Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

DEEPEN 3D PFA Weights for Exploration Datasets in Magmatic Environments

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. As part of the development of the DEEPEN 3D play fairway analysis (PFA) methodology for magmatic plays (conventional hydrothermal, superhot EGS, and supercritical), weights needed to be developed for use in the weighted sum of the different favorability index models produced from geoscientific exploration datasets. This GDR submission includes those weights. The weighting was done using two different approaches: one based on expert opinions, and one based on statistical learning. The weights are intended to describe how useful a particular exploration method is for imaging each component of each play type. They may be adjusted based on the characteristics of the resource under investigation, knowledge of the quality of the dataset, or simply to reduce the impact a single dataset has on the resulting outputs. Within the DEEPEN PFA, separate sets of weights are produced for each component of each play type, since exploration methods hold different levels of importance for detecting each play component, within each play type. The weights for conventional hydrothermal systems were based on the average of the normalized weights used in the DOE-funded PFA projects that were focused on magmatic plays. This decision was made because conventional hydrothermal plays are already well-studied and understood, and therefore it is logical to use existing weights where possible. In contrast, a true PFA has never been applied to superhot EGS or supercritical plays, meaning that exploration methods have never been weighted in terms of their utility in imaging the components of these plays. To produce weights for superhot EGS and supercritical plays, two different approaches were used: one based on expert opinion and the analytical hierarchy process (AHP), and another using a statistical approach based on principal component analysis (PCA). The weights are intended to provide standardized sets of weights for each play type in all magmatic geothermal systems. Two different approaches were used to investigate whether a more data-centric approach might allow new insights into the datasets, and also to analyze how different weighting approaches impact the outcomes. The expert/AHP approach involved using an online tool (https://bpmsg.com/ahp/) with built-in forms to make pairwise comparisons which are used to rank exploration methods against one-another. The inputs are then combined in a quantitative way, ultimately producing a set of consensus-based weights. To minimize the burden on each individual participant, the forms were completed in group discussions. While the group setting means that there is potential for some opinions to outweigh others, it also provides a venue for conversation to take place, in theory leading the group to a more robust consensus then what can be achieved on an individual basis. This exercise was done with two separate groups: one consisting of U.S.-based experts, and one consisting of Iceland-based experts in magmatic geothermal systems. The two sets of weights were then averaged to produce what we will from here on refer to as the "expert opinion-based weights," or "expert weights" for short. While expert opinions allow us to include more nuanced information in the weights, expert opinions are subject to human bias. Data-centric or statistical approaches help to overcome these potential human biases by focusing on and drawing conclusions from the data alone. More information on this approach along with the dataset used to produce the statistical weights may be found in the linked dataset below.

15 GEOTHERMAL ENERGY↗

Coupling subsurface and above-surface models for optimizing the design of borefields and district heating and cooling systems in the presence of varying water-table depth. In: Proceedings, 46th Workshop on Geothermal Reservoir Engineering

Dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes, without flow of groundwater. On the other hand, detailed simulation tools for subsurface heat and mass transfer exist, but these fall short in simulating above-surface energy systems. To support the design and operation of such systems, we have developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the ground. For the first, we use the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, we use the TOUGH simulator. TOUGH can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. In previous work, we described the coupling of these software packages, including how time-dependent boundary conditions for the borehole walls are synchronized for use in Modelica and TOUGH. We verified that the coupled Modelica/TOUGH code produced consistent results with the original Modelica code for an idealized problem in which heat transfer was purely by conduction in a uniform geologic medium. Here, we examine less idealized problems for which TOUGH’s advanced capabilities for modeling fluid flow are required. The first problem has a shallow vadose zone, and the second problem has a thicker vadose zone with a water-table depth that varies in time, which requires a fine vertical grid discretization for the TOUGH model.

Doughtry, Christine↗

Techno-economic feasibility of geothermal energy production using inactive oil and gas wells for district heating and cooling systems in Tuttle, Oklahoma

Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.

15 GEOTHERMAL ENERGY↗

Low-Temperature Geothermal Geospatial Datasets: An Example from Alaska

This project is a component of a broader effort focused on geothermal heating and cooling (GHC) with the aim of illustrating the numerous benefits of incorporating GHC and geothermal heat exchange (GHX) into community energy planning and national decarbonization strategies. To better assist private sector investment, it is currently necessary to define and assess the potential of low-temperature geothermal resources. For shallow GHC/GHX fields, there is no formal compilation of subsurface characteristics shared among industry practitioners that can improve system design and operations. Alaska is specifically noted in this work, because heretofore, it has not received a similar focus in geothermal potential evaluations as the contiguous United States. The methodology consists of leveraging relevant data to generate a baseline geospatial dataset of low-temperature resources (less than 150 degrees C) to compare and analyze information accessible to anyone trying to understand the potential of GHC/GHX and small-scale low-temperature geothermal power in Alaska (e.g., energy modelers, communities, planners, and policymakers). Importantly, this project identifies data related to (1) the evaluation of GHC/GHX in the shallow subsurface, and (2) the evaluation of low-temperature geothermal resource availability. Additionally, data is being compiled to assess repurposing of oil and gas wells to contribute co-produced fluids toward the geothermal direct use and heating and cooling resource potential. In this work we identified new data from three different datasets of isolated geothermal systems in Alaska and bottom-hole temperature data from oil and gas wells that can be leveraged for evaluation of low-temperature geothermal resource potential. The goal of this project is to facilitate future deployment of GHC/GHX analysis and community-led programs and update the low-temperature geothermal resources assessment of Alaska. A better understanding of shallow potential for GHX will improve design and operations of highly efficient GHC systems. The deployment and impact that can be achieved for low-temperature geothermal resources will contribute to decarbonization goals and facilitate widespread electrification by shaving and shifting grid loads.

15 GEOTHERMAL ENERGY↗

GPRA Representation of the Geothermal Technologies Program

The primary goal of the Geothermal Program is to reduce the cost of geothermal generation technologies, including both conventional and engineered geothermal source (EGS) systems. Measuring the GPRA benefits involves projecting the market share for these technologies based on their economic and environmental characteristics.

15 GEOTHERMAL ENERGY↗

Geothermal-Enabled Zero Energy Electric Community: An Integrated System Design Study

In northern climates, developing a zero-energy community is increasingly costly. Building loads are higher, thanks to the colder weather, and solar PV is both less effective, due to lower solar incidence, and misalignment with the buildings' energy needs (summer production, winter demands). We present a novel application for geothermal energy production in support of a zero-energy community, combining appropriate energy efficiency (demand design), geothermal production (supply design), and asset dispatch as an integrated technoeconomic package. This poster presents the process used to explore this system integration challenge, initial results, and discusses some of the technical opportunities for increasing the community-scale adoption of geothermal as an electric and thermal resource. Results indicate that under certain conditions, community-scale geothermal resources are quite competitive with today's grid tariffs and with PV, showing an LCOE within $0.01/kWh before consideration of important grid modernization factors such as resiliency and reliability.

15 GEOTHERMAL ENERGY↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Energy 101: Geothermal Heat Pumps

An energy-efficient heating and cooling alternative, the geothermal heat pump system moves heat from the ground to a building (or from a building to the ground) through a series of flexible pipe "loops" containing water. This edition of Energy 101 explores the benefits Geothermal and the science behind how it all comes together.

15 GEOTHERMAL ENERGY↗

Geothermal-Enabled Zero Energy Electric Community -- An Integrated System Design Study: Preprint

In northern climates, developing a zero-energy community is increasingly costly. Building loads are higher, thanks to the colder weather, and solar PV is both less effective, due to lower solar incidence, and misalignment with the buildings' energy needs (summer production, winter demands). We present a novel application for geothermal energy production in support of a zero-energy community, combining appropriate energy efficiency (demand design), geothermal production (supply design), and asset dispatch as an integrated technoeconomic package. This paper presents the process used to explore this system integration challenge, initial results, and discusses some of the technical opportunities for increasing the community-scale adoption of geothermal as an electric and thermal resource. Results indicate that under certain conditions, community-scale geothermal resources are quite competitive with today's grid tariffs and with PV, showing an LCOE within $0.01/kWh before consideration of important grid modernization factors such as resiliency and reliability.

15 GEOTHERMAL ENERGY↗

Update on Geothermal Direct-Use Installations in the United States

Direct-use of geothermal energy currently has limited penetration in the United States, with an estimated installed capacity of about 500 MWth, supplying on the order of 0.01% of the total annual U.S. heat demand (about 30 EJ). We see higher penetration levels in other countries such as Iceland (about 90%) and Hungary (2.5%). An updated database of geothermal direct-use systems in the U.S. has been compiled and analyzed, building upon the Oregon Institute of Technology (OIT) Geo-Heat Center direct-use database. Types of directuse applications examined include hot springs resorts and pools, aquaculture farms, greenhouses, and district heating systems, among others; power-generating facilities and ground-source heat pumps were excluded. Where possible, the current operation status, open and close dates, well data, and other technical data were obtained for each entry. The database contains 545 installations, of which 407 are open, 108 are closed, and 30 have an unknown status. Spas are the most common type of installation, accounting for 50% of installations by number. Aquaculture installations (46 out of 407 open installations) account for the largest percentage (26%) of installed capacity in operation (129 MWth out of 501 MWth). Historical deployment curves show the installed capacity significantly increased in the 1970s and 1980s mainly due to development of geothermal district heating, aquaculture, and greenhouse systems. Since the 2000s, geothermal direct-use development appears to have slowed, and the number of sites in operation decreased due to closures. Case studies reveal multiple barriers to geothermal direct-use implementation and operation, including 1) existence of an information gap among stakeholders, developers, and the general public, 2) competition from cheap natural gas, and 3) the family-owned, small-scale nature of businesses might result in discontinuation among generations.

15 GEOTHERMAL ENERGY↗

Multifluid geo-energy systems: Using geologic CO 2 storage for geothermal energy production and grid-scale energy storage in sedimentary basins

We present an approach that uses the huge fluid and thermal storage capacity of the subsurface, together with geologic carbon dioxide (CO 2 ) storage, to harvest, store, and dispatch energy from subsurface (geothermal) and surface (solar, nuclear, fossil) thermal resources, as well as excess energy on electric grids. Captured CO 2 is injected into saline aquifers to store pressure, generate artesian flow of brine, and provide a supplemental working fluid for efficient heat extraction and power conversion. Concentric rings of injection and production wells create a hydraulic mound to store pressure, CO 2 , and thermal energy. This energy storage can take excess power from the grid and excess/waste thermal energy, and dispatch that energy when it is demanded and thus enable higher penetration of variable renewable energy technologies (e.g., wind, solar). CO 2 stored in the subsurface functions as a cushion gas to provide enormous pressure-storage capacity and displace large quantities of brine, some of which can be treated for a variety of beneficial uses. Geothermal power and energy-storage applications may generate enough revenues to compensate for CO 2 capture costs. While our approach can use nitrogen (N 2 ), in addition to CO 2 , as a supplemental fluid, and store thermal energy, this study focuses using CO 2 for geothermal energy production and grid-scale energy storage. We conduct a techno-economic assessment to determine the levelized cost of electricity of using this approach to generate geothermal power. We present a reservoir pressure-management strategy that diverts a small portion of the produced brine for beneficial consumptive use to reduce the pumping cost of fluid recirculation, while reducing the risk of seismicity, caprock fracture, and CO 2 leakage.

15 GEOTHERMAL ENERGY↗

Well Monitoring System For EGS

This grant is a collection of projects designed to move aircraft high temperature electronics technology into the geothermal industry. Randy Normann is the lead. He licensed the HT83SNL00 chip from Sandia National Labs. This chip enables aircraft developed electronics for work within a geothermal well logging tool. However, additional elements are needed to achieve commercially successful logging tools. These elements are offered by a strong list of industrial partners on this grant as: Electrochemical Systems Inc. for HT Rechargeable Batteries, Frequency Management Systems for 300C digital clock, Sandia National Labs for experts in high temperature solder, Honeywell Solid-State Electronics Center for reprogrammable high temperature memory. During the course of this project MagiQ Technologies for high temperature fiber optics.

15 GEOTHERMAL ENERGY↗

Recovery Act - Geothermal Technologies Program: Ground Source Heat Pumps Final Scientific/Technical Report

A large centralized geothermal heat pump system was installed to provide ice making, space cooling, space heating, process water heating, and domestic hot water heating for an ice arena in Eagan Minnesota. This paper provides information related to the design and construction of the project. Additionally, operating conditions for 12 months after start-up are provided.

15 GEOTHERMAL ENERGY↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

PoroTomo: Horizontal Distributed Acoustic Sensing (DAS) Measurements During an M 2.3 Explosion

Included here are Distributed Acoustic Sensing (DAS) data collected by the horizontal DAS array at Brady's Hot Springs Geothermal Field. The system recorded this data during an M 2.3 explosion at the Nevada Test Site (NTS), which is located approximately 400km southeast of the field. On December 19, 2018, a Silixa iDAS interrogator continuously acquired data on single-mode fibers, starting approximately two hours prior to the detonation and extending until 15 minutes after the event. This dataset comprises separate SEG-Y files that span the entire recording interval. The measurement fiber was part of the PoroTomo experiment and is horizontally emplaced in alluvial fan gravels at a depth of approximately one meter for a distance of more than 2.5 km in a zig-zag pattern. Exact coordinates of this DAS surface array are provided in the attached GDR dataset below. The iDAS interrogator channel spacing is 1.021 m and gauge length is 10 m. Concurrent Distributed Temperature Sensing (DTS) measurements made with a Silixa XT on the multi-mode fibers aided in calibrating the DAS measurements.

15 GEOTHERMAL ENERGY↗

Appalachian Basin Play Fairway Analysis Analyses and Results

*This submission updates a 2015 submission for the utilization analysis (https://gdr.openei.org/submissions/623)* The files document the analysis of utilization potential in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin. This 2016 submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau 'Places' within the study area. The SLCOHis was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. In addition to calculating SLCOH, this task also identified many industrial sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing and maps of the sites have been plotted as a layer onto different iterations of maps combining the three geologic risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity). In addition, a shapefile of the industrial sites is also included with 7 associated files. Supporting files are also supplied.

15 GEOTHERMAL ENERGY↗