosis rates of small FDG avid lesions (≤ 10 mm) of DWI and noTOF PET image were 9.1% and 9.1%, respectively. However, the TOF PET-based clinical diagnosis detected all small lesions (≤ 30 mm). DWI was of great importance in detection of small lesions (≤ 10 mm) in the absence of TOF technique in PET/MR examination (**P < 0.01). DWI’s effect on detection of small lesions(10-30 mm) has shown no difference between PET/MR examinations with TOF and without TOF techniques (P > 0.05). Conclusion: DWI has significant value in the detection of small lesions (≤ 10 mm) in hybrid PET/MR examination without TOF technique for patients with primary abdominal and pelvic cancer. However, it had less detection benefits in the small lesions (≤ 10 mm) in hybrid PET/MR examination with TOF PET image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

110 Patients with adenosquamous carcinomas of the pancreas (PASC): imaging differentiation of small (≤ 3 cm) versus large (> 3 cm) tumors

Objective: This study examined radiological imaging features of small (≤ 3 cm) and large (> 3 cm) adenosquamous carcinomas of the pancreas (PASC) lesions to better understand the morphology of these lesions. Methods: Images from 110 patients with pathologically proven PASC (80 males and 30 females, mean age: 62.6 years) were retrospectively reviewed. Two radiologists analyzed images and reached a consensus regarding the following features: location, shape, margins, presence of solid and necrotic components, rim enhancement, density/intensity during the portal venous phase, invasion of surrounding organs, vascular invasion, venous tumor thrombus formation, and enlarged lymph nodes. Differences in the imaging features between the two groups were evaluated with the Chi-square test or Fisher’s exact test. Results: There were 41 small PASC lesions (mean age: 60.59 years) and 69 large PASC lesions (63.74 years). Statistical analysis demonstrated significant differences in the location, shape, adjacent organ and vessel invasion, and venous tumor thrombus formation (P < 0.05). Small PASC lesions were more frequently detected in the pancreatic head and had an ovoid shape. There was no significant difference in the presence of solid and necrotic components (P = 0.090), including approximately 3/4 of the lesions with necrosis and 1/4 purely solid lesions, enlarged lymph nodes (P = 0.068) and other features. Conclusion: Regardless of the tumor size, 75% of PASC lesions present with central necrosis while 25% are purely solid. Small PASC lesions can be associated with lymph node metastasis at a relatively early stage. Large PASC lesions are likely to invade adjacent tissues and be associated with venous tumor thrombus formation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter arterial infusion for pancreatic cancer: a 10-year National Cancer Center experience in 115 patients and literature review

Purpose: To evaluate the efficacy and safety of transcatheter arterial infusion (TAI) for the treatment of pancreatic cancer in patients ineligible for or refractory to systemic chemotherapy. Materials and methods: The medical records of 115 consecutive patients (mean age, 58.9 years; 71 males) with documented pancreatic cancer ineligible for or refractory to systemic chemotherapy and underwent TAI between February 2007 and January 2017 were reviewed. Results: A total of 224 TAI sessions [mean, 1.9 (range 1–8)] were performed. Technical success rate was 100%. Disease control (i.e., complete response, partial response, and stable disease) was achieved in 72 (62.6%) patients. The median progression-free survival and median overall survival were 56 days and 147 days, respectively. Subgroup analysis revealed that disease control, progression-free survival, and overall survival were significantly improved in patients with an Eastern Cooperative Oncology Group score of ≤ 1 compared with those in patients with an Eastern Cooperative Oncology Group score of 2 (all p < 0.001) and in patients who received > 1 sessions of TAI compared with that in patients who received only 1 session of TAI (p = 0.012, < 0.001, and = 0.002, respectively). A major complication in the form of cerebral infarction occurred in 1 (0.9%) patient 1 day after the procedure. This patient was treated with conservative therapy and recovered without permanent adverse sequelae. No other major complications were observed. Conclusions: TAI may be effective and safe for the treatment of pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of spleen fat on MRI-proton density fat fraction arises from reconstruction of noise

Purpose: This study compares splenic proton density fat fraction (PDFF) measured using confounder-corrected chemical shift-encoded (CSE)-MRI to magnetic resonance spectroscopy (MRS) in human patients at 3T. Methods: This was a prospectively designed ancillary study to various previously described single-center studies performed in adults and children with known or suspected nonalcoholic fatty liver disease. Patients underwent magnitude-based MRI (MRI-M), complex-based MRI (MRI-C), high signal-to-noise variants (Hi-SNR MRI-M and Hi-SNR MRI-C), and MRS at 3T for spleen PDFF estimation. PDFF from CSE-MRI methods were compared to MRS-PDFF using Wilcoxon signed-rank tests. Demographics were summarized descriptively. Spearman’s rank correlations were computed pairwise between CSE-MRI methods. Individual patient measurements were plotted for qualitative assessment. A significance level of 0.05 was used. Results: Forty-seven patients (20 female, 27 male) including 12 adults (median 55 years old) and 35 children (median 12 years old). Median PDFF estimated by MRS, MRI-M, Hi-SNR MRI-M, MRI-C, and Hi-SNR MRI-C was 1.0, 2.3, 1.9, 2.2, and 2.0%. The four CSE-MRI methods estimated statistically significant higher spleen PDFF values compared to MRS (p < 0.0001 for all). Pairwise associations in spleen PDFF values measured by different CSE-MRI methods were weak, with the highest Spearman’s rank correlations being 0.295 between MRI-M and Hi-SNR MRI-M; none were significant after correction for multiple comparisons. No qualitative relationship was observed between PDFF measurements among the various methods. Conclusion: Overestimation of PDFF by CSE-MRI compared to MRS and poor agreement between related CSE-MRI methods suggest that non-zero PDFF values in human spleen are artifactual.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Embolization for Delayed Hemorrhage Caused by Blunt Splenic Trauma

Although the exact benefit of adjunctive splenic artery embolization (SAE) in the nonoperative management (NOM) of patients with blunt splenic trauma has been debated, the role of transcatheter embolization in delayed splenic hemorrhage is rarely addressed. The purpose of this study was to evaluate the effectiveness of SAE in the management of patients who presented at least 3 days after initial splenic trauma with delayed hemorrhage. During a 24-month period 4 patients (all male; ages 19-49 years) presented with acute onset of pain 5-70 days after blunt trauma to the left upper quadrant. Two had known splenic injuries that had been managed nonoperatively. All had computed axial tomography evidence of active splenic hemorrhage or false aneurysm on representation. All underwent successful SAE. Follow-up ranged from 28 to 370 days. These cases and a review of the literature indicate that SAE is safe and effective for NOM failure caused by delayed manifestations of splenic arterial injury.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transcholecystic Placement of an ePTFE/FEP-Covered Stent in the Common Bile Duct

We report the case of a 78-year-old male patient with obstructive jaundice due to a pancreatic head neoplasm. The patient's general condition did not permit an endoscopic approach and the presence of diffuse liver metastases prohibited hepatic puncture for percutaneous biliary drainage, therefore the transcolecystic transperitoneal approach was decided to be the safest decompression route. Through a gallbladder access, a Viabil-covered stent with a mesh extension was placed in the distal common bile duct, without complications. The patient died 8 months later without signs of stent dysfunction or necessity of reintervention. Transcholecystic transperitoneal access is a safe option when diffuse liver metastases prohibit the transhepatic approach, even in cases where placement of a covered stent is considered necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Traumatic Inferior Gluteal Artery Aneurysm Managed with Emergency Transcatheter Thrombin Injection

Pseudoaneurysms of the inferior gluteal artery (IGA) are rare and are often caused by trauma. Treatment options vary and include surgery, ultrasound-guided percutaneous thrombin injection, and endovascular procedures such as stent-graft placement, coil embolization, and glue injection. We report a 70-year-old male who presented to the hospital after a road accident with a posttraumatic pseudoaneurysm that was treated by endovascular thrombin embolization. To the best of our knowledge, this is the first reported case of inferior gluteal artery false aneurysm treated by this method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transient Encephalopathy from Angiographic Contrast: A Rare Complication in Neurointerventional Procedures

Neurotoxicity from contrast media used in angiography is a rare complication from these procedures. The infrequency with which it is encountered makes it a diagnostic challenge. We present the case of a 51-year-old male who, 30 min after successful angiography for treatment of a right carotid-ophthalmic fusiform aneurysm with a stent, developed psychomotor agitation, disorientation, and progressive left faciobrachial hemiparesis (4/5). An emergency nonenhanced CT showed marked cortical enhancement and edema in the right cerebral hemisphere. Cortical enhancement is thought to be secondary to contrast extravasation due to disruption of the blood-brain barrier. Angiography was performed immediately, without any pathologic findings. After this procedure there was an increase in the left faciobrachial hemiparesis (3/5), right gaze deviation, Gerstmann syndrome, and left anosognosia and left homonymous hemianopsia. Endovenous dexamethasone and mannitol were initiated. Twenty-four hours later an MRI showed no signs of acute infarct, just gyriform signal increase in the right cerebral hemisphere on FLAIR and a decrease in the edema observed before. The patient had progressive improvement of his neurological deficit. A control MRI done 5 days later was normal. The patient recovered completely and was discharged. This rare entity should be kept in mind but diagnosed only when all other causes have been ruled out, because more important and frequent causes, such as acute infarct, must be excluded promptly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broken Esophageal Stent Successfully Treated by Interventional Radiology Technique

Esophageal stent fractures occur quite rarely. A 61-year-old male patient was previously treated for rupture of benign stenosis, occurring after dilatation, by implanting an esophageal stent. However, a year after implantation, the patient suffered from dysphagia caused by the broken esophageal stent. He was treated with the interventional radiology technique, whereby a second implantation of the esophageal stent was carried out quite successfully.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Coarctation of the Distal Thoracic Aorta with a Supradiaphragmatic Origin of the Celiacomesenteric Trunk: An Anatomic and Etiologic Description

Stenosis of the distal thoracic aorta was found during an evaluation for incidentally detected hypertension in a 21-year-old male patient. A celiacomesenteric trunk originated from just above the coarctation site in the thorax, and the lower posterior intercostal arteries showed unusual low origins. Consideration of these anatomies suggests that the etiology of this case is congenital.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Always Contact a Vascular Interventional Specialist Before Amputating a Patient with Critical Limb Ischemia

Patients with severe critical limb ischemia (CLI) due to long tibial artery occlusions are often poor candidates for surgical revascularization and frequently end up with a lower limb amputation. Subintimal angioplasty (SA) offers a minimally invasive alternative for limb salvage in this severely compromised patient population. The objective of this study was to evaluate the results of SA in patients with CLI caused by long tibial occlusions who have no surgical options for revascularization and are facing amputation. We retrospectively reviewed all consecutive patients with CLI due to long tibial occlusions who were scheduled for amputation because they had no surgical options for revascularization and who were treated by SA. A total of 26 procedures in 25 patients (14 males; mean age, 70 {+-} 15 [SD] years) were evaluated. Technical success rate was 88% (23/26). There were four complications, which were treated conservatively. Finally, in 10 of 26 limbs, no amputation was needed. A major amputation was needed in 10 limbs (7 below-knee amputations and 3 above-knee amputations). Half of the major amputations took place within 3 months after the procedure. Cumulative freedom of major amputation after 12 months was 59% (SE = 11%). In six limbs, amputation was limited to a minor amputation. Seven patients (28%) died during follow-up. In conclusion, SA of the tibial arteries seem to be a valuable treatment option to prevent major amputation in patients with CLI who are facing amputation due to lack of surgical options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Term Effects of Transjugular Intrahepatic Shunt on Cardiac Function Assessed by Cardiac MRI: Preliminary Results

The purpose of this study was to assess short-term effects of transjugular intrahepatic shunt (TIPS) on cardiac function with cardiac magnetic resonance imaging (MRI) in patients with liver cirrhosis. Eleven patients (six males and five females) with intractable esophageal varices or refractory ascites were imaged with MRI at 1.5 T prior to, within 24 h after, and 4-6 months after TIPS creation (n = 5). Invasive pressures were registered during TIPS creation. MRI consisted of a stack of contiguous slices as well as phase contrast images at all four valve planes and perpendicular to the portal vein. Imaging data were analyzed through time-volume curves and first derivatives. The portoatrial pressure gradient decreased from 19.8 {+-} 2.3 to 6.6 {+-} 2.3, accompanied by a nearly two fold increase in central pressures and pulmonary capillary wedge pressure immediately after TIPS creation. Left and right end diastolic volumes and stroke volumes increased by 11, 13, and 24%, respectively (p < 0.001), but dropped back to baseline at follow-up. End systolic volumes remained unchanged. E/A ratios remained within normal range. During follow-up the left ventricular mass was larger than baseline values in all patients, with an average increase of 7.9 g (p < 0.001). In conclusion, the increased volume load shunted to the heart after TIPS creation transiently exceeded the preload reserve of the right and left ventricle, leading to significantly increased pulmonary wedge pressures and persistent enlargement of the left and right atria. Normalization of cardiac dimensions was observed after months together with mild left ventricular hypertrophy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertebral Arteriovenous Fistula Presenting as Cervical Myelopathy: A Rapid Recovery with Balloon Embolization

A 24-year-old male presented with progressive cervical myelopathy of 2 months' duration. Magnetic resonance imaging of the cervical spine and angiography revealed a large arteriovenous fistula arising from the left vertebral artery. The present case highlights the clinical features and dramatic recovery following endovascular balloon occlusion of a giant cervical arteriovenous fistula.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MDCT Versus MRI Assessment of Tumor Response After Transarterial Chemoembolization for the Treatment of Hepatocellular Carcinoma

The purpose of this study was to compare the ability of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) to evaluate treatment results after transarterial chemoembolization (TACE), with a special focus on the influence of Lipiodol on calculation of tumor necrosis according to EASL criteria. A total of 115 nodules in 20 patients (17 males, 3 females; 69.5 {+-} 9.35 years) with biopsy-proven hepatocellular carcinoma were treated with TACE. Embolization was performed using a doxorubicin-Lipiodol emulsion (group I) or DC Beads loaded with doxorubicin (group II). Follow-up included triphasic contrast-enhanced 64-row MDCT (collimation, 0.625 mm; slice, 3 mm; contrast bolus, 120 ml iomeprol; delay by bolus trigger) and contrast-enhanced MRI (T1 native, T2 native; five dynamic contrast-enhanced phases; 0.1 mmol/kg body weight gadolinium-DTPA; slice thickness, 4 mm). Residual tumor and the extent of tumor necrosis were evaluated according to EASL. Contrast enhancement within tumor lesions was suspected to represent vital tumor. In the Lipiodol-based TACE protocol, MDCT underestimated residual viable tumor compared to MRI, due to Lipiodol artifacts (23.2% vs 47.7% after first, 11.9% vs 31.2% after second, and 11.4% vs 23.7% after third TACE; p = 0.0014, p < 0.001, and p < 0.001, respectively). In contrast to MDCT, MRI was completely free of any artifacts caused by Lipiodol. In the DC Bead-based Lipiodol-free TACE protocol, MRI and CT showed similar residual tumor and rating of treatment results (46.4% vs 41.2%, 31.9 vs 26.8%, and 26.0% vs 25.6%; n.s.). In conclusion, MRI is superior to MDCT for detection of viable tumor residuals after Lipiodol-based TACE. Since viable tumor tissue is superimposed by Lipiodol artifacts in MDCT, MRI is mandatory for reliable decision-making during follow-up after Lipiodol-based TACE protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗