Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverse Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

SU-D-18C-01: A Novel 4D-MRI Technology Based On K-Space Retrospective Sorting

Purpose: Current 4D-MRI techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of an entirely new framework of 4D-MRI based on k-space retrospective sorting. Methods: An important challenge of the proposed technique is to determine the number of repeated scans(NR) required to obtain sufficient k-space data for 4D-MRI. To do that, simulations using 29 cancer patients' respiratory profiles were performed to derive the relationship between data acquisition completeness(Cp) and NR, also relationship between NR(Cp=95%) and the following factors: total slice(NS), respiratory phase bin length(Lb), frame rate(fr), resolution(R) and image acquisition starting-phase(P0). To evaluate our technique, a computer simulation study on a 4D digital human phantom (XCAT) were conducted with regular breathing (fr=0.5Hz; R=256×256). A 2D echo planer imaging(EPI) MRI sequence were assumed to acquire raw k-space data, with respiratory signal and acquisition time for each k-space data line recorded simultaneously. K-space data was re-sorted based on respiratory phases. To evaluate 4D-MRI image quality, tumor trajectories were measured and compared with the input signal. Mean relative amplitude difference(D) and cross-correlation coefficient(CC) are calculated. Finally, phase-sharing sliding window technique was applied to investigate the feasibility of generating ultra-fast 4D-MRI. Result: Cp increased with NR(Cp=100*[1-exp(-0.19*NR)], when NS=30, Lb=100%/6). NR(Cp=95%) was inversely-proportional to Lb (r=0.97), but independent of other factors. 4D-MRI on XCAT demonstrated highly accurate motion information (D=0.67%, CC=0.996) with much less artifacts than those on image-based sorting 4D-MRI. Ultra-fast 4D-MRI with an apparent temporal resolution of 10 frames/second was reconstructed using the phase-sharing sliding window technique. Conclusions: A novel 4D-MRI technology based on k-space sorting has been successfully developed and evaluated on the digital phantom. Framework established can be applied to a variety of MR sequences, showing great promises to develop the optimal 4D-MRI technique for many radiation therapy applications. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

Far-field thermal imaging below diffraction limit

Non-uniform self-heating and temperature hotspots are major concerns compromising the performance and reliability of submicron electronic and optoelectronic devices. At deep submicron scales where effects such as contact-related artifacts and diffraction limits accurate measurements of temperature hotspots, non-contact thermal characterization can be extremely valuable. In this work, we use a Bayesian optimization framework with generalized Gaussian Markov random field (GGMRF) prior model to obtain accurate full-field temperature distribution of self-heated metal interconnects from their thermoreflectance thermal images (TRI) with spatial resolution 2.5 times below Rayleigh limit for 530nm illumination. Finite element simulations along with TRI experimental data were used to characterize the point spread function of the optical imaging system. In addition, unlike iterative reconstruction algorithms that use ad hoc regularization parameters in their prior models to obtain the best quality image, we used numerical experiments and finite element modeling to estimate the regularization parameter for solving a real experimental inverse problem.

42 ENGINEERING↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Spin-orbit-proximitized ferromagnetic metal by monolayer transition metal dichalcogenide: Atlas of spectral functions, spin textures, and spin-orbit torques in Co/MoSe 2 , Co/WSe 2 and Co/TaSe 2 heterostructures

In this work, the heterostructures composed of an ultrathin ferromagnetic metal (FM) and a material hosting strong spin-orbit (SO) coupling are the principal resource for SO torque and spin-to-charge conversion nonequilibrium effects in spintronics. The key quantity in theoretical description of these effects is nonequilibrium spin density, which can appear on any monolayer of the heterostructure through which the current is flowing as long as the monolayer bands are affected by the native or proximity induced SO coupling. Here we demonstrate how hybridization of wave functions of Co layer and a monolayer of transition metal dichalcogenides (TMDs)—such as semiconducting MoSe 2 and WSe 2 or metallic TaSe 2 —can lead to dramatic transmutation of electronic and spin structure of Co within some distance away from its interface with TMD, when compared to the bulk of Co or its surface in contact with a vacuum. This is due to proximity induced SO splitting of Co bands encoded in the spectral functions and spin textures on its monolayers, which we obtain using noncollinear density functional theory (ncDFT) combined with equilibrium Green function (GF) calculations. In fact, SO splitting is present due to structural inversion asymmetry of the bilayer—i.e., just the presence of the interface—even if SO coupling within TMD monolayer is artificially switched off in ncDFT calculations. However, switching it on makes the effects associated with proximity SO coupling within Co layer about five times larger. Injecting spin-unpolarized charge current through SO-proximitized monolayers of Co generates nonequilibrium spin density over them, so that its cross product with the magnetization of Co determines SO torque. The SO torque computed via first-principles quantum transport methodology, which combines ncDFT with nonequilibrium GF calculations, can be used as the screening parameter to identify optimal combination of materials and their interfaces for applications in spintronics. In particular, we identify heterostructure two-monolayer-Co/monolayer-WSe 2 as the most optimal one, at least in the clean limit.

2-dimensional systems↗

SU-E-T-814: Whole Breast Irradiation with Two Different Intensity Modulation Radiotherapy Techniques

Purpose: Breast cancer now mainly received forward intensity modulation radiotherapy (f-IMRT) and inverse IMRT (i-IMRT). The purpose of this study was to observe the differences of two treatment methods. Methods: 10 patients after left breast-conserving surgery were selected to receive radiotherapy. For each patient, two treatment plans (f-IMRT and i-IMRT) were designed. For f-IMRT plans, two tangent beams were designed to the target, and in each tangent orientation two or three segment beams were designed to reduced high dose region in the target and the dose of lung received. For i-IMRT plans, two tangent beams were designed to the target and the treatment planning system optimize the dose according to the optimization parameters. For each plan 50Gy was prescribed. Results: In f-IMRT and i-IMRT plans, the average target conformal index (CI) were (0.67±0.06) and (0.66±0.06), (P>0.05); average homogeneity index (HI) were (28.2±6.0)% and (26.1±6.8)%, (P>0.05); volume of left lung received 20Gy (V20) were (18.7±3.3)% and (17.0±2.8)%, (P<0.05), V30 were (15.5±3.0)% and (14.0±2.6)%, (P<0.05); V30 of heart were (4.1±3.1)% and (3.5±2.5)%, (P>0.05); Monitor Unit (MU) were (262±5)MU and (308±14)MU. Conclusion: Compared with i-IMRT plan, for breast cancer, the differences of CI and HI were not significant. Because of fewer MU, f-IMRT plan could reduce the machine abrasion and treatment time, but dose of normal tissue received were higher significantly than i-IMRT plan.

60 APPLIED LIFE SCIENCES↗

Deep Learning and Natural Language Processing for Accelerated Inverse Design of Optical Metamaterials

Optical metamaterial device design has enjoyed a long track of success over the past 50 years leading to the manipulation of light over a wide range of wavelengths spanning the ultraviolet to the far infrared. The manipulation of light over such wavelengths has already led to many technological advancements such as the design of selective radiative absorbers for solar energy, daytime passive cooling using deep space, and optical invisibility cloaks for defense applications. Further disruptive advancements in energy, defense, computing, and biomedical fields could be enabled or enhanced by future optical metamaterial devices. These technologies could lead to increased energy efficiency and hence reduced national primary energy consumption, cheap long duration energy storage, and next generation solid-state heat engines. But historically the methods to invent and develop all of these devices have been time- consuming and based mostly on intuition and iteration. Finding an optimal design can take years.

36 MATERIALS SCIENCE↗

Deep Learning and Natural Language Processing for Accelerated Inverse Design of Optical Metamaterials

Optical metamaterial device design has enjoyed a long track of success over the past 50 years leading to the manipulation of light over a wide range of wavelengths spanning the ultraviolet to the far infrared. The manipulation of light over such wavelengths has already led to many technological advancements such as the design of selective radiative absorbers for solar energy, daytime passive cooling using deep space, and optical invisibility cloaks for defense applications. Further disruptive advancements in energy, defense, computing, and biomedical fields could be enabled or enhanced by future optical metamaterial devices. These technologies could lead to increased energy efficiency and hence reduced national primary energy consumption, cheap long duration energy storage, and next generation solid-state heat engines. But historically the methods to invent and develop all of these devices have been time- consuming and based mostly on intuition and iteration. Finding an optimal design can take years. In this project we developed a machine learning-based algorithm capable of automatically generating device designs to produce desired optical properties, reducing the design cycle life in certain situations to be almost instantaneous.

36 MATERIALS SCIENCE↗

Dynamics of inverse metal oxides on metal catalysts using spectro-kinetics: reversible Brønsted acid site formation and irreversible reduction

Brønsted acid sites (BASs) in inverse catalysts are vital for the selective hydrogenolysis of polyols, specifically cleaving secondary C–O bonds. These BASs form dynamically in situ in an H 2 environment. While H 2 enables rapid BAS generation on short timescales, it reduces the catalyst at prolonged exposures. The active center for BAS generation, the kinetics of BAS formation, its reverse decomposition, and the irreversible oxide reduction have lacked direct experimental evidence. Here, aided by advanced spectro-kinetic studies, we identify trimeric W 3 O x sites on Pt as the active centers for BAS generation, whereas isolated WO x species on SiO 2 act merely as spectator species, demonstrated using an inverse WO x /Pt catalyst as a representative system. A detailed kinetic profile capturing the dynamics of W 3 O x sites on Pt is also established. The rate constant for BAS formation is two orders of magnitude higher than for its decomposition, which is one order of magnitude faster than the irreversible site reduction. Co-fed H 2 O suppresses the site reduction by ∼50%. Furthermore, the H 2 partial pressure plays an important role. While lower gas-phase H 2 partial pressure does not influence the reversible BAS formation, it can significantly (∼3×) suppress catalyst reduction. Finally, these findings offer critical insights into optimizing reaction conditions through periodic H 2 pulsing, enhancing catalyst stability and performance in hydrogenolysis reactions.

Sourav, Sagar [Indian Inst. of Technology (IIT), M↗

Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI{sub 100} = 1.09 and CI{sub 50} = 4.07) were better than VMAT conformity indices (CI{sub 100} = 1.30 and CI{sub 50} = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI{sub 100} and CI{sub 50} conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI{sub 100} and CI{sub 50} conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. Conclusions: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.

60 APPLIED LIFE SCIENCES↗

A laser inverse Compton scattering diagnostic to study runaway electron dynamics during tokamak disruptions

Both technical and simulation progress has been made toward implementing a laser inverse Compton scattering diagnostic on the DIII-D tokamak. This is a novel diagnostic which uses a short (sub-ns) pulse laser together with a fast (sub-ns) gated x-ray detector to measure relativistic electrons inside a tokamak plasma. The study of these relativistic electrons is important to make sure they can be removed from any tokamak-based power reactor, as they could damage vessel walls and cooling lines. This diagnostic is completely new for magnetic fusion research and has never been implemented before on a tokamak. It is found that good signals and radial profiles could be obtained with an optimized high-energy (7 Joule) laser. Using a standard off-the-shelf Nd:YAG (0.7 Joule) laser would give some signals above the noise but no ability to measure the relativistic electron radial profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated Planning of Tangential Breast Intensity-Modulated Radiotherapy Using Heuristic Optimization

Purpose: To present an automated technique for two-field tangential breast intensity-modulated radiotherapy (IMRT) treatment planning. Method and Materials: A total of 158 planned patients with Stage 0, I, and II breast cancer treated using whole-breast IMRT were retrospectively replanned using automated treatment planning tools. The tools developed are integrated into the existing clinical treatment planning system (Pinnacle{sup 3}) and are designed to perform the manual volume delineation, beam placement, and IMRT treatment planning steps carried out by the treatment planning radiation therapist. The automated algorithm, using only the radio-opaque markers placed at CT simulation as inputs, optimizes the tangential beam parameters to geometrically minimize the amount of lung and heart treated while covering the whole-breast volume. The IMRT parameters are optimized according to the automatically delineated whole-breast volume. Results: The mean time to generate a complete treatment plan was 6 min, 50 s {+-} 1 min 12 s. For the automated plans, 157 of 158 plans (99%) were deemed clinically acceptable, and 138 of 158 plans (87%) were deemed clinically improved or equal to the corresponding clinical plan when reviewed in a randomized, double-blinded study by one experienced breast radiation oncologist. In addition, overall the automated plans were dosimetrically equivalent to the clinical plans when scored for target coverage and lung and heart doses. Conclusion: We have developed robust and efficient automated tools for fully inversed planned tangential breast IMRT planning that can be readily integrated into clinical practice. The tools produce clinically acceptable plans using only the common anatomic landmarks from the CT simulation process as an input. We anticipate the tools will improve patient access to high-quality IMRT treatment by simplifying the planning process and will reduce the effort and cost of incorporating more advanced planning into clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Bayesian statistical approach to inferring particle dynamics from in-situ pump POC and chloropigment data from the Mediterranean Sea

Concentrations of chloropigments and particulate organic carbon (POC) in large-volume in-situ pump samples from the Mediterranean Sea were used to estimate rate constants of processes that control the fate of particles, and specifically chloropigments, in the water column. In this paper we introduce a Bayesian statistical inversion method that combines the data with a new box model and has the capacity to infer rate constants for POC respiration/dissolution, chlorophyll and pheopigment degradation, and particle aggregation and disaggregation. We use first-order kinetics to model disaggregation, and use both first-order and second-order kinetics to model aggregation. Using these methods, the estimated small-particle (1–70 μm) POC respiration rate constant was 2.44 -1.00 +1.69 yr -1 (0.41 yr). The estimated disaggregation and second-order aggregation rate constants were 85.6 -36.4 +63.4 yr -1 (1.17×10 -2 yr) and 2.78 -1.17 +2.01 μM -1 yr -1 , respectively. Using the optimal rate constants and the corresponding particle concentrations, disaggregation is ~4.2 times faster than the small-size POC dissolution rate, which indicates that disaggregation is a dominant processes at the time of sampling. More importantly, by comparing our results with those of previous studies, we conclude that sampling methods have less influence than tracers themselves on inferring particle dynamic rate constants. We previously introduced a somewhat similar approach to modeling SV sediment trap data, but large volume pumps are a much more common sample collection method in oceanographic surveys than SV sediment traps, and thus our new model should have a wider applicability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Kill Switch Toxins in Plant-Beneficial Pseudomonas fluorescens Reveals Drivers of Lethality, Stability, and Escape

Kill switches provide a biocontainment strategy in which unwanted growth of an engineered microorganism is prevented by expression of a toxin gene. A major challenge in kill switch engineering is balancing evolutionary stability with robust cell killing activity in application relevant host strains. Understanding host-specific containment dynamics and modes of failure helps to develop potent yet stable kill switches. To guide the design of robust kill switches in the agriculturally relevant strain Pseudomonas fluorescens SBW25, we present a comparison of lethality, stability, and genetic escape of eight different toxic effectors in the presence of their cognate inactivators (i.e., toxin–antitoxin modules, polymorphic exotoxin–immunity systems, restriction endonuclease–methyltransferase pair). We find that cell killing capacity and evolutionary stability are inversely correlated and dependent on the level of protection provided by the inactivator gene. Decreasing the proteolytic stability of the inactivator protein can increase cell killing capacity, but at the cost of long-term circuit stability. By comparing toxins within the same genetic context, we determine that modes of genetic escape increase with circuit complexity and are driven by toxin activity, the protective capacity of the inactivator, and the presence of mutation-prone sequences within the circuit. Here, the results of our study reveal that circuit complexity, toxin choice, inactivator stability, and DNA sequence design are powerful drivers of kill switch stability and valuable targets for optimization of biocontainment systems.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Regression for Radioactive Source Detection

Detection of radioactive sources is an important capability that led to the deployment of networks for detecting and localizing low-level, hazardous radiation sources. It is generally expected that such networks outperform the individual detectors by intelligently fusing information from several dispersed sensors. In this paper, we develop a network detection method that uses the slope of a linear regression fit as a test statistic for detecting a point radioactive source within a field of detectors. In our regression model, we compute a least-squared linear fit between the average radiation counts at the detectors and the inverse-squared distances of known detector locations to an estimated source location. We show that the slope of this regression fit is an estimate of the source intensity and can be used as a threshold for source detection purposes. We compare performance of our proposed detection method with that of a fusion-based Sequential Probability Ratio Test (SPRT) method. For performance analyses, two datasets from the Domestic Nuclear Detection Ofces Intelligence Radiation Sensors Systems (IRSS) outdoor tests are used. Each of these tests consists of several runs of a single radioactive source moving in and out of a detector network. We present receiver operating characteristic (ROC) curves and optimal threshold values for the performance each detection method, and determine that our detection method using linear regression fit has slightly better overall performance than SPRT method.

Cordone, G.↗

Quantifying methane emissions from natural gas production in north-eastern Pennsylvania

Natural gas infrastructure releases methane (CH 4 ), a potent greenhouse gas, into the atmosphere. The estimated emission rate associated with the production and transportation of natural gas is uncertain, hindering our understanding of its greenhouse footprint. This study presents a new application of inverse methodology for estimating regional emission rates from natural gas production and gathering facilities in north-eastern Pennsylvania. An inventory of CH 4 emissions was compiled for major sources in Pennsylvania. This inventory served as input emission data for the Weather Research and Forecasting model with chemistry enabled (WRF-Chem), and atmospheric CH 4 mole fraction fields were generated at 3 km resolution. Simulated atmospheric CH 4 enhancements from WRF-Chem were compared to observations obtained from a 3-week flight campaign in May 2015. Modelled enhancements from sources not associated with upstream natural gas processes were assumed constant and known and therefore removed from the optimization procedure, creating a set of observed enhancements from natural gas only. Simulated emission rates from unconventional production were then adjusted to minimize the mismatch between aircraft observations and model-simulated mole fractions for 10 flights. To evaluate the method, an aircraft mass balance calculation was performed for four flights where conditions permitted its use. Using the model optimization approach, the weighted mean emission rate from unconventional natural gas production and gathering facilities in north-eastern Pennsylvania approach is found to be 0.36 % of total gas production, with a 2 σ confidence interval between 0.27 and 0.45 % of production. Similarly, the mean emission estimates using the aircraft mass balance approach are calculated to be 0.40 % of regional natural gas production, with a 2 σ confidence interval between 0.08 and 0.72 % of production. Furthermore these emission rates as a percent of production are lower than rates found in any other basin using a top-down methodology, and may be indicative of some characteristics of the basin that make sources from the north-eastern Marcellus region unique.

03 NATURAL GAS↗

Demonstration of MgCr 2– x Mn x O 4 Spinel Oxide Cathodes in High-Voltage Mg Batteries

Solid-solution oxide spinels with high redox voltages and facile Mg 2+ mobility have been identified as promising candidates for practical, high-voltage cathodes in Mg batteries. In this work, we discuss the development of MgCr 2-x Mn x O 4 [x = 0.5, 1, 1.2] solid-solution spinel oxides as a cathode material and their electrochemical performance paired with an Mg anode in a full cell. This work presents the first demonstration of full cells with these materials. Mg-Cr-Mn spinel oxides with varying Cr and Mn contents were synthesized using alternative synthetic routes for optimal electrochemical performance. High-resolution synchrotron powder X-ray diffraction (PXRD), solid-state nuclear magnetic resonance (NMR) spectroscopy, and electron microscopy showed that these different synthetic routes resulted in changes in structures and particle morphologies, which in turn affect the electrochemical performance. Particularly, the urea coprecipitation synthetic route resulted in high-surface-area particles that enabled lower overpotentials and increased discharge capacity. The high surface area also resulted in expedited structural degradation caused by the irreversible migration of Mg 2+ into normally vacant 16c sites in the spinel lattice. This structural degradation was lessened by using a hydrosauna-urea synthesis method, which decreased the Mg/Mn inversion ratio while retaining high-surface-area particles with good cycling performance. Furthermore, our findings highlight the necessity for high surface area or nanostructured spinel oxide cathodes with minimized Mg-Mn inversion to enable spinel oxide cathodes in Mg full cells.

Mg anode↗