Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Implants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Non-magnetic compensation in ferromagnetic Ga1-xMnxAs and Ga1-xMnxP synthesized by ion implantation and pulsed-laser melting

The electronic and magnetic effects of intentional compensation with non-magnetic donors are investigated in the ferromagnetic semiconductors Ga1-xMnxAs and Ga1-xMnxP synthesized using ion implantation and pulsed-laser melting (II-PLM). It is demonstrated that compensation with non-magnetic donors and MnI have similarqualitative effects on materials properties. With compensation TC decreases, resistivity increases, and stronger magnetoresistance and anomalous Hall effect attributed to skew scattering are observed. Ga1-xMnxAs can be controllably compensated with Te through a metal-insulator transition through which the magnetic and electrical properties vary continuously. The resistivity of insulating Ga1-xMnxAs:Te can be described by thermal activation to the mobility edge and simply-activated hopping transport. Ga1-xMnxP doped with S is insulating at all compositions but shows decreasing TC with compensation. The existence of a ferromagnetic insulating state in Ga1-xMnxAs:Te and Ga1-xMnxP:S having TCs of the same order as the uncompensated materials demonstrates that localized holes are effective at mediating ferromagnetism in ferromagnetic semiconductors through the percolation of ferromagnetic 'puddles' which at low temperatures.

36 MATERIALS SCIENCE↗

High-Performance, Long-Life, Rechargeable Li–CO 2 Batteries based on a 3D Holey Graphene Cathode Implanted with Single Iron Atoms

A highly efficient cathode catalyst for rechargeable Li-CO 2 batteries is successfully synthesized by implanting single iron atoms into 3D porous carbon architectures, consisting of interconnected N,S-codoped holey graphene (HG) sheets. The unique porous 3D hierarchical architecture of the catalyst with a large surface area and sufficient space within the interconnected HG framework can not only facilitate electron transport and CO 2 /Li+ diffusion, but also allow for a high uptake of Li 2 CO 3 to ensure a high capacity. Consequently, the resultant rechargeable Li-CO 2 batteries exhibit a low potential gap of approximate to 1.17 V at 100 mA g -1 and can be repeatedly charged and discharged for over 200 cycles with a cut-off capacity of 1000 mAh g -1 at a high current density of 1 A g -1 . Density functional theory calculations are performed and the observed appealing catalytic performance is correlated with the hierarchical structure of the carbon catalyst. This work provides an effective approach to the development of highly efficient cathode catalysts for metal-CO 2 batteries and beyond.

(2) batteries↗

From Metal–Organic Frameworks to Single‐Atom Fe Implanted N‐doped Porous Carbons: Efficient Oxygen Reduction in Both Alkaline and Acidic Media

Abstract It remains highly desired but a great challenge to achieve atomically dispersed metals in high loadings for efficient catalysis. Now porphyrinic metal–organic frameworks (MOFs) have been synthesized based on a novel mixed‐ligand strategy to afford high‐content (1.76 wt %) single‐atom (SA) iron‐implanted N‐doped porous carbon (Fe SA ‐N‐C) via pyrolysis. Thanks to the single‐atom Fe sites, hierarchical pores, oriented mesochannels and high conductivity, the optimized Fe SA ‐N‐C exhibits excellent oxygen reduction activity and stability, surpassing almost all non‐noble‐metal catalysts and state‐of‐the‐art Pt/C, in both alkaline and more challenging acidic media. More far‐reaching, this MOF‐based mixed‐ligand strategy opens a novel avenue to the precise fabrication of efficient single‐atom catalysts.

Jiao, Long↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Development of a New Subclavian Arterial Infusion Chemotherapy Method for Locally or Recurrent Advanced Breast Cancer Using an Implanted Catheter-Port System After Redistribution of Arterial Tumor Supply

Locally or recurrent advanced breast cancers can receive arterial blood supply from various arteries, such as the internal thoracic artery (ITA), the lateral thoracic artery, and the other small arterial branches originating from the subclavian artery. Failure to catheterize and subsequent formation of collateral arterial blood supply from various arteries are some of the reasons why the response to conventional selective transarterial infusion chemotherapy is limited and variable. To overcome this problem, we developed a new subclavian arterial infusion chemotherapy method using an implanted catheter-port system after redistribution of arterial tumor blood supply by embolizing the ITA. We named this technique ('redistributed subclavian arterial infusion chemotherapy' (RESAIC)). Using RESAIC, patients can be treated on an outpatient basis for extended periods of time. Eleven patients underwent RESAIC, and the complete remission and partial response rate in 10 evaluable patients was 90%: complete remission [CR] n = 4, partial remission n = 4, stable disease n = 1, and not evaluable n = 1. Three of four patients with CR had no distant metastasis, and modified radical mastectomy was performed 1 month after conclusion of RESAIC. The resected specimens showed no residual cancer cells, and pathologically confirmed complete remission was diagnosed in each of these cases. Although temporary grade-3 myelosuppression was seen in three patients who were previously treated by systemic chemotherapy, there was no other drug-induced toxicity or procedure-related complications. RESAIC produced a better response and showed no major complications compared with other studies despite the advanced stage of the cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Everolimus-induced Pneumonitis after Drug-eluting Stent Implantation: A Case Report

Despite the wide use of everolimus as an antineoplastic coating agent for coronary stents to reduce the rate of restenosis, little is known about the health hazards of everolimus-eluting stents (EES). We describe a case of pneumonitis that developed 2 months after EES implantation for angina. Lung pathology demonstrated an organizing pneumonia pattern that responded to corticosteroid therapy. Although the efficacy of EES for ischemic heart disease is well established, EES carries a risk of pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two Wire System and Modified Olive Tip to Facilitate Implantation of Fenestrated TEVAR in Patient with Proximal Descending Aortic Pathology: First Two Cases

Introduction: Although Fenestrated TEVAR (F-TEVAR) has been considered to be a more physiologic approach to treat proximal descending aortic pathology, its application is still limited due to availability, cost and technical difficulties. We introduce a new design of fenestrated stent graft with a new delivery system and successfully performed first in human implantation in two patients, one with an aortic aneurysm and one with an acute aortic dissection. Materials and Methods: The design of these two wires fenestrated stent graft include creation of an additional lumen at the side of the olive tip during manufacture, from which an additional wire can be introduced for a side branch passing into the fenestration, running inside the stent graft and exit the delivery sheath through additional hub. The two wires will facilitate delivery and deployment of the stent graft. One patient with descending aortic aneurysm and another with Stanford B aortic dissection is included in this first in human study. Results: The aneurysm and dissection were completely excluded immediately after the TEVAR. Six month follow up CT showed good position of the stent graft and patent LSA in both patients. In the patient with aortic dissection, expansion of the true lumen and partial thrombosis of the false lumen was seen. Conclusions: This is a report of a two wire system in 2 patients with distal aortic arch pathology demonstrating a good technical and clinical success using pre-cannulated fenestrations through a modified nose cone olive. Level of Evidence: Level 4, report of two cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Factors of Infection and Role of Antibiotic Prophylaxis in Totally Implantable Venous Access Port Placement: Propensity Score Matching

Background: To evaluate risk factors of infection and effectiveness of preprocedural single-dose intravenous prophylactic antibiotic (PABX) during totally implantable venous access port (TIVAP) placement in preventing procedure-related infections. Methods: This was a retrospective single-institution multicenter study evaluating short-term (30-day) infection outcomes after TIVAP placement. Correlation between infection rates and clinical factors, including hematologic versus non-hematologic malignancy, inpatient versus outpatient status, single versus double lumen and PABX, was investigated using univariate and multivariable analysis in the overall study population as well as the propensity-score-matched cohort. Results: Overall, 5967 patients underwent TIVAP placement from 2005 to 2016, of which 3978 (67%) patients received PABX. On propensity score matching, 1952 patients with PABX were matched to the same number of patients without PABX. TIVAP was removed due to infection concern in 48 patients in unmatched and 30 patients in matched population. There was no difference in the rate of infection between those who received PABX and those who did not in both unmatched and matched population (p = 0.5387 and 0.9999). Although infection rate was significantly higher in patients who had TIVAP placement in inpatient setting (p < 0.0001), who received a double-lumen TIVAP (p < 0.0001), or who had hematologic malignancy (p = 0.0004) on univariate analysis, inpatient status was the sole factor associated with higher rate of TIVAP infection on multivariable analysis of both overall (odds ratio 2.31, p < 0.0001) and matched populations (odds ratio 4.36, p = 0.0004). Conclusion: Placement of TIVAP in inpatient setting increases the risk of TIVAP infection. PABX before TIVAP placement does not prevent short-term procedure-related infections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Holding of juvenile salmonids for surgical implantation of electronic tags: a review and recommendations

Many telemetry based studies require that fish be sampled from the wild and then held for some amount of time both prior to and after the implantation of a transmitter. However, the effects of such holding (or the lack thereof) are often overlooked. Pre-surgical holding often occurs to facilitate logistical needs of research projects and as an attempt to minimize negative physiological effects due to capture and handling stress. Further, post-surgical holding time and conditions greatly influence the physiological state of fish prior to being returned to the wild. This paper reviews pertinent studies pertaining to the effects of surgical holding on the behavior, physiology, and survival of fishes, with particular emphasis on juvenile salmonids. The effects of individual aspects of surgical holding such as stressors, time, holding conditions and water quality are also examined. Recommendations regarding certain aspects of surgical holding (e.g., holding duration) are offered with a goal of reducing bias related to the surgical process. Pre- and post-surgical holding times of 18–36 h are suggested as a general guideline for juvenile salmonids.

59 BASIC BIOLOGICAL SCIENCES↗

High-voltage (900 V) 4 H-SiC Schottky diodes with a boron-implanted guard p-n junction

High-voltage (900 V) 4H-SiC Schottky diodes terminated with a guard p-n junction were fabricated and studied. The guard p-n junction was formed by room-temperature boron implantation with subsequent high-temperature annealing. Due to transient enhanced boron diffusion during annealing, the depth of the guard p-n junction was equal to about 1.7 {mu}m, which is larger by approximately 1 {mu}m than the projected range of 11 B ions in 4H-SiC. The maximum reverse voltage of fabricated 4H-SiC Schottky diodes is found to be limited by avalanche breakdown of the planar p-n junction; the value of the breakdown voltage (910 V) is close to theoretical estimate in the case of the impurity concentration N = 2.5 x 10{sup 15} cm{sup -3} in the n-type layer, thickness of the n-type layer d = 12.5 {mu}m, and depth of the p-n junction r{sub j} = 1.7 {mu}m. The on-state diode resistance (3.7 m{omega} cm{sup 2}) is controlled by the resistance of the epitaxial n-type layer. The recovery charge of about 1.3 nC is equal to the charge of majority charge carriers that are swept out of an epitaxial n-type layer under the effect of a reverse voltage.

36 MATERIALS SCIENCE↗

Relationship of non-invasive quantification of myocardial blood flow to arrhythmic events in patients with implantable cardiac defibrillators

Background: Ischemia contributes to arrhythmogenesis though its role is incompletely understood. Abnormal myocardial perfusion measured by PET imaging may predict ventricular arrhythmias (VAs) in a high-risk population. Methods: Patients with implantable cardiac defibrillators who had undergone rubidium-82 cardiac PET imaging were identified. Patients were stratified by median MBF and MFR values for analysis. The Cox proportional hazards model was used to assess the impact of myocardial perfusion on survival free of VT independent of critical covariates. Results: A total of 159 patients (124 (78%) males, median age 65.9 years, IQR [56.76-72.63]) were followed for 1.43 years IQR [0.83-2.21]. VA occurred in 29 patients (23.7%). After adjustment for ejection fraction, age, and sex, impaired stress MBF was associated with an increased risk of VA (adjusted HR per ml/min/g 1.52, 95% CI (1.01-2.31), P = 0.04). Summed rest and stress scores were not predictive of VA. Among patients with severe LV dysfunction, stress MBF remained an independent predictor of VA (adjusted HR per 1 ml/min/g HR 1.69, 95% CI (1.03-11.36), P = 0.03), while residual EF, summed rest, and summed stress scores were not (P > 0.05). Conclusions: Impaired stress myocardial blood flow was associated with less survival free of ventricular arrhythmias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of {sup 18}F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis

Objective: We performed a meta-analysis evaluating the use of fluorine-18-fluorodeoxyglucose ({sup 18}F-FDG) positron-emission tomography (PET)/computed tomography (CT) in the diagnosis of cardiovascular implantable electronic device (CIED) infections. Background: PET/CT may be helpful in the diagnosis of CIED infection, particularly in patients with the absence of localizing signs or definitive echocardiographic findings. Methods: PubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov from January 1990 to April 2017 were searched for studies evaluating the accuracy of PET/CT in the diagnosis of CIED infections. Results: Overall, 14 studies involving 492 patients were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of CIED infection was 83% (95% CI 78%-86%) and the pooled specificity was 89% (95% CI 84%-94%). PET/CT demonstrated a higher sensitivity of 96% (95% CI 86%-99%) and specificity of 97% (95% CI 86%-99%) for diagnosis of pocket infections. Diagnostic accuracy for lead infections or CIED-IE was lower with pooled sensitivity of 76% (95% CI 65%-85%) and specificity of 83% (95% CI 72%-90%). Conclusion: Use of PET/CT in the evaluation of CIED infection has both a high sensitivity (83%) and specificity (89%) and deserves consideration in the management of selected patients with suspected CIED infections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR Imaging of Patients with Cardiac Implantable Electronic Devices (CIEDs): Implementing a Program and Optimizing CMR

Purpose of review: How to implement a program for MRI in patients with conditional and non-conditional (“legacy”) CIED. How to optimize safety and image quality in CMR? What the radiologists need to know: device programming, pre- and post-MRI CIED parameters. Recent findings: New Center for Medicare and Medicaid Services (CMS) guidelines have opened MRI to many patients with nonconditional devices. Newer pulse sequences for cardiac MRI (CMR) in device patients, including modified cine, late gadolinium enhancement and T1 mapping sequences, have resulted in improved image quality in device patients. We present several cases of CMR in device patients, including imaging of leadless pacemakers subcutaneous ICDs. Imaging pitfalls/artifacts in CMR interpretation are also presented. Summary: An organized institutional workflow with an established protocol involving proper patient screening, device programming, scan monitoring, and pre- and post-ICD interrogation minimizes risk in patients with conditional and non-conditional CIEDs. Although rare, significant changes in lead performance, power-on/reset, inappropriate pacing or ICD discharges and battery voltage depletion should be documented. High-quality scans with accurate scar characterization in CIED patients require the use of wideband sequences. CMS has recently acknowledged MRI as a reasonable test necessary for the diagnosis and treatment of beneficiaries with implanted CIEDs, improving the financial prospects and encouraging future developments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal diffusivity recovery and defect annealing kinetics of self-ion implanted tungsten probed by insitu transient grating spectroscopy

Tungsten is a promising candidate material for plasma-facing armour components in future fusion reactors. A key concern is irradiation-induced degradation of its normally excellent thermal transport properties. In this comprehensive study, thermal diffusivity degradation in ion-implanted tungsten and its evolution from room temperature (RT) to 1073 K is considered. Five samples were exposed to 20 MeV self-ions at RT to achieve damage levels ranging from 3.2 x 10 -4 to 3.2 displacements per atom (dpa). Transient grating spectroscopy with in-situ heating was then used to study thermal diffusivity evolution as a function of temperature. Using a kinetic theory model, an equivalent point defect density is estimated from the measured thermal diffusivity. The results showed a prominent recovery of thermal diffusivity between 450 K and 650 K, which coincides with the onset of mono-vacancy mobility. After 1073 K annealing samples with initial damage of 3.2 x 10 -3 dpa or less recover close to the pristine value of thermal diffusivity. For doses of 3.2 x 10 -2 dpa or higher, on the other hand, a residual reduction in thermal diffusivity remains even after 1073 K annealing. Transmission electron microscopy reveals that this is associated with extended, irradiation-induced dislocation structures that are retained after annealing. A sensitivity analysis shows that thermal diffusivity provides an efficient tool for the assessing total defect content in tungsten up to 1000 K.

36 MATERIALS SCIENCE↗

The detection of He in tungsten following ion implantation by laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) results are presented that provide depth-resolved identification of He implanted in polycrystalline tungsten (PC-W) targets by a 200 keV He+ ion beam, with a surface temperature of approximately 900 °C and a peak fluence of 10 23 m –2 . He retention, and the influence of He on deuterium and tritium recycling, permeation, and retention in PC-W plasma facing components are important questions for the divertor and plasma facing components in a fusion reactor, yet are difficult to quantify. The purpose of this work is to demonstrate the ability of LIBS to identify helium in tungsten; to investigate the sensitivity of laser parameters including, laser energy and gate delay, that directly influence the sensitivity and depth resolution of LIBS; and to perform a proof-of-principle experiment using LIBS to measure relative He intensities as a function of depth. In conclusion, the results presented demonstrate the potential not only to identify helium but also to develop a methodology to quantify gaseous impurity concentration in PC-W as a function of depth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermodynamic description of the Ti-Mo-Nb-Ta-Zr system and its implications for phase stability of Ti bio-implant materials

Titanium alloys are great candidates for applications such as biomedical implants that require biocompatibility, a low Young's modulus and a high strength. However, the properties of Ti alloys are highly dependent on phase stability. Here in the present work, a database for the Ti-Mo-Nb-Ta-Zr system has been evaluated using the CALPHAD (CALculation of PHAse Diagram) approach. The database was completed by evaluating the accuracy of previously modeled systems from literature and modeling systems that, to the best of the authors’ knowledge, had no modeling available in literature. All of the binary systems that make up the Ti-Mo-Nb-Ta-Zr system had previously modeled thermodynamic descriptions available in the literature and in most cases had multiple different descriptions available, which meant determining which previous thermodynamic description most accurately modeled the binary system with a direct focus on the bcc phase. In order to determine the accuracy of the multiple available thermodynamic descriptions from literature a combination of experimental data (also obtained from the literature) and computed thermochemical properties of the bcc phase from DFT (Density Functional Theory)-based first-principles calculations (present work) were used. Once the thermodynamic descriptions for the binary systems were chosen, focus shifted to the Ti-containing ternary systems. The Ti-Mo-Zr, Ti-Nb-Zr and Ti-Ta-Zr systems had previous thermodynamic description available in literature, which were incorporated without changes into the working database. The Ti-Mo-Ta, Ti-Nb-Ta and Ti-Mo-Nb systems had, to the authors’ knowledge, no descriptions available in the literature. Interaction parameters were determined for the Ti-Mo-Ta and Ti-Nb-Ta systems, and no interaction parameters were introduced for the Ti-Mo-Nb system. The database introduced by this work satisfactorily predicts the thermodynamics of the Ti-Mo-Nb-Ta-Zr system.

CALculation of PHAse Diagrams↗

Tuning the surface energy of fluorinated diamond-like carbon coatings via plasma immersion ion implantation plasma-enhanced chemical vapor deposition with 1,1,1,2-tetrafluoroethane

Here, we demonstrate an environmentally friendly and scalable method to create fluorine-doped diamond-like carbon (F-DLC) coatings using plasma immersion ion implantation plasma-enhanced chemical vapor deposition (PIII-PECVD) with 1,1,1,2-tetrafluoroethane. F-DLC films tend to have low wettability and good mechanical flexibility, which make them suitable for applications in biomedical devices and antibiofouling surfaces. We report on the effects of fluorine incorporation on the surface chemistry, surface energy, and morphology of these coatings, showing that our method is effective in increasing the fluorine content in the F-DLC up to 40%. We show that the addition of fluorine leads to a decrease in surface energy, which is consistent with a reduction in surface wettability.

Contact angle↗