Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “InC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Preliminary Thermal-Hydraulic Analysis of the UTA–2 Subcritical Linear Accelerator–Driven System

The National Nuclear Security Administration’s mission includes establishing a reliable supply of 99 Mo without highly enriched uranium. Oak Ridge National Laboratory (ORNL) supports this objective through collaborative research and development with industrial partners. Niowave Inc., a current partner, is currently designing a subcritical linear accelerator-driven system (ADS) and preparing for the US Nuclear Regulatory Commission’s licensing process. Niowave’s system has the potential to efficiently supply medical radioisotopes. The technology includes a superconducting electron accelerator and a pile of both natural and low-enriched uranium (LEU) targets. The process fissions uranium and many valuable isotopes can then be extracted from the targets. Niowave is currently iterating through conceptual and detailed design processes for several system sizes. This report discusses UTA–2, which is at the demonstration stage. UTA–2 will validate numerical modeling results with experimental measurements before progressing to the detailed design of UTA–3, the commercial-sized ADS. The thermal-hydraulic behavior of the UTA–2 core design was numerically investigated using STAR-CCM+, as described in this report. STAR-CCM+, a state-of-the-art computational fluid dynamics (CFD) software that was commercially developed by Siemens, has an extensive user base and a set of validation studies. It is also compliant with the American Society of Mechanical Engineers’ Nuclear Quality Assurance 1 standard. Three cases are investigated in this report. Case 1 quantified the temperature field within the UTA–2 assembly and water tank using only conduction as the method of thermal energy transport. This simplified approach was overly conservative and yielded wetted cladding temperatures above the coolant saturation temperature. In this case, the maximum temperature of the wetted cladding surface of the highest power rod exceeded the saturation temperature of water by 63.8°C. Because of the overly conservative approach taken in Case 1 and its negative subcooled margin, buoyancy-driven natural circulation flow physics were implemented in Case 2. Adding coolant motion significantly distributed the thermal energy of the system through convective heat transfer. This relatively small amount of convective heat transfer significantly reduced system temperatures and increased the subcooled margin from –63.8 to 61.3°C. This margin confirmed that no boiling was expected during normal operation of UTA–2 at 230 W. Case 3 had no additional physics models but considered an overpower event during which the power of each LEU and natural uranium rod was at its respective peak values. This resulted in a study with the total assembly power equal to 176% of the nominal power of 230 W considered in Cases 1 and 2. The resulting natural circulation flows were slightly enhanced. The subcooled margin decreased slightly to 46.3°C, which is still a significant margin to local boiling of the water within the tank. This margin confirmed that no boiling was expected during an abnormal operation of UTA–2 at 406 W.

07 ISOTOPE AND RADIATION SOURCES↗

Beneficial use of CO 2 from Coal-Fired Power Plants for Production of Animal Feeds

This Final Technical Report for Award DE-FE0031717 is a non-confidential overview of the algae-based CO 2 utilization research project carried out by MicroBio Engineering Inc. (MBE) and project partners - the Orlando Utilities Commission-Stanton Energy Center (OUC-SEC), California Polytechnic University (Cal Poly, San Luis Obispo), University of Central Florida (UCF), and Global Thermostat LLC. The project ran from January 1 2019 to March 2022.

20 FOSSIL-FUELED POWER PLANTS↗

Cybersecurity Center for Secure Evolvable Energy Delivery Systems (SEEDS)

The SEEDS Center has successfully completed its mission to research and develop a plethora of technologies during its six-year timeframe. The Center institutions of the University of Arkansas, the University of Arkansas at Little Rock, Carnegie-Mellon University, Florida International University, Lehigh University, and MIT all worked together with industry partners to define relevant energy sector cybersecurity issues, create projects to address those issues, and execute those projects in roughly two and three-year increments. The short project descriptions below indicate some really keystone areas of research. The teams generally met all of their objectives with only a few exceptions, which is tremendous in an R&D center. In fact, the success of one project led to the creation of a startup company, Bastazo, Inc. that is commercializing the SPARTAN project. In addition to creating new technologies, the Center helped to educate a desperately needed workforce. Lastly, a big success is that the UA seriously followed the mandate of the original program manager to try to become self-sustaining. This effort has resulted in a combined NSF center with the CREDC Center at the University of Illinois, Urbana-Champaign. To summarize the SEEDS effort, great research was funded, students were educated and put into the workforce, technology is being commercialized and offered to the electric sector, and the research efforts are being sustained through additional funding. The effort was an unqualified success.

03 NATURAL GAS↗

Statement of Work for Impact Testing

Lawrence Livermore National Laboratory (“LLNL”) will outsource impact testing (also known as drop hammer testing) of PETN (Pentaerythritol tetranitrate) to Safety Management Services Inc. (“Subcontractor”). This document describes the objective, technical approach, and deliverables. Subcontractor will conduct impact testing studies on three PETN samples. LLNL will provide the samples. LLNL selected this company for impact testing because LLNL has an impact test machine purchased from the same vendor. The objective of this work is to answer the following questions: 1) What are the variations in impact sensitivity results between three PETN samples LLNL will provide?; 2) What is the effect of starting mass on impact sensitivity of PETN?

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Value of the Gasoline and Fuel Oil Co-Product Fractions Generated by the PNNL/LanzaTech Alcohol-to-Jet Process (Final Report)

The BETO-funded PNNL collaboration with LanzaTech, Inc. utilizes patented technology to address the need for low aromatic jet fuel blendstocks. The PNNL/LanzaTech alcohol-to-jet (ATJ) process converts ethanol from LanzaTech’s syngas fermentation process to jet-range isoparaffins. The aim of this Cooperative Research Development Agreement (CRADA) project was to improve the commercial viability of the LanzaTech/ PNNL ATJ process by developing two new co-product options. Two Focus Areas (FA) were explored: FA1) Increasing the RON of the lighter-than-jet gasoline fraction above 98; and FA2) Creating a synthetic lubricant base oil from the heavier-than-jet fraction. For FA 1, multiple processing approaches were evaluated, and RONs ranging from 96-100 were obtained, each comprising different processing costs. The most cost effective approach identified was a single-step process and yielded a liquid product of 97. Thus, additional development is required to obtain a RON > 98. We will continue work on this focus area with separate Direct Funding Opportunity (DFO) funding within the DOE-BETO Co-Optima Consortium (expected to begin Q2-FY21). Experimental work will focus on i) increasing single pass conversion to > 50%, and ii) obtaining a > 98 RON product. Technoeconomic analysis performed in this project suggests cost competitiveness provided these technical targets can be met. For FA2, multiple approaches were evaluated for increasing the viscosity index (VI) of the heavier-than-jet fraction to at least 120 in order to meet ASTM specifications for a Group III Base Oil (ASTM D6074). All other ASTM specifications are already met. A viscosity index of 115 was obtained, and with minimal undesirable cracking products. We believe a VI of 115 is about the highest possible from a catalytic approach, per review of the patent literature. In order to further increase the VI to > 120 we believe additives and/or liquid-liquid extraction is required. TEA performed earlier in the project suggests cost competitiveness with market prices assuming cracking byproducts are kept < 10 wt.%. If TEA updated with this additional processing still projects economic feasibility next steps could be taken in a subsequent effort.

02 PETROLEUM↗

Synthetic Metal Atomic Layer Deposition Tool (Final Report)

As part of the Cyclotron Road program, Laminera Inc. worked towards development of atomic layer deposition process customizations and tool modifications to produce synthetic metal films at commercial scale and improve the film quality. Today's state-of-the-art in atomic layer deposited synthetic metal technology is only possible at a research-scale because current tools have practical limitations for scaling industrially and generating high conductivity films. Ultrathin, conformal synthetic metal films have many possible applications such as high surface area nanoporous electrodes for supercapacitors and water desalination devices; protective electrode coatings for electrochemical devices; seed layers for semiconductor device fabrication; or metallic component stabilizing coatings that enable enhanced storage density in next generation hard disk drives. The best synthetic metal conductive and plasmonic properties have been demonstrated using sputtering, which relies on high temperature sputtering with substrate dependent and directional growth limiting usage. This work explored refining process and tool modifications to create ultrathin, conformal, synthetic metal films that can be deposited with high quality over complex three-dimensional surfaces.

36 MATERIALS SCIENCE↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 577: Area 5 Chromium Containing Waste Disposal Cells, Nevada National Security Site, Nevada

This Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) is for Corrective Action Unit (CAU) 577, “Area 5 Chromium Containing Waste Disposal Cells,” which is located in Area 5 of the Nevada National Security Site (NNSS). CAU 577 includes five low-level waste cells at the Area 5 Radioactive Waste Management Site (RWMS) where buried waste received from Nuclear Fuel Services, Inc. (NFS), was subsequently determined to contain chromium that exceeded the Toxicity Characteristic Leaching Procedure regulatory limit, which would require the waste to carry hazardous waste code D007. To resolve issues related to this alleged violation of hazardous waste regulations, a Settlement Agreement was executed between the Nevada Division of Environmental Protection (NDEP) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office on April 25, 2019, which identified agreed-upon mitigation measures. The Settlement Agreement required that the chromium-containing waste received from NFS would be addressed following the closure process laid out in the Federal Facility Agreement and Consent Order (FFACO).

54 ENVIRONMENTAL SCIENCES↗

Particle Separator for Improved Flameless Pressurized Oxy-Combustion

The team of Southwest Research Institute® (SwRI®), ITEA, Electric Power Research Institute, Inc. (EPRI), and General Electric Global Research (GE) is advancing Flameless Pressurized Oxy-combustion (FPO), a novel coal technology. This effort seeks to develop a particle separator for the hot-gas stream leaving the FPO loop. In order to maximize the energy extracted from the cycle, the hot gas is put through a turbo-expander before flue-gas treatment. The particle separator designed under this project sought to operate at high temperature and with low-pressure drop, protecting the turbo-expander from erosion damage. The team engaged potential vendors for the test, developed plans for the pilot test loop modification, and refined requirements for the commercial turbo-expander.

01 COAL, LIGNITE, AND PEAT↗

DFO Computational Modeling Project - Catalytic Upgrading of Bio-based Furfural to 1,5-Pentanediol: A New Renewable Monomer for the Coatings Industry (Final Report)

This report summarizes the results of a collaborative effort between Oak Ridge National Laboratory (ORNL) and Pyran™ Inc. to utilize modeling capabilities developed by the CCPC (Consortium for Computational Physics and Chemistry) to assist Pyran in scaling up its proprietary process for thermocatalytic conversion of furfural to 1,5 pentanediol (PDO). Pyran’s bio-based PDO is a direct replacement for petroleum-based PDO and 1,6 hexanediol (HDO) currently used in polymers, additives, coatings, adhesives and sealants. The current market is in excess of $\$$1B/yr. According to Pyran, their production process results in 95+% reduction in fossil CO 2 at lower production costs compared to the existing petroleum-based routes for PDO & HDO. Other chemicals based on intermediates from this process have current markets in excess of $\$$10B/yr.

36 MATERIALS SCIENCE↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

Grid-Scale Electricity Storage at Lowest Possible Cost Enabled by Pumped Heat Electricity Storage (Final Report)

Grid-scale energy storage technologies that can provide greater than 10 hours of electricity at full power address a critical need for full penetration of renewables on electricity grids worldwide, minimize renewable curtailment, and maximize grid security and reliability. Pumped Heat Energy Storage (PHES) systems can store energy thermally in any location at the low costs necessary for displacing fossil fuels, reducing foreign fuel imports, and reducing emissions to maintain the energy security of the United States. The award allowed Southwest Research Institute® (SwRI®) and Malta, Inc. (Malta) to advance the PHES concept to a proof-of-concept demonstration for a kW-scale system. The project focused on system operation and integration. The main project objectives were: 1. Address first implementation challenges 2. Explore system control strategies and operation 3. Translate lessons learned to the full-scale system Through these objectives the project completes a first demonstration of this technology and reduces the technical risk associated with a full-scale system.

25 ENERGY STORAGE↗

Performance Characterization and Energy Savings Assessment of a Radial Flux Surface Permanent Magnet Motor Technology

This project is part of the National Renewable Energy Laboratory's (NREL's) "Commercialization Assistance Program" to provide technical expertise to help emerging companies overcome technical barriers to commercialization. In this study, NREL has evaluated the efficiency and energy saving potential of a novel motor technology designed by ZEUS Motor Inc. located in Wheat Ridge, Colorado. The motor expands on permanent magnet AC motor (PMAC) design to create a new "radial flux, surface PMAC", or RF-sPMAC motor that is expected to outperform other novel motor technologies on the market. Here, the motor showed considerable energy benefits over typical induction motors. The motor benefits from a tightly-packed magnetic steel and copper stator that allows the motor size to be reduced to a thin disc with an internal cavity 1/30th the size of a traditional induction motor. The housing is also aluminum which is magnetically benign. This eliminates the need for external cooling (up to 25 HP), in addition to reducing power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Nickel Cathode Materials for High-Energy, Long-Life, Low-Cost Lithium-Ion Batteries (Final Report)

The overall goal of this project is to produce Li-ion cells, which deliver at least 600 Wh kg -1 at the cathode level with usable lifetimes of at least 1,000 cycles or 15 years of storage (calendar life). A secondary goal of this project is to minimize the use of cobalt in the cathode, with the ultimate goal of eliminating cobalt entirely. To develop such a cathode, the University of Texas at Austin (UT Austin) team extensively investigated the structural, physical, and chemical properties of layered oxide materials. A panel of dopant elements were surveyed with an emphasis on identifying those, which impart electrochemical and thermal stability. Of those tested, Al and Mg showed the greatest performance improvements while still being easily incorporated into the cathode through simple alterations of the precursor coprecipitation method. Other dopants, such as Ta, Nb, B, and F significantly improved cathode performance, yet their mode of incorporation required additional processing which negated their use under scaled-up conditions. From this work, a first-generation cathode LiNi 0.85 Mn 0.075 Co 0.05 Al 0.02 Mg 0.005 O 2 (NMCAM-85) was produced and an initial set of 2 Ah cells was fabricated by Tesla Inc. These cells delivered 650 Wh kg -1 and a cycle life of just over 700 cycles. Further improvements were garnered through careful study of electrolyte additives. A tailored, ethylene carbonate (EC)-free electrolyte was developed, which improved capacity retention from 60% to 82% after 500 cycles in model LiNi 0.9 Mn 0.05 Al 0.05 O 2 (NMA-90) full cells. This study identified the additives fluoroethylene carbonate (FEC) and lithium difluorophosphate (LiPO 2 F 2 ) as beneficial additives, which were included in the electrolyte for the end-of-project cells. The UT Austin team developed a high-Ni layered oxide cathode LiNi 0.85 Mn 0.1 Al 0.05 Mg 0.005 O 2 (NMAM-85) capable of meeting the project goals. This cathode was synthesized in kilogram quantities and delivered to Tesla for fabrication into 2 Ah pouch cells for DOE testing. These large-format cells achieved 630 Wh kg -1 at the cathode level under the designated testing parameters, meeting the project goal with a completely cobalt-free cathode. The large-format cells are currently undergoing cycle life and calendar life evaluation at Idaho National Lab.

25 ENERGY STORAGE↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synthesis and Photonic Sintering of Proton Conducting Lanthanide Nickelates

Lanthanide nickelate perovskites are known proton conductors at intermediate temperatures (350-600°C). They are attractive targets for proton conducting fuel cells and electrolyzers due to their operational temperature range and their stability in the presence of CO 2 . These materials have the formula LNiO 3 , with the lanthanide L = La, Ce, Pr, Nd, or Sm. Sintering is challenging due to phase transformations that occur at lower temperatures than those required for sintering. In this project, a series of lanthanide nickelate perovskites was synthesized via both a precursor solid solution method and the glycine nitrate process. Powders derived from the precursor solid solution method for LaNiO 3 and NdNiO 3 were sintered at Utility Global Inc. at various temperatures utilizing fast photonic sintering. LaNiO 3 was successfully sintered while maintaining the perovskite phase. NdNiO 3 underwent a phase transformation at all the conditions tested. The stability of the perovskite phase decreases moving right across the lanthanides in the periodic table, while the expected proton conductivity increases. These results will inform further investigations into lanthanide nickelate perovskites toward the goal of producing a free-standing, sintered, proton-conducting membrane.

36 MATERIALS SCIENCE↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗