Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Characterizing the Performance of Fission Chambers for Local Neutron Flux and Spectrum Measurement

Three fission chambers were tested at The Ohio State University Research Reactor (OSURR) to evaluate fission chambers for neutron flux and spectrum measurements. Two of the fission chambers are commercial Photonis CFUR43 fission chambers—one utilizing highly enriched uranium-235 fissile deposits for thermal neutron detection and the other with highly depleted uranium-238 for fast neutron detection. This experiment was also performed in collaboration with French Alternative Energies and Atomic Energy Commission (CEA) with CEA suppling a uranium-235 loaded fission chamber built from the Photonis CFPR CE8/9 kit. The fission chambers were irradiated in a movable 6.5 inch dry tube at reactor powers of 50 kW, 200 kW, and 450 kW at ambient temperature and at 350°C. While all sensors demonstrated good linear sensitivity to reactor power, a leakage current of 6 nA was measured for the CFUR43 detectors. Additionally, the measured signal ratios of the two CFUR43 detectors did not match the theoretical values and are subject to further investigation on individual signal contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Approach for Evaluating Detector Systematics in the MicroBooNE LArTPC

One of the primary challenges in current and future precision neutrino experiments using liquid argon time projection chambers (LArTPCs) is understanding detector effects and quantifying the associated systematic uncertainties. MicroBooNE has pioneered the evaluation of detector-related systematic uncertainties for such experiments. This note presents a novel technique for assessing detector systematics based on low-level comparisons between data and simulation. The method can be used to better understand detector-related uncertainties while remaining agnostic to the details of the detector model in simulation. We believe similar approaches could be applied to future LArTPC experiments, including SBN and DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

24.1.3.4 Upgraded Fixed Energy Response Function Analysis with Multiple Efficiencies (FRAM) Software for U/Pu/MOX Mass Measurements

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr 3 ) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-cone x-ray imaging Bragg crystal spectrometer

Embodiments provide a multi-cone X-ray imaging Bragg crystal spectrometer for spectroscopy of small x-ray sources with a well-defined spectral resolution. The spectrometer includes a glass substrate machined to a multi-cone form; and a thin crystal slab attached to the glass substrate, whereby the multi-cone X-ray imaging Bragg crystal spectrometer provides rotational symmetry of a ray pattern, providing for accurate imaging, for each wavelength in the spectral range of interest. One or more embodiments include a streak camera and/or a gated strip detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Irradiation Testing of Nuclear Flux Sensors - Presentation for 2021 ASI Annual Webinar

This power point presentation is a summary of the work produced in FY2021 under the Irradiation Testing of Neutron Flux Sensors project funded by DOE's Advanced Sensor Initiative, and the outlook for FY22. The objective of this portion of the ASI program is to "Test and demonstrate in-pile instrumentation in conditions similar to those expected to be seen in service, i.e., the conditions they would see in either in irradiation experiments supporting advanced reactors, or ultimately, in advanced reactors themselves". The presentation describes how neutron flux sensors were tested in four INL reactors plus Idaho State University's research reactor during FY2021, and the results obtained from these tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation detector using a graphene amplifier layer

A radiation field is detected or imaged using one or more junction devices in which a two-dimensional conductor layer is capacitively coupled to a semiconductor absorber layer. In the junction devices, pixel-level amplification and read-out are accomplished through the photogating of the devices by absorption within the absorber layer while it is in a state of deep depletion. When the two-dimensional conductor is graphene, we refer to a device operating in that manner as a deeply depleted graphene-oxide-semiconductor (D 2 GOS) detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron and photon performance measurements with the ATLAS detector using the 2015–2017 LHC proton-proton collision data

This paper describes the reconstruction of electrons and photons with the ATLAS detector, as employed for measurements and searches exploiting the complete LHC Run 2 dataset. An improved energy clustering algorithm is introduced, and its implications for the measurement and identification of electrons and photons are discussed in detail. Corrections and calibrations that affect performance, including energy calibration, identification and isolation efficiencies, and the measurement of the charge of reconstructed electron candidates are determined using up to 81 fb -1 of proton-proton collision data collected at $\sqrt{s}=$ 13 TeV between 2015 and 2017.

47 OTHER INSTRUMENTATION↗

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNEWS 2.0: a next-generation supernova early warning system for multi-messenger astronomy

The next core-collapse supernova in the Milky Way or its satellites will represent a once-in-a-generation opportunity to obtain detailed information about the explosion of a star and provide significant scientific insight for a variety of fields because of the extreme conditions found within. Supernovae in our galaxy are not only rare on a human timescale but also happen at unscheduled times, so it is crucial to be ready and use all available instruments to capture all possible information from the event. The first indication of a potential stellar explosion will be the arrival of a bright burst of neutrinos. Its observation by multiple detectors worldwide can provide an early warning for the subsequent electromagnetic fireworks, as well as signal to other detectors with significant backgrounds so they can store their recent data. The supernova early warning system (SNEWS) has been operating as a simple coincidence between neutrino experiments in automated mode since 2005. In the current era of multi-messenger astronomy there are new opportunities for SNEWS to optimize sensitivity to science from the next galactic supernova beyond the simple early alert. This document is the product of a workshop in June 2019 towards design of SNEWS 2.0, an upgraded SNEWS with enhanced capabilities exploiting the unique advantages of prompt neutrino detection to maximize the science gained from such a valuable event.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rydberg-atom-based single-photon detection for haloscope axion searches

We propose a Rydberg-atom-based single-photon detector for signal readout in dark matter haloscope experiments between 40 μ eV and 200 μ eV (10 GHz and 50 GHz). At these frequencies, standard haloscope readout using linear amplifiers is limited by quantum measurement noise, which can be avoided by using a single-photon detector. Our single-photon detection scheme can offer scan rate enhancements up to a factor of 10 4 over traditional linear amplifier readout, and is compatible with many different haloscope cavities. We identify multiple haloscope designs that could use our Rydberg-atom-based single-photon detector to search for QCD axions with masses above 40 μ eV (10 GHz), currently a minimally explored parameter space. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and novel application of power over fiber for electronics in a harsh environment

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at ∼ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer optical power. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency (∼ 51%), and superior isolation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

The nylon balloon for xenon loaded liquid scintillator in KamLAND-Zen 800 neutrinoless double-beta decay search experiment

The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of 136 Xe by using 136 Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spallation products and 8B solar neutrinos. Indeed these events could contribute to the total counts in the region of interest around the Q-value of the double-beta decay of 136 Xe. In this paper, we present an overview of the IB and describe the various steps of its commissioning minimizing the radioactive contaminations, from the material selection, to the fabrication of the balloon and its installation inside the KamLAND detector. Finally, we show the impact of the IB on the KamLAND background as measured by the KamLAND detector itself.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗