Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hardness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Tracking oxygen vacancy migration in memristor devices using operando hard X-ray photoelectron spectroscopy

Fabrication of ultrathin (sub-2 nm) oxide semiconductor memristors poses the fundamental challenge of achieving oxide growth with atomic precision in terms of electronic structure and defect formation. Recently, ultrathin memristors consisting of bilayers of mixed Al 2 O 3 and MgO atomic layers were fabricated using an in vacuo atomic layer deposition process. This approach offers a unique platform for precise atomic control of oxygen vacancies in the device in which the vacancies are introduced by placing MgO atomic layers between pristine Al 2 O 3 layers. In this work, we present a systematic operando Hard X-ray PhotoElectron Spectroscopy (HAXPES) study of the switching of such memristors, combined with complementary current-voltage and capacitance-voltage (C-V) measurements. We used a memristor stack of Al 2 O 3 /MgO atomic layers, with the MgO-containing oxide deposited on the bottom Al metal electrode and a pure Al 2 O 3 layer below the top Pd electrode. HAXPES analysis shows a substantial change in the chemical shift of the Aluminum oxide when switching between the ”OFF” and ”ON” states indicative of a redistribution of oxygen vacancies in the device active layer. Interestingly, subsequent switching to the OFF state shows hysteretic behavior indicating the retention of some oxygen vacancies in the top Al 2 O 3 layer. This vacancy retention can be correlated with the stochastic behavior of the switching voltage observed in these devices. C–V measurements show a clear frequency-dependent response in the OFF state, consistent with enhanced polarization and vacancy trapping at low frequencies.

47 OTHER INSTRUMENTATION↗

Hard-to-soft transition-enhanced piezoelectricity in poly(vinylidene fluoride) via relaxor-like secondary crystals activated by high-power ultrasonication

We report although high piezoelectric coefficients have recently been observed in poly(vinylidene fluoride-co-trifluoroethylene) [P(VDF-TrFE)] random copolymers, they have low Curie temperatures, which makes their piezoelectricity thermally unstable. It has been challenging to achieve high piezoelectric performance from the more thermally stable PVDF homopolymer. In this report, we describe how high-power ultrasonic processing was used to induce a hard-to-soft piezoelectric transition and improve the piezoelectric coefficient d 31 in neat PVDF. After high-power ultrasonication for 20 min, a uniaxially stretched and poled PVDF film exhibited a high d 31 of 50.2 ± 1.7 pm V -1 at room temperature. Upon heating to 65 °C, the d 31 increased to a maximum value of 76.2 ± 1.2 pm V -1 , and the high piezoelectric performance persisted up to 110 °C. The enhanced piezoelectricity was attributed to the relaxor-like secondary crystals in the oriented amorphous fraction, broken off from the primary crystals by ultrasonication, as suggested by differential scanning calorimetry and broadband dielectric spectroscopy studies.

relaxor-like secondary crystals↗

Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects

The effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd{sub 2}O{sub 2}S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral components in the 40-150 keV range, with a single maximum around 60-80 keV. The radiation output allows for 50 ns resolution, good contrast, and introspective imaging of metallic objects even through metallic walls. A numerical estimation of the induced voltage on the focus during the compressional stage is briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a tomographic hard X-ray spectrometer for suprathermal electron studies with ECRH

Electron cyclotron resonance heating (ECRH) and current drive (ECCD), disruptive instability events and sawtooth activity have been demonstrated to produce suprathermal electrons in fusion devices. The importance of these phenomena for fusion reactors renders suprathermal electron generation and dynamics a key topic in the physics of burning plasmas. Here some significant results from the TCV tokamak are briefly reviewed and a preliminary design of a novel tomographic hard X-ray spectrometer proposed for TCV is discussed. The design is aided by simulations of tomographic reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of hard x rays by femtosecond laser pulse interaction with Cu in laminar helium flow in ambient air

Hard x rays are generated in laminar helium flow in atmosphere (without a vacuum vessel) through the interaction of tightly focused 35 fs laser pulses of varying energy with a Cu target. The energy conversion efficiency from laser to K{alpha} x rays is measured to be 5.4x10{sup -6}, giving a flux of 5.9x10{sup 9} photons/s into 2{pi} sr from a source measuring approximately 9x12 {mu}m{sup 2} in size (verticalxhorizontal). Results are compared to those measured in vacuum and in static helium environments.

07 ISOTOPE AND RADIATION SOURCES↗

Hard x-rays nanoscale fluorescence imaging of Earth and Planetary science samples

A hard x-ray nanoprobe has been implemented at the synchrotron in Grenoble, France, allowing nondestructive trace element imaging of thick samples. Its advantages are nanometer spatial resolution on samples of several tens of micrometer, very high flux, and achromaticity. Nanometer imaging of a cometary grain from the NASA Stardust mission shows the sensitivity and resolution gains obtained while radically changing our understanding of the composition of heterogeneous samples. The probe opens unique possibilities in the study of minute, fragile samples fundamental to the earth and planetary sciences, which until now were out of the reach of direct analytical methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray radiography for density measurement in shock compressed matter

In this letter we report on the direct density measurement in a shock compressed aluminum target using hard x-ray radiography. Experimental data employing a molybdenum K{alpha} source at 17.5 keV, generated with a short pulse laser are presented. High spatial resolution was obtained thanks to a new design for the backlighter geometry. Density values deduced from radiography are compared to predictions from hydrodynamic simulations, which have been calibrated in order to reproduce shock velocities measured from a rear-side self-emission diagnostic. Our results reveal the great potential of this technique as a diagnostic tool for direct density measurements in dense high-Z opaque materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray generation by low energy, tightly focused laser pulses

The interaction of {lambda}{sup 2} laser pulses with plasma is studied to scale the high-field physics from high power laser systems to low-energy, high-repetition-rate lasers. For this purpose, 20 mJ, 40 fs Ti:sapphire laser pulses were focused in a spot of 2.2x2.3 {mu}m{sup 2} with a maximum intensity of I{approx}10{sup 19} W/cm{sup 2}. Efficient generations of energetic electrons ({approx}1 MeV) and hard x-rays with energies of over 100 keV were obtained by irradiating the low-energy, tightly focused laser pulses on a massive Cu target.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution hard x-ray spectroscopy of high-temperature plasmas using an array of quantum microcalorimeters

Quantum microcalorimeters show promise in being able to fully resolve x-ray spectra from heavy highly charged ions, such as would be found in hot plasmas with temperatures in excess of 50 keV. Quantum microcalorimeter arrays are able to achieve this as they have a high-resolving power and good effective quantum efficiency for hard x-ray photons up to 60 keV. To demonstrate this, we present a measurement using an array of thin HgTe quantum microcalorimeters to measure the K-shell spectrum of hydrogenlike through carbonlike praseodymium (Z=57). With this device we are able to attain a resolving power, E/{delta}E, of 1000 at a photon energy of 37 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suprathermal electron studies in the TCV tokamak: Design of a tomographic hard-x-ray spectrometer

Electron cyclotron resonance heating and electron cyclotron current drive, disruptive events, and sawtooth activity are all known to produce suprathermal electrons in fusion devices, motivating increasingly detailed studies of the generation and dynamics of this suprathermal population. Measurements have been performed in the past years in the tokamak a configuration variable (TCV) tokamak using a single pinhole hard-x-ray (HXR) camera and electron-cyclotron-emission radiometers, leading, in particular, to the identification of the crucial role of spatial transport in the physics of ECCD. The observation of a poloidal asymmetry in the emitted suprathermal bremsstrahlung radiation motivates the design of a proposed new tomographic HXR spectrometer reported in this paper. The design, which is based on a compact modified Soller collimator concept, is being aided by simulations of tomographic reconstruction. Quantitative criteria have been developed to optimize the design for the greatly variable shapes and positions of TCV plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Directional properties of hard x-ray sources generated by tightly focused ultrafast laser pulses

Directional properties of ultrafast laser-based hard x-ray sources are experimentally studied using tightly focused approximately millijoule laser pulses incident on a bulk Mo target. Energy distributions of K{alpha} and total x rays, as well as source-size distributions are directionally resolved in vacuum and in flowing helium, respectively. Directional distributions of x-ray emission is more isotropic for p-polarized pump than for s-polarized. Based on source-size measurements, a simple two-location model, with expanded plasma and bulk material, is employed to represent the x-ray source profile.

07 ISOTOPE AND RADIATION SOURCES↗

Thickness dependent electronic structure of La{sub 0.6}Sr{sub 0.4}MnO{sub 3} layer in SrTiO{sub 3}/La{sub 0.6}Sr{sub 0.4}MnO{sub 3}/SrTiO{sub 3} heterostructures studied by hard x-ray photoemission spectroscopy

The authors have investigated changes in the electronic structures of digitally controlled La{sub 0.6}Sr{sub 0.4}MnO{sub 3} (LSMO) layers sandwiched between SrTiO{sub 3} as a function of LSMO layer thickness in terms of hard x-ray photoemission spectroscopy (HX-PES). The HX-PES spectra show the evolution of Mn 3d derived states near the Fermi level and the occurrence of metal-insulator transition at 8 ML. The detailed analysis for the thickness dependent HX-PES spectra reveals the existence of the less conducting and nonmagnetic transition layer with a film thickness of about 4 ML in the interface region owing to significant interaction through the interface.

36 MATERIALS SCIENCE↗

All dielectric hard x-ray mirror by atomic layer deposition

Mirrors consisting of Al{sub 2}O{sub 3} and Ta{sub 2}O{sub 5} ({approx}2 nm film thickness) nanolaminates for hard x-ray wavelengths were produced by atomic layer deposition and characterized. Atomic force microscopy and transmission electron microscopy (TEM) proved extremely smooth surfaces of the mirrors, which are critical for highest reflectance. TEM images showed sharp interfaces between the oxides. The experimental x-ray reflectivity data were theoretically modeled and indicated minimal random thickness variations in the individual layers. Additionally, a depth graded sample with a total thickness of {approx}4 {mu}m for focusing applications in transmission (Laue) geometry and capillaries was coated.

36 MATERIALS SCIENCE↗

{sup 44}Ti Nucleosynthesis Lines and Hard X-ray Continuum in Young SNRs: from INTEGRAL to Simbol-X

Supemovae and their remnants are the main Galactic nucleosynthesis sites and the privileged sources of Galactic cosmic rays. The youngest of such remnants can be studied through two distinct observational features: {sup 44}Ti{gamma}-ray lines and the hard X-ray nonthermal continuum emission. The former gives unique information on the nucleosynthesis conditions occuring during the first stages of the explosion, while the latter provides clues on acceleration processes at supernova remnant shocks. In this contribution, we present new INTEGRAL results on Tycho, the remnant of a historical supernova, and on G1.9+0.3, which has been recently unveiled as the youngest Galactic supernova remnant. Expectations with Simbol-X are also addressed.

79 ASTRONOMY AND ASTROPHYSICS↗

Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study

Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission, ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV, iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW < or approx. 30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray phase contrast imaging of black lipid membranes

We report hard x-ray phase contrast imaging of black lipid membranes, freely suspended over a micromachined aperture in an aqueous solution. Biomolecular and organic substances can thus be probed in hydrated environments by parallel beam propagation imaging, using coherent multi-kilo-electronvolt x-ray radiation. The width of the thinning film can be resolved from analysis of the intensity fringes in the Fresnel diffraction regime down to about 200 nm. The thinning process, in which solvent is expelled from the space in between two opposing monolayers, is monitored, and the domain walls between coexisting domains of swollen and thinned membrane patches are characterized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HARD X-RAYS AS A DIAGNOSTIC TOOL FOR WARM DENSE MATTER

We present the application of short-pulse laser-driven hard x-rays (>40 keV) for the direct density measurement of iron compressed by a laser-driven shock. By using an on-shot calibration of the line density, we are able to obtain line densities even though the x-ray source is not monochromatic. The consequences for the line density measurement using a polychromatic source are discussed in detail, as well as the calibration method we propose to solve this problem.

07 ISOTOPE AND RADIATION SOURCES↗

The Microstructure and Hardness of Hot Dip Galvanized Steel During Wire Drawing

The steel wire samples are hot-dip-galvanized. The zinc coating is preformed using the standard method. To recognize the behavior of the zinc coated steel wire during the submission to deformation, the wire samples are drawn on a machine designed for this aim and then investigated. In this research is represented the phase structure of the zinc coated samples. Afterwards the thickness of the layer and the hardness of the hot-dip galvanized steel depending on the drawing is represented.