Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLAT PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Corrugated Membrane Fuel Cell Structures

One of the most challenging aspects of traditional PEM fuel cell stacks is the difficulty achieving the platinum catalyst utilization target of 0.2 gPt/kWe set forth by the DOE. Good catalyst utilization can be achieved with state-of-the-art catalyst coated membranes (CCM) when low catalyst loadings (<0.3 mg/cm 2 ) are used at a low current. However, when low platinum loadings are used, the peak power density is lower than conventional loadings, requiring a larger total active area and a larger bipolar plate. This results in a lower overall stack power density not meeting the DOE target. By corrugating the fuel cell membrane electrode structure, Ion Power’s goal is to realize both the Pt utilization targets as well as the power density targets of the DOE. This will be achieved by demonstrating a fuel cell single cell (50 cm 2 ) with a twofold increase in the membrane active area over the geometric area of the cell by corrugating the MEA structure. The corrugating structure must be able to demonstrate the target properties of < 10 mOhm-cm 2 electrical resistance at > 20 psi compressive strength over the active area, in combination with offering at least 80% of power density that can be achieved by using the same MEA in a flat plate structure. Corrugated membrane fuel cell structures also have the potential to meet DOE power density targets by essentially packaging more membrane area into the same fuel cell volume as compared to conventional stack constructions.

08 HYDROGEN↗

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

Hybrid large-eddy simulation with adaptive downstream anisotropic eddy viscosity model

Turbulence pervades most flows of engineering interest, and its prediction remains a challenge on both accuracy and cost. One promising predictive approach that reduces cost combines large-eddy simulation (LES) with simulation based on Reynolds averaged Navier–Stokes equations (RANS). This study presents a method to overcome stability and accuracy issues associated with these hybrid LES-RANS methods. The method developed involves extracting the Reynolds stresses from the upstream LES solution and then using that information to convert the downstream RANS model from a scalar eddy-viscosity model to an anisotropic nonlinear eddy-viscosity model. The method developed differs from the downstream tensorial eddy-viscosity model by being independent of the coordinate system. The method developed was evaluated by computing film cooling of a flat plate with the coolant injected through one row of circular holes. Results obtained show instabilities at the LES-to-RANS interface to be eliminated. Also, the method developed yielded solutions that compare reasonably well with those from LES, even though a significant portion of the flow is computed by the adapted anisotropic RANS model instead of LES, which significantly reduced the number of grid points and computational time needed. Since modification of the downstream RANS model is based on information extracted from the upstream LES solution, the method developed is adaptive to the problem being studied.

42 ENGINEERING↗

Wafer integrated micro‐scale concentrating photovoltaics

Abstract A novel micro‐scale photovoltaic concept, Wafer Integrated Micro‐scale Photovoltaics (WPV), is proposed, analyzed, and experimentally demonstrated. The WPV concept seamlessly integrates multijunction micro‐cells with a multi‐functional silicon platform that simultaneously provides optical concentration, hybrid PV/CPV architecture, and mechanical alignment features. Fabrication and optical performance characterization of the Si platform are described in this paper. Over 100% improvement in the concentration‐acceptance‐angle product ( CAP ) is demonstrated using the wafer‐embedded micro‐concentrating elements, leading to significantly reduced module material and fabrication costs, sufficient angular tolerance for low‐cost trackers, and an ultra‐compact optical architecture compatible with commercial flat panel infrastructures. The development of a prototypical module with a 400× concentration ratio is described. Outdoor optical characterization of the module shows acceptance angles of ±1.7° and ±2.5° for 90% of on‐axis power and full‐width‐half‐maximum, respectively. The projected performance of the PV/CPV hybrid architecture illustrates its potential for cost‐effective collection of both direct and diffuse sunlight, thereby extending the geographic and market domains for cost‐effective PV system deployment. Leveraging low‐cost micro‐fabrication and high‐level integration techniques, the WPV approach presents a promising route to combine the high performance of multijunction solar cells and the low costs of flat‐plate Si PV systems.

Li, Duanhui↗

History of Accelerated and Qualification Testing of Terrestrial Photovoltaic Modules: A Literature Review

We review published literature from 1975 to the present for accelerated stress testing of flat-plate terrestrial photovoltaic (PV) modules. An important facet of this subject is the standard module test sequences that have been adopted by national and international standards organizations, especially those of the International Electrotechnical Commission (IEC). The intent and history of these qualification tests, provided in this review, shows that standard module qualification test results cannot be used to obtain or infer a product lifetime. Closely related subjects also discussed include: other limitations of qualification testing, definitions of module lifetime, module product certification, and accelerated life testing.

14 SOLAR ENERGY↗

Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward extreme high-temperature supercritical CO 2 power cycles: Leakage characterization of ceramic 3D-printed heat exchangers

We report future supercritical carbon dioxide (sCO 2 ) Brayton power cycles demand high-performance gas-to-gas heat exchangers (HXs) operating under extreme temperature and pressure conditions at which most existing superalloy materials fail to function safely. Ceramic HXs are deemed excellent candidates for advanced sCO 2 power plants as they can withstand high-temperature working environments. Particularly, ceramic 3D printing enables compact HX topologies employing complex and efficient heat transfer features. However, ceramic 3D-printed walls separating hot and cold flow streams are susceptible to a through-plane leakage inherent to a powder-based manufacturing process, including ceramic 3D printing. A potential leakage through ceramic separating walls poses a significant challenge in developing reliable ceramic 3D-printed HXs and could deteriorate thermal performance. In this study, various parameters, including feedstock slurry, 3D-printing direction, and post-processing conditions, are considered, for the first time, to characterize the argon gas leakage rate associated with alumina 3D-printed parts. Three 3D-printed ceramic structures of flat plates, curved tubes, and small-scale plate-and-frame HXs with various thicknesses are systematically studied to determine powder and ceramic 3D-printing conditions to eliminate the through-plane leakage. The results showed that an alumina 3D-printed plate with a thickness of 0.75 mm demonstrates a permeability of 6 x 10 -4 milli-darcy. An alumina 3D-printed tube with a wall thickness of 0.9 mm revealed a permeability of 9.6 x 10 -7 milli-darcy. Furthermore, leakage test results of functional 3D-printed modules showed a dependency on the 3D-printing direction. Particularly, alumina cell-scale HXs employing 1.5-mm-thick horizontal and vertical 3D-printed separating walls demonstrated impermeability and gas permeability of 7.2 x 10 -5 millidarcy, respectively. Insights gained from the present study facilitate the development of complex ceramic 3D-printed HXs and other balance of plant components for next-generation high-temperature high-pressure sCO 2 power cycles.

36 MATERIALS SCIENCE↗

Forecasting Solar-Thermal Systems Performance under Transient Operation Using a Data-Driven Machine Learning Approach Based on the Deep Operator Network Architecture

Modeling and prediction of the dynamic behavior of thermal systems operating under intermittent energy input and variable load requirements represent one of the greatest challenges in the development of efficient and reliable renewable-based power generation technologies. In this work, a data-driven machine learning modeling framework was developed based on a modified version of the Deep Operator Network architecture where the time coordinate in the trunk net is replaced with historical data of the predicting quantity. The modeling framework can be used to accurately predict the performance of renewable-based energy conversion technologies including wind- and solar-based power plants. This novel framework was applied on a solar-thermal system that consists of a solar collection loop using a flat plate collector, a power generation loop comprising an Organic Rankine Cycle, and a thermal energy storage tank connecting both loops. Variable solar irradiance, air temperature, and power load profiles were used by the Deep Operator Network to predict the State-of-Charge and the efficiency of the thermal system for several days. The results were compared with the State-of-Charge and efficiency functions calculated using a physics-based model. For a simple operation scenario, characterized by a clear sky solar irradiance profile and constant load, the standard deviation in the State-of-Charge prediction by Deep Operator Network is below 0.9% during a seven-day prediction time horizon. For the most realistic operation scenario that considers real solar irradiance and a rough load profile, the maximum standard deviation in the predictions for the State-of-Charge and efficiency are below 6.8% and 2.5%, respectively. A comparison between Deep Operator Network and Long Short Term Memory network was also performed. In general, both networks predict very well the State-of-Charge for different data density conditions; however, a higher accuracy, with a standard deviation below 2.0%, is obtained by the Deep Operator Network during three and half days using sparser training data of 20-minute points. The same accuracy for the State-of-Charge prediction with the Long Short Term Memory network is achieved only for 14 h. Average standard deviations for the State-of-Charge prediction of 1.1% with the Deep Operator Network and 1.5% with the Long Short Term Memory network are obtained for a four-day prediction time using a denser training data of 5-minute points.

DeepONet↗

Cyclic steady state performance of adsorption chiller with low regeneration temperature zeolite

Adsorption chillers are capable of utilizing inexpensive or free low grade thermal energy such as waste heat and concentrated solar thermal energy. Recently developed low regeneration temperature working pairs allow adsorption chillers to be driven by even lower temperature sources such as engine coolant and flat plate solar collectors. In this work, synthetic zeolite/water was implemented into a 3kW adsorption chiller test facility driven by hot water at 70 C. The zeolite was coated onto two fin-and-tube heat exchangers, with heat recovery employed between the two. Cyclic steady state parametric studies were experimentally conducted to evaluate the chiller's performance, resulting in a cooling coefficient of performance (COP) ranging from 0.1 to 0.6 at different operating conditions. Its performance was compared with published values for other low regeneration temperature working pairs. The physical limitations of the synthetic zeolite revealed by parametric study results were then discussed. A novel operating control strategy was proposed based on the unique characteristics of synthetic zeolite. In addition, a physics-based COP prediction model was derived to predict the performance of the chiller under equilibrium loading, and was validated by the experiment results. This analytical expression can be used to estimate the cyclic steady state performance for future studies.

adsorption↗

Heat transfer characteristics of laminar methane/air flame impinging normal to a cylindrical surface

An experimental study has been conducted to determine the heat transfer characteristics of methane/air laminar flames impinging normal to a cylindrical surface. Effects of variations in the values of Reynolds number (Re = 600-1300), equivalence ratio ({phi} = 0.8-1.3), dimensionless separation distance (H/d = 1-5), and burner diameter to cylinder diameter ratio (d/D = 0.0538-0.1076) have been investigated. Three important configurations, viz., flame inner reaction zone far away, just touching and intercepted by the impingement surface, were examined in detail. High stagnation point heat fluxes were obtained when tip of the flame inner reaction zone just touched the target surface. Stagnation point heat fluxes were either zero or negative when the inner reaction zone was intercepted by the impingement surface. An off-stagnation peak in heat flux was obtained at moderate separation distances above the flame tip. Both stagnation point and peak heat fluxes increased with Re when the inner reaction zone length was less than the separation distance. Heat fluxes in the wall-jet region were high at high Re. Maximum heat fluxes were obtained for initially fuel-rich mixture conditions due to entrainment of the surrounding air. Smaller burner diameters produced high heat flux at the stagnation region for fixed Reynolds number and opposite trends were seen in the wall-jet region. A secondary rise in stagnation point heat flux was obtained at larger separation distances. This secondary rise in heat flux was quite significant for larger burner diameters and at low flow rates. Correlations were developed for stagnation point heat flux. Results were also compared with flat plate under identical operating conditions. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Turbulent structures and budgets behind permeable ribs

Different rib geometries are traditionally used to improve heat transfer and enhance mixing in different industrial applications, i.e. heat exchangers, cooling passages of gas turbine blades and fuel elements of nuclear reactors, etc. Permeable ribs have been proposed in literature for passive control of the reattaching flow past surface mounted ribs leading to superior performance. The flow past different surface mounted permeable rib geometries, i.e. solid, slit, split-slit and inclined split-slit ribs have been investigated in this study. Both two components and stereo particle image velocimetry (PIV) have been used in streamwise and cross stream planes to study the underlying flow structures. The detailed turbulent statistics, i.e. mean and rms velocity, higher order moments, quadrant decomposition of turbulent shear stress producing motions, skewness and components of the turbulent kinetic energy budgets have been compared for different rib geometries. Coherent structures are identified based on the invariant of velocity gradient tensor invariant and wavelet transform. The skewness results demonstrate the intermittency of quadrant motions. The reattachment length of the inclined split-slit rib is lowest among all rib geometries. The average Reynolds stresses and the production of turbulent kinetic energy are highest for the inclined split-slit rib. The pressure transport calculated as residual of the turbulent kinetic energy budget equation is highest for the inclined split-slit rib. This is attributed to the smaller reattachment length leading to greater adverse pressure gradient for the inclined split-slit rib. The quadrant motions, turbulent fluxes, skewness and kinetic energy budgets at post reattachment region compares well with that of flat plate turbulent boundary layer from hot wire measurements in literature. Overall, this study demonstrates the effectiveness of PIV technique for the detailed turbulent structures characterization of complex flows. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Natural convection in metal foam strips with internal heat generation

Natural convection heat transfer in metal foam strips, with internal heat generation, was investigated experimentally for two porosities. An estimate of the non-equilibrium temperature distribution was done by image processing of the thermal maps on both the surface and the inner region of the metal foam specimen. It was shown that heat transfer at natural convection in the strip of metal foam was increased drastically (up to 18-20 times for metal foam of 20 ppi) relative to the flat plate of the same overall dimensions. The heat transfer from ligaments of metal foam was estimated. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

A mixture theory formulation for hydraulic or pneumatic transport of solid particles

In this paper, we discuss the importance of constitutive modeling of the stress tensors in certain engineering issues, related to the pressure drop and skin friction, encountered in solids transport. To study this problem, we first give a brief account of the formulation of a two-component mixture based on the theory proposed by Massoudi, Rajagopal and co-workers. The mixture consists of a linearly viscous fluid infused with solid particles. The solids particles are modeled as a granular media and it is assumed that the mixture is dense enough so that we can use the theory of interacting continua. The subsequent boundary value problem, flow between two flat plates, is then solved numerically and results for various dimensionless numbers are presented for velocities and volume fraction profiles. The engineering quantities of interests discussed are related to the pressure drop and skin friction at the walls.

97 MATHEMATICS AND COMPUTING↗

A physics-based model for frost buildup under turbulent flow using direct numerical simulations

We present a new model for frost buildup under turbulent (and laminar) flow using direct numerical simulations. The physical model consists of two layers, the air and the frost. The air layer is fully resolved and consists of solving for the velocity, temperature, and vapor mass fraction fields. The frost layer thickness is resolved using conservation of mass and energy. Both phases are dynamically coupled using the immersed boundary method. Three-dimensional simulations are conducted in an open-channel configuration. A number of challenges need to be overcome to make these simulations feasible. First, to enforce far-field conditions of zero gradient and prescribed mean temperature and humidity, a source term is added to the energy and transport equations in the flow solver. Second, the mean frost thickness is subtracted after each time step to ensure a constant mean flow thickness and level of turbulence in the numerical domain. Third, a slow-time acceleration approach, which accelerates the frost buildup by a predetermined factor, is employed to bridge the gap between the fast turbulent and slow frost buildup time scales. Finally, a frost densification scheme is used to overcome the difficulties of vertically varying frost properties. The model is validated by comparing the frost thickness and frost thickness buildup rate over a period of one hour from a cooled flat plate experiment. As a result, both quantities compare favorably with experiments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxide evolution on the SiC layer of TRISO particles during extended air oxidation

Tristructural isotropic (TRISO) fuel particles have been primarily developed for high-temperature gas-cooled nuclear reactors and can be subjected to oxidizing environments for extended periods in an off-normal accident scenario. Surrogate TRISO fuel particles were oxidized in air at 1,000 or 1,100 °C for up to 120 h. Here, the oxide scale morphology and thickness were studied via scanning electron microscopy, focused ion beam, and atomic force microscopy. TRISO particles oxidized at 1,100 °C exhibited a highly crystalline oxide scale, which led to significant cracking and irregularly shaped closed porosity, whereas those oxidized at 1,000 °C possessed a primarily amorphous oxide scale, which contained small, rounded internal pores and no larger defects. The observed phenomena deviated from the expected behavior based on models for oxide growth on flat-plate and fiber SiC. The oxidation kinetics of TRISO fuel particles in high-temperature air were investigated without mechanically deforming the surface and were analyzed with respect to oxide morphology.

36 MATERIALS SCIENCE↗