Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Water electrolysis system - H2 and O2 generation

An oxygen generation system design based on the static feed water electrolysis concept is described. The system is designed to generate 4.20 kg/d of oxygen to satisfy the metabolic needs of a three-person crew, to compensate for spacecraft leakage, and to provide the oxygen required by the electrochemical depolarized CO2 concentrator. The system has a fixed hardware weight of 75 kg, occupies a volume of 0.11 cu m, and requires only 1.1 kw of electrical power. The static feed electrolysis concept is discussed, and experimental data on the high-performance electrode are presented.

Schubert, F. H.↗

Surface waves generated by shallow underwater explosions

Surface water waves generated by surface and near surface point explosions are calculated. Taking the impulse distribution imparted at the water surface by the explosion as the overriding mechanism for transferring energy of the explosive to surface wave motion, the linearized theory of Kranzer and Keller is used to obtain the wave displacement in the far field. The impulse distribution is obtained by integrating the pressure wave over an appropriate time interval on a horizontal surface just beneath the undisturbed water surface. For surface explosions, a modified form of the similarity method first used by Collins and Holt is used to obtain the flow field. In the case of submerged explosions, the flow field is estimated by making necessary modifications to Sedov's similarity solution to account for the venting that accompanies the interaction of the leading (blast) wave with the ocean surface. Surface waves generated by a charge at six depths of placement (0.15 m, 0.30 m, 0.61 m, 0.91 m, 1.37 m, 3.05 m) are considered in addition to surface explosions. The results seem to support the existence of an upper critical depth phenomenon (of the type already established for chemical explosions) for point (nuclear) explosions.

Falade, A.↗

Background and system description of the Mod 1 wind turbine generator

The Mod-1 wind turbine considered is a large utility-class machine, operating in the high wind regime, which has the potential for generation of utility grade power at costs competitive with other alternative energy sources. A Mod-1 wind turbine generator (WTG) description is presented, taking into account the two variable-pitch steel blades of the rotor, the drive train, power generation/control, the Nacelle structure, and the yaw drive. The major surface elements of the WTG are the ground enclosure, the back-up battery system, the step-up transformer, elements of the data system, cabling, area lighting, and tower foundation. The final system weight (rotor, Nacelle, and tower) is expected to be about 650,000 pounds. The WTG will be capable of delivering 1800 kW to the utility grid in a wind-speed above 25 mph.

Ernst, E. H.↗

Direct control of the grid point distribution in meshes generated by elliptic equations

The generation of computational grids suitable for obtaining accurate numerical solutions to the three-dimensional Navier-Stokes equations is the subject of intensive research. For a wide class of nozzle configurations, a three-dimensional grid can be constructed by a sequence of two-dimensional grids in successive cross-sectional planes. The present paper is concerned with numerical generation of two-dimensional grids. An effective method of interior grid control is presented based on a modified elliptic system containing free parameters. For a simply connected region, the free parameters are computed from the Dirichlet boundary values. The resulting interior grid point distribution is controlled entirely by a priori selection of the grid point distribution along the boundaries of the section.

Middlecoff, J. F.↗

A viscous flow analysis of the tip vortex generation process

A viscous primary-secondary flow analysis designed for numerical solution by forward marching integration is applied to the tip vortex generation problem. Equations governing streamwise momentum, streamwise vorticity, and a gas law are solved in conjunction with equations governing scalar and vector surface potentials for the secondary velocities. The numerical method used combines a consistently split linearized block implicit (LBI) scheme for parabolic equations and a scalar iterative ADI scheme for elliptic equations. Computed results are presented for a wing of rectangular planform immersed in a high Reynolds number stream at 6 degrees incidence. The physical mechanism for generation of the tip vortex, as revealed by the analysis and computations, is discussed. Detailed flow results for the case of 6 degree incidence are included.

Shamroth, S. J.↗

Low-frequency broadband noise generated by a model rotor

Low-frequency broadband noise generated by model rotors is attributed to the interaction of ingested turbulence with the rotor blades. The influence of free-stream turbulence in the low-frequency broadband noise radiation from model rotors has been experimentally investigated. The turbulence was generated in the M.I.T. anechoic wind tunnel facility with the aid of bipolar grids of various sizes. The spectra and the intensity of the low-frequency broadband noise have been studied as a function of parameters which characterize the turbulence and of helicopter performance parameters. The location of the peak intensity was observed to be strongly dependent on the rotor-tip velocity and on the longitudinal integral scale of turbulence. The size scale of turbulence had negligible effect on the intensity of low-frequency broadband noise. The experimental data show good agreement with an ad hoc model based on unsteady aerodynamics.

Aravamudan, K. S.↗

Dynamics and control of Stirling engines in a 15 kWe solar electric generation concept

This paper discusses the application of kinematic and free piston Stirling engines in a 15 kWe dish-electric approach for solar thermal electric generation. Initially, the principle of operation of Stirling engines in solar thermal electric generation is discussed. Then, under certain simplifying assumptions, mathematical models describing the dynamic operation of the kinematic and free piston Stirling engines are developed. It is found that the engine dynamics may be approximated by second order models. Control mechanisms for both types of Stirling engines are discussed. An approach based on the modulation of the working fluid mean pressure is presented. It is concluded that this approach offers a fast and effective means of control. The free piston Stirling engine, being a thermally driven mechanical oscillator, presents unique control requirements. These are discussed in this paper.

Das, R. L.↗

Energy saving in ac generators

Circuit cuts no-load losses, without sacrificing full-load power. Phase-contro circuit includes gate-controlled semiconductor switch that cuts off applied voltage for most of ac cycle if generator idling. Switch "on" time increases when generator is in operation.

Nola, F. J.↗

A linear magnetic motor and generator

In linear magnetic motor and generator suitable for remote and hostile environments, magnetic forces drive reciprocating shaft along its axis. Actuator shaft is located in center of cylindrical body and may be supported by either contacting or noncontacting bearings. When device operates as bidirectional motor, drive coil selectively adds and subtracts magnetic flux to and from flux paths, producing forces that drive actuator along axis. When actuator is driven by external reciprocating engine, device becomes ac generator.

Studer, P. A.↗

CADAT test pattern generator

CADAT test pattern generator (TPG) aids in checkout, fault detection, and fault isolation of complex digital circuits. Time and effort of manually generating digital test patterns can be major limiting factor in effectively utilizing automatic testing. This time and effort are reduced from several months to several days by TPG.

Source record↗

Start up system for hydrogen generator used with an internal combustion engine

A hydrogen generator provides hydrogen rich product gases which are mixed with the fuel being supplied to an internal combustion engine for the purpose of enabling a very lean mixture of that fuel to be used, whereby nitrous oxides emitted by the engine are minimized. The hydrogen generator contains a catalyst which must be heated to a pre-determined temperature before it can react properly. To simplify the process of heating up the catalyst at start-up time, either some of the energy produced by the engine such as engine exhaust gas, or electrical energy produced by the engine, or the engine exhaust gas may be used to heat up air which is then used to heat the catalyst.

Houseman, J.↗

Executive summary: Mod-1 wind turbine generator analysis and design report

Activities leading to the detail design of a wind turbine generator having a nominal rating of 1.8 megawatts are reported. Topics covered include (1) system description; (2) structural dynamics; (3) stability analysis; (4) mechanical subassemblies design; (5) power generation subsystem; and (6) control and instrumentation subsystem.

Source record↗

Generation of uniform chromaticity scale imagery from LANDSAT data

An algorithm is presented for generating uniform chromaticity scale (UCS) imagery from multispectral data. A computer program was written to implement the algorithm, and UCS film products were generated. The colors in the film and their temporal change are consistent with those expected for the particular scaling of Krauth components into the (lab) color space. The film product was not subjected to the practical test of competing with previous transformations. Preliminary examination indicates that the product offers the following possibilities: (1) a single film product that will supplant two film products in current use; (2) improved visibility of data differences in regions in data space that are critical to crop identification; and (3) an analytic route to the determination of data-space transformations that will be optimal for particular discrimination problems.

Juday, R. D.↗

Preliminary analysis of performance and loads data from the 2-megawatt mod-1 wind turbine generator

Preliminary test data on output power versus wind speed, rotor blade loads, system dynamic behavior, and start-stop characteristics on the Mod-1 wind turbine generator are presented. These data were analyzed statistically and are compared with design predictions of system performance and loads. To date, the Mod-1 wind turbine generator has produced up to 1.5 MW of power, with a measured power versus wind speed curve which agrees closely with design. Blade loads were measured at wind speeds up to 14 m/s and also during rapid shutdowns. Peak transient loads during the most severe shutdowns are less than the design limit loads. On the inboard blade sections, fatigue loads are approximately equal to the design cyclic loads. On the outboard blade sections, however, measured cyclic loads are significantly larger than design values, but they do not appear to exceed fatigue allowable loads as yet.

Spera, D. A.↗

Experiments on H2-O2MHD power generation

Magnetohydrodynamic power generation experiments utilizing a cesium-seeded H2-O2 working fluid were carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments were conducted in a high-field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, axial duct location within the magnetic field, generator loading, B-field strength, and electrode breakdown voltage were investigated. For the operating conditions of these experiments, it is found that the power output increases with the square of the B-field and can be limited by choking of the channel or interelectrode voltage breakdown which occurs at Hall fields greater than 50 volts/insulator. Peak power densities of greater than 100 MW/cu M were achieved.

Smith, J. M.↗

Experimental investigation of dynamic characteristics of turbine generators and low-tuned foundations

Turbine generator (T-G) units with low tuned concrete foundations were investigated experimentally during both startup and normal operating conditions. The dynamic response of the turbine generators and their foundation systems were characterized by resonance curves obtained during the startup transient and by vibration mode shapes at the normal operating condition. No severe resonance at the fundamental frequencies of the system was observed. The deflection or displacement of the foundation pedestal does not lead to unacceptable T-G vibration. The experimental results are compared and discussed with some previous theoretical studies.

Ying, S. P.↗

Application of a numerically generated orthogonal coordinate system to the solution of inviscid axisymmetric supersonic flow over blunt bodies

A numerically generated orthogonal coordinate system (with the body surface and shock wave as opposite boundaries) was applied with a time asymptotic method to obtain steady flow solutions for axisymmetric inviscid flow over several blunt bodies including spheres, paraboloids, ellipsoids, hyperboloids, hemisphere cylinders, spherically blunted cones, and a body with a concavity in the stagnation region. Comparisons with experimental data and with the results of other computational methods are discussed. The numerically generated orthogonal coordinate system is described and applications of the method to complex body shapes, particularly those with concave regions, are discussed.

Hamilton, H. H., II↗