Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

A Bayesian Learning Approach to Wireless Outdoor Heatmap Construction using Deep Gaussian Process

We present a novel Bayesian learning approach to outdoor radio heatmap construction utilizing deep Gaussian process (GP). The proposed approach employs a two-layer hierarchy which consists of two cascaded Gaussian processes that are capable of modeling more complex input-output relations than standard single-layer Gaussian processes. Since deriving the exact model likelihood is challenging, a lower bound is optimized instead so that gradient descent-based methods can be performed to find out the optimal model parameters. Typically, inducing points are used in GPs to facilitate low-rank approximation of covariance (kernel) matrices for computation speedup. However, the inaccuracy induced by inducing points can accumulate when stacking multiple layers of GP which may hinder the performance of deep GP. Moreover, since inducing points need to be learned, having them at all layers of deep GP also incurs computational burden. To overcome the above challenges, in contrast to the canonical deep GP model, we use a modified architecture where a full standard GP resides in the first layer and inducing points are only introduced for the second layer. This modified architecture strikes a balance between model accuracy and training complexity. In the proposed model, the noise parameter of the first GP layer is also eliminated to improve the training efficiency as the noise parameter at the output of the second layer suffices to model the uncertainty in the output. The proposed approach is evaluated on real-world datasets, in the form of location-Received Signal Strength (RSS) pairs, collected from the Platform for Open Wireless Data-driven Experimental Research (POWDER) located at the campus of the University of Utah. Experiment results show that the proposed approach can achieve smaller prediction errors on various training and testing data configurations than DNN-based and GP-based methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-driven ionization mechanisms of aluminum for single particle aerosol mass spectrometry

Single particle aerosol mass spectrometry (SPAMS), an analytical technique for measuring the size and composition of individual micron-scale particles, is capable of analyzing atmospheric pollutants and bioaerosols much more efficiently and with more detail than conventional methods which require the collection of particles onto filters for analysis in the laboratory. Despite SPAMS’ demonstrated capabilities, the primary mechanisms of ionization are not fully understood, which creates challenges in optimizing and interpreting SPAMS signals. In this paper, we present a well-stirred reactor model for the reactions involved with the laser-induced vaporization and ionization of an individual particle. The SPAMS conditions modeled in this paper include a 248 nm laser which is pulsed for 8 ns to vaporize and ionize each particle in vacuum. The ionization of 1 μm, spherical Al particles was studied by approximating them with a 0-dimensional plasma chemistry model. The primary mechanism of absorption of the 248 nm photons was pressure-broadened direct photoexcitation to Al(y 2 D). Atoms in this highly excited state then undergo superelastic collisions with electrons, heating the electrons and populating the lower energy excited states. We found that the primary ionization mechanism is electron impact ionization of various excited state Al atoms, especially Al(y 2 D). Because the gas expands rapidly into vacuum, its temperature decreases rapidly. The rate of three-body recombination (e - + e - + Al + → Al + e - ) increases at low temperature, and most of the electrons and ions produced recombine within several μs of the laser pulse. The importance of the direct photoexcitation indicates that the relative peak heights of different elements in SPAMS mass spectra may be sensitive to the available photoexcitation transitions. We also discuss the effects of laser intensity, particle diameter, and expansion dynamics.

47 OTHER INSTRUMENTATION↗

The Development of a Generalized Riser Flow Regime Map Based Upon Higher Moment and Chaotic Statistics Using Electrical Capacitance Volume Tomography (ECVT)

Dynamic analyses have been applied to the temporal signals from an Electro Capacitance Volume Tomography instrument located near mid-height on the riser of an industrial-scale cold-flow circulating fluidized bed to characterize gas-solids flow behavior in the riser. Twelve capacitance electrodes surround the cylindrical riser over a height of 1.3 m. The instrument used a neural network deconvolution algorithm to determine the spatially resolved solids fraction recorded at 52 Hz. Experiments were carried out over a range of gas and solids flows in the transport regime using a Geldart Group B bed material, high density polyethylene with mean particle size of 880 μm. The radial solids distribution was found to vary from one-time step to the next between profiles typical of laminar and turbulent flow. The duration of time spent in each of these flow profiles depended upon the operating regime – dilute, core-annular, or fast fluidized bed. The chaotic structure of the temporal data was characterized using the three conventional approaches: the first 4 moments from the distribution of signal in time, system memory parameters from the autocorrelation function and the Hurst exponent, and analysis of the correlationentropy and correlation dimension of the attractor. These signal analysis techniques were used to clearly distinguish differences between different transport operating regimes. Specifically, it was experimentally observed that a riser transitions from core annular flow profile to dilute and dense regimes via increasing the frequency of short term transients to either dilute or dense flow profiles, respectively. A regime map was generated based upon these dynamics using solids flux and gas velocity axes. Fast fluidized, core annular, and dilute each exhibited different degree of dynamic characteristics typical of fluid dominated or particle compromising behavior. It should be noted that the magnitude for the different statistics was in the same range regardless of the regime, it was the radial profile for the statistic that changed and subsequently identified that there was a change in the regime. Finally, a reduced regime map was developed consisting of plotting the gas velocity normalized by the upper transport velocity versus the solids flux normalized by the saturation carrying capacity. The use of this reduced plot allowed the data from widely different conditions to be plotted and compared on the same<p>graph. Note that in many instances, some of the statistics identified the operating point as being in one regime while others indicated that it was in another indicating a transition region between dilute or core annular regimes and between the core annular and fast fluidization regimes. This now provides a tool that can be used to optimize process performance, identify changes in operating states, or replicate process dynamics during process scaling or changing operating parameters. </p>

Breault, Ronald↗

The CUORE Detector and Results

The cryogenic underground observatory for rare events (CUORE) is a cryogenic experiment searching for neutrinoless double beta decay (0νββ) of 130 Te. The detector consists of an array of 988TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. We report the CUORE initial operations and optimization campaigns. We then present the CUORE results on 0νββ and 2νββ decay of 130 Te obtained from the analysis of the physics data acquired in 2017.

0vββ↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Space-Time Quantum Information from the Entangled States of Magnetic Molecule (STI Product)

This collaborative project combines synthesis, measurement, and theory by three faculty members at the Eddleman Quantum Institute of UC Irvine to effectively investigate the quantum properties of molecules in the space, time, and frequency domains. Through synthetic chemistry, molecules are tailored for their magnetic and coherent properties. By combining femtosecond (fs) terahertz (THz) light and a continuous wave (cw) THz laser with a low temperature scanning tunneling microscope (STM), quantum phenomena are probed with simultaneous femtosecond temporal and atomic-scale spatial resolution. In particular, the invention of the quantum superposition microscope (QSM) advances quantum sensing for enhanced spectroscopy and imaging capabilities. Coupling theory to the experimental efforts offers a deeper understanding and predictive power for the molecular systems. The phenomena of superposition, entanglement, and coherence is central to quantum information science and can be realized in qubit states. Many systems can be modeled by a double-well potential in which two levels are formed in the two lowest energy states interacting with the environment and external radiation. In focusing on molecules as two-level systems, the underlying expectation is that their tunable composition and structure allows an effective parameter space to optimize their use as qubits for quantum sensing and computing. The THz radiation induces the superposition between the two states, appearing as temporal oscillations that damp in amplitude. Enhanced spectroscopy and imaging in the time and frequency domains is achieved through the extreme sensitivity of the frequency and damping of coherence of two-level systems to its environment. A single hydrogen molecule trapped in the STM tunneling gap experiences a double-well potential and absorption of THz femtosecond pulses of light creates the superposition of its two levels, appearing as damped oscillations in the light induced direct current (DC). The oscillation frequency depends sensitively on the electric field distribution of the copper nitride (Cu 2 N) surface, through the Stark effect, and associated with the different charge distributions at the copper and nitrogen sites and in between. This QSM can resolve variation in the surface electric field with 0.02 nanometer resolution. In addition, the single hydrogen molecule entaes with nearby hydrogen molecules as seen in the avoided level crossings of energy (oscillation frequency) versus the voltage across the tunneling gap. Thus, the first application of the QSM senses and images the surface electric field at the atomic scale. Results from this project advance fundamental understanding of quantum phenomena, develop novel synthesis, measurement, and theory, provide the knowledge foundation for molecule-based qubits and sensing that enable the development of the QSM and emergent technologies. This project trained researchers in quantum information science, extended knowledge in classrooms, and outreached to the community.

47 OTHER INSTRUMENTATION↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyclotron radiation emission spectroscopy of electrons from tritium $β$ decay and 83m Kr internal conversion

Project 8 has developed a novel technique, cyclotron radiation emission spectroscopy (CRES), for direct neutrino mass measurements. A CRES-based experiment on the beta spectrum of tritium has been carried out in a small-volume apparatus. Here, we provide a detailed account of the experiment, focusing on systematic effects and analysis techniques. In a Bayesian (frequentist) analysis, we measure the tritium endpoint as ${18}$ ${553}_{—19}^{+18}$ (${18}$ ${548}_{—19}^{+19}$) eV and set upper limits of 155 (152) eV (90% C.L.) on the neutrino mass. No background events are observed beyond the endpoint in 82 days of running. We also demonstrate an energy resolution of 1.66 ± 0.19 eV in a resolution-optimized magnetic trap configuration by measuring 83m Kr 17.8-keV internal-conversion electrons. These measurements establish CRES as a low-background, high-resolution technique with the potential to advance neutrino mass sensitivity

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel

Dark matter lighter than 10 GeV / c 2 encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino fog for GeV-scale masses and significant sensitivity down to 10 MeV / c 2 considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector’s sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calorimetry for low-energy electrons using charge and light in liquid argon

Precise calorimetric reconstruction of 5–50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stopping cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT’s well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of σ/E≃9.3%/E⊕1.3% is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N≃30, for example, the energy resolution for electrons below 40 MeV is improved by ≈10%, ≈20%, and ≈40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Status and Ambitions of the US Heavy Element Program

The aim of this whitepaper is to highlight the current capabilities and priorities of the US Heavy Element community and to provide the framework for a coordinated advancement of nuclear science from these studies. This is an organized effort to reflect on what has been achieved in the field given the recommendations and initiatives of the 2015 NSAC Long Range Plan, and on what can be realized in the next decade given current and possibly expanded investments. Current investments have positioned the US community to be among the world leaders in studies of the nuclear and chemical properties of the heaviest elements. These include studies of reaction mechanisms, moving us ever closer to the “island of stability”, in spectroscopy, allowing us to better understand nuclear structure at these extreme proton numbers, in chemical behavior, looking to determine how these elements should be placed on the Periodic Table, in performing the first measurements where isotopes are directly identified by their mass numbers, and in laying the foundation for a potential US-led new element discovery experiment. At present, the highest priority of the US Heavy Element community is to capitalize on the current investments by supporting the operations of US facilities at optimal values. These facilities include the Argonne Tandem Linac Accelerator System at Argonne National Laboratory and other Department of Energy facilities such as the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory, which has a dedicated superheavy element program, as well as university laboratories, including Texas A&M University. The High Flux Isotope Reactor at Oak Ridge National Laboratory is crucial to providing the radioactive isotopes required for heavy element science targets. This facility should be supported to provide the actinide materials that are essential for US-based science. Production of stable, rare isotopes for beam material, including 48 Ca, 50 Ti, 54 Cr and 58 Fe, at the Stable Isotope Production and Research Center is critical to continued research in heavy element science and should be a priority. The continued development of targets for heavy element science and retaining US-based expertise is critical for the heavy element community. This is an area that is currently under pressure. For example, the target laboratory at Argonne National Laboratory serves a broad community and is currently under threat due to loss of critical personnel. The skills needed to make targets for nuclear science and develop new targetry methods need to be supported long term at Argonne, Oak Ridge and Lawrence Livermore National Laboratories as well as maintaining the programs at Oregon State University and San José State University as vital pipelines for training students. Advances in theory are the foundation to understand how nuclei behave and to predict those behaviors in new circumstances. Progress in these studies will necessitate continued and new investment and access to high-performance computing. The future health of the heavy element field is dependent on the continuous support of talented early-career professionals at all levels. It is critical that opportunities continue to be created for the next generation to become established in heavy element research so that we can ensure the field is attracting and retaining the best minds for continued success. It is also clear that to ensure diversity of ideas, perspectives and techniques, we need to recruit diverse personnel that are trained at the best facilities. The heavy element community is in support of continued investment to programs with initiatives in diversity, equity, and inclusion. Looking to the next decade of research, support needs to maintain and grow US leadership in heavy element science. Specifically, new investments in state-of-the-art instrumentation will be essential to scientific development of the field and in expanding scientific knowledge. Advances in the next generation of electron cyclotron resonance ion sources, multi-reflection time-of-flight devices, laser spectroscopy, trapping methods and next generation alpha and gamma spectroscopy systems should be prioritized.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Photon-magnon coupling using gain-assisted spoof-localized surface plasmons

Improving the photon-magnon coupling strength can be done by tuning the structure of microwave resonators to better interact with the magnon counterpart. Planar resonators accommodating unconventional photon modes beyond the half- and quarter-wavelength designs have been explored due to their optimized mode profiles and potentials for on-chip integration. Here, we designed and fabricated an actively controlled ring resonator supporting the spoof localized surface plasmons (LSPs), and implemented it in the investigation of photon-magnon coupling for hybrid magnonic applications. We demonstrated gain-assisted photon-magnon coupling with the YIG magnon mode under several different sample geometries. The achieved coupling amplification largely benefits from the high quality factor (Q-factor) due to the additional gain provided by a semiconductor amplifier, which effectively increases the Q-factor from a nearly null state (passive resonance) to more than 1000 for a quadrupole LSP mode. Our results suggest an additional control knob for manipulating photon-magnon coupled systems exploiting external controls of gain and loss.

47 OTHER INSTRUMENTATION↗

Performance evaluation of the SPES FEBIAD ion source

SPES (Selective Production of Exotic Species) is the Radioactive Ion Beam (RIB) facility that is currently in the installation phase at the Istituto Nazionale di Fisica Nucleare in the Laboratori Nazionali di Legnaro (LNL-INFN). The main purpose of the facility is to deliver neutron-rich radioactive beams with a range of mass between 60 and 160 amu produced as fission products originated within a Uranium Carbide (UC x ) target impinged by high energy protons (40–70 MeV). In the last few years, the SPES group and their collaborators have focused on multiple aspects: development of various ISOL targets, ion sources, a high-power beam dump, versatile Front-End designs, primary proton beam and RIB diagnostics, design of beam optic components, and remote target handling. The development and optimization of ionization sources represents one of the most important R&D activities. The collaboration between SPES and ISOLDE (CERN) groups has enabled the evaluation of the performances of a novel FEBIAD ion source taking advantage of the ISOLDE off-line Front-End. In this paper, the results of efficiency and transversal emittance measurements of the new SPES FEBIAD ion source are presented and discussed. Particular attention is dedicated to the description of the experimental setup and to the comparison of experimental data with simulation to promote the reproducibility of the experimental tests with other types of sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Regression Analysis with the Directed Infusion of Data

Integrating artificial intelligence and machine learning tools into industry necessitates large-scale collaborative efforts that ensure the robust and accurate execution of downstream analytics such as time series prediction, uncertainty quantification, grid optimization, and condition monitoring. However, concerns related to data privacy pervade the nuclear industry due to the proprietary nature of its data and the possibility of data leakage. Legacy techniques such as encryption often require the explicit transmission of data to trustworthy parties, thereby inviting data leakage concerns. The ideal collaboration scenario avoids the explicit dissemination of data/code while maintaining experimental fidelity, which is currently accomplished using various techniques such as trusted execution environments, homomorphic encryption, differential privacy, and multimatrix masking. These techniques, however, often necessitate a trade-off between trust, efficiency, and utility. This article extends a previously proposed technique called the directed infusion of data (DIOD) that ensures data privacy, allows for scalable obfuscation, and combats the risk of data leakage without compromising utility. The experiments discussed in this article examine a regression-type scenario using DIOD with the goal of preserving the inferential link between two variables. Using the point-kinetics equations, regression experiments compare the performance of a model trained using the original data to that of a model trained using the obfuscated data, which produced identical results. Our claim is further strengthened by an information theoretic proof and experiment, which showed that the inferential content between variables remains the same after obfuscation, thereby avoiding the required communication of the proprietary data.

47 - OTHER INSTRUMENTATION↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗

A Multiwavelength Look at the GJ 9827 System: No Evidence of Extended Atmospheres in GJ 9827b and d from HST and CARMENES Data

GJ 9827 is a bright star hosting a planetary system with three transiting planets. As a multiplanet system with planets that sprawl within the boundaries of the radius gap between terrestrial and gaseous planets, GJ 9827 is an optimal target to study the evolution of the atmospheres of close-in planets with a common evolutionary history and their dependence from stellar irradiation. Here we report on the Hubble Space Telescope (HST) and CARMENES transit observations of GJ 9827 planets b and d. We performed a stellar and ISM characterization from the ultraviolet HST spectra, obtaining fluxes for Lyα and Mg ii of F(Lyα) = (5.42{sub −0.75}{sup +0.96}) × 10{sup −13} erg cm{sup −2} s{sup −1} and F(Mgii) = (5.64 ± 0.24) × 10{sup −14} erg cm{sup −2} s{sup −1}. We also investigated a possible absorption signature in Lyα in the atmosphere of GJ 9827b during a transit event from HST spectra, as well as Hα and He i signature for the atmosphere of GJ 9827b and d from CARMENES spectra. We found no evidence of an extended atmosphere in either of the planets. This result is also supported by our analytical estimations of mass loss based on the measured radiation fields for all three planets of this system, which led to a mass-loss rate of 0.4, 0.3, and 0.1 planetary masses per Gyr for GJ 9827b, c, and d, respectively. These values indicate that the planets could have lost their volatiles quickly in their evolution and probably do not retain an atmosphere at the current stage.

47 OTHER INSTRUMENTATION↗

Performance of the upgraded PreProcessor of the ATLAS Level-1 Calorimeter Trigger

The PreProcessor of the ATLAS Level-1 Calorimeter Trigger prepares the analogue trigger signals sent from the ATLAS calorimeters by digitising, synchronising, and calibrating them to reconstruct transverse energy deposits, which are then used in further processing to identify event features. During the first long shutdown of the LHC from 2013 to 2014, the central components of the PreProcessor, the Multichip Modules, were replaced by upgraded versions that feature modern ADC and FPGA technology to ensure optimal performance in the high pile-up environment of LHC Run 2. This paper describes the features of the new Multichip Modules along with the improvements to the signal processing achieved.

47 OTHER INSTRUMENTATION↗